-
1
-
-
9144249927
-
A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease
-
Stone G.W., Ellis S.G., Cox D.A., Hermiller J., O'Shaughnessy C., Mann J.T., et al. A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. New Engl J Med 350 (2004) 221-231
-
(2004)
New Engl J Med
, vol.350
, pp. 221-231
-
-
Stone, G.W.1
Ellis, S.G.2
Cox, D.A.3
Hermiller, J.4
O'Shaughnessy, C.5
Mann, J.T.6
-
2
-
-
33745180158
-
Sirolimus-eluting stents at two years: a pooled analysis of SIRIUS, E-SIRIUS, and C-SIRIUS with emphasis on late revascularizations and stent thromboses
-
Schampaert E., Moses J.W., Schofer J., Schluter M., Gershlick A.H., Cohen E.A., et al. Sirolimus-eluting stents at two years: a pooled analysis of SIRIUS, E-SIRIUS, and C-SIRIUS with emphasis on late revascularizations and stent thromboses. Am J Cardiol 98 (2006) 36-41
-
(2006)
Am J Cardiol
, vol.98
, pp. 36-41
-
-
Schampaert, E.1
Moses, J.W.2
Schofer, J.3
Schluter, M.4
Gershlick, A.H.5
Cohen, E.A.6
-
3
-
-
33644877576
-
Persistent remodeling and neointimal suppression 2 years after polymer-based, paclitaxel-eluting stent implantation - insights from serial intravascular ultrasound analysis in the TAXUS II study
-
Aoki J., Colombo A., Dudek D., Banning A.P., Drzewiecki J., Zmudka K., et al. Persistent remodeling and neointimal suppression 2 years after polymer-based, paclitaxel-eluting stent implantation - insights from serial intravascular ultrasound analysis in the TAXUS II study. Circulation 112 (2005) 3876-3883
-
(2005)
Circulation
, vol.112
, pp. 3876-3883
-
-
Aoki, J.1
Colombo, A.2
Dudek, D.3
Banning, A.P.4
Drzewiecki, J.5
Zmudka, K.6
-
4
-
-
20144388922
-
Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation
-
Fujii K., Carlier S.G., Mintz G.S., Yang Y.M., Moussa I., Weisz G., et al. Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation. J Am Coll Cardiol 45 (2005) 995-998
-
(2005)
J Am Coll Cardiol
, vol.45
, pp. 995-998
-
-
Fujii, K.1
Carlier, S.G.2
Mintz, G.S.3
Yang, Y.M.4
Moussa, I.5
Weisz, G.6
-
5
-
-
33845319222
-
Late clinical events after clopidogrel discontinuation may limit the benefit of drug-eluting stents - an observational study of drug-eluting versus bare-metal stents
-
Pfisterer M., Rocca H.P.B.L., Buser P.T., Rickenbacher P., Hunziker P., Mueller C., et al. Late clinical events after clopidogrel discontinuation may limit the benefit of drug-eluting stents - an observational study of drug-eluting versus bare-metal stents. J Am Coll Cardiol 48 (2006) 2584-2591
-
(2006)
J Am Coll Cardiol
, vol.48
, pp. 2584-2591
-
-
Pfisterer, M.1
Rocca, H.P.B.L.2
Buser, P.T.3
Rickenbacher, P.4
Hunziker, P.5
Mueller, C.6
-
7
-
-
10744229988
-
Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious?
