메뉴 건너뛰기




Volumn 59, Issue 9, 2004, Pages 1389-1394

Determination of B, Si, P and S in steels by inductively coupled plasma quadrupole mass spectrometry with dynamic reaction cell

Author keywords

Boron; Dynamic reaction cell; Inductively coupled plasma mass spectrometry; Phosphorus; Silicon; Steel; Sulfur

Indexed keywords

BORON; FLUORESCENCE; INDUCTIVELY COUPLED PLASMA; OXYGEN; PHOSPHORUS; SILICON; STEEL; SULFUR;

EID: 4544283346     PISSN: 05848547     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sab.2004.06.001     Document Type: Article
Times cited : (53)

References (14)
  • 1
    • 33847085726 scopus 로고
    • Inductively coupled argon plasma as an ion source for mass spectrometric determination of trace elements
    • Houk R.S., Fassel V.A., Flesh G.D., Svec H.J., Gray A.L., Taylor C.E. Inductively coupled argon plasma as an ion source for mass spectrometric determination of trace elements. Anal. Chem. 52:1980;2283-2289.
    • (1980) Anal. Chem. , vol.52 , pp. 2283-2289
    • Houk, R.S.1    Fassel, V.A.2    Flesh, G.D.3    Svec, H.J.4    Gray, A.L.5    Taylor, C.E.6
  • 2
    • 0001914863 scopus 로고
    • Mass spectrometry of inductively coupled plasmas
    • Houk R.S. Mass spectrometry of inductively coupled plasmas. Anal. Chem. 58:1986;A97.
    • (1986) Anal. Chem. , vol.58
    • Houk, R.S.1
  • 3
    • 0037415622 scopus 로고    scopus 로고
    • Effectiveness of ammonia in reducing carbon-based polyatomic ion interferences in electrothermal vaporization collision cell inductively coupled plasma mass spectrometry
    • Ben-Younes M., Gregoire D.C., Chakrabarti C.L. Effectiveness of ammonia in reducing carbon-based polyatomic ion interferences in electrothermal vaporization collision cell inductively coupled plasma mass spectrometry. Spectrochim. Acta, Part B: Atom. Spectrosc. 58:2003;361-372.
    • (2003) Spectrochim. Acta, Part B: Atom. Spectrosc. , vol.58 , pp. 361-372
    • Ben-Younes, M.1    Gregoire, D.C.2    Chakrabarti, C.L.3
  • 4
    • 0036534687 scopus 로고    scopus 로고
    • Detection of ultratrace phosphorus and sulfur by quadrupole ICPMS with dynamic reaction cell
    • Bandura D.R., Baranov V.I., Tanner S.D. Detection of ultratrace phosphorus and sulfur by quadrupole ICPMS with dynamic reaction cell. Anal. Chem. 74:2002;1497-1502.
    • (2002) Anal. Chem. , vol.74 , pp. 1497-1502
    • Bandura, D.R.1    Baranov, V.I.2    Tanner, S.D.3
  • 5
    • 0030146157 scopus 로고    scopus 로고
    • Determination of trace amounts of sulfur in steel by electrothermal vaporization inductively coupled plasma mass spectrometry
    • Naka H., Gregoire D.C. Determination of trace amounts of sulfur in steel by electrothermal vaporization inductively coupled plasma mass spectrometry. J. Anal. At. Spectrom. 11:1996;359-363.
    • (1996) J. Anal. At. Spectrom. , vol.11 , pp. 359-363
    • Naka, H.1    Gregoire, D.C.2
  • 6
    • 0242335198 scopus 로고    scopus 로고
    • Determination of boron in high-purity sulfuric acid by ester generation and isotope dilution inductively coupled plasma mass spectrometry
    • Park C.J., Song S. Determination of boron in high-purity sulfuric acid by ester generation and isotope dilution inductively coupled plasma mass spectrometry. J. Anal. At. Spectrom. 18:2003;1248-1251.
    • (2003) J. Anal. At. Spectrom. , vol.18 , pp. 1248-1251
    • Park, C.J.1    Song, S.2
  • 7
    • 0037224716 scopus 로고    scopus 로고
    • Inductively coupled plasma quadrupole mass spectrometry for determination of silicon in steel
    • Liu H.-T., Jiang S.-J. Inductively coupled plasma quadrupole mass spectrometry for determination of silicon in steel. Spectrochim. Acta, Part B: Atom. Spectrosc. 58:2003;153-157.
    • (2003) Spectrochim. Acta, Part B: Atom. Spectrosc. , vol.58 , pp. 153-157
    • Liu, H.-T.1    Jiang, S.-J.2
  • 8
    • 1342277200 scopus 로고    scopus 로고
