메뉴 건너뛰기




Volumn 41, Issue 9, 2008, Pages

Removal of model proteins by means of low-pressure inductively coupled plasma discharge

Author keywords

[No Author keywords available]

Indexed keywords

BIOMEDICAL EQUIPMENT; GLASS; INDUCTIVELY COUPLED PLASMA; POLYSTYRENES;

EID: 42549158363     PISSN: 00223727     EISSN: 13616463     Source Type: Journal    
DOI: 10.1088/0022-3727/41/9/095201     Document Type: Article
Times cited : (66)

References (36)
  • 3
    • 0035845749 scopus 로고    scopus 로고
    • Low-temperature sterilization using gas plasmas: A review of the experiments and an analysis of the inactivation mechanisms
    • Moisan M, Barbeau J, Moreau S, Pelletier J, Tabrizian M and Yahia L'H 2001 Low-temperature sterilization using gas plasmas: a review of the experiments and an analysis of the inactivation mechanisms Int. J. Pharmaceutics 226 1-21
    • (2001) Int. J. Pharmaceutics , vol.226 , Issue.1-2 , pp. 1-21
    • Moisan, M.1    Barbeau, J.2    Moreau, S.3    Pelletier, J.4    Tabrizian, M.5    L'H, Y.6
  • 6
    • 33746883588 scopus 로고    scopus 로고
    • Bacterial spore inactivation by atmospheric-pressure plasmas in the presence or absence of UV photons as obtained with the same gas mixture
    • Boudam M K, Moisan M, Saoudi B, Popovici C, Gherardi N and Massines F 2006 Bacterial spore inactivation by atmospheric-pressure plasmas in the presence or absence of UV photons as obtained with the same gas mixture J. Phys. D: Appl. Phys. 39 3494-507
    • (2006) J. Phys. D: Appl. Phys. , vol.39 , Issue.16 , pp. 3494-3507
    • Boudam, M.K.1    Moisan, M.2    Saoudi, B.3    Popovici, C.4    Gherardi, N.5    Massines, F.6
  • 7
    • 34748891368 scopus 로고    scopus 로고
    • Identification of the most efficient VUV/UV radiation for plasma based inactivation of Bacillus atrophaeus spores
    • Halfmann H, Denis B, Bibinov N, Wunderlich J and Awakowicz P 2007 Identification of the most efficient VUV/UV radiation for plasma based inactivation of Bacillus atrophaeus spores J. Phys. D: Appl. Phys. 40 5907-11
    • (2007) J. Phys. D: Appl. Phys. , vol.40 , Issue.19 , pp. 5907-5911
    • Halfmann, H.1    Denis, B.2    Bibinov, N.3    Wunderlich, J.4    Awakowicz, P.5
  • 8
    • 20844463749 scopus 로고    scopus 로고
    • Effects of oxygen radicals in low-pressure surface-wave plasma on sterilization
    • Nagatsu M, Terashita F, Nonaka H, Xu L, Nagata T and Koide Y 2005 Effects of oxygen radicals in low-pressure surface-wave plasma on sterilization Appl. Phys. Lett. 86 211502
    • (2005) Appl. Phys. Lett. , vol.86 , Issue.21 , pp. 211502
    • Nagatsu, M.1    Terashita, F.2    Nonaka, H.3    Xu, L.4    Nagata, T.5    Koide, Y.6
  • 9
    • 0034108982 scopus 로고    scopus 로고
    • Effect of gas composition on spore mortality and etching during low-pressure plasma sterilization
    • Lerouge S, Wertheimer M R, Marchand R and Yahia L'H 2000 Effect of gas composition on spore mortality and etching during low-pressure plasma sterilization J. Biomed. Mater. Res. 51 128-35
    • (2000) J. Biomed. Mater. Res. , vol.51 , Issue.1 , pp. 128-135
    • Lerouge, S.1    Wertheimer, M.R.2    Marchand, R.3    L'H, Y.4
  • 11
    • 33745534425 scopus 로고    scopus 로고
    • 2 discharge at reduced pressure: Study of destruction mechanism of bacteria and hydrodynamics of the afterglow flow
