메뉴 건너뛰기




Volumn 42, Issue 1, 1999, Pages 6-10

'Silent' MRI with soft gradient pulses

Author keywords

Acoustic noise; MRI; Noise reduction

Indexed keywords

FREQUENCY RESPONSE; MAGNETIC RESONANCE IMAGING; NOISE ABATEMENT;

EID: 0032768595     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1522-2594(199907)42:1<6::AID-MRM2>3.0.CO;2-D     Document Type: Article
Times cited : (119)

References (22)
  • 3
    • 0028331449 scopus 로고
    • Measurement of acoustic noise during MR imaging: Evaluation of six worse-case pulse sequences
    • Shellock FG, Morisoli SM, Ziarati M. Measurement of acoustic noise during MR imaging: evaluation of six worse-case pulse sequences. Radiology 1994;191:91.
    • (1994) Radiology , vol.191 , pp. 91
    • Shellock, F.G.1    Morisoli, S.M.2    Ziarati, M.3
  • 5
    • 0028999605 scopus 로고
    • Acoustic noise levels generated during high field MRI
    • Mcjury MJ. Acoustic noise levels generated during high field MRI. Clin Radiol 1995;50:331-334.
    • (1995) Clin Radiol , vol.50 , pp. 331-334
    • McJury, M.J.1
  • 6
    • 0031758426 scopus 로고    scopus 로고
    • Determination of gradient magnetic field-induced acoustic noise associated with the use of echo planar and three-dimensional fast spin-echo techniques
    • Shellock FG, Ziarati M, Atkinson D, Chen DY. Determination of gradient magnetic field-induced acoustic noise associated with the use of echo planar and three-dimensional fast spin-echo techniques. J Magn Reson Imaging 1998;8:1154-1157.
    • (1998) J Magn Reson Imaging , vol.8 , pp. 1154-1157
    • Shellock, F.G.1    Ziarati, M.2    Atkinson, D.3    Chen, D.Y.4
  • 8
    • 0023724390 scopus 로고
    • Potential hearing loss resulting from MR imaging
    • Brunnet RE, Talbot JM, Charuhas P. Potential hearing loss resulting from MR imaging. Radiology 1989;169:539-540.
    • (1989) Radiology , vol.169 , pp. 539-540
    • Brunnet, R.E.1    Talbot, J.M.2    Charuhas, P.3
  • 10
    • 0031885960 scopus 로고    scopus 로고
    • Effects of the acoustic noise of the gradient system on FMRI: A study of auditory, motor, and visual cortices
    • Cho ZH, Chung SC, Lim DW, Wong EK. Effects of the acoustic noise of the gradient system on FMRI: a study of auditory, motor, and visual cortices. Magn Reson Med 1998;39:331-335.
    • (1998) Magn Reson Med , vol.39 , pp. 331-335
    • Cho, Z.H.1    Chung, S.C.2    Lim, D.W.3    Wong, E.K.4
  • 12
    • 0024343056 scopus 로고
    • Reduction of sound levels with anti-noise in MR imaging
    • Golman AM, Grossman WE, Friedlander PC. Reduction of sound levels with anti-noise in MR imaging. Radiology 1989;173:549-550.
    • (1989) Radiology , vol.173 , pp. 549-550
    • Golman, A.M.1    Grossman, W.E.2    Friedlander, P.C.3
  • 13
    • 0030915044 scopus 로고    scopus 로고
    • The use of active noise control (ANC) to reduce acoustic noise generated during MRI scanning: Some initial results
    • McJury M, Stewart RW, Crawford D, Toma E. The use of active noise control (ANC) to reduce acoustic noise generated during MRI scanning: some initial results. Magn Reson Imaging 1997;115:319-322.
    • (1997) Magn Reson Imaging , vol.115 , pp. 319-322
    • McJury, M.1    Stewart, R.W.2    Crawford, D.3    Toma, E.4
  • 15
    • 0029147419 scopus 로고
    • Quiet transverse gradient coils: Lorentz force balanced designs using geometrical similitude
    • Bowtell R, Mansfield P. Quiet transverse gradient coils: Lorentz force balanced designs using geometrical similitude. Magn Reson Med 1995;34:494-497.
    • (1995) Magn Reson Med , vol.34 , pp. 494-497
    • Bowtell, R.1    Mansfield, P.2
  • 16
    • 0001134025 scopus 로고    scopus 로고
    • Masking of acoustic stimuli by the gradient noise alters the fMRI detectable activation in a particular human auditory cortex
    • Baumgart F, Gaschler B, Tempelmann C, Tegeler C, Stiller D, Heinze HJ, Scheich H. Masking of acoustic stimuli by the gradient noise alters the fMRI detectable activation in a particular human auditory cortex. MAGMA 1996;4(suppl):185.
    • (1996) MAGMA , vol.4 , Issue.SUPPL. , pp. 185
    • Baumgart, F.1    Gaschler, B.2    Tempelmann, C.3    Tegeler, C.4    Stiller, D.5    Heinze, H.J.6    Scheich, H.7
  • 19
    • 0031032023 scopus 로고    scopus 로고
    • Characterization and prediction of gradient acoustic noise in MR imagers
    • Hedeen RA, Edelstein WA. Characterization and prediction of gradient acoustic noise in MR imagers. Magn Reson Med 1997;37:7-10.
    • (1997) Magn Reson Med , vol.37 , pp. 7-10
    • Hedeen, R.A.1    Edelstein, W.A.2
  • 20
    • 0022872540 scopus 로고
    • RARE imaging: A fast imaging method for clinical MR
    • Hennig J, Nauerth A, Friedburg H. RARE imaging: a fast imaging method for clinical MR. Magn Reson Med 1986;3:823-833.
    • (1986) Magn Reson Med , vol.3 , pp. 823-833
    • Hennig, J.1    Nauerth, A.2    Friedburg, H.3
  • 21
    • 0025213880 scopus 로고
    • Snapshot flash mri. Applications to T1, T2, and chemical-shift imaging
    • Haase A. Snapshot FLASH MRI. Applications to T1, T2, and chemical-shift imaging. Magn Reson Med 1990;13:77-89.
    • (1990) Magn Reson Med , vol.13 , pp. 77-89
    • Haase, A.1
  • 22
    • 36149042452 scopus 로고
    • Multi-planar image formation using NMR spin-echoes
    • Mansfield P. Multi-planar image formation using NMR spin-echoes. J Phys C 1977;10:L55-58.
    • (1977) J Phys C , vol.10
    • Mansfield, P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.