-
1
-
-
0034655412
-
Complications of pedicle screw fixation in reconstructive surgery of the cervical spine
-
8
-
Abumi K, Shono Y, Ito M, Taneichi H, Kotani Y, Kaneda K (2000) Complications of pedicle screw fixation in reconstructive surgery of the cervical spine. Spine 25(8):962-969
-
(2000)
Spine
, vol.25
, pp. 962-969
-
-
Abumi, K.1
Shono, Y.2
Ito, M.3
Taneichi, H.4
Kotani, Y.5
Kaneda, K.6
-
2
-
-
15044363145
-
Cervical spine injuries associated with lateral mass and facet joint fractures: New classification and surgical treatment with pedicle fixation
-
Kotani Y, Abumi K, Ito M, Minami A (2005) Cervical spine injuries associated with lateral mass and facet joint fractures: new classification and surgical treatment with pedicle fixation. Eur Spine J 14:69-77
-
(2005)
Eur Spine J
, vol.14
, pp. 69-77
-
-
Kotani, Y.1
Abumi, K.2
Ito, M.3
Minami, A.4
-
3
-
-
33645499877
-
Percutaneous placement of posterior cervical screws using three-dimensional fluoroscopy
-
Holly LT, Foley KT (2006) Percutaneous placement of posterior cervical screws using three-dimensional fluoroscopy. Spine 31:536-540
-
(2006)
Spine
, vol.31
, pp. 536-540
-
-
Holly, L.T.1
Foley, K.T.2
-
4
-
-
0027999435
-
Transpedicular screw fixation of articular mass fracture-separation: Results of an anatomical study and operative technique
-
Jeanneret B, Gebhard JS, Magerl F (1994) Transpedicular screw fixation of articular mass fracture-separation: results of an anatomical study and operative technique. Spine 19:2529-2539
-
(1994)
Spine
, vol.19
, pp. 2529-2539
-
-
Jeanneret, B.1
Gebhard, J.S.2
Magerl, F.3
-
5
-
-
0034466242
-
Cervical pedicle screw insertion: Assessment of safety and accuracy with computer-assisted image guidance
-
Kamimura M, Ebara S, Itoh H, Tateiwa Y, Kinoshita T, Takaoka K (2003) Cervical pedicle screw insertion: assessment of safety and accuracy with computer-assisted image guidance. J Spinal Disord 13:218-224
-
(2003)
J Spinal Disord
, vol.13
, pp. 218-224
-
-
Kamimura, M.1
Ebara, S.2
Itoh, H.3
Tateiwa, Y.4
Kinoshita, T.5
Takaoka, K.6
-
6
-
-
0035890086
-
Accuracy of cervical pedicle screw placement using the funnel technique
-
Karaikovic EE, Yingsakmongkol W, Gaines RW (2001) Accuracy of cervical pedicle screw placement using the funnel technique. Spine 26:2456-2462
-
(2001)
Spine
, vol.26
, pp. 2456-2462
-
-
Karaikovic, E.E.1
Yingsakmongkol, W.2
Gaines, R.W.3
-
7
-
-
0034667343
-
Cervical pedicle screws: Comparative accuracy of two insertion techniques
-
Ludwig SC, Kowalski JM, Edwards CC 2nd, Heller JG (2000) Cervical pedicle screws: comparative accuracy of two insertion techniques. Spine 25:2675-2681
-
(2000)
Spine
, vol.25
, pp. 2675-2681
-
-
Ludwig, S.C.1
Kowalski, J.M.2
Edwards II, C.C.3
Heller, J.G.4
-
8
-
-
0033925472
-
Placement of pedicle screws in the human cadaveric cervical spine: Comparative accuracy of three techniques
-
Ludwig SC, Kramer DL, Balderston RA, Vaccaro AR, Foley KF, Albert TJ (2000) Placement of pedicle screws in the human cadaveric cervical spine: comparative accuracy of three techniques. Spine 25:1655-1667
-
(2000)
Spine
, vol.25
, pp. 1655-1667
-
-
Ludwig, S.C.1
Kramer, D.L.2
Balderston, R.A.3
Vaccaro, A.R.4
Foley, K.F.5
Albert, T.J.6
-
9
-
-
18644366161
-
Design of cervical pedicle locator and three-dimensional location of cervical pedicle
-
Mao GP, Zhao JN, Wang YR, Li JS, chen YX, Wu SJ, Bao NR (2005) Design of cervical pedicle locator and three-dimensional location of cervical pedicle. Spine 30:1045-1050
-
(2005)
Spine
, vol.30
, pp. 1045-1050
-
-
Mao, G.P.1
Zhao, J.N.2
Wang, Y.R.3
Li, J.S.4
Chen, Y.X.5
Wu, S.J.6
Bao, N.R.7
-
10
-
-
0029848159
-
