메뉴 건너뛰기




Volumn 51, Issue 4 I, 2004, Pages 1812-1816

Imaging performance of mercuric iodide polycrystalline films

Author keywords

Detector; Digital X ray; Mercuric iodide; Polycrystalline; X ray; X ray imaging

Indexed keywords

DIGITAL X-RAY DETECTORS; MERCURIC IODIDES; POLYCRYSTALLINE FILMS; X-RAY IMAGING;

EID: 4444227416     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2004.832691     Document Type: Conference Paper
Times cited : (30)

References (19)
  • 1
    • 0003729860 scopus 로고
    • An update on the frequency of medical and dental X-ray examinations in Great Britain - 1983
    • National Radiological Protection Board (Britain), Harwell, U.K
    • B. F. Wall, M. C. Hillier, and G. M. Kendall, "An Update on the Frequency of Medical and Dental X-Ray Examinations in Great Britain - 1983," National Radiological Protection Board (Britain), Harwell, U.K., Tech. Rep. NRPB-R201, 1986.
    • (1986) Tech. Rep. , vol.NRPB-R201
    • Wall, B.F.1    Hillier, M.C.2    Kendall, G.M.3
  • 2
    • 0036035340 scopus 로고    scopus 로고
    • Depth-dependent phosphor blur in indirect X-ray imaging sensors
    • A. Badano and R. Leimbach, "Depth-dependent phosphor blur in indirect X-ray imaging sensors," Proc. SPIE, vol. 4682, pp. 94-106, 2002.
    • (2002) Proc. SPIE , vol.4682 , pp. 94-106
    • Badano, A.1    Leimbach, R.2
  • 3
    • 0031029041 scopus 로고    scopus 로고
    • X-ray detectors for digital radiography
    • M. J. Yaffe and J. A. Rowlands, "X-ray detectors for digital radiography," Phys. Med. Biol., vol. 42, pp. 1-39, 1997.
    • (1997) Phys. Med. Biol. , vol.42 , pp. 1-39
    • Yaffe, M.J.1    Rowlands, J.A.2
  • 4
    • 77957015149 scopus 로고
    • Characterization and quantification of detector performance
    • T. E. Schlesinger et al., Eds. San Diego, CA: Academic
    • V. M. Gerrish et al., "Characterization and quantification of detector performance," in Semiconductors for Room Temperature Nuclear Detector Applications, 1st ed, T. E. Schlesinger et al., Eds. San Diego, CA: Academic, 1995, pp. 493-530.
    • (1995) Semiconductors for Room Temperature Nuclear Detector Applications, 1st Ed , pp. 493-530
    • Gerrish, V.M.1
  • 12
    • 0029359357 scopus 로고
    • Mercuric iodide detector systems for identifying substances by X-ray energy dispersive diffraction
    • J. S. Iwanczyk, B. E. Patt, Y. J. Wang, M. Croft, Z. Kalman, and W. Mayo, "Mercuric iodide detector systems for identifying substances by X-ray energy dispersive diffraction," IEEE Trans. Nucl. Sci., vol. 42, pp. 606-610, 1995.
    • (1995) IEEE Trans. Nucl. Sci. , vol.42 , pp. 606-610
    • Iwanczyk, J.S.1    Patt, B.E.2    Wang, Y.J.3    Croft, M.4    Kalman, Z.5    Mayo, W.6
  • 13
    • 0027290307 scopus 로고
    • Mercuric iodide X-ray detectors for space applications
    • J. S. Iwanczyk, "Mercuric iodide X-ray detectors for space applications," in Proc. Mater. Res. Soc. Symp., vol. 302, 1993, pp. 79-88.
    • (1993) Proc. Mater. Res. Soc. Symp. , vol.302 , pp. 79-88
    • Iwanczyk, J.S.1
  • 18
    • 0020151635 scopus 로고
    • Review of mercuric iodide development program in Santa Barbara
    • H. A. Lamonds, "Review of mercuric iodide development program in Santa Barbara," Nucl. Instrum. Methods, vol. 213, pp. 5-12, 1983.
    • (1983) Nucl. Instrum. Methods , vol.213 , pp. 5-12
    • Lamonds, H.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.