메뉴 건너뛰기




Volumn 34, Issue 7, 2008, Pages 1053-1062

Adenosine Induces Dilation of Epicardial Coronary Arteries in Mice - Relationship between Coronary Flow Velocity Reserve and Coronary Flow Reserve In Vivo using Transthoracic Echocardiography

Author keywords

Adenosine; Coronary flow reserve; Mouse; Transthoracic Doppler echocardiography; Ultrasound biomicroscopy

Indexed keywords

BLOOD VESSELS; ECHOCARDIOGRAPHY; FLOW VELOCITY; TISSUE ENGINEERING; VELOCITY MEASUREMENT;

EID: 46149083540     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ultrasmedbio.2007.12.004     Document Type: Article
Times cited : (37)

References (34)
  • 1
    • 0026666825 scopus 로고
    • Microsphere and dilution techniques for the determination of blood flows and volumes in conscious mice
    • Barbee R.W., Perry B.D., Re R.N., and Murgo J.P. Microsphere and dilution techniques for the determination of blood flows and volumes in conscious mice. Am J Physiol Regul Integr Comp Physiol 263 (1992) R728-R733
    • (1992) Am J Physiol Regul Integr Comp Physiol , vol.263
    • Barbee, R.W.1    Perry, B.D.2    Re, R.N.3    Murgo, J.P.4
  • 2
    • 0037134942 scopus 로고    scopus 로고
    • Noninvasive assessment of microvascular function in arterial hypertension by transthoracic Doppler harmonic echocardiography
    • Bartel T., Yang Y., Muller S., Wenzel R.R., Baumgart D., Philipp T., and Erbel R. Noninvasive assessment of microvascular function in arterial hypertension by transthoracic Doppler harmonic echocardiography. J Am Coll Cardiol 39 (2002) 2012-2018
    • (2002) J Am Coll Cardiol , vol.39 , pp. 2012-2018
    • Bartel, T.1    Yang, Y.2    Muller, S.3    Wenzel, R.R.4    Baumgart, D.5    Philipp, T.6    Erbel, R.7
  • 3
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M., and Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1 (1986) 307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 4
    • 0027156348 scopus 로고
    • Beneficial effects of colestipol-niacin therapy on the common carotid artery. Two- and four-year reduction of intima-media thickness measured by ultrasound
    • Blankenhorn D.H., Selzer R.H., Crawford D.W., Barth J.D., Liu C.R., Liu C.H., Mack W.J., and Alaupovic P. Beneficial effects of colestipol-niacin therapy on the common carotid artery. Two- and four-year reduction of intima-media thickness measured by ultrasound. Circulation 88 (1993) 20-28
    • (1993) Circulation , vol.88 , pp. 20-28
    • Blankenhorn, D.H.1    Selzer, R.H.2    Crawford, D.W.3    Barth, J.D.4    Liu, C.R.5    Liu, C.H.6    Mack, W.J.7    Alaupovic, P.8
  • 6
    • 0000123717 scopus 로고
    • Overestimation of velocity and frequency values by multielement linear array Dopplers
    • Daigle R.J., Stavros A.T., and Lee R.M. Overestimation of velocity and frequency values by multielement linear array Dopplers. J Vasc Technol 14 (1990) 206-213
    • (1990) J Vasc Technol , vol.14 , pp. 206-213
    • Daigle, R.J.1    Stavros, A.T.2    Lee, R.M.3
  • 7
    • 0026504959 scopus 로고
    • Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity
    • Doucette J.W., Corl P.D., Payne H.M., Flynn A.E., Goto M., Nassi M., and Segal J. Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity. Circulation 85 (1992) 1899-1911
    • (1992) Circulation , vol.85 , pp. 1899-1911
    • Doucette, J.W.1    Corl, P.D.2    Payne, H.M.3    Flynn, A.E.4    Goto, M.5    Nassi, M.6    Segal, J.7
  • 9
    • 2442715037 scopus 로고    scopus 로고
    • Non-invasive imaging of coronary arteries in living mice using high-resolution echocardiography
    • Gan L.M., Wikström J., Bergstrom G., and Wandt B. Non-invasive imaging of coronary arteries in living mice using high-resolution echocardiography. Scand Cardiovasc J 38 (2004) 121-126
