-
1
-
-
0031424553
-
Restoration of pedicle screw fixation with an in situ setting calcium phosphate cement
-
Moore DC, Maitra RS, Farjo LA, et al. Restoration of pedicle screw fixation with an in situ setting calcium phosphate cement. Spine. 1997;22:1696-1705.
-
(1997)
Spine
, vol.22
, pp. 1696-1705
-
-
Moore, D.C.1
Maitra, R.S.2
Farjo, L.A.3
-
2
-
-
0029609525
-
Internal fixation (pedicle screw fixation) for fusions of the lumbar spine
-
Vaccaro AR, Garfin SR. Internal fixation (pedicle screw fixation) for fusions of the lumbar spine. Spine. 1995;15(Suppl 24):157-165.
-
(1995)
Spine
, vol.15
, Issue.24 SUPPL.
, pp. 157-165
-
-
Vaccaro, A.R.1
Garfin, S.R.2
-
3
-
-
0036128620
-
Increased pedicle screw pullout strength with vertebroplasty augmentation in osteoporotic spines
-
Sarzier JS, Evans AJ, Cahill DW. Increased pedicle screw pullout strength with vertebroplasty augmentation in osteoporotic spines. J Neurosurg Spine. 2002;96:309-312.
-
(2002)
J Neurosurg Spine
, vol.96
, pp. 309-312
-
-
Sarzier, J.S.1
Evans, A.J.2
Cahill, D.W.3
-
4
-
-
0032143033
-
Revision of failed pedicle screws using hydroxyapatite cement. A biomechanical analysis
-
Yerby SA, Toh E, McLain RF. Revision of failed pedicle screws using hydroxyapatite cement. A biomechanical analysis. Spine. 1998;23:1657-1661.
-
(1998)
Spine
, vol.23
, pp. 1657-1661
-
-
Yerby, S.A.1
Toh, E.2
McLain, R.F.3
-
5
-
-
0027979920
-
Percutaneous vertebroplasty guided by a combination of CT and fluoroscopy
-
Gangi A, Kastler BA, Dietemann JL. Percutaneous vertebroplasty guided by a combination of CT and fluoroscopy. AJNR Am J Neuroradiol. 1994;15:83-86.
-
(1994)
AJNR Am J Neuroradiol
, vol.15
, pp. 83-86
-
-
Gangi, A.1
Kastler, B.A.2
Dietemann, J.L.3
-
6
-
-
0031545893
-
Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: Technical aspects
-
Jensen ME, Evans AJ, Mathis JM, et al. Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: Technical aspects. AJNR Am J Neuroradiol. 1997;18:1897-1904.
-
(1997)
AJNR Am J Neuroradiol
, vol.18
, pp. 1897-1904
-
-
Jensen, M.E.1
Evans, A.J.2
Mathis, J.M.3
-
7
-
-
0035879089
-
New technologies in spine
-
Garfin S, Hansen A, Reiley M. New technologies in spine. Spine. 2001;14:1511-1515.
-
(2001)
Spine
, vol.14
, pp. 1511-1515
-
-
Garfin, S.1
Hansen, A.2
Reiley, M.3
-
9
-
-
0024363897
-
Effect of preservation medium on the mechanical properties of cat bones
-
James C, Goh H, Ang J, et al. Effect of preservation medium on the mechanical properties of cat bones. Acta Orthop Scand. 1989;60:465-467.
-
(1989)
Acta Orthop Scand
, vol.60
, pp. 465-467
-
-
James, C.1
Goh, H.2
Ang, J.3
-
10
-
-
0025153831
-
Influence of bone mineral density on the fixation of thoracolumbar implants. A comparative study of transpedicular screws, laminar hooks, and spinous process wires
-
Coe JD, Warden KE, Herzig MA. Influence of bone mineral density on the fixation of thoracolumbar implants. A comparative study of transpedicular screws, laminar hooks, and spinous process wires. Spine. 1990;15:902-907.
