메뉴 건너뛰기




Volumn 53, Issue 3, 2005, Pages 584-592

In vivo assessment of absolute perfusion and intracapillary blood volume in the murine myocardium by spin labeling magnetic resonance imaging

Author keywords

Anesthesia; Intracapillary blood volume; Mice; MRI; Myocardial infarction; Myocardium; Perfusion; Spin labeling

Indexed keywords

ANESTHESIOLOGY; ANESTHETICS; CARDIOLOGY; HEART; HEMODYNAMICS; MAGNETIC RESONANCE IMAGING; MAMMALS; PIXELS;

EID: 14744290653     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.20327     Document Type: Article
Times cited : (71)

References (40)
  • 1
    • 0037204994 scopus 로고    scopus 로고
    • A comparison of whole-genome shotgunderived mouse chromosome 16 and the human genome
    • Mural R, Adams E, Myers MD, et al. A comparison of whole-genome shotgunderived mouse chromosome 16 and the human genome. Science 2002;296:1661-1671.
    • (2002) Science , vol.296 , pp. 1661-1671
    • Mural, R.1    Adams, E.2    Myers, M.D.3
  • 3
    • 0027370074 scopus 로고
    • Comparison of normal, hypodynamic and hyperdynamic mouse hearts using isolated work-performing heart preparations
    • Grupp I, Subramaniam A, Hewett T, Robbins J, Grupp G. Comparison of normal, hypodynamic and hyperdynamic mouse hearts using isolated work-performing heart preparations. Am J Physiol 1993;265:H1401-H1410.
    • (1993) Am J Physiol , vol.265
    • Grupp, I.1    Subramaniam, A.2    Hewett, T.3    Robbins, J.4    Grupp, G.5
  • 4
    • 0026666825 scopus 로고
    • Microsphere and dilution techniques for the determination of blood flows and volumes in conscious mice
    • Barbee R, Perry B, Ré R, Murgo J. Microsphere and dilution techniques for the determination of blood flows and volumes in conscious mice. Am J Physiol 1992;263:R728-R7332.
    • (1992) Am J Physiol , vol.263
    • Barbee, R.1    Perry, B.2    Ré, R.3    Murgo, J.4
  • 6
    • 0015142919 scopus 로고
    • Some sources of error in measuring regional blood flow with radioactive microspheres
    • Buckberg G, Luck J, Payne D, Hoffman J, Archie J, Fixler D. Some sources of error in measuring regional blood flow with radioactive microspheres. J Appl Physiol 1971;31:598-604.
    • (1971) J Appl Physiol , vol.31 , pp. 598-604
    • Buckberg, G.1    Luck, J.2    Payne, D.3    Hoffman, J.4    Archie, J.5    Fixler, D.6
  • 7
    • 0027483587 scopus 로고
    • Contrast-enhanced first pass myocardial perfusion imaging: Correlation between myocardial blood flow in dogs at rest and during hyperemia
    • Wilke N, Simm C, Zhang J, Ellermann J, Ya X, Merkle H, Path G, Ludemann H, Bache R, Ugurbil K. Contrast-enhanced first pass myocardial perfusion imaging: correlation between myocardial blood flow in dogs at rest and during hyperemia. Magn Reson Med 1993;29:485-497.
    • (1993) Magn Reson Med , vol.29 , pp. 485-497
    • Wilke, N.1    Simm, C.2    Zhang, J.3    Ellermann, J.4    Ya, X.5    Merkle, H.6    Path, G.7    Ludemann, H.8    Bache, R.9    Ugurbil, K.10
  • 8
    • 0031906266 scopus 로고    scopus 로고
    • Magnetic resonance quantification of the myocardial perfusion reserve with a fermi function model for constrained deconvolution
    • Jerosch-Herold M, Wilke N. Magnetic resonance quantification of the myocardial perfusion reserve with a fermi function model for constrained deconvolution. Med Phys 1998;25:73-84.
