메뉴 건너뛰기




Volumn 50, Issue 5, 2003, Pages 931-935

Optimized Gradient Pulse for Use With EPI Employing Active Acoustic Control

Author keywords

50 dB acoustic noise reduction; Acoustic gradient pulse; EPI; Gradient coils

Indexed keywords

NOISE ABATEMENT;

EID: 0242322619     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.10635     Document Type: Article
Times cited : (16)

References (10)
  • 3
    • 0034129413 scopus 로고    scopus 로고
    • Principles of active acoustic control in gradient coil design
    • Mansfield P, Haywood B. Principles of active acoustic control in gradient coil design. MAGMA 2000;10:147-151.
    • (2000) MAGMA , vol.10 , pp. 147-151
    • Mansfield, P.1    Haywood, B.2
  • 4
    • 0034789174 scopus 로고    scopus 로고
    • Active acoustic control in gradient coils in MRI
    • Mansfield P, Haywood B, Coxon R. Active acoustic control in gradient coils in MRI. Magn Reson Med 2001;46:807-818.
    • (2001) Magn Reson Med , vol.46 , pp. 807-818
    • Mansfield, P.1    Haywood, B.2    Coxon, R.3
  • 5
    • 0242304665 scopus 로고    scopus 로고
    • Reduction of acoustic noise in gradient coils in MRI
    • Paper no. 483
    • Haywood B, Mansfield P, Chapman B, Reduction of acoustic noise in gradient coils in MRI. MAGMA 2002;15(Suppl 1):235-236. Paper no. 483.
    • (2002) MAGMA , vol.15 , Issue.SUPPL. 1 , pp. 235-236
    • Haywood, B.1    Mansfield, P.2    Chapman, B.3
  • 6
    • 0003633434 scopus 로고
    • Fourier transforms and their physical applications
    • Champeney DC. Fourier transforms and their physical applications. Techniques Physics Ser 1973;1.
    • (1973) Techniques Physics Ser , pp. 1
    • Champeney, D.C.1
  • 7
    • 0003154349 scopus 로고    scopus 로고
    • Silent MRI system by interrupting the vibrational transmission through the air and solid structures
    • ISMRM April, poster 1372
    • Katsunuma A, Takamori H, Yoshida T. Silent MRI system by interrupting the vibrational transmission through the air and solid structures. Magn Reson Med Abstr, ISMRM April 2000, poster 1372.
    • (2000) Magn Reson Med Abstr
    • Katsunuma, A.1    Takamori, H.2    Yoshida, T.3
  • 8
  • 9
    • 0003212795 scopus 로고
    • Quiet gradient coils: Active acoustically and magnetically screened distributed transverse gradient designs
    • Chapman BLW, Mansfield P. Quiet gradient coils: active acoustically and magnetically screened distributed transverse gradient designs. Meas Sci Technol 1995;6:349-354.
    • (1995) Meas Sci Technol , vol.6 , pp. 349-354
    • Chapman, B.L.W.1    Mansfield, P.2
  • 10
    • 0031032023 scopus 로고    scopus 로고
    • Characterization and prediction of gradient acoustic noise in MR imagers
    • Hedeen RA, Edelstein WA. Characterization and prediction of gradient acoustic noise in MR imagers. Magn Reson Med 1997;37:7-10.
    • (1997) Magn Reson Med , vol.37 , pp. 7-10
    • Hedeen, R.A.1    Edelstein, W.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.