-
(1990)
Spine
, vol.15
, pp. 902-907
-
-
Coe, J.D.1
Warden, K.E.2
Herzig, M.A.3
-
11
-
-
0027365874
-
Stability of transpedicular screwing for the osteoporotic spine. An in vitro study of the mechanical stability
-
Okuyama K, Sato K, Abe E. Stability of transpedicular screwing for the osteoporotic spine. An in vitro study of the mechanical stability. Spine. 1993;8:2240-2245.
-
(1993)
Spine
, vol.8
, pp. 2240-2245
-
-
Okuyama, K.1
Sato, K.2
Abe, E.3
-
12
-
-
0025988460
-
An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine
-
Soshi S, Shiba R, Kondo H, et al. An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine. Spine. 1991;16:1335-1341.
-
(1991)
Spine
, vol.16
, pp. 1335-1341
-
-
Soshi, S.1
Shiba, R.2
Kondo, H.3
-
13
-
-
0026505213
-
Mechanical stability of the pedicle screw fixation systems for the lumbar spine
-
Yamagata M, Kitahara H, Minami S. Mechanical stability of the pedicle screw fixation systems for the lumbar spine. Spine. 1992;7:51-54.
-
(1992)
Spine
, vol.7
, pp. 51-54
-
-
Yamagata, M.1
Kitahara, H.2
Minami, S.3
-
14
-
-
3042742564
-
Augmentation of pedicle screw fixation strength using an injectable calcium phosphate cement as a function of injection timing and method
-
Renner S, Lim T, Kim W, et al. Augmentation of pedicle screw fixation strength using an injectable calcium phosphate cement as a function of injection timing and method. Spine. 2004;29:212-216.
-
(2004)
Spine
, vol.29
, pp. 212-216
-
-
Renner, S.1
Lim, T.2
Kim, W.3
-
15
-
-
0022628372
-
A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine
-
Zindrick MR, Wiltse LL, Widell EH. A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine. Clin Orthop. 1986;203:99-112.
-
(1986)
Clin Orthop
, vol.203
, pp. 99-112
-
-
Zindrick, M.R.1
Wiltse, L.L.2
Widell, E.H.3
-
16
-
-
0022653406
-
Techniques of internal fixation for degenerative conditions of the lumbar spine
-
Kostuik JP, Errico TJ, Gleason TF. Techniques of internal fixation for degenerative conditions of the lumbar spine. Clin Orthop. 1986;203:219-231.
-
(1986)
Clin Orthop
, vol.203
, pp. 219-231
-
-
Kostuik, J.P.1
Errico, T.J.2
Gleason, T.F.3
-
17
-
-
0028314201
-
Repair of failed transpedicular screw fixation: A biomechanical study comparing polymethylmethacrylate, milled bone, and matchstick bone reconstruction
-
Pfeifer BA, Krag MH, Johnson C. Repair of failed transpedicular screw fixation: A biomechanical study comparing polymethylmethacrylate, milled bone, and matchstick bone reconstruction. Spine. 1994;19:350-353.
-
(1994)
Spine
, vol.19
, pp. 350-353
-
-
Pfeifer, B.A.1
Krag, M.H.2
Johnson, C.3
-
18
-
-
0022471987
-
Roy-Camille plates in unstable spinal conditions. A preliminary report
-
Kinnard P, Ghibely A, Gordon D. Roy-Camille plates in unstable spinal conditions. A preliminary report. Spine. 1986;11:131-135.
-
(1986)
Spine
, vol.11
, pp. 131-135
-
-
Kinnard, P.1
Ghibely, A.2
Gordon, D.3
-
19
-
-
0022642420
-
Segmental spine plates with pedicle screw fixation. A new internal fixation device for disorders of the lumbar and thoracolumbar spine
-
Steffee AD, Biscup RS, Sitkowski DJ. Segmental spine plates with pedicle screw fixation. A new internal fixation device for disorders of the lumbar and thoracolumbar spine. Clin Orthop. 1986;203:45-53.