-
Virmani R., Guagliumi G., Farb A., Musumeci G., Grieco N., Motta T., et al. Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious?. Circulation 109 (2004) 701-705
-
(2004)
Circulation
, vol.109
, pp. 701-705
-
-
Virmani, R.1
Guagliumi, G.2
Farb, A.3
Musumeci, G.4
Grieco, N.5
Motta, T.6
-
8
-
-
0242489251
-
Synergy of passive coating and targeted drug delivery: the tacrolimus-eluting Janus CarboStent
-
Bartorelli A.L., Trabattoni D., Fabbiocchi F., Montorsi P., de Martini S., Calligaris G., et al. Synergy of passive coating and targeted drug delivery: the tacrolimus-eluting Janus CarboStent. J Interv Cardiol 16 (2003) 499-505
-
(2003)
J Interv Cardiol
, vol.16
, pp. 499-505
-
-
Bartorelli, A.L.1
Trabattoni, D.2
Fabbiocchi, F.3
Montorsi, P.4
de Martini, S.5
Calligaris, G.6
-
9
-
-
0029761378
-
Marked inflammatory sequelae to implantation of biodegradable and nonbiodegradable polymers in porcine coronary arteries
-
van der Giessen W.J., Lincoff A.M., Schwartz R.S., van Beusekom H.M., Serruys P.W., Holmes Jr. D.R., et al. Marked inflammatory sequelae to implantation of biodegradable and nonbiodegradable polymers in porcine coronary arteries. Circulation 94 (1996) 1690-1697
-
(1996)
Circulation
, vol.94
, pp. 1690-1697
-
-
van der Giessen, W.J.1
Lincoff, A.M.2
Schwartz, R.S.3
van Beusekom, H.M.4
Serruys, P.W.5
Holmes Jr., D.R.6
-
10
-
-
0037137302
-
Mechanism of late in-stent restenosis after implantation of a paclitaxel derivate-eluting polymer stent system in humans
-
Virmani R., Liistro F., Stankovic G., Di Mario C., Montorfano M., Farb A., et al. Mechanism of late in-stent restenosis after implantation of a paclitaxel derivate-eluting polymer stent system in humans. Circulation 106 (2002) 2649-2651
-
(2002)
Circulation
, vol.106
, pp. 2649-2651
-
-
Virmani, R.1
Liistro, F.2
Stankovic, G.3
Di Mario, C.4
Montorfano, M.5
Farb, A.6
-
11
-
-
4644279430
-
High-dose 7-hexanoyltaxol-eluting stent with polymer sleeves for coronary revascularization - one-year results from the SCORE randomized trial
-
Grube E., Lansky A., Hauptmann K.E., Di Mario C., Di Sciascio G., Colombo A., et al. High-dose 7-hexanoyltaxol-eluting stent with polymer sleeves for coronary revascularization - one-year results from the SCORE randomized trial. J Am Coll Cardiol 44 (2004) 1368-1372
-
(2004)
J Am Coll Cardiol
, vol.44
, pp. 1368-1372
-
-
Grube, E.1
Lansky, A.2
Hauptmann, K.E.3
Di Mario, C.4
Di Sciascio, G.5
Colombo, A.6
-
12
-
-
29344432871
-
Hypersensitivity cases associated with drug-eluting coronary stents - a review of available cases from the research on adverse drug events and reports (RADAR) project
-
Nebeker J.R., Virmani R., Bennett C.L., Hoffman J.M., Samore M.H., Alvarez J., et al. Hypersensitivity cases associated with drug-eluting coronary stents - a review of available cases from the research on adverse drug events and reports (RADAR) project. J Am Coll Cardiol 47 (2006) 175-181
-
(2006)
J Am Coll Cardiol
, vol.47
, pp. 175-181
-
-
Nebeker, J.R.1
Virmani, R.2
Bennett, C.L.3
Hoffman, J.M.4
Samore, M.H.5
Alvarez, J.6
-
13
-
-
34250835092
-
Vascular responses to drug eluting stents - importance of delayed healing
-
Finn A.V., Nakazawa G., Joner M., Kolodgie F.D., Mont E.K., Gold H.K., et al. Vascular responses to drug eluting stents - importance of delayed healing. Arterioscl Throm Vas 27 (2007) 1500-1510
-
(2007)
Arterioscl Throm Vas
, vol.27