Anatomic consideration of transpedicular screw placement in the cervical spine: An analysis of two approaches
-
Miller RM, Ebraheim NA, Xu R, Yeasting RA (1996) Anatomic consideration of transpedicular screw placement in the cervical spine: an analysis of two approaches. Spine 21:2317-2322
-
(1996)
Spine
, vol.21
, pp. 2317-2322
-
-
Miller, R.M.1
Ebraheim, N.A.2
Xu, R.3
Yeasting, R.A.4
-
11
-
-
33846421082
-
Cervical pedicle screw placement: Feasibility and accuracy of two new insertion techniques based on morphometric data
-
Reinhold M, Magerl F, Rieger M, Blauth M (2006) Cervical pedicle screw placement: feasibility and accuracy of two new insertion techniques based on morphometric data. Eur Spine J 16:47-56
-
(2006)
Eur Spine J
, vol.16
, pp. 47-56
-
-
Reinhold, M.1
Magerl, F.2
Rieger, M.3
Blauth, M.4
-
12
-
-
0036527504
-
Computer-assisted surgery in dorsal instrumentation of the cervical spine: An in vitro study
-
Richter M, Amiot LP, Puhl W (2002) Computer-assisted surgery in dorsal instrumentation of the cervical spine: an in vitro study. Orthopäde 31:372-377
-
(2002)
Orthopäde
, vol.31
, pp. 372-377
-
-
Richter, M.1
Amiot, L.P.2
Puhl, W.3
-
13
-
-
42149093066
-
-
Boston: Cervical Spine Research Society-A, Poster
-
Roh JS, Teng AL, Rice JA, Huang RC, Davis JA (2004) Accurate cervical pedicle screw placement using laser-guided fluoroscopy: the 'perfect pedicle' technique. 32nd annual meeting. Boston: Cervical Spine Research Society-A, Poster 16:69
-
(2004)
Accurate Cervical Pedicle Screw Placement Using Laser-guided Fluoroscopy: The 'Perfect Pedicle' Technique. 32nd Annual Meeting
, vol.16
, pp. 69
-
-
Roh, J.S.1
Teng, A.L.2
Rice, J.A.3
Huang, R.C.4
Davis, J.A.5
-
14
-
-
33947153987
-
Efficacy of computer-assisted pedicle screw insertion for cervical instability in RA patients
-
Ito H, Neo M, Yoshida M, Fujibayashi S, Yoshitomi H, Nakamura T (2006) Efficacy of computer-assisted pedicle screw insertion for cervical instability in RA patients. Rheumatol Int 27:567-574
-
(2006)
Rheumatol Int
, vol.27
, pp. 567-574
-
-
Ito, H.1
Neo, M.2
Yoshida, M.3
Fujibayashi, S.4
Yoshitomi, H.5
Nakamura, T.6
-
15
-
-
33644658640
-
Complications of transpedicular screw fixation in the cervical spine
-
Kast E, Mohr K, Richter H-P, Börm W (2006) Complications of transpedicular screw fixation in the cervical spine. Eur Spine J 15:327-334
-
(2006)
Eur Spine J
, vol.15
, pp. 327-334
-
-
Kast, E.1
Mohr, K.2
Richter, H.-P.3
Börm, W.4
-
16
-
-
0142120120
-
Improved accuracy of computer-asisted cervical pedicle screw insertion
-
Spine 3
-
Kotani Y, Abumi K, Ito M, Minami A (2003) Improved accuracy of computer-asisted cervical pedicle screw insertion. J Neurosurg 99(Spine 3):257-263
-
(2003)
J Neurosurg
, vol.99
, pp. 257-263
-
-
Kotani, Y.1
Abumi, K.2
Ito, M.3
Minami, A.4
-
17
-
-
29444456659
-
The clinical risk of vertebral artery injury from cervical pedicle screws in degenerative vertebrae
-
Neo M, Sakamoto T, Fujibayashi S, Nakamura T (2005) The clinical risk of vertebral artery injury from cervical pedicle screws in degenerative vertebrae. Spine 30:2800-2805
-
(2005)
Spine
, vol.30
, pp. 2800-2805
-
-
Neo, M.1
Sakamoto, T.2
Fujibayashi, S.3
Nakamura, T.4
-
18
-
-
34247200026
-
Computer-assisted screw insertion of cervical disorders in rheumatoid arthritis
-
Takahashi J, Shono Z, Nakamura I, Hirabayashi H, Kamimura M, Ebara S, Kato H (2006) Computer-assisted screw insertion of cervical disorders in rheumatoid arthritis. Eur Spine J 16:485-494
-
(2006)
Eur Spine J
, vol.16
, pp. 485-494
-
-
Takahashi, J.1
Shono, Z.2
Nakamura, I.3
Hirabayashi, H.4
Kamimura, M.5
Ebara, S.6
Kato, H.7
-
19
-