    • Determination of sulfur and selected trace elements in metallothionein-like proteins using capillary electrophoresis hyphenated to inductively coupled plasma mass spectrometry with an octopole reaction cell
    • Profrock D., Leonhard P., Prange A. Determination of sulfur and selected trace elements in metallothionein-like proteins using capillary electrophoresis hyphenated to inductively coupled plasma mass spectrometry with an octopole reaction cell. Anal. Bioanal. Chem. 377:2003;132-139.
    • (2003) Anal. Bioanal. Chem. , vol.377 , pp. 132-139
    • Profrock, D.1    Leonhard, P.2    Prange, A.3
  • 9
    • 0042850281 scopus 로고    scopus 로고
    • Determination of phosphorus in phosphorylated deoxyribonucleotides using capillary electrophoresis and high performance liquid chromatography hyphenated to inductively coupled plasma mass spectrometry with an octopole reaction cell
    • Profrock D., Leonhard P., Prange A. Determination of phosphorus in phosphorylated deoxyribonucleotides using capillary electrophoresis and high performance liquid chromatography hyphenated to inductively coupled plasma mass spectrometry with an octopole reaction cell. J. Anal. At. Spectrom. 18:2003;708-713.
    • (2003) J. Anal. At. Spectrom. , vol.18 , pp. 708-713
    • Profrock, D.1    Leonhard, P.2    Prange, A.3
  • 10
    • 0141887384 scopus 로고    scopus 로고
    • Use of optional gas and collision cell for enhanced sensitivity of the organophosphorus pesticides by GC-ICP-MS
    • Vonderheide A.P., Meija J., Montes-Bayon M., Caruso J.A. Use of optional gas and collision cell for enhanced sensitivity of the organophosphorus pesticides by GC-ICP-MS. J. Anal. At. Spectrom. 18:2003;1097-1102.
    • (2003) J. Anal. At. Spectrom. , vol.18 , pp. 1097-1102
    • Vonderheide, A.P.1    Meija, J.2    Montes-Bayon, M.3    Caruso, J.A.4
  • 11
    • 1542652194 scopus 로고    scopus 로고
    • Determination of the ratio of calcium to phosphorus in foodstuffs by dynamic reaction cell inductively coupled plasma mass spectrometry
    • Wu M.-C., Jiang S.-J., Hsi T.-S. Determination of the ratio of calcium to phosphorus in foodstuffs by dynamic reaction cell inductively coupled plasma mass spectrometry. Anal. Bioanal. Chem. 377:2003;154-158.
    • (2003) Anal. Bioanal. Chem. , vol.377 , pp. 154-158
    • Wu, M.-C.1    Jiang, S.-J.2    Hsi, T.-S.3
  • 12
    • 0345735400 scopus 로고    scopus 로고
    • Determination of sulfur-containing amino acids by capillary electrophoresis dynamic reaction cell inductively coupled plasma mass spectrometry
    • Yeh C.-F., Jiang S.-J., Hsi T.-S. Determination of sulfur-containing amino acids by capillary electrophoresis dynamic reaction cell inductively coupled plasma mass spectrometry. Anal. Chim. Acta. 502:2004;57-63.
    • (2004) Anal. Chim. Acta , vol.502 , pp. 57-63
    • Yeh, C.-F.1    Jiang, S.-J.2    Hsi, T.-S.3
  • 13
    • 0032649974 scopus 로고    scopus 로고
    • Determination of sulfur isotope ratios and concentrations in water samples using ICP-MS incorporating hexapole ion optics
    • Mason P.R.D., Kaspers K., van Bergen M.J. Determination of sulfur isotope ratios and concentrations in water samples using ICP-MS incorporating hexapole ion optics. J. Anal. At. Spectrom. 14:1999;1067-1074.
    • (1999) J. Anal. At. Spectrom. , vol.14 , pp. 1067-1074
    • Mason, P.R.D.1    Kaspers, K.2    Van Bergen, M.J.3
  • 14
    • 3042547045 scopus 로고    scopus 로고
    • Sensitive, simultaneous determination of P, S, Cl, Br and I containing pesticides in environmental samples by GC hyphenated with collision-cell ICP-MS
    • Profrock D., Leonhard P., Wilbur S., Prange A. Sensitive, simultaneous determination of P, S, Cl, Br and I containing pesticides in environmental samples by GC hyphenated with collision-cell ICP-MS. J. Anal. At. Spectrom. 19:2004;623-631.
    • (2004) J. Anal. At. Spectrom. , vol.19 , pp. 623-631
    • Profrock, D.1    Leonhard, P.2    Wilbur, S.3    Prange, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.