, pp. 1500-1510
-
-
Finn, A.V.1
Nakazawa, G.2
Joner, M.3
Kolodgie, F.D.4
Mont, E.K.5
Gold, H.K.6
-
14
-
-
33745233024
-
Pathology of drug-eluting stents in humans - delayed healing and late thrombotic risk
-
Joner M., Finn A.V., Farb A., Mont E.K., Kolodgie F.D., Ladich E., et al. Pathology of drug-eluting stents in humans - delayed healing and late thrombotic risk. J Am Coll Cardiol 48 (2006) 193-202
-
(2006)
J Am Coll Cardiol
, vol.48
, pp. 193-202
-
-
Joner, M.1
Finn, A.V.2
Farb, A.3
Mont, E.K.4
Kolodgie, F.D.5
Ladich, E.6
-
15
-
-
33847259689
-
Drug-eluting stent and coronary thrombosis - biological mechanisms and clinical implications
-
Luscher T.F., Steffel J., Eberli F.R., Joner M., Nakazawa G., Tanner F.C., et al. Drug-eluting stent and coronary thrombosis - biological mechanisms and clinical implications. Circulation 115 (2007) 1051-1058
-
(2007)
Circulation
, vol.115
, pp. 1051-1058
-
-
Luscher, T.F.1
Steffel, J.2
Eberli, F.R.3
Joner, M.4
Nakazawa, G.5
Tanner, F.C.6
-
16
-
-
0026518970
-
Intense granulomatous inflammatory lesions associated with absorbable internal-fixation devices made of polyglycolide in ankle fractures
-
Bostman O.M. Intense granulomatous inflammatory lesions associated with absorbable internal-fixation devices made of polyglycolide in ankle fractures. Clin Orthop Relat Res 278 (1992) 193-199
-
(1992)
Clin Orthop Relat Res
, vol.278
, pp. 193-199
-
-
Bostman, O.M.1
-
17
-
-
0028450615
-
Six bioabsorbable polymers - in vitro acute toxicity of accumulated degradation products
-
Taylor M.S., Daniels A.U., Andriano K.P., and Heller J. Six bioabsorbable polymers - in vitro acute toxicity of accumulated degradation products. J Appl Biomaterials 5 (1994) 151-157
-
(1994)
J Appl Biomaterials
, vol.5
, pp. 151-157
-
-
Taylor, M.S.1
Daniels, A.U.2
Andriano, K.P.3
Heller, J.4
-
18
-
-
0028223999
-
Local delivery of dexamethasone for prevention of neointimal proliferation in a rat model of balloon angioplasty
-
Villa A.E., Guzman L.A., Chen W., Golomb G., Levy R.J., and Topol E.J. Local delivery of dexamethasone for prevention of neointimal proliferation in a rat model of balloon angioplasty. J Clin Invest 93 (1994) 1243-1249
-
(1994)
J Clin Invest
, vol.93
, pp. 1243-1249
-
-
Villa, A.E.1
Guzman, L.A.2
Chen, W.3
Golomb, G.4
Levy, R.J.5
Topol, E.J.6
-
19
-
-
1942436763
-
Long term in vivo biostability of poly(dimethylsiloxane)/poly(hexamethylene oxide) mixed macrodiol-based polyurethane elastomers
-
Simmons A., Hyvarinen J., Odell R.A., Martin D.J., Gunatillake P.A., Noble K.R., et al. Long term in vivo biostability of poly(dimethylsiloxane)/poly(hexamethylene oxide) mixed macrodiol-based polyurethane elastomers. Biomaterials 25 (2004) 4887-4900
-
(2004)
Biomaterials
, vol.25
, pp. 4887-4900
-
-
Simmons, A.1
Hyvarinen, J.2
Odell, R.A.3
Martin, D.J.4
Gunatillake, P.A.5
Noble, K.R.6
-
20
-
-
26844515262
-
Reduced thrombogenicity of nitinol stents - in vitro evaluation of different surface modifications and coatings
-
Tepe G., Schmehl J., Wendel H.P., Schaffner S., Heller S., Gianotti M., et al. Reduced thrombogenicity of nitinol stents - in vitro evaluation of different surface modifications and coatings. Biomaterials 27 (2006) 643-650
-
(2006)
Biomaterials
, vol.27
, pp. 643-650
-
-
Tepe, G.1
Schmehl, J.2
Wendel, H.P.3
Schaffner, S.4
Heller, S.5
Gianotti, M.6
-
21
-
-
0032144796
-
