메뉴 건너뛰기




Volumn 17, Issue 4, 2002, Pages 536-542

Comparison of Uniaxial Resistance Forces of Cements Used with Implant-Supported Crowns

Author keywords

Dental cements; Implant supported prosthesis; Luting cements; Retention

Indexed keywords

GOLD ALLOY; TOOTH CEMENT;

EID: 0036633574     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (72)

References (26)
  • 1
    • 0030635617 scopus 로고    scopus 로고
    • Cement-retained versus screw-retained implant restorations: Achieving optimal occlusion and esthetics in implant dentistry
    • Hebel KS, Gajjar RC. Cement-retained versus screw-retained implant restorations: Achieving optimal occlusion and esthetics in implant dentistry. J Prosthet Dent 1997;77: 28-35.
    • (1997) J Prosthet Dent , vol.77 , pp. 28-35
    • Hebel, K.S.1    Gajjar, R.C.2
  • 2
    • 0032602123 scopus 로고    scopus 로고
    • Cemented versus screw-retained implant prosthesis: Which is better?
    • Chee W. Cemented versus screw-retained implant prosthesis: Which is better? [current issues forum] Int J Oral Maxillofac Implants 1999;14:137-138.
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 137-138
    • Chee, W.1
  • 3
    • 0032086151 scopus 로고    scopus 로고
    • Retrievable cemented implant restorations
    • Chee WW, Torbati A, AlbouyJP. Retrievable cemented implant restorations. J Prosthodont 1998;7:120-125.
    • (1998) J Prosthodont , vol.7 , pp. 120-125
    • Chee, W.W.1    Torbati, A.2    Albouy, J.P.3
  • 4
    • 0034266196 scopus 로고    scopus 로고
    • The longitudinal clinical effectiveness of ITI solid-screw implants in partially edentulous patients: A 5-year follow-up report
    • Behneke A, Behneke N, d'Hoedt B. The longitudinal clinical effectiveness of ITI solid-screw implants in partially edentulous patients: A 5-year follow-up report. Int J Oral Maxillofac Implants 2000;15:633-645.
    • (2000) Int J Oral Maxillofac Implants , vol.15 , pp. 633-645
    • Behneke, A.1    Behneke, N.2    D'Hoedt, B.3
  • 5
    • 0030148130 scopus 로고    scopus 로고
    • Clinical effectiveness of implant-supported single-tooth replacement: The Toronto study
    • Avivi-Arber L, Zarb GA. Clinical effectiveness of implant-supported single-tooth replacement: The Toronto study. Int J Oral Maxillofac Implants 1996;11:311-321.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 311-321
    • Avivi-Arber, L.1    Zarb, G.A.2
  • 7
    • 0030155646 scopus 로고    scopus 로고
    • Factors influencing retention of a CeraOne gold cylinder
    • Kent DK, Koka S, Banks SB, Beatty MW. Factors influencing retention of a CeraOne gold cylinder. Implant Dent 1996;5:96-99.
    • (1996) Implant Dent , vol.5 , pp. 96-99
    • Kent, D.K.1    Koka, S.2    Banks, S.B.3    Beatty, M.W.4
  • 8
    • 0034145156 scopus 로고    scopus 로고
    • Effects of abutment size and luting cement type on the uniaxial retention force of implant-supported crowns
    • Covey DA, Kent DK, St Germain HA, Koka S. Effects of abutment size and luting cement type on the uniaxial retention force of implant-supported crowns. J Prosthet Dent 2000;83:344-348.
    • (2000) J Prosthet Dent , vol.83 , pp. 344-348
    • Covey, D.A.1    Kent, D.K.2    St Germain, H.A.3    Koka, S.4
  • 10
    • 0031226028 scopus 로고    scopus 로고
    • The effect of luting agents on the retention and marginal adaptation of the CeraOne implant system
    • Clayton GH, Driscoll CF, Hondrum SO. The effect of luting agents on the retention and marginal adaptation of the CeraOne implant system. Int J Oral Maxillofac Implants 1997;12:660-665.
    • (1997) Int J Oral Maxillofac Implants , vol.12 , pp. 660-665
    • Clayton, G.H.1    Driscoll, C.F.2    Hondrum, S.O.3
  • 11
    • 0029264771 scopus 로고
    • The effect of cementing agent and technique on the retention of a CeraOne gold cylinder: A pilot study
    • Koka S, Ewoldsen NO, Dana CL, Beatty MW. The effect of cementing agent and technique on the retention of a CeraOne gold cylinder: A pilot study. Implant Dent 1995;4:32-35.
    • (1995) Implant Dent , vol.4 , pp. 32-35
    • Koka, S.1    Ewoldsen, N.O.2    Dana, C.L.3    Beatty, M.W.4
  • 12
    • 0033126339 scopus 로고    scopus 로고
    • Tensile bond strengths of provisional luting agents used with an implant system
    • Ramp MH, Dixon DL, Ramp LC, Breeding LC, Barber LL. Tensile bond strengths of provisional luting agents used with an implant system. J Prosthet Dent 1999;81:510-514.
    • (1999) J Prosthet Dent , vol.81 , pp. 510-514
    • Ramp, M.H.1    Dixon, D.L.2    Ramp, L.C.3    Breeding, L.C.4    Barber, L.L.5
  • 14
    • 0033218194 scopus 로고    scopus 로고
    • Complications associated with excess cement around crowns on osseointegrated implants: A clinical report
    • Pauletto N, Lahiffe BJ, Walton JN. Complications associated with excess cement around crowns on osseointegrated implants: A clinical report. Int J Oral Maxillofac Implants 1999;14:865-868.
