Polymethylmethacrylate augmentation of pedicle screw for osteoporotic spinal surgery: A novel technique

Author keywords

Osteoporosis; Pedicle screw augmentation; Polymethylmethacrylate

Indexed keywords

ANTIBIOTIC AGENT; POLY(METHYL METHACRYLATE);

EID: 43049086332     PISSN: 03622436     EISSN: 15281159     Source Type: Journal    
DOI: 10.1097/BRS.0b013e31816f6c73     Document Type: Article
Times cited : (156)

References (29)
  • 1
    • 0028034777 scopus 로고
    • Effects of bone mineral density on pedicle screw fixation
    • Halverson TL, Kelley LA, Thomas KA, et al. Effects of bone mineral density on pedicle screw fixation. Spine 1994;19:2415-20.
    • (1994) Spine , vol.19 , pp. 2415-2420
    • Halverson, T.L.1    Kelley, L.A.2    Thomas, K.A.3
  • 2
    • 0031415073 scopus 로고    scopus 로고
    • The effect of bone quality on pedicle screw loading in axial instability. A synthetic model
    • Mclain RF, McKinley TO, Yerby SA, et al. The effect of bone quality on pedicle screw loading in axial instability. A synthetic model. Spine 1997;22:1454-60.
    • (1997) Spine , vol.22 , pp. 1454-1460
    • Mclain, R.F.1    McKinley, T.O.2    Yerby, S.A.3
  • 3
    • 0035893832 scopus 로고    scopus 로고
    • Augmentation of anterior vertebral body screw fixation by an injectable, biodegradable calcium phosphate bone substitute
    • Bai B, Kummer FJ, Spivak J. Augmentation of anterior vertebral body screw fixation by an injectable, biodegradable calcium phosphate bone substitute. Spine 2001;26:24:2679-83.
    • (2001) Spine , vol.26 , Issue.24 , pp. 2679-2683
    • Bai, B.1    Kummer, F.J.2    Spivak, J.3
  • 4
    • 33746503209 scopus 로고    scopus 로고
    • Biomechanical comparison of anatomic trajectory pedicle screw versus injectable calcium sulfate graft-augmented pedicle screw for salvage in cadaveric thoracic bone
    • Derincek A, Wu C, Mehbod A, et al. Biomechanical comparison of anatomic trajectory pedicle screw versus injectable calcium sulfate graft-augmented pedicle screw for salvage in cadaveric thoracic bone. J Spinal Disord Tech 2006;19:286-91.
    • (2006) J Spinal Disord Tech , vol.19 , pp. 286-291
    • Derincek, A.1    Wu, C.2    Mehbod, A.3
  • 5
    • 0036979104 scopus 로고    scopus 로고
    • Bone cement or bone substitute augmentation of pedicle screws improves pullout strength in posterior spinal fixation
    • Evans SL, Hunt CM, Ahuja S. Bone cement or bone substitute augmentation of pedicle screws improves pullout strength in posterior spinal fixation. J Mater Sci Meter Med 2002;13:1143-5.
    • (2002) J Mater Sci Meter Med , vol.13 , pp. 1143-1145
    • Evans, S.L.1    Hunt, C.M.2    Ahuja, S.3
  • 6
    • 33645308310 scopus 로고    scopus 로고
    • The mechanics of polymethylmethacrylate augmentation
    • Kayanja M, Evans K, Milks R, et al. The mechanics of polymethylmethacrylate augmentation. Clin Orthop Relat Res 2006;443:124-30.
    • (2006) Clin Orthop Relat Res , vol.443 , pp. 124-130
    • Kayanja, M.1    Evans, K.2    Milks, R.3
  • 7
    • 33746442572 scopus 로고    scopus 로고
    • Stability of pedicle screw after kyphoplasty augmentation-an experimental study to compare transpedicular screw fixation in soft and cured kyphoplasty cement
    • Linhardt O, Lüring C, Matussek J, et al. Stability of pedicle screw after kyphoplasty augmentation-an experimental study to compare transpedicular screw fixation in soft and cured kyphoplasty cement. J Spinal Disord Tech 2006;19:87-91.