Biocompatibility of poly(ether urethane urea) containing dehydroepiandrosterone
-
Collier T., Tan J., Shive M., Hasan S., Hiltner A., and Anderson J. Biocompatibility of poly(ether urethane urea) containing dehydroepiandrosterone. J Biomed Mater Res 41 (1998) 192-201
-
(1998)
J Biomed Mater Res
, vol.41
, pp. 192-201
-
-
Collier, T.1
Tan, J.2
Shive, M.3
Hasan, S.4
Hiltner, A.5
Anderson, J.6
-
22
-
-
0026170185
-
Effect of some additives on the biostability of a poly(ether urethane) elastomer
-
Wu Y., Zhao Q., Anderson J.M., Hiltner A., Lodoen G.A., and Payet C.R. Effect of some additives on the biostability of a poly(ether urethane) elastomer. J Biomed Mater Res 25 (1991) 725-739
-
(1991)
J Biomed Mater Res
, vol.25
, pp. 725-739
-
-
Wu, Y.1
Zhao, Q.2
Anderson, J.M.3
Hiltner, A.4
Lodoen, G.A.5
Payet, C.R.6
-
23
-
-
0031106747
-
Comparison of two antioxidants for poly(ether urethane urea) in an accelerated in vitro biodegradation system
-
Schubert M.A., Wiggins M.J., Anderson J.M., and Hiltner A. Comparison of two antioxidants for poly(ether urethane urea) in an accelerated in vitro biodegradation system. J Biomed Mater Res 34 (1997) 493-505
-
(1997)
J Biomed Mater Res
, vol.34
, pp. 493-505
-
-
Schubert, M.A.1
Wiggins, M.J.2
Anderson, J.M.3
Hiltner, A.4
-
24
-
-
0027571735
-
Protein adsorption to poly(ether urethane ureas) modified with acrylate and methacrylate polymer and copolymer additives
-
Brunstedt M.R., Ziats N.P., Robertson S.P., Hiltner A., Anderson J.M., Lodoen G.A., et al. Protein adsorption to poly(ether urethane ureas) modified with acrylate and methacrylate polymer and copolymer additives. J Biomed Mater Res 27 (1993) 367-377
-
(1993)
J Biomed Mater Res
, vol.27
, pp. 367-377
-
-
Brunstedt, M.R.1
Ziats, N.P.2
Robertson, S.P.3
Hiltner, A.4
Anderson, J.M.5
Lodoen, G.A.6
-
25
-
-
0034851444
-
PDMS-based polyurethanes with MPEG grafts: mechanical properties, bacterial repellency, and release behavior of rifampicin
-
Park J.H., Lee K.B., Kwon I.C., and Bae Y.H. PDMS-based polyurethanes with MPEG grafts: mechanical properties, bacterial repellency, and release behavior of rifampicin. J Biomater Sci 12 (2001) 629-645
-
(2001)
J Biomater Sci
, vol.12
, pp. 629-645
-
-
Park, J.H.1
Lee, K.B.2
Kwon, I.C.3
Bae, Y.H.4
-
26
-
-
0034057488
-
Polydimethylsiloxane/polyether-mixed macrodiol-based polyurethane elastomers: biostability
-
Martin D.J., Poole-Warren L.A., Gunatillake P.A., McCarthy S.J., Meijs G.F., and Schindhelm K. Polydimethylsiloxane/polyether-mixed macrodiol-based polyurethane elastomers: biostability. Biomaterials 21 (2000) 1021-1029
-
(2000)
Biomaterials
, vol.21
, pp. 1021-1029
-
-
Martin, D.J.1
Poole-Warren, L.A.2
Gunatillake, P.A.3
McCarthy, S.J.4
Meijs, G.F.5
Schindhelm, K.6
-
28
-
-
0031281407
-
In-vivo degradation of polyurethanes: transmission-FTIR microscopic characterization of polyurethanes sectioned by cryomicrotomy
-
McCarthy S.J., Meijs G.F., Mitchell N., Gunatillake P.A., Heath G., Brandwood A., et al. In-vivo degradation of polyurethanes: transmission-FTIR microscopic characterization of polyurethanes sectioned by cryomicrotomy. Biomaterials 18 (1997) 1387-1409
-
(1997)
Biomaterials
, vol.18
, pp. 1387-1409
-
-
McCarthy, S.J.1
Meijs, G.F.2
Mitchell, N.3
Gunatillake, P.A.4
Heath, G.5
Brandwood, A.6
-
29
-
-
42749090762
-
-
SDBS library of IR spectra. Japan: AIST; 4 January 2007.
-
SDBS library of IR spectra. Japan: AIST; 4 January 2007.