    • (1998) Med Phys , vol.25 , pp. 73-84
    • Jerosch-Herold, M.1    Wilke, N.2
  • 9
    • 14744299110 scopus 로고    scopus 로고
    • Quantitative analysis of first-pass magnetic resonance perfusion imaging of a mouse model of hindlimb ischemia
    • 71861
    • Kaji S, Ho H, Yang C, Querterinous T, Cooke J, Hu B. Quantitative analysis of first-pass magnetic resonance perfusion imaging of a mouse model of hindlimb ischemia (abstract). Proc Intl Soc Magn Reson Med; 71861:1999.
    • Proc Intl Soc Magn Reson Med , pp. 1999
    • Kaji, S.1    Ho, H.2    Yang, C.3    Querterinous, T.4    Cooke, J.5    Hu, B.6
  • 11
    • 0030012099 scopus 로고    scopus 로고
    • Quantitative magnetic resonance imaging of perfusion using magnetic labeling of water protons within the detection slice
    • Schwarzbauer C, Morissey S, Haase A. Quantitative magnetic resonance imaging of perfusion using magnetic labeling of water protons within the detection slice. Magn Reson Med 1996;35:540-546.
    • (1996) Magn Reson Med , vol.35 , pp. 540-546
    • Schwarzbauer, C.1    Morissey, S.2    Haase, A.3
  • 12
    • 0030608757 scopus 로고    scopus 로고
    • 1 after slice selective spin inversion in the isolated cardioplegique rat heart: Measurement of a lower bound of intracapillary-extravascular water proton exchange rate
    • 1 after slice selective spin inversion in the isolated cardioplegique rat heart: measurement of a lower bound of intracapillary-extravascular water proton exchange rate. Magn Reson Med 1997;38:917-923.
    • (1997) Magn Reson Med , vol.38 , pp. 917-923
    • Bauer, W.1    Roder, F.2    Hiller, K.3    Han, H.4    Frohlich, S.5    Rommel, E.6    Haase, A.7    Ertl, G.8
  • 15
    • 0035895620 scopus 로고    scopus 로고
    • Fast high-resolution magnetic resonance imaging demonstrates fractality of myocardial perfusion in microscopic dimensions
    • Bauer W, Hiller K, Galuppo P, Neubauer S, Köpke J, Haase A, Waller C, Ertl G. Fast high-resolution magnetic resonance imaging demonstrates fractality of myocardial perfusion in microscopic dimensions. Circ Res 2001;88:340-346.
    • (2001) Circ Res , vol.88 , pp. 340-346
    • Bauer, W.1    Hiller, K.2    Galuppo, P.3    Neubauer, S.4    Köpke, J.5    Haase, A.6    Waller, C.7    Ertl, G.8
  • 16
    • 0034103846 scopus 로고    scopus 로고
    • Myocardial perfusion and intracapillary blood volume in rats at rest and with coronary dilatation: MR imaging in vivo with use of a spin-labeling technique
    • Waller C, Kahler E, Hiller K, Hu K, Nahrendorf M, Voll S, Haase A, Ertl G, Bauer W. Myocardial perfusion and intracapillary blood volume in rats at rest and with coronary dilatation: MR imaging in vivo with use of a spin-labeling technique. Radiology 2000;215:189-197.
    • (2000) Radiology , vol.215 , pp. 189-197
    • Waller, C.1    Kahler, E.2    Hiller, K.3    Hu, K.4    Nahrendorf, M.5    Voll, S.6    Haase, A.7    Ertl, G.8    Bauer, W.9
  • 18
    • 0030032648 scopus 로고    scopus 로고
    • Magnetization exchange in capillaries by microcirculation affects diffusion-controlled spin-relaxation: A model which describes the effect of perfusion on relaxation enhancement by intravascular contrast agents