    • (2004) Scand Cardiovasc J , vol.38 , pp. 121-126
    • Gan, L.M.1    Wikström, J.2    Bergstrom, G.3    Wandt, B.4
  • 11
    • 33646442642 scopus 로고    scopus 로고
    • Proximal to middle left coronary artery flow velocity ratio, as assessed using color Doppler echocardiography, predicts coronary artery atherosclerosis in mice
    • Gronros J., Wikstrom J., Hagg U., Wandt B., and Gan L.M. Proximal to middle left coronary artery flow velocity ratio, as assessed using color Doppler echocardiography, predicts coronary artery atherosclerosis in mice. Arterioscler Thromb Vasc Biol 26 (2006) 1126-1131
    • (2006) Arterioscler Thromb Vasc Biol , vol.26 , pp. 1126-1131
    • Gronros, J.1    Wikstrom, J.2    Hagg, U.3    Wandt, B.4    Gan, L.M.5
  • 12
    • 0028830686 scopus 로고
    • Noninvasive measurement of ascending aortic blood velocity in mice
    • Hartley C.J., Michael L.H., and Entman M.L. Noninvasive measurement of ascending aortic blood velocity in mice. Am J Physiol 268 (1995) H499-H505
    • (1995) Am J Physiol , vol.268
    • Hartley, C.J.1    Michael, L.H.2    Entman, M.L.3
  • 13
    • 0036736668 scopus 로고    scopus 로고
    • Assessment of coronary flow reserve by adenosine transthoracic echocardiography: Validation with intracoronary Doppler
    • Hildick-Smith D.J., Maryan R., and Shapiro L.M. Assessment of coronary flow reserve by adenosine transthoracic echocardiography: Validation with intracoronary Doppler. J Am Soc Echocardiogr 15 (2002) 984-990
    • (2002) J Am Soc Echocardiogr , vol.15 , pp. 984-990
    • Hildick-Smith, D.J.1    Maryan, R.2    Shapiro, L.M.3
  • 14
    • 0031723491 scopus 로고    scopus 로고
    • Transthoracic echocardiographic measurement of coronary artery diameter: Validation against quantitative coronary angiography
    • Hildick-Smith D.J., and Shapiro L.M. Transthoracic echocardiographic measurement of coronary artery diameter: Validation against quantitative coronary angiography. J Am Soc Echocardiogr 11 (1998) 893-897
    • (1998) J Am Soc Echocardiogr , vol.11 , pp. 893-897
    • Hildick-Smith, D.J.1    Shapiro, L.M.2
  • 15
    • 8644258192 scopus 로고    scopus 로고
    • Measurement of coronary vasomotor function: Getting to the heart of the matter in cardiovascular research
    • Hirata K., Amudha K., Elina R., Hozumi T., Yoshikawa J., Homma S., and Lang C.C. Measurement of coronary vasomotor function: Getting to the heart of the matter in cardiovascular research. Clin Sci (Lond) 107 (2004) 449-460
    • (2004) Clin Sci (Lond) , vol.107 , pp. 449-460
    • Hirata, K.1    Amudha, K.2    Elina, R.3    Hozumi, T.4    Yoshikawa, J.5    Homma, S.6    Lang, C.C.7
  • 16
    • 0032574674 scopus 로고    scopus 로고
    • Noninvasive assessment of significant left anterior descending coronary artery stenosis by coronary flow velocity reserve with transthoracic color Doppler echocardiography
    • Hozumi T., Yoshida K., Ogata Y., Akasaka T., Asami Y., Takagi T., and Morioka S. Noninvasive assessment of significant left anterior descending coronary artery stenosis by coronary flow velocity reserve with transthoracic color Doppler echocardiography. Circulation 97 (1998) 1557-1562
    • (1998) Circulation , vol.97 , pp. 1557-1562
    • Hozumi, T.1    Yoshida, K.2    Ogata, Y.3    Akasaka, T.4    Asami, Y.5    Takagi, T.6    Morioka, S.7
  • 19
    • 14744293746 scopus 로고    scopus 로고
    • Myocardial blood flow mapping in mice using high-resolution spin labeling magnetic resonance imaging: Influence of ketamine/xylazine and isoflurane anesthesia
    • Kober F., Iltis I., Cozzone P.J., and Bernard M. Myocardial blood flow mapping in mice using high-resolution spin labeling magnetic resonance imaging: Influence of ketamine/xylazine and isoflurane anesthesia. Magn Res Med 53 (2005) 601-606