-
13244269897
-
Spinal reconstruction using a cervical pedicle screw system
-
Yoshimoto H, Sato S, Hyakumachi T, Yanagibashi Y, Masuda T (2005) Spinal reconstruction using a cervical pedicle screw system. Clin Orthop Rel Res 431:111-119
-
(2005)
Clin Orthop Rel Res
, vol.431
, pp. 111-119
-
-
Yoshimoto, H.1
Sato, S.2
Hyakumachi, T.3
Yanagibashi, Y.4
Masuda, T.5
-
20
-
-
34548229871
-
Cervical pedicle screw fixation in 100 cases of unstable cervical injuries: Pedicle axis views obtained using fluoroscopy
-
Yukawa Y, Kato F, Yoshirara H, Yanase M, Ito K (2006) Cervical pedicle screw fixation in 100 cases of unstable cervical injuries: pedicle axis views obtained using fluoroscopy. J Neurosurg 5:488-493
-
(2006)
J Neurosurg
, vol.5
, pp. 488-493
-
-
Yukawa, Y.1
Kato, F.2
Yoshirara, H.3
Yanase, M.4
Ito, K.5
-
21
-
-
42149136853
-
Cervical anterior transpedicular screw fixation. Part I: Study on morphological feasibility, indications, and technical prerequisites
-
(in press) [E-pub ahead of print]
-
Koller H, Acosta F, Hempfing A, Scheiter A, Tauber A, Holz U, Resch H, Fox M, Hitzl M (2008). Cervical anterior transpedicular screw fixation. Part I: Study on morphological feasibility, indications, and technical prerequisites. Eur Spine J (in press) [E-pub ahead of print]
-
(2008)
Eur Spine J
-
-
Koller, H.1
Acosta, F.2
Hempfing, A.3
Scheiter, A.4
Tauber, A.5
Holz, U.6
Resch, H.7
Fox, M.8
Hitzl, M.9
-
22
-
-
0031419970
-
Structural characteristics of the pedicle and its role in screw stability
-
Hirano T, Hasegawa K,Takahashi H, Uchiyama S, Hara T, Washio T, Sugiura T, Yokaichiya M, Ideka M (1997) Structural characteristics of the pedicle and its role in screw stability. Spine 22:2504-2510
-
(1997)
Spine
, vol.22
, pp. 2504-2510
-
-
Hirano, T.1
Hasegawa, K.2
Takahashi, H.3
Uchiyama, S.4
Hara, T.5
Washio, T.6
Sugiura, T.7
Yokaichiya, M.8
Ideka, M.9
-
23
-
-
0026445667
-
Anatomical and technical considerations of pedicle screw fixation
-
Weinstein JN, Rydevik BL, Rauschnig WR (1992) Anatomical and technical considerations of pedicle screw fixation. Clin Orthop 284:34-36
-
(1992)
Clin Orthop
, vol.284
, pp. 34-36
-
-
Weinstein, J.N.1
Rydevik, B.L.2
Rauschnig, W.R.3
-
24
-
-
33750537850
-
Cervical pedicle screws vs. lateral mass screws: Uniplanar fatigue analysis and residual pullout strengths
-
Johnston LT, Karaikovic EE, Lautenschlager EP, Marcu D (2006) Cervical pedicle screws vs. lateral mass screws: uniplanar fatigue analysis and residual pullout strengths. Spine J 6:667-672
-
(2006)
Spine J
, vol.6
, pp. 667-672
-
-
Johnston, L.T.1
Karaikovic, E.E.2
Lautenschlager, E.P.3
Marcu, D.4
-
25
-
-
0031010622
-
Cervical pedicle screws versus lateral mass screws: Anatomic feasibility and biomechanical comparison
-
Jones EL, Heller JG, Silcox DH, Hutton WC (1997) Cervical pedicle screws versus lateral mass screws: anatomic feasibility and biomechanical comparison. Spine 22:977-982
-
(1997)
Spine
, vol.22
, pp. 977-982
-
-
Jones, E.L.1
Heller, J.G.2
Silcox, D.H.3
Hutton, W.C.4
-
26
-
-
0027999435
-
Biomechanical analysis of cervical stabilization systems. An assessment of transpedicular screw fixation in the cervical spine
-
Kotani Y, Cunningham BW, Abumi K, McAfee PC (1994) Biomechanical analysis of cervical stabilization systems. An assessment of transpedicular screw fixation in the cervical spine. Spine 19:2529-2539
-
(1994)
Spine
, vol.19
, pp. 2529-2539
-
-
Kotani, Y.1
Cunningham, B.W.2
Abumi, K.3
McAfee, P.C.4
-
27
-
-
4444332803
-
Biomechanical analysis of transpedicular screw fixation in the subaxial cervical spine
-