    • 2 discharge at reduced pressure: study of destruction mechanism of bacteria and hydrodynamics of the afterglow flow Eur. Phys. J. Appl. Phys. 34 143-6
    • (2006) Eur. Phys. J. Appl. Phys. , vol.34 , Issue.2 , pp. 143-146
    • Cousty, S.1    Villeger, S.2    Sarette, J.P.3    Ricard, A.4    Sixou, M.5
  • 12
    • 33748440080 scopus 로고    scopus 로고
    • Decontamination of surfaces by low pressure plasma discharges
    • Rossi F, Kylin O and Hasiwa M 2006 Decontamination of surfaces by low pressure plasma discharges Plasma Process. Polym. 3 431-42
    • (2006) Plasma Process. Polym. , vol.3 , Issue.6-7 , pp. 431-442
    • Rossi, F.1    Kylin, O.2    Hasiwa, M.3
  • 13
    • 42549130643 scopus 로고    scopus 로고
    • Mechanisms of sterilization and decontamination of surfaces by low pressure plasma
    • Rossi F, Kylin O and Hasiwa M 2007 Mechanisms of sterilization and decontamination of surfaces by low pressure plasma Advanced Plasma Technology ed R d'Agostino et al (New York: Wiley)
    • (2007) Advanced Plasma Technology
    • Rossi, F.1    Kylin, O.2    Hasiwa, M.3
  • 15
    • 33947358211 scopus 로고    scopus 로고
    • Effect of low-pressure microwave discharges on pyrogen bioactivity
    • Kylin O, Hasiwa M and Rossi F 2006 Effect of low-pressure microwave discharges on pyrogen bioactivity IEEE Trans. Plasma Sci. 34 2606-10
    • (2006) IEEE Trans. Plasma Sci. , vol.34 , Issue.6 , pp. 2606-2610
    • Kylin, O.1    Hasiwa, M.2    Rossi, F.3
  • 18
    • 0033382236 scopus 로고    scopus 로고
    • Inactivation of prions by physical and chemical means
    • Taylor D M 1999 Inactivation of prions by physical and chemical means J. Hosp. Infec. 43 S69-76
    • (1999) J. Hosp. Infec. , vol.43
    • Taylor, D.M.1
  • 19
    • 34248642838 scopus 로고    scopus 로고
    • Comparative study of surgical instruments from sterile-service departments for presence of residual gram-negative endotoxin and proteinaceous deposits
    • Lipscomb I P, Sihota A K and Keevil C W 2006 Comparative study of surgical instruments from sterile-service departments for presence of residual gram-negative endotoxin and proteinaceous deposits J. Clin. Microbiol. 44 3728-33
    • (2006) J. Clin. Microbiol. , vol.44 , Issue.10 , pp. 3728-3733
    • Lipscomb, I.P.1    Sihota, A.K.2    Keevil, C.W.3
  • 22
    • 33746864132 scopus 로고    scopus 로고
    • Validation of cold plasma treatment for protein inactivation: A surface plasmon resonance-based biosensor study
    • Bernard C, Leduc A, Bardeau J, Saoudi B, Yahia L'Y and De Crescenzo G 2006 Validation of cold plasma treatment for protein inactivation: a surface plasmon resonance-based biosensor study J. Phys. D: Appl. Phys. 39 3470-8
    • (2006) J. Phys. D: Appl. Phys. , vol.39 , Issue.16 , pp. 3470-3478
    • Bernard, C.1    Leduc, A.2    Bardeau, J.3    Saoudi, B.4    L'Y, Y.5    De Crescenzo, G.6
  • 23
    • 33846060754 scopus 로고    scopus 로고
    • Protein destruction by atmospheric pressure glow discharge
    • Deng X T, Shi J J, Chen H L and Kong M G 2007 Protein destruction by atmospheric pressure glow discharge Appl. Phys. Lett. 90 013903
    • (2007) Appl. Phys. Lett. , vol.90 , Issue.1 , pp. 013903
    • Deng, X.T.1    Shi, J.J.2    Chen, H.L.3    Kong, M.G.4
  • 24
    • 34247186912 scopus 로고    scopus 로고
    • Protein destruction by a helium atmospheric pressure glow discharge: Capability and mechanisms
    • Deng X T, Shi J J and Kong M G 2007 Protein destruction by a helium atmospheric pressure glow discharge: capability and mechanisms J. Appl. Phys. 101 074701