    • (2005) Magn Res Med , vol.53 , pp. 601-606
    • Kober, F.1    Iltis, I.2    Cozzone, P.J.3    Bernard, M.4
  • 20
    • 0037266957 scopus 로고    scopus 로고
    • Correlation of transthoracic Doppler echocardiography and magnetic resonance imaging in measuring left anterior descending artery flow velocity and time-course of dipyridamole-induced coronary flow increase
    • Koskenvuo J.W., Saraste M., Niemi P., Knuuti J., Sakuma H., Toikka J.O., Komu M., Jarvisalo M.J., and Hartiala J.J. Correlation of transthoracic Doppler echocardiography and magnetic resonance imaging in measuring left anterior descending artery flow velocity and time-course of dipyridamole-induced coronary flow increase. Scand J Clin Lab Invest 63 (2003) 65-72
    • (2003) Scand J Clin Lab Invest , vol.63 , pp. 65-72
    • Koskenvuo, J.W.1    Saraste, M.2    Niemi, P.3    Knuuti, J.4    Sakuma, H.5    Toikka, J.O.6    Komu, M.7    Jarvisalo, M.J.8    Hartiala, J.J.9
  • 21
    • 29244432482 scopus 로고    scopus 로고
    • Recommendations for chamber quantification: A report from the American Society of Echocardiography's Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology
    • Lang R.M., Bierig M., Devereux R.B., Flachskampf F.A., Foster E., Pellikka P.A., Picard M.H., Roman M.J., Seward J., Shanewise J.S., Solomon S.D., Spencer K.T., Sutton M.S., and Stewart W.J. Recommendations for chamber quantification: A report from the American Society of Echocardiography's Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology. J Am Soc Echocardiogr 18 (2005) 1440-1463
    • (2005) J Am Soc Echocardiogr , vol.18 , pp. 1440-1463
    • Lang, R.M.1    Bierig, M.2    Devereux, R.B.3    Flachskampf, F.A.4    Foster, E.5    Pellikka, P.A.6    Picard, M.H.7    Roman, M.J.8    Seward, J.9    Shanewise, J.S.10    Solomon, S.D.11    Spencer, K.T.12    Sutton, M.S.13    Stewart, W.J.14
  • 22
    • 0036710972 scopus 로고    scopus 로고
    • Flow dynamics in the left anterior descending coronary artery in infants with idiopathic dilated cardiomyopathy
    • Oskarsson G., and Pesonen E. Flow dynamics in the left anterior descending coronary artery in infants with idiopathic dilated cardiomyopathy. Am J Cardiol 90 (2002) 557-561
    • (2002) Am J Cardiol , vol.90 , pp. 557-561
    • Oskarsson, G.1    Pesonen, E.2
  • 23
    • 0029362334 scopus 로고
    • Echocardiographic and cardiac Doppler assessment of mice
    • Pollick C., Hale S.L., and Kloner R.A. Echocardiographic and cardiac Doppler assessment of mice. J Am Soc Echocardiogr 8 (1995) 602-610
    • (1995) J Am Soc Echocardiogr , vol.8 , pp. 602-610
    • Pollick, C.1    Hale, S.L.2    Kloner, R.A.3
  • 24
    • 0036481560 scopus 로고    scopus 로고
    • Recommendations for quantification of Doppler echocardiography: A report from the Doppler Quantification Task Force of the Nomenclature and Standards Committee of the American Society of Echocardiography
    • Quinones M.A., Otto C.M., Stoddard M., Waggoner A., and Zoghbi W.A. Recommendations for quantification of Doppler echocardiography: A report from the Doppler Quantification Task Force of the Nomenclature and Standards Committee of the American Society of Echocardiography. J Am Soc Echocardiogr 15 (2002) 167-184
    • (2002) J Am Soc Echocardiogr , vol.15 , pp. 167-184
    • Quinones, M.A.1    Otto, C.M.2    Stoddard, M.3    Waggoner, A.4    Zoghbi, W.A.5
  • 27
    • 33746814814 scopus 로고    scopus 로고
    • Coronary flow reserve and heart failure in experimental coxsackievirus myocarditis. A transthoracic Doppler echocardiography study
    • Saraste A., Kyto V., Saraste M., Vuorinen T., Hartiala J., and Saukko P. Coronary flow reserve and heart failure in experimental coxsackievirus myocarditis. A transthoracic Doppler echocardiography study. Am J Physiol Heart Circ Physiol 291 (2006) H871-H875