Kothe R, Rüter W, Schneider E, Linke B (2004) Biomechanical analysis of transpedicular screw fixation in the subaxial cervical spine. Spine 29:1869-1875
-
(2004)
Spine
, vol.29
, pp. 1869-1875
-
-
Kothe, R.1
Rüter, W.2
Schneider, E.3
Linke, B.4
-
28
-
-
0034669665
-
Cervical spine pedicle screws: A biomechanical comparison of two insertion techniques
-
KowalskiJ, Ludwig SC, Hutton WC, Heller JG (2000) Cervical spine pedicle screws: a biomechanical comparison of two insertion techniques. Spine 25:2865-2867
-
(2000)
Spine
, vol.25
, pp. 2865-2867
-
-
Kowalskij1
Ludwig, S.C.2
Hutton, W.C.3
Heller, J.G.4
-
29
-
-
0033564602
-
Reconstruction after multilevel corporectomy in the cervical spine. a sagittal plane biomechanical study
-
Discussion: Traynelis VC: 1191
-
Krikpatrick JS, Levy JA, Carillo J, Moeini SR (1999) Reconstruction after multilevel corporectomy in the cervical spine. A sagittal plane biomechanical study. Spine 24:1186-1191; Discussion: Traynelis VC: 1191
-
(1999)
Spine
, vol.24
, pp. 1186-1191
-
-
Krikpatrick, J.S.1
Levy, J.A.2
Carillo, J.3
Moeini, S.R.4
-
30
-
-
18244409074
-
Biomechanical analysis of rigid stabilization techniques for three-column injury in the lower cervical spine
-
Bozkus H, Ames CP, Chamberlain RH, Nottmeier EW, Sonntag VKH, Papadopoulos SM, Crawford NR (2005) Biomechanical analysis of rigid stabilization techniques for three-column injury in the lower cervical spine. Spine 30:915-922
-
(2005)
Spine
, vol.30
, pp. 915-922
-
-
Bozkus, H.1
Ames, C.P.2
Chamberlain, R.H.3
Nottmeier, E.W.4
Sonntag, V.K.H.5
Papadopoulos, S.M.6
Crawford, N.R.7
-
31
-
-
0035169431
-
A biomechanical comparison of modern anterior and posterior plate fixation of the cervical spine
-
Do Koh Y, Lim TH, Won You J, Eck J, An HS (2001) A biomechanical comparison of modern anterior and posterior plate fixation of the cervical spine. Spine 26:15-21
-
(2001)
Spine
, vol.26
, pp. 15-21
-
-
Do Koh, Y.1
Lim, T.H.2
Won You, J.3
Eck, J.4
An, H.S.5
-
32
-
-
0344604421
-
Stabilizing potential of anterior cervical plates in multilevel corpectomies
-
Isomi T, Panjabi MM, Wang JL, Vaccaro AR, Garfin SR, Patel T (1999) Stabilizing potential of anterior cervical plates in multilevel corpectomies. Spine 24:2219-2223
-
(1999)
Spine
, vol.24
, pp. 2219-2223
-
-
Isomi, T.1
Panjabi, M.M.2
Wang, J.L.3
Vaccaro, A.R.4
Garfin, S.R.5
Patel, T.6
-
33
-
-
0344604421
-
Stabilizing potential of anterior cervical plates in multilevel corporectomies
-
Isomi T Panjabi MM, Wang JL, et al (1999) Stabilizing potential of anterior cervical plates in multilevel corporectomies. Spine 24:2219-2223
-
(1999)
Spine
, vol.24
, pp. 2219-2223
-
-
Isomi Panjabi, T.M.M.1
Wang, J.L.2
-
34
-
-
4143107838
-
A biomechanical comparison of three surgical approaches in bilateral cervical facet dislocation
-
Spine 1
-
Kim S-M, Lim TJ, Paterno J, Park BSJ, Kim DH (2004) A biomechanical comparison of three surgical approaches in bilateral cervical facet dislocation. J Neurosurg 1(Spine 1):108-115
-
(2004)
J Neurosurg
, vol.1
, pp. 108-115
-
-
Kim, S.-M.1
Lim, T.J.2
Paterno, J.3
Park, B.S.J.4
Kim, D.H.5
-
35
-
-
0242301855
-
Posterior cervical fixation using a new polyaxial screw and rod system: Technique and surgical results
-
Article 8
-
Mummaneni PV, Haid RW, Traynelis VC, Sasso RC, Subach BR, Fiore AJ, Rodts GE (2002) Posterior cervical fixation using a new polyaxial screw and rod system: technique and surgical results. Neurosurg Focus 12:Article 8
-
(2002)
Neurosurg Focus
, vol.12
-
-
Mummaneni, P.V.1
Haid, R.W.2
Traynelis, V.C.3
Sasso, R.C.4
Subach, B.R.5
Fiore, A.J.6
Rodts, G.E.7
-
36
-
-
0032707751
-
Loosening at the screw-vertebra junction in multilevel anterior cervical plate constructs