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 865-868
    • Pauletto, N.1    Lahiffe, B.J.2    Walton, J.N.3
  • 15
    • 0031179216 scopus 로고    scopus 로고
    • Cement removal from restorations luted to titanium abutments with simulated subgingival margins
    • Agar JR, Cameron SM, Hughbanks JC, Parker MH. Cement removal from restorations luted to titanium abutments with simulated subgingival margins. J Prosthet Dent 1997;78:43-47.
    • (1997) J Prosthet Dent , vol.78 , pp. 43-47
    • Agar, J.R.1    Cameron, S.M.2    Hughbanks, J.C.3    Parker, M.H.4
  • 16
    • 0032602123 scopus 로고    scopus 로고
    • Cemented versus screw-retained implant prosthesis: Which is better?
    • Felton DA. Cemented versus screw-retained implant prosthesis: Which is better? [current issues forum] Int J Oral Maxillofac Implants 1999;14:138-139.
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 138-139
    • Felton, D.A.1
  • 17
    • 0031088298 scopus 로고    scopus 로고
    • Multicenter retrospective analysis of the ITI implant system used for single-tooth replacements: Preliminary results at 6 or more months of loading
    • Levine RA, Clem DS, Wilson TG Jr, Higginbottom F, Solnit G. Multicenter retrospective analysis of the ITI implant system used for single-tooth replacements: Preliminary results at 6 or more months of loading. Int J Oral Maxillofac Implants 1997;12:237-242.
    • (1997) Int J Oral Maxillofac Implants , vol.12 , pp. 237-242
    • Levine, R.A.1    Clem, D.S.2    Wilson Jr., T.G.3    Higginbottom, F.4    Solnit, G.5
  • 19
    • 0031152016 scopus 로고    scopus 로고
    • Long-term evaluation of non-submerged ITI implants. Part I: 8-year life table analysis of a prospective multi-center study with 2359 implants
    • Buser D, Mericske-Stern R, Bernard JP, et al. Long-term evaluation of non-submerged ITI implants. Part I: 8-year life table analysis of a prospective multi-center study with 2359 implants. Clin Oral Implants Res 1997:8:161-172.
    • (1997) Clin Oral Implants Res , vol.8 , pp. 161-172
    • Buser, D.1    Mericske-Stern, R.2    Bernard, J.P.3
  • 21
    • 0034223155 scopus 로고    scopus 로고
    • Cement failure loads of 4 provisional luting agents used for the cementation of implant-supported fixed partial dentures
    • Michalakis K, Pissiotis A, Hirayama H. Cement failure loads of 4 provisional luting agents used for the cementation of implant-supported fixed partial dentures. Int J Oral Maxillofac Implants 2000;15:545-549.
    • (2000) Int J Oral Maxillofac Implants , vol.15 , pp. 545-549
    • Michalakis, K.1    Pissiotis, A.2    Hirayama, H.3
  • 22
    • 0031226028 scopus 로고    scopus 로고
    • The effect of luting agents on the retention and marginal adaptation of the CeraOne implant system
    • Clayton GH, Driscoll CF, Hondrum SO. The effect of luting agents on the retention and marginal adaptation of the CeraOne implant system. Int J Oral Maxillofac Implants 1997;12:660-665.
    • (1997) Int J Oral Maxillofac Implants , vol.12 , pp. 660-665
    • Clayton, G.H.1    Driscoll, C.F.2    Hondrum, S.O.3
  • 23
    • 0027015469 scopus 로고
    • Use of luting agents with an implant system: Part II
    • Dixon D, Breeding L, Lilly K. Use of luting agents with an implant system: Part II. J Prosthet Dent 1992;68:885-890.
    • (1992) J Prosthet Dent , vol.68 , pp. 885-890
    • Dixon, D.1    Breeding, L.2    Lilly, K.3
  • 24
    • 0030238166 scopus 로고    scopus 로고
    • Cement-retained implant-supported fixed partial dentures: A 6-month to 3-year follow-up
    • Singer A, Serfaty V. Cement-retained implant-supported fixed partial dentures: A 6-month to 3-year follow-up. Int J Oral Maxillofac Implants 1996;11:645-649.
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 645-649
    • Singer, A.1    Serfaty, V.2
  • 25
    • 0028390316 scopus 로고
    • Loose gold screws frequently occur in full-arch prostheses supported by osseointegrated implants after 5 years
    • Kallus T, Bessing C. Loose gold screws frequently occur in full-arch prostheses supported by osseointegrated implants after 5 years. Int J Oral Maxillofac Implants 1994;9:169-178.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 169-178
    • Kallus, T.1    Bessing, C.2
  • 26
    • 0033158898 scopus 로고    scopus 로고
    • Multicenter retrospective analysis of the ITI implant system used for single-tooth replacements: Results of loading for 2 or more years
    • Levine RA, Clem DS, Wilson TG, Higginbottom F, Solnit G. Multicenter retrospective analysis of the ITI implant system used for single-tooth replacements: Results of loading for 2 or more years. Int J Oral Maxillofac Implants 1999;14: 516-520.
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 516-520
    • Levine, R.A.1    Clem, D.S.2    Wilson, T.G.3    Higginbottom, F.4    Solnit, G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.