-
1
-
-
0021850318
-
High resolution NMR imaging in solids
-
S. Emid, J.H.N. Creyghton, High resolution NMR imaging in solids, Phys. B 128 (1985) 81.
-
(1985)
Phys. B
, vol.128
, pp. 81
-
-
Emid, S.1
Creyghton, J.H.N.2
-
3
-
-
44949291663
-
2 relaxation and its application to Boron-11 NMR imaging of a BNCT agent in an intact rat
-
2 relaxation and its application to Boron-11 NMR imaging of a BNCT agent in an intact rat, J. Magn. Reson. 88 (1990) 369-375.
-
(1990)
J. Magn. Reson.
, vol.88
, pp. 369-375
-
-
Bendel, P.1
Davis, M.2
Berman, E.3
Kabalka, G.W.4
-
4
-
-
0027978407
-
Multipoint k-space point mapping (KPM) technique for NMR microscopy
-
Z.H Cho, Y.M. Ro, Multipoint k-space point mapping (KPM) technique for NMR microscopy, Magn. Reson. Med. 32 (1994) 258-262.
-
(1994)
Magn. Reson. Med.
, vol.32
, pp. 258-262
-
-
Cho, Z.1
Ro, Y.M.2
-
7
-
-
0000215593
-
SPRITE MRI with prepared magnetization and centric k-space sampling
-
I.V. Mastikhin, B.J. Balcom, P.J. Prado, C.B. Kennedy, SPRITE MRI with prepared magnetization and centric k-space sampling, J. Magn. Reson. 136 (1999) 159-168.
-
(1999)
J. Magn. Reson.
, vol.136
, pp. 159-168
-
-
Mastikhin, I.V.1
Balcom, B.J.2
Prado, P.J.3
Kennedy, C.B.4
-
8
-
-
0042995268
-
Chemically selective NMR imaging of a 3-component (solid-solid-liquid) sedimenting system
-
S.D. Beyea, S.A. Altobelli, L.A. Mondy, Chemically selective NMR imaging of a 3-component (solid-solid-liquid) sedimenting system, J. Magn. Reson, 161 (2003) 198-203.
-
(2003)
J. Magn. Reson
, vol.161
, pp. 198-203
-
-
Beyea, S.D.1
Altobelli, S.A.2
Mondy, L.A.3
-
9
-
-
0344464740
-
Centric scan SPRITE magnetic resonance imaging
-
M. Halse, D.J. Goodyear, B. MacMillan, P. Szomolanyi, D. Matheson, B.J. Balcom, Centric scan SPRITE magnetic resonance imaging, J. Magn. Reson. 165 (2003) 219-229.
-
(2003)
J. Magn. Reson.
, vol.165
, pp. 219-229
-
-
Halse, M.1
Goodyear, D.J.2
MacMillan, B.3
Szomolanyi, P.4
Matheson, D.5
Balcom, B.J.6
-
10
-
-
0030915044
-
The use of active noise control (ANC) to reduce acoustic noise generated during MRI scanning: Some initial results
-
M. McJury, R.W. Stewart, D. Crawford, E. Toma, The use of active noise control (ANC) to reduce acoustic noise generated during MRI scanning: some initial results, Magn. Reson. Imaging 15 (1997) 319-322.
-
(1997)
Magn. Reson. Imaging
, vol.15
, pp. 319-322
-
-
McJury, M.1
Stewart, R.W.2
Crawford, D.3
Toma, E.4
-
12
-
-
0033841785
-
Anatomic MR images obtained with silent sequences
-
F. Girard, V.L. Marcar, F. Hennel, E. Martin, Anatomic MR images obtained with silent sequences, Radiology 216 (2000) 900-902.