    • (2006) J Spinal Disord Tech , vol.19 , pp. 87-91
    • Linhardt, O.1    Lüring, C.2    Matussek, J.3
  • 8
    • 0031416028 scopus 로고    scopus 로고
    • Carbonated apatite cement augmentation of pedicle screw fixation in the lumbar spine
    • Lotz JC, Hu SS, Chiu DFM, et al. Carbonated apatite cement augmentation of pedicle screw fixation in the lumbar spine. Spine 1997;22:2716-23.
    • (1997) Spine , vol.22 , pp. 2716-2723
    • Lotz, J.C.1    Hu, S.S.2    Chiu, D.F.M.3
  • 9
    • 0023039361 scopus 로고
    • Failure of stabilization of the spine with methylmethacrylate: A retrospective analysis of twenty-four cases
    • McAfee PC, Bohlman HH, Ducker T, et al. Failure of stabilization of the spine with methylmethacrylate: a retrospective analysis of twenty-four cases. J Bone Joint Surg Am 1986;68:1145-57.
    • (1986) J Bone Joint Surg Am , vol.68 , pp. 1145-1157
    • McAfee, P.C.1    Bohlman, H.H.2    Ducker, T.3
  • 10
    • 0031424553 scopus 로고    scopus 로고
    • Restoration of pedicle screw fixation with an in situ setting calcium phosphate cement
    • Moore DC, Maitra RS, Farjo LA, et al. Restoration of pedicle screw fixation with an in situ setting calcium phosphate cement. Spine 1997;22:1696-705.
    • (1997) Spine , vol.22 , pp. 1696-1705
    • Moore, D.C.1    Maitra, R.S.2    Farjo, L.A.3
  • 11
    • 3042742564 scopus 로고    scopus 로고
    • Augmentation of pedicle screw fixation strength using an injectable calcium phosphate cement as a function of injection timing and method
    • Renner SM, Lim TH, Kim WJ, et al. Augmentation of pedicle screw fixation strength using an injectable calcium phosphate cement as a function of injection timing and method. Spine 2004;29:E212-E216.
    • (2004) Spine , vol.29
    • Renner, S.M.1    Lim, T.H.2    Kim, W.J.3
  • 12
    • 0037043468 scopus 로고    scopus 로고
    • Evaluation of calcium sulfate paste for augmentation of lumbar pedicle screw pullout strength
    • Rohmiller T, Schwalm D, Glattes RC, et al. Evaluation of calcium sulfate paste for augmentation of lumbar pedicle screw pullout strength. Spine 2002;2:255-60.
    • (2002) Spine , vol.2 , pp. 255-260
    • Rohmiller, T.1    Schwalm, D.2    Glattes, R.C.3
  • 13
    • 0036128620 scopus 로고    scopus 로고
    • Increased pedicle screw pull out strength with vertebroplasty augmentation in osteoporotic spines
    • Sarzier JS, Evans AJ, Cahill DW. Increased pedicle screw pull out strength with vertebroplasty augmentation in osteoporotic spines. J Neurosurg 2002;96:309-12.
    • (2002) J Neurosurg , vol.96 , pp. 309-312
    • Sarzier, J.S.1    Evans, A.J.2    Cahill, D.W.3
  • 14
    • 14844350615 scopus 로고    scopus 로고
    • Biomechanical analysis of anterior polymethylmethacrylate reconstruction following total spondylectomy for metastatic disease
    • Shannon FJ, DiResta GR, Ottaviano D, et al. Biomechanical analysis of anterior polymethylmethacrylate reconstruction following total spondylectomy for metastatic disease. Spine 2004;19:2096-102.
