메뉴 건너뛰기




Volumn 41, Issue 8, 2008, Pages 2898-2907

Structure transition in PSS/lysozyme complexes: A chain-conformation-driven process, as directly seen by small angle neutron scattering

Author keywords

[No Author keywords available]

Indexed keywords

COMPLEXATION; CONCENTRATION (PROCESS); CONFORMATIONS; CROSSLINKING; NEUTRON SCATTERING; POLYELECTROLYTES;

EID: 43649102180     PISSN: 00249297     EISSN: None     Source Type: Journal    
DOI: 10.1021/ma702242d     Document Type: Article
Times cited : (39)

References (38)
  • 1
    • 0013287967 scopus 로고    scopus 로고
    • Physical chemistry of polyelectrolytes
    • Radeva, T, Ed, Dekker: New York, Chapter 19, pp
    • Tribet, C. Physical chemistry of polyelectrolytes; Radeva, T., Ed.; Surfactant Science Series; M. Dekker: New York, 1999; Chapter 19, pp 687-741.
    • (1999) Surfactant Science Series , vol.1000 , pp. 687-741
    • Tribet, C.1
  • 27
    • 43649106809 scopus 로고    scopus 로고
    • Makowski, H. S, Lundberg, R. D, Singhal, G. S, EXXON Research and Engineering Co, U.S. Patent 3,870,841, 1975
    • Makowski, H. S.; Lundberg, R. D.; Singhal, G. S. (EXXON Research and Engineering Co.) U.S. Patent 3,870,841, 1975.
  • 32
    • 43649089203 scopus 로고    scopus 로고
    • We used long recording times to get very small statistical errors (error bars are smaller than symbols in Figures 3, 5, and 6, Then, we have to determine the error resulting from the zero φD extrapolation, made by linear fitting of I(q)/φD at each value of q. For that, we try to be as exacting as possible and use the two zero extrapolations corresponding, respectively, to the highest slope and the lowest slope which can be drawn through the data points. We have sometimes rejected some experimental values for the lowest ΦD (0.25, mostly because a small difference in sample preparation could affect the scattering too much e.g, for pure polyelectrolyte solutions, see Figure 3, Error bars are larger when the structure factor has a larger effect on the total scattering, i.e, for the globular structure
    • D (0.25), mostly because a small difference in sample preparation could affect the scattering too much (e.g., for pure polyelectrolyte solutions, see Figure 3). Error bars are larger when the structure factor has a larger effect on the total scattering, i.e., for the globular structure.
  • 36
    • 43649096506 scopus 로고    scopus 로고
    • -1. This is the value we used to fit data in absolute scale.
    • -1. This is the value we used to fit data in absolute scale.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.