-
(2000)
Radiology
, vol.216
, pp. 900-902
-
-
Girard, F.1
Marcar, V.L.2
Hennel, F.3
Martin, E.4
-
13
-
-
0035008768
-
Fast spin echo and fast gradient echo MRI with low acoustic noise
-
F. Hennel, Fast spin echo and fast gradient echo MRI with low acoustic noise, J. Magn, Reson. Imaging 13 (2001) 960-966.
-
(2001)
J. Magn, Reson. Imaging
, vol.13
, pp. 960-966
-
-
Hennel, F.1
-
14
-
-
0034129413
-
Principles of active acoustic control in gradient coil design
-
P. Mansfield, B. Haywood, Principles of active acoustic control in gradient coil design, MAGMA 10 (2000) 147-151.
-
(2000)
MAGMA
, vol.10
, pp. 147-151
-
-
Mansfield, P.1
Haywood, B.2
-
15
-
-
0242322619
-
Optimized gradient pulse for use with EPI employing active acoustic control
-
B.L.W. Chapman, B. Haywood, P. Mansfield, Optimized gradient pulse for use with EPI employing active acoustic control, Magn. Reson. Med. 50 (2003) 931-935.
-
(2003)
Magn. Reson. Med.
, vol.50
, pp. 931-935
-
-
Chapman, B.L.W.1
Haywood, B.2
Mansfield, P.3
-
16
-
-
0031032023
-
Characterization and prediction of gradient acoustic noise in MR imagers
-
R.A. Hedeen, W.A. Edelstein, Characterization and prediction of gradient acoustic noise in MR imagers, Magn. Reson. Med. 37 (1997) 7-10.
-
(1997)
Magn. Reson. Med.
, vol.37
, pp. 7-10
-
-
Hedeen, R.A.1
Edelstein, W.A.2
-
17
-
-
0028812364
-
Active acoustic screening: Reduction of noise in gradient coils by Lorentz force balancing
-
P. Mansfield, B.L.W. Chapman, R. Bowtell, P. Glover, R. Coxon, P.R. Harvey, Active acoustic screening: reduction of noise in gradient coils by Lorentz force balancing, Magn. Reson. Med. 33 (1995) 276-281.
-
(1995)
Magn. Reson. Med.
, vol.33
, pp. 276-281
-
-
Mansfield, P.1
Chapman, B.L.W.2
Bowtell, R.3
Glover, P.4
Coxon, R.5
Harvey, P.R.6
-
18
-
-
0029147419
-
Quiet transverse gradient coils: Lorentz force balanced designs using geometrical similitude
-
R.W. Bowtell, P. Mansfield, Quiet transverse gradient coils: Lorentz force balanced designs using geometrical similitude, Magn. Reson. Med. 34 (1995) 494-497.
-
(1995)
Magn. Reson. Med.
, vol.34
, pp. 494-497
-
-
Bowtell, R.W.1
Mansfield, P.2
-
19
-
-
0030930285
-
Analysis of acoustic noise in MRI
-
Z.H. Cho, S.H. Park, J.H. Kim, S.C. Chung, S.T. Chung, J.Y. Chung, C.W. Moon, J.H. Yi, C.H. Sin, E.K. Wong, Analysis of acoustic noise in MRI, Magn. Reson. Imaging 15 (1997) 815-822.
-
(1997)
Magn. Reson. Imaging
, vol.15
, pp. 815-822
-
-
Cho, Z.H.1
Park, S.H.2
Kim, J.H.3
Chung, S.C.4
Chung, S.T.5
Chung, J.Y.6
Moon, C.W.7
Yi, J.H.8
Sin, C.H.9
Wong, E.K.10
-
20
-
-
4544242711
-
The spatial distribution and prediction of gradient induced acoustic noise in a 4T MRI scanner
-
Toronto
-
W. Li, C.K. Mechefske, C. Gazdzinski, B.K. Rutt, The spatial distribution and prediction of gradient induced acoustic noise in a 4T MRI scanner, in: Proceedings of the 11th Annual Meeting of ISMRM, Toronto, 2003, p. 746.
-
(2003)
Proceedings of the 11th Annual Meeting of ISMRM
, pp. 746
-
-
Li, W.1
Mechefske, C.K.2
Gazdzinski, C.3
Rutt, B.K.4
|