    • Bauer W, Hiller K, Roder F, Rommel E, Ertl G, Haase A. Magnetization exchange in capillaries by microcirculation affects diffusion-controlled spin-relaxation: a model which describes the effect of perfusion on relaxation enhancement by intravascular contrast agents. Magn Reson Med 1996;35:43-55.
    • (1996) Magn Reson Med , vol.35 , pp. 43-55
    • Bauer, W.1    Hiller, K.2    Roder, F.3    Rommel, E.4    Ertl, G.5    Haase, A.6
  • 19
    • 0025213880 scopus 로고
    • Snapshot FLASH MRI. Applications to T1, T2, and chemical-shift imaging
    • Haase A. Snapshot FLASH MRI. Applications to T1, T2, and chemical-shift imaging. Magn Reson Med 1990;13:77-89.
    • (1990) Magn Reson Med , vol.13 , pp. 77-89
    • Haase, A.1
  • 20
    • 0023217321 scopus 로고
    • Improving MR image quality in the presence of motion by using rephasing gradients
    • Haacke E, Lenz G. Improving MR image quality in the presence of motion by using rephasing gradients. Am J Roentgenol 1987;148:1251-1258.
    • (1987) Am J Roentgenol , vol.148 , pp. 1251-1258
    • Haacke, E.1    Lenz, G.2
  • 21
    • 0032601383 scopus 로고    scopus 로고
    • Extracorporal recording of mouse hemodynamic parameters by ultrasound velocity dilution
    • Krvitski N, Starostin D, Smith T. Extracorporal recording of mouse hemodynamic parameters by ultrasound velocity dilution. ASAIO J 1999;45:32-36.
    • (1999) ASAIO J , vol.45 , pp. 32-36
    • Krvitski, N.1    Starostin, D.2    Smith, T.3
  • 23
    • 0037851009 scopus 로고    scopus 로고
    • A coil combination for magnetic resonance perfusion imaging of mice in vivo at 7 T
    • Streif J, Lanz T, Griswold M, Rommel E, Haase A. A coil combination for magnetic resonance perfusion imaging of mice in vivo at 7 T. Rev Sci Instrum 2003;74:2843-2848.
    • (2003) Rev Sci Instrum , vol.74 , pp. 2843-2848
    • Streif, J.1    Lanz, T.2    Griswold, M.3    Rommel, E.4    Haase, A.5
  • 24
    • 48549111126 scopus 로고
    • Highly selective Pi/2 and Pi pulse generation
    • Silver M, Joseph R, Hoult D. Highly selective Pi/2 and Pi pulse generation. J Magn Reson 1984;59:347-351.
    • (1984) J Magn Reson , vol.59 , pp. 347-351
    • Silver, M.1    Joseph, R.2    Hoult, D.3
  • 26
    • 0023218564 scopus 로고
    • Albumin labeled with Gd-DTPA: An intravascular contrast agent for magnetic resonance blood pool imaging: Preparation and characterization
    • Ogan M, Schmiedl U, Moseley M, Grodd W, Paajanen H, Brasch R. Albumin labeled with Gd-DTPA: an intravascular contrast agent for magnetic resonance blood pool imaging: preparation and characterization. Invest Radiol 1987;22:665-671.
    • (1987) Invest Radiol , vol.22 , pp. 665-671
    • Ogan, M.1    Schmiedl, U.2    Moseley, M.3    Grodd, W.4    Paajanen, H.5    Brasch, R.6
  • 27
    • 0001480742 scopus 로고
    • Quantification of T1 values by snapshot FLASH NMR imaging
    • Deichmann R, Haase A. Quantification of T1 values by snapshot FLASH NMR imaging. J Magn Reson 1992;96:608-612.
    • (1992) J Magn Reson , vol.96 , pp. 608-612
    • Deichmann, R.1    Haase, A.2
  • 28
    • 0002373838 scopus 로고
    • Wasser- und elektrolythaushalt
    • Schmidt RF, Thews G, editors. 24th ed. Berlin: Springer-Verlag
    • Deetjen P. Wasser- und Elektrolythaushalt. In: Schmidt RF, Thews G, editors. Physiologie des Menschen 1990;24th ed. Berlin: Springer-Verlag; p 808-818.
    • (1990) Physiologie des Menschen , pp. 808-818
    • Deetjen, P.1
  • 29
  • 30