-
Panjabi MM, Isomi T, Wang JL (1999) Loosening at the screw-vertebra junction in multilevel anterior cervical plate constructs. Spine 24:2383-2388
-
(1999)
Spine
, vol.24
, pp. 2383-2388
-
-
Panjabi, M.M.1
Isomi, T.2
Wang, J.L.3
-
37
-
-
0037439134
-
Early reconstruction failures after multilevel cervical corpectomy
-
Sasso RC, Ruggiero RA Jr, Reilly TM, Hall PV (2003) Early reconstruction failures after multilevel cervical corpectomy. Spine 28:140-142
-
(2003)
Spine
, vol.28
, pp. 140-142
-
-
Sasso, R.C.1
Ruggiero Jr., R.A.2
Reilly, T.M.3
Hall, P.V.4
-
38
-
-
21344457217
-
Effect of constrained posterior screw and rod systems for primary stability: Biomechanical in vitro comparison of various instrumentations in a single-level corporectomy model
-
Schmidt R, Wilke HJ, Claes L, Puhl W, Richter M (2005) Effect of constrained posterior screw and rod systems for primary stability: biomechanical in vitro comparison of various instrumentations in a single-level corporectomy model. Eur Spine J 14:372-380
-
(2005)
Eur Spine J
, vol.14
, pp. 372-380
-
-
Schmidt, R.1
Wilke, H.J.2
Claes, L.3
Puhl, W.4
Richter, M.5
-
39
-
-
0041472666
-
Pedicle screws enhance primary stability in multilevel cervical corporectomies: Biomechanical in vitro comparison of different implants including constrained and nonconstrained posterior instruments
-
Schmidt R, Wilke HJ, Claes L, Puhl W, Richter M (2003) Pedicle screws enhance primary stability in multilevel cervical corporectomies: biomechanical in vitro comparison of different implants including constrained and nonconstrained posterior instruments. Spine 16:1821-1828
-
(2003)
Spine
, vol.16
, pp. 1821-1828
-
-
Schmidt, R.1
Wilke, H.J.2
Claes, L.3
Puhl, W.4
Richter, M.5
-
40
-
-
0034432973
-
Single-stage anterior-posterior decompression and stabilization for complex cervical spine disorders
-
Spine 2
-
Schulz KD Jr, McLaughlin MR, Haud RW Jr, et al (2000) Single-stage anterior-posterior decompression and stabilization for complex cervical spine disorders. J Neursurg 93(Spine 2):214-221
-
(2000)
J Neursurg
, vol.93
, pp. 214-221
-
-
Schulz Jr., K.D.1
McLaughlin, M.R.2
Haud Jr., R.W.3
-
41
-
-
0142056035
-
Biomechanical comparison of cervical spine reconstructive techniques after a multilevel corporectomy of the cervical spine
-
Singh K, Vaccaro AR, Kim J, Lorenz EP, Lim TH, An HS (2003) Biomechanical comparison of cervical spine reconstructive techniques after a multilevel corporectomy of the cervical spine. Spine 28:2352-2357
-
(2003)
Spine
, vol.28
, pp. 2352-2357
-
-
Singh, K.1
Vaccaro, A.R.2
Kim, J.3
Lorenz, E.P.4
Lim, T.H.5
An, H.S.6
-
42
-
-
42149104927
-
Cervical or thoracic instrumentation surgery with registration-free 3D-navigation
-
Abstract
-
Ito Y, Kai N, Haesgawa Y, Nakago K, Toda K, Yagata Y, Shibara M (2005) Cervical or thoracic instrumentation surgery with registration-free 3D-navigation. Eur Spine J 14(Suppl 1):Abstract
-
(2005)
Eur Spine J
, vol.14
, Issue.SUPPL. 1
-
-
Ito, Y.1
Kai, N.2
Haesgawa, Y.3
Nakago, K.4
Toda, K.5
Yagata, Y.6
Shibara, M.7
-
43
-
-
24744453503
-
Traumatically induced vertebral artery occlusion associated with cervical spine injuries: Prospective study using magnetic resonance angiography
-
Taneichi H, Suda K, Kajino T, Kaneda K (2005) Traumatically induced vertebral artery occlusion associated with cervical spine injuries: prospective study using magnetic resonance angiography. Spine 30:1955-1962
-
(2005)
Spine
, vol.30
, pp. 1955-1962
-
-
Taneichi, H.1
Suda, K.2
Kajino, T.3
Kaneda, K.4
-
44
-
-
42149171649
-
Complications of cervical spine pedicle screw placement
-