    • (2007) J. Appl. Phys. , vol.101 , Issue.7 , pp. 074701
    • Deng, X.T.1    Shi, J.J.2    Kong, M.G.3
  • 25
    • 77954346313 scopus 로고    scopus 로고
    • Protein film removal by means of low-pressure microwave plasma-an imaging ellipsometry study
    • Kylin O, Rauscher H, Sirghi L and Rossi F 2008 Protein film removal by means of low-pressure microwave plasma-an imaging ellipsometry study J. Phys.: Conf. Ser. at press
    • (2008) J. Phys.: Conf. Ser.
    • Kylin, O.1    Rauscher, H.2    Sirghi, L.3    Rossi, F.4
  • 27
    • 33747869916 scopus 로고    scopus 로고
    • Surgical instrument decontamination: Efficacy of introducing an argon: Oxygen RF gas-plasma cleaning step as part of the cleaning cycle for stainless steel instruments
    • Baxter H C, Campbell G A, Richardson P R, Jones A C, Whittle I R, Casey M, Whittaker A G and Baxter R L 2006 Surgical instrument decontamination: efficacy of introducing an argon: oxygen RF gas-plasma cleaning step as part of the cleaning cycle for stainless steel instruments IEEE Trans. Plasma Sci. 34 1337-44
    • (2006) IEEE Trans. Plasma Sci. , vol.34 , Issue.4 , pp. 1337-1344
    • Baxter, H.C.1    Campbell, G.A.2    Richardson, P.R.3    Jones, A.C.4    Whittle, I.R.5    Casey, M.6    Whittaker, A.G.7    Baxter, R.L.8
  • 29
    • 33845658217 scopus 로고    scopus 로고
    • Effect of drying time, ambient temperature and pre-soaks on prion-infected tissue contamination level on surgical stainless steel: Concerns over prolonged transportation of instruments from theatre to central sterile service departments
    • Lipscomb I P, Pinchin H, Collin R and Keevil C W 2007 Effect of drying time, ambient temperature and pre-soaks on prion-infected tissue contamination level on surgical stainless steel: concerns over prolonged transportation of instruments from theatre to central sterile service departments J. Hosp. Infec. 65 72-7
    • (2007) J. Hosp. Infec. , vol.65 , Issue.1 , pp. 72-77
    • Lipscomb, I.P.1    Pinchin, H.2    Collin, R.3    Keevil, C.W.4
  • 30
    • 34547348962 scopus 로고    scopus 로고
    • A double inductively coupled plasma for sterilization of medical devices
    • Halfmann H, Bibinov N, Wunderlich J and Awakowicz P 2007 A double inductively coupled plasma for sterilization of medical devices J. Phys. D: Appl. Phys. 40 4145-54
    • (2007) J. Phys. D: Appl. Phys. , vol.40 , Issue.14 , pp. 4145-4154
    • Halfmann, H.1    Bibinov, N.2    Wunderlich, J.3    Awakowicz, P.4
  • 31
  • 33
    • 84908202398 scopus 로고
    • Plasma etching and modification of organic polymers
    • Egitto F D 1990 Plasma etching and modification of organic polymers Pure Appl. Chem. 62 1699-708
    • (1990) Pure Appl. Chem. , vol.62 , Issue.9 , pp. 1699-1708
    • Egitto, F.D.1
  • 35
    • 38349054918 scopus 로고    scopus 로고
    • Plasma sterilisation within long and narrow bore dielectric tubes contaminated with stacked bacterial spores
    • Pollak J, Moisan M, Kéroack D, Séguin J and Barbeau J 2008 Plasma sterilisation within long and narrow bore dielectric tubes contaminated with stacked bacterial spores Plasma Process. Polym. 5 14-25
    • (2008) Plasma Process. Polym. , vol.5 , Issue.1 , pp. 14-25
    • Pollak, J.1    Moisan, M.2    Kéroack, D.3    Séguin, J.4    Barbeau, J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.