메뉴 건너뛰기




Volumn 15, Issue 4, 2004, Pages 459-465

Dynamic fatigue resistance of implant-abutment junction in an internally notched morse-taper oral implant: Influence of abutment design

Author keywords

Abutment design; Fatigue failure; Mechanical complications; Morse taper; One piece abutment; Two piece abutment

Indexed keywords

CEMENT; METAL;

EID: 4644304411     PISSN: 09057161     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1600-0501.2004.01023.x     Document Type: Article
Times cited : (62)

References (31)
  • 2
    • 0141832052 scopus 로고    scopus 로고
    • Evaluation of the mechanical characteristics of the implant-abutment complex of a reduced-diameter morse taper implant: A nonlinear finite element stress analysis
    • Akça, K., Çehreli, M.C. & İplikçioǧ lu, H. (2003) Evaluation of the mechanical characteristics of the implant-abutment complex of a reduced-diameter morse taper implant: a nonlinear finite element stress analysis. Clinical Oral Implants Research 14: 444-455.
    • (2003) Clinical Oral Implants Research , vol.14 , pp. 444-455
    • Akça, K.1    Çehreli, M.C.2    Iplikçioǧlu, H.3
  • 4
    • 0030148130 scopus 로고    scopus 로고
    • Clinical effectiveness of implant-supported single-tooth replacement: The Toronto study
    • Avivi-Arber, L. & Zarb, G.A. (1996) Clinical effectiveness of implant-supported single-tooth replacement: the Toronto study. International Journal of Oral & Maxillofacial Implants 11: 311-321.
    • (1996) International Journal of Oral & Maxillofacial Implants , vol.11 , pp. 311-321
    • Avivi-Arber, L.1    Zarb, G.A.2
  • 5
    • 0034266196 scopus 로고    scopus 로고
    • The longitudinal clinical effectiveness of ITI solid-screw implants in partially edentulous patients: A 5-year follow-up report
    • Behneke, A., Behneke, N. & d'Hoedt, B. (2000) The longitudinal clinical effectiveness of ITI solid-screw implants in partially edentulous patients: a 5-year follow-up report. International Journal of Oral & Maxillofacial Implants 15: 633-645.
    • (2000) International Journal of Oral & Maxillofacial Implants , vol.15 , pp. 633-645
    • Behneke, A.1    Behneke, N.2    D'Hoedt, B.3
  • 8
    • 0032602123 scopus 로고    scopus 로고
    • Cemented vs. screw-retained implant prosthesis: Which is better? [Current issues forum]
    • Chee, W. (1999) Cemented vs. screw-retained implant prosthesis: Which is better? [Current issues forum]. International Journal of Oral & Maxillofacial Implants 14: 137-138.
    • (1999) International Journal of Oral & Maxillofacial Implants , vol.14 , pp. 137-138
    • Chee, W.1
  • 9
    • 0032088918 scopus 로고    scopus 로고
    • Biological factors contributing to failures of osseointegrated oral implants (II) Etiopathogenesis
    • Esposito, M., Hirsch, J.-M., Lekholm, U. & Thomsen, P. (1998) Biological factors contributing to failures of osseointegrated oral implants (II) Etiopathogenesis. European Journal of Oral Sciences 106: 721-764.
    • (1998) European Journal of Oral Sciences , vol.106 , pp. 721-764
    • Esposito, M.1    Hirsch, J.-M.2    Lekholm, U.3    Thomsen, P.4
  • 10
    • 0033161184 scopus 로고    scopus 로고
    • Differential diagnosis and treatment strategies for biologic complications and failing oral implants: A review of the literature
    • Esposito, M., Hirsch, J.-M., Lekholm, U. & Thomsen, P. (1999) Differential diagnosis and treatment strategies for biologic complications and failing oral implants: a review of the literature. International Journal of Oral & Maxillofacial Implants 14: 473-490.
    • (1999) International Journal of Oral & Maxillofacial Implants , vol.14 , pp. 473-490
    • Esposito, M.1    Hirsch, J.-M.2    Lekholm, U.3    Thomsen, P.4
  • 13
    • 0034132052 scopus 로고    scopus 로고
    • Microleakage of compomer Class V restorations: Effect of load cycling, thermal cycling, and cavity shape differences
    • Hakimeh, S., Vaidyanathan, J., Houpt, M.L., Vaidyanathan, T.K. & von Hagen, S. (2000) Microleakage of compomer Class V restorations: effect of load cycling, thermal cycling, and cavity shape differences. Journal of Prosthetic Dentistry 83: 194-203.
    • (2000) Journal of Prosthetic Dentistry , vol.83 , pp. 194-203
    • Hakimeh, S.1    Vaidyanathan, J.2    Houpt, M.L.3    Vaidyanathan, T.K.4    Von Hagen, S.5
  • 14
    • 0030635617 scopus 로고    scopus 로고
    • Cement-retained versus screw-retained implant restorations: Achieving optimal occlusion and esthetics in implant dentistry
    • Hebel, K.S. & Gajjar, R.C. (1997) Cement-retained versus screw-retained implant restorations: achieving optimal occlusion and esthetics in implant dentistry. Journal of Prosthetic Dentistry 77: 28-35.
    • (1997) Journal of Prosthetic Dentistry , vol.77 , pp. 28-35