4th edn Lippincott Williams & Wilkins Philadelphia
-
Ludwig SC (2004) Complications of cervical spine pedicle screw placement. In: Clark CR (ed). The cervical spine, 4th edn. Lippincott Williams & Wilkins, Philadelphia
-
(2004)
Clark CR (Ed)
-
-
Ludwig, S.C.1
-
45
-
-
1442324443
-
Investigation of fixation screw pull-out strength on human spine
-
Zhang QH, Tan SH, Chou SM (2004) Investigation of fixation screw pull-out strength on human spine. J Biomech 37:479-485
-
(2004)
J Biomech
, vol.37
, pp. 479-485
-
-
Zhang, Q.H.1
Tan, S.H.2
Chou, S.M.3
-
46
-
-
21644474966
-
Value of intraoperative true latera lradiograph of C2 pedicle for C1-2 transarticular screw insertion
-
Liu J, Shafiq Q, Ebrahim NA, Karkare N, Asaad M, Woldenberg L, Yeasting RA (2005) Value of intraoperative true latera lradiograph of C2 pedicle for C1-2 transarticular screw insertion. Spine J 5:434-440
-
(2005)
Spine J
, vol.5
, pp. 434-440
-
-
Liu, J.1
Shafiq, Q.2
Ebrahim, N.A.3
Karkare, N.4
Asaad, M.5
Woldenberg, L.6
Yeasting, R.A.7
-
47
-
-
31144448850
-
Posterior instrumentation of the cervical spine using the Neon Occipito-Cervical System. Part 2: Cervical and cervicothoracic instrumentation
-
Richter M (2005) Posterior instrumentation of the cervical spine using the Neon Occipito-Cervical System. Part 2: cervical and cervicothoracic instrumentation. Oper Orthop Traumatol 6:579-600
-
(2005)
Oper Orthop Traumatol
, vol.6
, pp. 579-600
-
-
Richter, M.1
-
48
-
-
33745068732
-
Palliative spinal reconstruction using cervical pedicle screws for metastatic lesions of the spine. a retrospective analysis of 32 cases
-
Oda I, Abumi K, Ito M, Kotani Y, Oya T, Hasegawa K, Minami A (2006) Palliative spinal reconstruction using cervical pedicle screws for metastatic lesions of the spine. A retrospective analysis of 32 cases. Spine 31:1439-1444
-
(2006)
Spine
, vol.31
, pp. 1439-1444
-
-
Oda, I.1
Abumi, K.2
Ito, M.3
Kotani, Y.4
Oya, T.5
Hasegawa, K.6
Minami, A.7
-
49
-
-
33748624648
-
Anterior retropharyngeal fixation C1-2 for stabilization of atlantoaxial instabilities. Study of feasibility, technical description and preliminary results
-
Koller H Kammermeier V, Ulbricht D, Assuncao A, Karolus S, v-d Berg B, Holz U (2006) Anterior retropharyngeal fixation C1-2 for stabilization of atlantoaxial instabilities. Study of feasibility, technical description and preliminary results. Eur Spine J 15:1326-1338
-
(2006)
Eur Spine J
, vol.15
, pp. 1326-1338
-
-
Koller Kammermeier, H.V.1
Ulbricht, D.2
Assuncao, A.3
Karolus, S.4
V-D Berg, B.5
Holz, U.6
-
50
-
-
33846683025
-
Pedicle screw placement accuracy
-
Kosmopoulos V, Schizas C (2007) Pedicle screw placement accuracy. Spine 32:E111-E120
-
(2007)
Spine
, vol.32
-
-
Kosmopoulos, V.1
Schizas, C.2
-
51
-
-
0242662355
-
The accuracy of computed tomography in assessing pedicle screw placement
-
Kim HK, Heller JG, Hudgins PA, Fountain JA (2003) The accuracy of computed tomography in assessing pedicle screw placement. Spine 28:2441-2446
-
(2003)
Spine
, vol.28
, pp. 2441-2446
-
-
Kim, H.K.1
Heller, J.G.2
Hudgins, P.A.3
Fountain, J.A.4
-
52
-
-
0036726784
-
Comparison of computerized tomography and direct visualization in thoracic pedicle screw placement
-
Rao G, Brodke D, Rondina M, et al (2002) Comparison of computerized tomography and direct visualization in thoracic pedicle screw placement. J Neurosurgery 97:223-226
-
(2002)
J Neurosurgery
, vol.97
, pp. 223-226
-
-
Rao, G.1
Brodke, D.2
Rondina, M.3
-
53
-
-
33645499877
-
Percutaneous placement of posterior cervical screws using three-dimensional fluoroscopy
-
Langston H, Foley KT (2006) Percutaneous placement of posterior cervical screws using three-dimensional fluoroscopy. Spine 31:536-540