    • (2004) Spine , vol.19 , pp. 2096-2102
    • Shannon, F.J.1    DiResta, G.R.2    Ottaviano, D.3
  • 15
    • 0037231526 scopus 로고    scopus 로고
    • Hydroxyapatite composite resin cement augmentation of pedicle screw fixation
    • Turner AWL, Gillies RM, Svehla MJ, et al. Hydroxyapatite composite resin cement augmentation of pedicle screw fixation. Clin Orthop Relat Res 2003;406:253-61.
    • (2003) Clin Orthop Relat Res , vol.406 , pp. 253-261
    • Turner, A.W.L.1    Gillies, R.M.2    Svehla, M.J.3
  • 16
    • 0027426783 scopus 로고
    • Effect of screw diameter, insertion technique, and bone cement augmentation of pedicular screw fixation strength
    • Wittenberg RH, Lee KS, Shea M, et al. Effect of screw diameter, insertion technique, and bone cement augmentation of pedicular screw fixation strength. Clin Orthop Relat Res 1993;296:278-87.
    • (1993) Clin Orthop Relat Res , vol.296 , pp. 278-287
    • Wittenberg, R.H.1    Lee, K.S.2    Shea, M.3
  • 17
    • 0034528813 scopus 로고    scopus 로고
    • Augmentation of (pedicle) screws with calcium apatite cement in patients with severe progressive osteoporotic spinal deformities: An innovative technique
    • Wuisman PIJM, Dijk MV, Heleen S, et al. Augmentation of (pedicle) screws with calcium apatite cement in patients with severe progressive osteoporotic spinal deformities: an innovative technique. Eur Spine J 2000;9:528-33.
    • (2000) Eur Spine J , vol.9 , pp. 528-533
    • Wuisman, P.I.J.M.1    Dijk, M.V.2    Heleen, S.3
  • 18
    • 0032143033 scopus 로고    scopus 로고
    • Revision of failed pedicle screws using hydroxyapatite cement: A biomechanical analysis
    • Yerby SA, Toh E, McLain RF. Revision of failed pedicle screws using hydroxyapatite cement: a biomechanical analysis. Spine 1998;23:1657-61.
    • (1998) Spine , vol.23 , pp. 1657-1661
    • Yerby, S.A.1    Toh, E.2    McLain, R.F.3
  • 19
    • 33747847098 scopus 로고    scopus 로고
    • Augmentation of a loosened sacral pedicle screw with percutaneous polymethylmethacrylate injection
    • Yilmaz C, Atalay B, Caner H, et al. Augmentation of a loosened sacral pedicle screw with percutaneous polymethylmethacrylate injection. J Spinal Disord Tech 2006;19:373-5.
    • (2006) J Spinal Disord Tech , vol.19 , pp. 373-375
    • Yilmaz, C.1    Atalay, B.2    Caner, H.3
  • 20
    • 0022628372 scopus 로고
    • A biomechanical study of intrapedicular screw fixation in the lumbarsacral spine
    • Zindrick MR, Wiltse LL, Widell EH, et al. A biomechanical study of intrapedicular screw fixation in the lumbarsacral spine. Clin Orthop Relat Res 1986;203:99-112.
    • (1986) Clin Orthop Relat Res , vol.203 , pp. 99-112
    • Zindrick, M.R.1    Wiltse, L.L.2    Widell, E.H.3
  • 21
    • 0037278975 scopus 로고    scopus 로고
    • Leakage of cement in percutaneous transpedicular vertebroplasty for painful osteoporotic compression fractures
    • Yeom JS, Kim WJ, Choy WS, et al. Leakage of cement in percutaneous transpedicular vertebroplasty for painful osteoporotic compression fractures. J Bone Joint Surg Br 2003;85:83-9.
    • (2003) J Bone Joint Surg Br , vol.85 , pp. 83-89
    • Yeom, J.S.1    Kim, W.J.2    Choy, W.S.3
  • 22
    • 0031431778 scopus 로고    scopus 로고
    • Augmentation of osteoporotic vertebral bodies
    • Bostrom MPG, Lane JM. Augmentation of osteoporotic vertebral bodies. Spine 1997;22:S38-S42.