    • 0028794590 scopus 로고
    • Coronary vasodilation by isoflurane abrupt versus gradual administration
    • Crystal G, Czinn E, Silver J, Salem M. Coronary vasodilation by isoflurane abrupt versus gradual administration. Anesthesiology 1995;82:542-549.
    • (1995) Anesthesiology , vol.82 , pp. 542-549
    • Crystal, G.1    Czinn, E.2    Silver, J.3    Salem, M.4
  • 32
    • 0023836361 scopus 로고
    • Acquisition order and motional artifact reduction in spin warp images
    • Dixon W, Brummer M, Malko J. Acquisition order and motional artifact reduction in spin warp images. Magn Reson Med 1988;6:74-83.
    • (1988) Magn Reson Med , vol.6 , pp. 74-83
    • Dixon, W.1    Brummer, M.2    Malko, J.3
  • 34
    • 0035690201 scopus 로고    scopus 로고
    • Spatial heterogeneity of perfusion and energy turnover in the heart
    • Decking U, Schrader J. Spatial heterogeneity of perfusion and energy turnover in the heart. Z Kardol 2001;90:970-977.
    • (2001) Z Kardol , vol.90 , pp. 970-977
    • Decking, U.1    Schrader, J.2
  • 36
    • 0042326404 scopus 로고    scopus 로고
    • Cardiac magnetic resonance imaging in small animal models of human heart failure
    • Nahrendorf M, Hiller K, Hu K, Ertl G, Haase A, Bauer W. Cardiac magnetic resonance imaging in small animal models of human heart failure. Med Image Anal 2003;7:369-375.
    • (2003) Med Image Anal , vol.7 , pp. 369-375
    • Nahrendorf, M.1    Hiller, K.2    Hu, K.3    Ertl, G.4    Haase, A.5    Bauer, W.6
  • 37
    • 0026316218 scopus 로고
    • Cellular basis of ventricular remodeling after myocardial infarction
    • Anversa P, Olivetti G, Capasso J. Cellular basis of ventricular remodeling after myocardial infarction. Am J Cardiol 1991;68:7D-16D.
    • (1991) Am J Cardiol , vol.68
    • Anversa, P.1    Olivetti, G.2    Capasso, J.3
  • 38
    • 0026017365 scopus 로고
    • Effects of barium induced cardiac contraction on large and small vessel intramyocardial blood volume
    • Judd R, Levy B. Effects of barium induced cardiac contraction on large and small vessel intramyocardial blood volume. Circ Res 1991;68:217-225.
    • (1991) Circ Res , vol.68 , pp. 217-225
    • Judd, R.1    Levy, B.2
  • 39
    • 0004012007 scopus 로고
    • Small vessel and total coronary blood volume during intracoronary adenosine
    • Crystal G, Downey H, Bashour F. Small vessel and total coronary blood volume during intracoronary adenosine. Am J Physiol 1981;241:H194-H201.
    • (1981) Am J Physiol , vol.241
    • Crystal, G.1    Downey, H.2    Bashour, F.3
  • 40
    • 0036237117 scopus 로고    scopus 로고
    • Determination of regional blood volume and intraextracapillary water exchange in human myocardium using Feruglose: First clinical results in patients with coronary artery disease
    • Wacker C, Wiesmann F, Bock M, Jakob P, Sandstede J, Lehning A, Ertl G, Schad L, Haase A, Bauer W. Determination of regional blood volume and intraextracapillary water exchange in human myocardium using Feruglose: first clinical results in patients with coronary artery disease. Magn Reson Med 2002;47:1013-1016.
    • (2002) Magn Reson Med , vol.47 , pp. 1013-1016
    • Wacker, C.1    Wiesmann, F.2    Bock, M.3    Jakob, P.4    Sandstede, J.5    Lehning, A.6    Ertl, G.7    Schad, L.8    Haase, A.9    Bauer, W.10


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.