메뉴 건너뛰기




Volumn 46, Issue 4, 2001, Pages 1101-1116

Treatment planning for heavy ion radiotherapy: Clinical implementation and application

Author keywords

[No Author keywords available]

Indexed keywords

ION BEAMS; OPTIMIZATION; TOMOGRAPHY; TUMORS;

EID: 0035058903     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/46/4/314     Document Type: Article
Times cited : (124)

References (25)
  • 1
    • 0005248031 scopus 로고    scopus 로고
    • The spherical view-a tool for interactive optimization of irradiation directions Proc. 12th Int. Conf. on the Use of Computers in Radiation Therapy ed D Leavitt and G Starkschall (Madison, WI: Medical Physics Publishing)
    • (1997) , pp. 302
    • Bendl, R.1    Keller-Reichenbecher, M.A.2    Höss, A.3    Schlegel, W.4
  • 8
    • 0021851642 scopus 로고
    • Calculation of the uncertainty in the dose delivered during radiation therapy
    • (1985) Med. Phys. , vol.12 , pp. 608-612
    • Goitein, M.1
  • 16
    • 0031657115 scopus 로고    scopus 로고
    • Heavy-ion therapy at GSI
    • (1998) Phys. Med. , vol.14 , Issue.SUPPL. I , pp. 86-90
    • Kraft, G.1
  • 18
  • 19
    • 0005248607 scopus 로고    scopus 로고
    • Digital projection images and reconstructed slice images for treatment planning and position verification PhD Thesis Heidelberg
    • (1999)
    • Kress, J.1
  • 21
    • 0028891524 scopus 로고
    • The 200-MeV proton therapy project at the Paul Scherrer Institute: Conceptual design and practical realization
    • (1993) Med. Phys. , vol.22 , pp. 37-53
    • Pedroni, E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.