-
(2006)
Spine
, vol.31
, pp. 536-540
-
-
Langston, H.1
Foley, K.T.2
-
54
-
-
2542464857
-
Morphometric study of the thoracic vertebral pedicle in an Indian population
-
Datir SPD, Mitra SR (2004) Morphometric study of the thoracic vertebral pedicle in an Indian population. Spine 29:1174-1181
-
(2004)
Spine
, vol.29
, pp. 1174-1181
-
-
Datir, S.P.D.1
Mitra, S.R.2
-
55
-
-
0035101506
-
Thoracic pedicle: Surgical anatomic evaluation and relations
-
Ugur HC, Attar A, Uz A, Tekdemir I, Egemen N, Genc Y (2001) Thoracic pedicle: surgical anatomic evaluation and relations. J Spinal Disord 14:39-45
-
(2001)
J Spinal Disord
, vol.14
, pp. 39-45
-
-
Ugur, H.C.1
Attar, A.2
Uz, A.3
Tekdemir, I.4
Egemen, N.5
Genc, Y.6
-
56
-
-
0001908749
-
Computer-assisted surgery in posterior instrumentation of the cervical spine: An in-vitro feasibility study
-
Richter M, Amiot LP, Neller S, Kluger P, Puhl W (2000) Computer-assisted surgery in posterior instrumentation of the cervical spine: an in-vitro feasibility study. Eur Spine J 9:S65-70
-
(2000)
Eur Spine J
, vol.9
, pp. 65-70
-
-
Richter, M.1
Amiot, L.P.2
Neller, S.3
Kluger, P.4
Puhl, W.5
-
57
-
-
0036266815
-
Normal variation of vertebra artery on CT angiography and its implications for diagnosis of acquired pathology
-
Sanelli PC, Tong S, Gonzalez G, et al (2002) Normal variation of vertebra artery on CT angiography and its implications for diagnosis of acquired pathology. J Comput Assist Tomogr 26:462-470
-
(2002)
J Comput Assist Tomogr
, vol.26
, pp. 462-470
-
-
Sanelli, P.C.1
Tong, S.2
Gonzalez, G.3
-
58
-
-
0033759317
-
Surgical anatomic evaluation of the cervical pedicle and adjacent neural structures
-
comments 1168-1169
-
Ugur HC, Attar A, Uz A, Tekdemir I, Egemen N, Caglar S, Genc Y (2000) Surgical anatomic evaluation of the cervical pedicle and adjacent neural structures. Neurosurgery 47:1162-1168; comments 1168-1169
-
(2000)
Neurosurgery
, vol.47
, pp. 1162-1168
-
-
Ugur, H.C.1
Attar, A.2
Uz, A.3
Tekdemir, I.4
Egemen, N.5
Caglar, S.6
Genc, Y.7
-
59
-
-
0033105597
-
Anatomic relation between the cervical pedicle and the adjacent neural structures
-
Xu R, Kang A, Ebraheim NA, Xoung RA (1999) Anatomic relation between the cervical pedicle and the adjacent neural structures. Spine 24:451-454
-
(1999)
Spine
, vol.24
, pp. 451-454
-
-
Xu, R.1
Kang, A.2
Ebraheim, N.A.3
Xoung, R.A.4
-
60
-
-
0028882788
-
Complications of posterior cervical plating
-
Heller JG, Silcox DH, Sutterlin CE (1995) Complications of posterior cervical plating. Spine 20:2442-2448
-
(1995)
Spine
, vol.20
, pp. 2442-2448
-
-
Heller, J.G.1
Silcox, D.H.2
Sutterlin, C.E.3
-
62
-
-
0037228899
-
Factors affecting pullout strength of self-drilling and self-tapping anterior cervical screws
-
Hitchon PW, Brenton MD, Coppes JK, From AM, Torner JC (2003) Factors affecting pullout strength of self-drilling and self-tapping anterior cervical screws. Spine 28:9-13
-
(2003)
Spine
, vol.28
, pp. 9-13
-
-
Hitchon, P.W.1
Brenton, M.D.2
Coppes, J.K.3
From, A.M.4
Torner, J.C.5
-
63
-
-
0026447655
-
Pull-out strength of Caspar cervical screw
-
Maiman DJ, Pintar FA, Yoganandan N, Reinartz J, Toselli R, Woodward E, Haid R (1992) Pull-out strength of Caspar cervical screw. Neurosurg 31:1097-1101
-
(1992)
Neurosurg
, vol.31
, pp. 1097-1101
-
-
Maiman, D.J.1
Pintar, F.A.2
Yoganandan, N.3
Reinartz, J.4
Toselli, R.5
Woodward, E.6
Haid, R.7
-
64
-
-
0036035518
-
Screw fixation to the posterior cortical shell does not influence peak torque and pullout in anterior cervical plating
-