-
-
-
-
30
-
-
17544384479
-
Recent advances in the analysis of steroid hormones and related drugs
-
Gorog S. Recent advances in the analysis of steroid hormones and related drugs. Anal Sci 20 (2004) 767-782
-
(2004)
Anal Sci
, vol.20
, pp. 767-782
-
-
Gorog, S.1
-
31
-
-
5644264701
-
Studies on the stability of corticosteroids
-
Bundgaard H., and Hansen J. Studies on the stability of corticosteroids. Arch Pharm Chem Sci Ed 8 (1980) 187-206
-
(1980)
Arch Pharm Chem Sci Ed
, vol.8
, pp. 187-206
-
-
Bundgaard, H.1
Hansen, J.2
-
32
-
-
0033567864
-
In vitro modulation of macrophage phenotype and inhibition of polymer degradation by dexamethasone in a human macrophage/Fe/stress system
-
Casas J., Zhao Q., Donovan M., Schroeder P., Stokes K., and Untereker D. In vitro modulation of macrophage phenotype and inhibition of polymer degradation by dexamethasone in a human macrophage/Fe/stress system. J Biomed Mater Res 46 (1999) 475-484
-
(1999)
J Biomed Mater Res
, vol.46
, pp. 475-484
-
-
Casas, J.1
Zhao, Q.2
Donovan, M.3
Schroeder, P.4
Stokes, K.5
Untereker, D.6
-
33
-
-
0033015171
-
Glucocorticoids, oxysterols, and cAMP with glucocorticoids each cause apoptosis of CEM cells and suppress c-myc
-
Thompson E.B., Medh R.D., Zhou F., Ayala-Torres S., Ansari N., Zhang W., et al. Glucocorticoids, oxysterols, and cAMP with glucocorticoids each cause apoptosis of CEM cells and suppress c-myc. J Ster Biochem Mol Biol 69 (1999) 453-461
-
(1999)
J Ster Biochem Mol Biol
, vol.69
, pp. 453-461
-
-
Thompson, E.B.1
Medh, R.D.2
Zhou, F.3
Ayala-Torres, S.4
Ansari, N.5
Zhang, W.6
-
34
-
-
0036721023
-
Glucocorticoids and rituximab in vitro: synergistic direct antiproliferative and apoptotic effects
-
Rose A.L., Smith B.E., and Maloney D.G. Glucocorticoids and rituximab in vitro: synergistic direct antiproliferative and apoptotic effects. Blood 100 (2002) 1765-1773
-
(2002)
Blood
, vol.100
, pp. 1765-1773
-
-
Rose, A.L.1
Smith, B.E.2
Maloney, D.G.3
-
35
-
-
10744221130
-
Study of antirestenosis with the BiodivYsio dexamethasone-eluting stent (STRIDE): a first-in-human multicenter pilot trial
-
Liu X., Huang Y., Hanet C., Vandormael M., Legrand V., Dens J., et al. Study of antirestenosis with the BiodivYsio dexamethasone-eluting stent (STRIDE): a first-in-human multicenter pilot trial. Catheter Cardiovasc Interv 60 (2003) 172-179
-
(2003)
Catheter Cardiovasc Interv
, vol.60
, pp. 172-179
-
-
Liu, X.1
Huang, Y.2
Hanet, C.3
Vandormael, M.4
Legrand, V.5
Dens, J.6
-
36
-
-
0030935847
-
Sustained local delivery of dexamethasone by a novel intravascular eluting stent to prevent restenosis in the porcine coronary injury model
-
Lincoff A.M., Furst J.G., Ellis S.G., Tuch R.J., and Topol E.J. Sustained local delivery of dexamethasone by a novel intravascular eluting stent to prevent restenosis in the porcine coronary injury model. J Am Coll Cardiol 29 (1997) 808-816
-
(1997)
J Am Coll Cardiol
, vol.29
, pp. 808-816
-
-
Lincoff, A.M.1
Furst, J.G.2
Ellis, S.G.3
Tuch, R.J.4
Topol, E.J.5
-
37
-
-
0036274835
-
In vivo evaluation of a dexamethasone/PLGA microsphere system designed to suppress the inflammatory tissue response to implantable medical devices
-
Hickey T., Kreutzer D., Burgess D.J., and Moussy F. In vivo evaluation of a dexamethasone/PLGA microsphere system designed to suppress the inflammatory tissue response to implantable medical devices. J Biomed Mater Res 61 (2002) 180-187
-
(2002)
J Biomed Mater Res
, vol.61
, pp. 180-187
-
-
Hickey, T.1
Kreutzer, D.2
Burgess, D.J.3
Moussy, F.4
-
38
-
-
0036962734
-
In vivo biocompatibility of gelatin-based hydrogels and interpenetrating networks
-
Stevens K.R., Einerson N.J., Burmania J.A., and Kao W.J. In vivo biocompatibility of gelatin-based hydrogels and interpenetrating networks. J Biomater Sci 13 (2002) 1353-1366
-
(2002)
J Biomater Sci
, vol.13
, pp. 1353-1366
-
-
Stevens, K.R.1
Einerson, N.J.2
Burmania, J.A.3
Kao, W.J.4
|