Potential benefits of eliminating target volume expansions for patients' breathing in the treatment of liver tumours
Haken R et al 1997 Potential benefits of eliminating target volume expansions for patients' breathing in the treatment of liver tumours Int. J. Radiat. Oncol. Biol. Phys. 38 613-7
Deep inspiration breath hold technique for lung tumours: The potential value of target immobilization and reduced lung density in dose escalation
Hanley J et al 1999 Deep inspiration breath hold technique for lung tumours: the potential value of target immobilization and reduced lung density in dose escalation Int. J. Radiat. Oncol. Biol. Phys. 45 603-11
Biophysical characteristics of HIMAC clinical irradiation system for heavy-ion radiation therapy
Kanai T et al 1999 Biophysical characteristics of HIMAC clinical irradiation system for heavy-ion radiation therapy Int. J. Radiat. Oncol. Biol. Phys. 44 201-10
Treatment planning for heavy ion radiotherapy: Calculation and optimization of biologically effective dose
Kraemer M and Scholz M 2000 Treatment planning for heavy ion radiotherapy: calculation and optimization of biologically effective dose Phys. Med. Biol. 45 3319-30
Computer simulations concerning influence of target motion on dose distribution delivered by the GSI raster scanner
Li Q et al 2001 Computer simulations concerning influence of target motion on dose distribution delivered by the GSI raster scanner GSI Scientific Report 2000 p 162
Computer systems and mechanical tools for stereotactically guided conformation therapy with linear accelerators
Schlegel W et al 1992 Computer systems and mechanical tools for stereotactically guided conformation therapy with linear accelerators Int. J. Radiat. Oncol. Biol. Phys. 24 781-7
Radiotherapy for chordomas and low-grade chondrosarcomas of the skull base with carbon ions
Schulz-Ertner D et al 2002 Radiotherapy for chordomas and low-grade chondrosarcomas of the skull base with carbon ions Int. J. Radiat. Oncol. Biol. Phys. 53 36-42
High-speed magnetic resonance imaging for four-dimensional treatment planning of conformal radiotherapy of moving body tumours
Shimizu S et al 2000 High-speed magnetic resonance imaging for four-dimensional treatment planning of conformal radiotherapy of moving body tumours Int. J. Radiat. Oncol. Biol. Phys. 48 471-4
Three-dimensional dose verification with x-ray films in conformal carbon ion therapy
Spielberger B, Kraemer M and Kraft G 2003a Three-dimensional dose verification with x-ray films in conformal carbon ion therapy Phys. Med. Biol. 48 497-505
Three-dimensional dose verification in complex particle radiation fields based on x-ray films
Spielberger B et al 2003b Three-dimensional dose verification in complex particle radiation fields based on x-ray films Nucl. Instrum. Methods B 209 277-82
The use of active breathing control to minimize breathing motion during radiation therapy
Wong J et al 1999 The use of active breathing control to minimize breathing motion during radiation therapy Int. J. Radiat. Oncol. Biol. Phys. 44 911-9
The effect of intra-fraction organ motion on the delivery of dynamic intensity modulation
Yu C X, Jaffray D A and Wong J W 1998 The effect of intra-fraction organ motion on the delivery of dynamic intensity modulation Phys. Med. Biol. 43 91-104