    • (2006) Am J Physiol Heart Circ Physiol , vol.291
    • Saraste, A.1    Kyto, V.2    Saraste, M.3    Vuorinen, T.4    Hartiala, J.5    Saukko, P.6
  • 28
    • 0035105104 scopus 로고    scopus 로고
    • Coronary flow reserve: Measurement with transthoracic Doppler echocardiography is reproducible and comparable with positron emission tomography
    • Saraste M., Koskenvuo J.W., Knuuti J., Toikka J.O., Laine H., Niemi P., Sakuma H., and Hartiala J.J. Coronary flow reserve: Measurement with transthoracic Doppler echocardiography is reproducible and comparable with positron emission tomography. Clin Physiol 21 (2001) 114-122
    • (2001) Clin Physiol , vol.21 , pp. 114-122
    • Saraste, M.1    Koskenvuo, J.W.2    Knuuti, J.3    Toikka, J.O.4    Laine, H.5    Niemi, P.6    Sakuma, H.7    Hartiala, J.J.8
  • 29
    • 0030032514 scopus 로고    scopus 로고
    • Flow-mediated vasodilation of human epicardial coronary arteries: Effect of inhibition of nitric oxide synthesis
    • Shiode N., Morishima N., Nakayama K., Yamagata T., Matsuura H., and Kajiyama G. Flow-mediated vasodilation of human epicardial coronary arteries: Effect of inhibition of nitric oxide synthesis. J Am Coll Cardiol 27 (1996) 304-310
    • (1996) J Am Coll Cardiol , vol.27 , pp. 304-310
    • Shiode, N.1    Morishima, N.2    Nakayama, K.3    Yamagata, T.4    Matsuura, H.5    Kajiyama, G.6
  • 30
    • 14744290653 scopus 로고    scopus 로고
    • In vivo assessment of absolute perfusion and intracapillary blood volume in the murine myocardium by spin labeling magnetic resonance imaging
    • Streif J.U., Nahrendorf M., Hiller K.H., Waller C., Wiesmann F., Rommel E., Haase A., and Bauer W.R. In vivo assessment of absolute perfusion and intracapillary blood volume in the murine myocardium by spin labeling magnetic resonance imaging. Magn Reson Med 53 (2005) 584-592
    • (2005) Magn Reson Med , vol.53 , pp. 584-592
    • Streif, J.U.1    Nahrendorf, M.2    Hiller, K.H.3    Waller, C.4    Wiesmann, F.5    Rommel, E.6    Haase, A.7    Bauer, W.R.8
  • 32
    • 3042657046 scopus 로고    scopus 로고
    • Matching coronary blood flow to myocardial oxygen consumption
    • Tune J.D., Gorman M.W., and Feigl E.O. Matching coronary blood flow to myocardial oxygen consumption. J Appl Physiol 97 (2004) 404-415
    • (2004) J Appl Physiol , vol.97 , pp. 404-415
    • Tune, J.D.1    Gorman, M.W.2    Feigl, E.O.3
  • 33
    • 23644450360 scopus 로고    scopus 로고
    • Functional and morphologic imaging of coronary atherosclerosis in living mice using high-resolution color Doppler echocardiography and ultrasound biomicroscopy
    • Wikström J., Gronros J., Bergstrom G., and Gan L.-M. Functional and morphologic imaging of coronary atherosclerosis in living mice using high-resolution color Doppler echocardiography and ultrasound biomicroscopy. J Am Coll Cardiol 46 (2005) 720-727
    • (2005) J Am Coll Cardiol , vol.46 , pp. 720-727
    • Wikström, J.1    Gronros, J.2    Bergstrom, G.3    Gan, L.-M.4
  • 34
    • 4844226046 scopus 로고    scopus 로고
    • Comprehensive transthoracic cardiac imaging in mice using ultrasound biomicroscopy with anatomical confirmation by magnetic resonance imaging
    • Zhou Y.Q., Foster F.S., Nieman B.J., Davidson L., Chen X.J., and Henkelman R.M. Comprehensive transthoracic cardiac imaging in mice using ultrasound biomicroscopy with anatomical confirmation by magnetic resonance imaging. Physiol Genomics 18 (2004) 232-244
    • (2004) Physiol Genomics , vol.18 , pp. 232-244
    • Zhou, Y.Q.1    Foster, F.S.2    Nieman, B.J.3    Davidson, L.4    Chen, X.J.5    Henkelman, R.M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.