    • (1997) Spine , vol.22
    • Bostrom, M.P.G.1    Lane, J.M.2
  • 23
    • 3342928907 scopus 로고    scopus 로고
    • Biomechanical study of pedicle screw fixation in severely osteoporotic bone
    • Cook SD, Salkeld SL, Stanley T, et al. Biomechanical study of pedicle screw fixation in severely osteoporotic bone. Spine 2004;4:402-8.
    • (2004) Spine , vol.4 , pp. 402-408
    • Cook, S.D.1    Salkeld, S.L.2    Stanley, T.3
  • 24
    • 0021885570 scopus 로고
    • The effect of adjunctive methylmethacrylate on failures of fixation and function in patients with intertrochanteric fractures and osteoporosis
    • Bartucci EJ, Gonzalez MH, Cooperman DR, et al. The effect of adjunctive methylmethacrylate on failures of fixation and function in patients with intertrochanteric fractures and osteoporosis. J Bone Joint Surg Am 1985;67:1094-107.
    • (1985) J Bone Joint Surg Am , vol.67 , pp. 1094-1107
    • Bartucci, E.J.1    Gonzalez, M.H.2    Cooperman, D.R.3
  • 25
    • 0034120513 scopus 로고    scopus 로고
    • Charnley total hip arthroplasty with cement: Minimum twenty-five-year follow-up
    • Callaghan JJ, Albright JC, Goetz DD, et al. Charnley total hip arthroplasty with cement: minimum twenty-five-year follow-up. J Bone Joint Surg Am 2000;82:487-97.
    • (2000) J Bone Joint Surg Am , vol.82 , pp. 487-497
    • Callaghan, J.J.1    Albright, J.C.2    Goetz, D.D.3
  • 26
    • 0028314201 scopus 로고
    • Repair of failed transpedicle screw fixation-A biomechanical study comparing polymethylmethacrylate, milled bone, and matchstick bone reconstruction
    • Pfeifer BA, Krag MH, Johnson C. Repair of failed transpedicle screw fixation-A biomechanical study comparing polymethylmethacrylate, milled bone, and matchstick bone reconstruction. Spine 1994;19:350-3.
    • (1994) Spine , vol.19 , pp. 350-353
    • Pfeifer, B.A.1    Krag, M.H.2    Johnson, C.3
  • 27
    • 4043151569 scopus 로고    scopus 로고
    • Pedicle screw motion in the osteoporotic spine after augmentation with laminar hooks, sublaminar wires, or calcium phosphate cement: A comparative analysis
    • Tan JS, Kwon BK, Dvorak MF, et al. Pedicle screw motion in the osteoporotic spine after augmentation with laminar hooks, sublaminar wires, or calcium phosphate cement: a comparative analysis. Spine 2004;29:1723-30.
    • (2004) Spine , vol.29 , pp. 1723-1730
    • Tan, J.S.1    Kwon, B.K.2    Dvorak, M.F.3
  • 28
    • 43049143237 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty using calcium sulfate
    • Taiwan Orthopedic Association Oct
    • Chen WJ, Chen LH, Chen WJ, et al. Percutaneous vertebroplasty using calcium sulfate. Proceedings of 51st Annual meeting, Taiwan Orthopedic Association Oct 2006;173.
    • (2006) Proceedings of 51st Annual meeting , pp. 173
    • Chen, W.J.1    Chen, L.H.2    Chen, W.J.3
  • 29
    • 0030911539 scopus 로고    scopus 로고
    • An experimental study of a combination method using a pedicle screw and laminar hook for the oeteoporotic spine
    • Hasegawa K, Takahashi HE, Uchiyama S, et al. An experimental study of a combination method using a pedicle screw and laminar hook for the oeteoporotic spine. Spine 1997;22:958-63.
    • (1997) Spine , vol.22 , pp. 958-963
    • Hasegawa, K.1    Takahashi, H.E.2    Uchiyama, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.