    • Hebel, K.S.1    Gajjar, R.C.2
  • 17
    • 0031088298 scopus 로고    scopus 로고
    • A multicenter retrospective analysis of the ITI implant system used for single-tooth replacements: Preliminary results at 6 or more months of loading
    • Levine, R.A., Clem, D.S.III, Wilson, T.G., Higginbottom, F. & Saunders, S.L. (1997) A multicenter retrospective analysis of the ITI implant system used for single-tooth replacements: preliminary results at 6 or more months of loading. International Journal of Oral & Maxillofacial Implants 12: 237-242.
    • (1997) International Journal of Oral & Maxillofacial Implants , vol.12 , pp. 237-242
    • Levine, R.A.1    Clem III, D.S.2    Wilson, T.G.3    Higginbottom, F.4    Saunders, S.L.5
  • 18
    • 0034218915 scopus 로고    scopus 로고
    • Mechanics of the implant-abutment connection: An 8-degree taper compared to a butt joint connection
    • Merz, B.R., Hunenbart, S. & Belser, U.C. (2000) Mechanics of the implant-abutment connection: an 8-degree taper compared to a butt joint connection. International Journal of Oral & Maxillofacial Implants 15: 519-526.
    • (2000) International Journal of Oral & Maxillofacial Implants , vol.15 , pp. 519-526
    • Merz, B.R.1    Hunenbart, S.2    Belser, U.C.3
  • 20
    • 0031197102 scopus 로고    scopus 로고
    • An in vitro evaluation of the strength of an internal conical interface compared to a butt joint design
    • Norton, M.R. (1997) An in vitro evaluation of the strength of an internal conical interface compared to a butt joint design. Clinical Oral Implants Research 8: 290-298.
    • (1997) Clinical Oral Implants Research , vol.8 , pp. 290-298
    • Norton, M.R.1
  • 21
    • 0034186179 scopus 로고    scopus 로고
    • In vitro evaluation of the strength of the conical implant-to-abutment joint in two commercially available implant systems
    • Norton, M.R. (2000a) In vitro evaluation of the strength of the conical implant-to-abutment joint in two commercially available implant systems. Journal of Prosthetic Dentistry 83: 567-571.
    • (2000) Journal of Prosthetic Dentistry , vol.83 , pp. 567-571
    • Norton, M.R.1
  • 22
    • 0034303189 scopus 로고    scopus 로고
    • An in vitro evaluation of the strength of a 1-piece and 2-piece conical abutment joint in implant design
    • Norton, M.R. (2000b) An in vitro evaluation of the strength of a 1-piece and 2-piece conical abutment joint in implant design. Clinical Oral Implants Research 11: 458-464.
    • (2000) Clinical Oral Implants Research , vol.11 , pp. 458-464
    • Norton, M.R.1
  • 24
    • 0022962643 scopus 로고
    • The wear of posterior composite in an artificial mouth: A clinical correlation
    • Sakaguchi, R.L., Douglas, W.H., DeLong, R. & Pintado, M.R. (1986) The wear of posterior composite in an artificial mouth: a clinical correlation. Dental Materials 2: 235-240.
    • (1986) Dental Materials , vol.2 , pp. 235-240
    • Sakaguchi, R.L.1    Douglas, W.H.2    DeLong, R.3    Pintado, M.R.4
  • 26
    • 0034574104 scopus 로고    scopus 로고
    • Mechanical complications of dental implants
    • Schwarz, M.S. (2000) Mechanical complications of dental implants. Clinical Oral Implants Research 1: 156-158.
    • (2000) Clinical Oral Implants Research , vol.1 , pp. 156-158
    • Schwarz, M.S.1
  • 27
    • 0030238166 scopus 로고    scopus 로고
    • Cement-retained implant-supported fixed partial dentures: A 6-month to 3-year follow-up
    • Singer, A. & Serfaty, V. (1996) Cement-retained implant-supported fixed partial dentures: a 6-month to 3-year follow-up. International Journal of Oral & Maxillofacial Implants 11: 645-649.
    • (1996) International Journal of Oral & Maxillofacial Implants , vol.11 , pp. 645-649
    • Singer, A.1    Serfaty, V.2
  • 28
    • 0036365977 scopus 로고    scopus 로고
    • Removable torques of conical, tapered implant abutments: The effects of anodization and reduction of surface area
    • Squier, R.S., Psoter, W.J. & Taylor, T.D. (2002) Removable torques of conical, tapered implant abutments: the effects of anodization and reduction of surface area. International Journal of Oral & Maxillofacial Implants 17: 24-27.
    • (2002) International Journal of Oral & Maxillofacial Implants , vol.17 , pp. 24-27
    • Squier, R.S.1    Psoter, W.J.2    Taylor, T.D.3
  • 31
    • 0029366883 scopus 로고
    • A comparison of implant/prosthesis loading with four clinical variables
    • Weinberg, L.A. & Kruger, B. (1995) A comparison of implant/prosthesis loading with four clinical variables. International Journal of Prosthodontics 8: 421-433.
    • (1995) International Journal of Prosthodontics , vol.8 , pp. 421-433
    • Weinberg, L.A.1    Kruger, B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.