메뉴 건너뛰기




Volumn 84, Issue 24, 2000, Pages 5552-5555

Tensile loading of ropes of single wall carbon nanotubes and their mechanical properties

Author keywords

[No Author keywords available]

Indexed keywords

ATOMIC FORCE MICROSCOPY; CARBON; ELASTIC MODULI; LOADS (FORCES); MATHEMATICAL MODELS; SCANNING ELECTRON MICROSCOPY; STRESSES; TENSILE PROPERTIES; TRANSMISSION ELECTRON MICROSCOPY;

EID: 4244187838     PISSN: 00319007     EISSN: None     Source Type: Journal    
DOI: 10.1103/PhysRevLett.84.5552     Document Type: Article
Times cited : (2516)

References (28)
  • 2
    • 0342705993 scopus 로고
    • London
    • D.S. Bethune et al., Nature (London) 363, 605 (1993).
    • (1993) Nature , vol.363 , pp. 605
    • Bethune, D.S.1
  • 3
    • 0007178040 scopus 로고    scopus 로고
    • London
    • S. J. Tans et al., Nature (London) 386, 474 (1997).
    • (1997) Nature , vol.386 , pp. 474
    • Tans, S.J.1
  • 5
    • 0031912473 scopus 로고    scopus 로고
    • London
    • T. W. Odom et al., Nature (London) 391, 62 (1998).
    • (1998) Nature , vol.391 , pp. 62
    • Odom, T.W.1
  • 18
    • 0034723247 scopus 로고    scopus 로고
    • M-F. Yu et al., Science 287, 637 (2000).
    • (2000) Science , vol.287 , pp. 637
    • Yu, M.-F.1
  • 20
    • 0342339342 scopus 로고    scopus 로고
    • Part Number: BIMP15/6/0.6-PX5-N, American Piezo Ceramics, Inc.
    • Part Number: BIMP15/6/0.6-PX5-N, American Piezo Ceramics, Inc.
  • 21
    • 0343208950 scopus 로고    scopus 로고
    • Noncontact SC12 silicon cantilever, Silicon-Molecular Devices and Tools Ltd. The force constant of the cantilever is calibrated using its dimensions measured in SEM. In addition, the force constants of the 15 cantilevers used here were independently measured using calibrated AFM cantilevers from Thermomicroscopes. The average measured value differed by 7% from the average value calculated from the SEM determined geometry
    • Noncontact SC12 silicon cantilever, Silicon-Molecular Devices and Tools Ltd. The force constant of the cantilever is calibrated using its dimensions measured in SEM. In addition, the force constants of the 15 cantilevers used here were independently measured using calibrated AFM cantilevers from Thermomicroscopes. The average measured value differed by 7% from the average value calculated from the SEM determined geometry.
  • 23
    • 0027909801 scopus 로고
    • London
    • R. S. Ruoff et al., Nature (London) 364, 514 (1993).
    • (1993) Nature , vol.364 , pp. 514
    • Ruoff, R.S.1
  • 25
    • 6444244907 scopus 로고    scopus 로고
    • A. Thess et al., Science 273, 483 (1996).
    • (1996) Science , vol.273 , pp. 483
    • Thess, A.1
  • 26
    • 0342774318 scopus 로고    scopus 로고
    • note
    • c even.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.