Pitzen T, Barbier D, Tintinger F, Steudel WI, Strowitzki M (2002) Screw fixation to the posterior cortical shell does not influence peak torque and pullout in anterior cervical plating. Eur Spine J 11:494-499
-
(2002)
Eur Spine J
, vol.11
, pp. 494-499
-
-
Pitzen, T.1
Barbier, D.2
Tintinger, F.3
Steudel, W.I.4
Strowitzki, M.5
-
65
-
-
37449029967
-
4- and 5-level anterior fusions of the cervical spine: Review of literature and clinical results
-
12
-
Koller H, Hempfing A, Ferraris L, Meier O, Metz-Stavenhagen P (2006) 4- and 5-level anterior fusions of the cervical spine: review of literature and clinical results. Eur Spine J 16(12):2055-2071
-
(2006)
Eur Spine J
, vol.16
, pp. 2055-2071
-
-
Koller, H.1
Hempfing, A.2
Ferraris, L.3
Meier, O.4
Metz-Stavenhagen, P.5
-
66
-
-
0029101673
-
Biomechanical analysis of bone mineral density, inseriton technique, screw torque, and holding strenght of anterior cervical plates
-
Ryken TC, Clausen JD, Traynelis VC, Goel VK (1995) Biomechanical analysis of bone mineral density, inseriton technique, screw torque, and holding strenght of anterior cervical plates. Neurosurgery 83:325-329
-
(1995)
Neurosurgery
, vol.83
, pp. 325-329
-
-
Ryken, T.C.1
Clausen, J.D.2
Traynelis, V.C.3
Goel, V.K.4
-
67
-
-
0033558110
-
The effect of locking fixation screws on the stability of anterior cervical plating
-
Spivak JM, Chen D, Kummer FJ (1999) The effect of locking fixation screws on the stability of anterior cervical plating. Spine 24:334-338
-
(1999)
Spine
, vol.24
, pp. 334-338
-
-
Spivak, J.M.1
Chen, D.2
Kummer, F.J.3
-
68
-
-
0029791895
-
Biomechanical study of screws in the lateral masses: Variables affecting pull-out resistance
-
9
-
Heller JG, Estes BT, M Zaouali M, Diop A (1996) Biomechanical study of screws in the lateral masses: variables affecting pull-out resistance. J Bone Joint Surg Am 78(9):1315-1321
-
(1996)
J Bone Joint Surg Am
, vol.78
, pp. 1315-1321
-
-
Heller, J.G.1
Estes, B.T.2
Zaouali, M.3
Diop, A.4
-
69
-
-
17044368193
-
The biomechanics of iatrogenic spinal destabilization and implant failure
-
Article 2
-
Schlenk RP, Stewart T, Benzel EC (2003) The biomechanics of iatrogenic spinal destabilization and implant failure. Neurosurg Focus 15(3):Article 2
-
(2003)
Neurosurg Focus
, vol.15
, Issue.3
-
-
Schlenk, R.P.1
Stewart, T.2
Benzel, E.C.3
-
70
-
-
34247637260
-
Primary pedicle screw augmentation in osteoporotic lumbar vertebrae-biomechanical analysis of pedicle fixation strength
-
Burval DJ, McLain RF, Milks R, Inceoglu S (2007) Primary pedicle screw augmentation in osteoporotic lumbar vertebrae-biomechanical analysis of pedicle fixation strength. Spine 32:1077-1083
-
(2007)
Spine
, vol.32
, pp. 1077-1083
-
-
Burval, D.J.1
McLain, R.F.2
Milks, R.3
Inceoglu, S.4
-
71
-
-
1542378008
-
Biomechanical evaluation of cervical lateral mass fixation: A comparison of the Roy-Camille and Magerl screw techniques
-
Spine 3
-
Barrey C, Mertens P, Rumelhart C, Cotton F, Jund J, Perrin G (2004) Biomechanical evaluation of cervical lateral mass fixation: a comparison of the Roy-Camille and Magerl screw techniques. J Neurosurg 100(Spine 3):268-276
-
(2004)
J Neurosurg
, vol.100
, pp. 268-276
-
-
Barrey, C.1
Mertens, P.2
Rumelhart, C.3
Cotton, F.4
Jund, J.5
Perrin, G.6
-
72
-
-
0032733596
-
Characteristics of unicortical and bicortical bilateral mass screws in the cervical spine
-
Seybold EA, Baker JA, Criscitiello AA, Ordway BR, Park CK, Connolly PJ (1999) Characteristics of unicortical and bicortical bilateral mass screws in the cervical spine. Spine 24:2397-2403
-
(1999)
Spine
, vol.24
, pp. 2397-2403
-
-
Seybold, E.A.1
Baker, J.A.2
Criscitiello, A.A.3
Ordway, B.R.4
Park, C.K.5
Connolly, P.J.6
|