메뉴 건너뛰기




Volumn 35, Issue 7, 2008, Pages 3162-3169

Simulation of ultrasound two-dimensional array transducers using a frequency domain model

Author keywords

2D array transducer; b mode image; Beam pattern; Simulation; Ultrasound

Indexed keywords

IMPULSE RESPONSE; TIME DOMAIN ANALYSIS; TRANSDUCERS; ULTRASONIC IMAGING; ULTRASONICS;

EID: 46149125953     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2940158     Document Type: Article
Times cited : (9)

References (26)
  • 3
    • 33847102257 scopus 로고    scopus 로고
    • High element count (3600) fully sampled, two dimensional transducer array," in Proceedings of IEEE Ultrason. Symposium, Vol.
    • M. Eames, S. Zhou, and J. Hossack, "High element count (3600) fully sampled, two dimensional transducer array," in Proceedings of IEEE Ultrason. Symposium, Vol. 11, pp. 2243-2246, 2005.
    • (2005) , vol.11 , pp. 2243-2246
    • Eames, M.1    Zhou, S.2    Hossack, J.3
  • 4
    • 4143053716 scopus 로고    scopus 로고
    • Fully sampled matrix transducer for real time 3D ultrasonic imaging," in Proceedings of IEEE Ultrason. Symposium, Vol.
    • B. Savord and R. Solomon, "Fully sampled matrix transducer for real time 3D ultrasonic imaging," in Proceedings of IEEE Ultrason. Symposium, Vol. 9, pp. 945-953, 2003.
    • (2003) , vol.9 , pp. 945-953
    • Savord, B.1    Solomon, R.2
  • 5
    • 0036667269 scopus 로고    scopus 로고
    • IEEE Trans. Ultrason. Ferroelectr. Freq. Control 0885-3010 10.1109/TUFFC.2002.1026020.
    • A. Austeng and S. Holm, " Sparse 2-D arrays for 3-D phased array imaging-Design methods.," IEEE Trans. Ultrason. Ferroelectr. Freq. Control 0885-3010 10.1109/TUFFC.2002.1026020 49, 1087-1093 (2002).
    • (2002) Sparse 2-D Arrays for 3-D Phased Array Imaging-Design Methods , vol.49 , pp. 1087-1093
    • Austeng, A.1    Holm, S.2
  • 8
    • 4143098230 scopus 로고    scopus 로고
    • A two-dimensional array probe that has a huge number of active channels," in Proceedings of IEEE Ultrason. Symposium, Vol.
    • S. Tezuka, S. Hashimoto, T. Togasaki, Y. Miyajima, and Y. Seo, "A two-dimensional array probe that has a huge number of active channels," in Proceedings of IEEE Ultrason. Symposium, Vol. 1, pp. 960-963, 2003.
    • (2003) , vol.1 , pp. 960-963
    • Tezuka, S.1    Hashimoto, S.2    Togasaki, T.3    Miyajima, Y.4    Seo, Y.5
  • 12
    • 0029838765 scopus 로고    scopus 로고
    • J. Acoust. Soc. Am. 0001-4966 10.1121/1.417914.
    • J. A. Jensen, " Ultrasound field from triangular apertures.," J. Acoust. Soc. Am. 0001-4966 10.1121/1.417914 100, 2049-2056 (1996).
    • (1996) Ultrasound Field from Triangular Apertures , vol.100 , pp. 2049-2056
    • Jensen, J.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.