-
(1986)
Clin Orthop
, vol.203
, pp. 45-53
-
-
Steffee, A.D.1
Biscup, R.S.2
Sitkowski, D.J.3
-
20
-
-
0344740571
-
Bone cements and fillers: A review
-
Kenny SM, Buggy M. Bone cements and fillers: a review. J Mater Sci Mater Med. 1993;14:923-938.
-
(1993)
J Mater Sci Mater Med
, vol.14
, pp. 923-938
-
-
Kenny, S.M.1
Buggy, M.2
-
21
-
-
0038638438
-
The effect of vertebral body percentage fill on mechanical behavior during percutaneous vertebroplasty
-
Molloy S, Mathis JM, Belkoff SM. The effect of vertebral body percentage fill on mechanical behavior during percutaneous vertebroplasty. Spine. 2003;28:1549-1554.
-
(2003)
Spine
, vol.28
, pp. 1549-1554
-
-
Molloy, S.1
Mathis, J.M.2
Belkoff, S.M.3
-
22
-
-
0032015176
-
Percutaneous vertebroplasty: State of the art
-
Cotten A, Boutry N, Cortet B, et al. Percutaneous vertebroplasty: State of the art. Radiographics. 1998;18:311-323.
-
(1998)
Radiographics
, vol.18
, pp. 311-323
-
-
Cotten, A.1
Boutry, N.2
Cortet, B.3
-
23
-
-
2542500514
-
Biomechanical comparison of kyphoplasty with different bone cements
-
Tomita S, Molloy S, Jasper L, et al. Biomechanical comparison of kyphoplasty with different bone cements. Spine. 2004;29:1203-1207.
-
(2004)
Spine
, vol.29
, pp. 1203-1207
-
-
Tomita, S.1
Molloy, S.2
Jasper, L.3
-
24
-
-
0027484342
-
Complications associated with the technique of pedicle screw fixation
-
Esses SI, Sachs BL, Dreyzin V. Complications associated with the technique of pedicle screw fixation. Spine. 1993;18:2231-2239.
-
(1993)
Spine
, vol.18
, pp. 2231-2239
-
-
Esses, S.I.1
Sachs, B.L.2
Dreyzin, V.3
-
25
-
-
0025267440
-
Accuracy of pedicular screw placement in vivo
-
Gertzbein SD, Robbins SE. Accuracy of pedicular screw placement in vivo. Spine. 1990;15:11-14.
-
(1990)
Spine
, vol.15
, pp. 11-14
-
-
Gertzbein, S.D.1
Robbins, S.E.2
-
26
-
-
0026445667
-
Anatomic and technical considerations of pedicle screw fixation
-
Weinstein JN, Rydevik BL, Rauschning W. Anatomic and technical considerations of pedicle screw fixation. Clin Orthop. 1992;284:34-36.
-
(1992)
Clin Orthop
, vol.284
, pp. 34-36
-
-
Weinstein, J.N.1
Rydevik, B.L.2
Rauschning, W.3
-
27
-
-
0023790873
-
Spinal pedicle fixation: Reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement
-
Weinstein JN, Spratt KF, Spengler D, et al. Spinal pedicle fixation: Reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine. 1988;13:1012-1018.
-
(1988)
Spine
, vol.13
, pp. 1012-1018
-
-
Weinstein, J.N.1
Spratt, K.F.2
Spengler, D.3
-
28
-
-
0842289226
-
Percutaneous vertebroplasty: Technique and results in 192 procedures
-
Cohen JE, Lylyk P, Ceratto R, et al. Percutaneous vertebroplasty: Technique and results in 192 procedures. Neurol Res. 2004;26:41-49.
-
(2004)
Neurol Res
, vol.26
, pp. 41-49
-
-
Cohen, J.E.1
Lylyk, P.2
Ceratto, R.3
|