메뉴 건너뛰기




Volumn 7, Issue 2, 2008, Pages 138-144

Continous versus bolus cardiac output monitoring during orthotopic liver transplantation

Author keywords

Anesthesia; Cardiac output; Liver transplantation; Thermodilution

Indexed keywords

ADULT; AGED; ANALYTICAL ERROR; ANESTHESIA INDUCTION; ARTICLE; BOLUS HEART OUTPUT MONITORING; CARDIOVASCULAR PROCEDURES; CLINICAL ARTICLE; CONTINUOUS HEART OUTPUT MONITORING; CONTROLLED STUDY; FEMALE; HEART HEMODYNAMICS; HEART MUSCLE REPERFUSION; HEART OUTPUT MEASUREMENT; HEMODYNAMIC MONITORING; HUMAN; INTENSIVE CARE; INTERMETHOD COMPARISON; LIVER GRAFT; LIVER TRANSPLANTATION; MALE; MONITOR; RESPONSE TIME; STATISTICAL ANALYSIS; SYSTEMATIC ERROR; TEST RETEST RELIABILITY; THERMODILUTION; COMPARATIVE STUDY; FOLLOW UP; HEART STROKE VOLUME; LIVER FAILURE; METHODOLOGY; MIDDLE AGED; PATHOPHYSIOLOGY; PATIENT MONITORING; PHYSIOLOGY; PROGNOSIS;

EID: 42149110349     PISSN: 14993872     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (15)

References (27)
  • 1
    • 0037391068 scopus 로고    scopus 로고
    • Cardiac output monitoring: Need for improvement?
    • Salmenpera M, Aittomaki J. Cardiac output monitoring: need for improvement? Acta Anaesthesiol Scand 2003;47: 375-377.
    • (2003) Acta Anaesthesiol Scand , vol.47 , pp. 375-377
    • Salmenpera, M.1    Aittomaki, J.2
  • 2
    • 0032983599 scopus 로고    scopus 로고
    • Continuous cardiac output monitoring - further applications of the thermodilution principle
    • Bottiger BW. Continuous cardiac output monitoring - further applications of the thermodilution principle. Intensive Care Med 1999;25:131-133.
    • (1999) Intensive Care Med , vol.25 , pp. 131-133
    • Bottiger, B.W.1
  • 4
    • 0029016594 scopus 로고
    • Evaluation of a new continuous thermodilution cardiac output monitor in critically ill patients: A prospective criterion standard study
    • Haller M, Zollner C, Briegel J, Forst H. Evaluation of a new continuous thermodilution cardiac output monitor in critically ill patients: a prospective criterion standard study. Crit Care Med 1995;23:860-866.
    • (1995) Crit Care Med , vol.23 , pp. 860-866
    • Haller, M.1    Zollner, C.2    Briegel, J.3    Forst, H.4
  • 5
    • 0029992651 scopus 로고    scopus 로고
    • Delayed time response of the continuous cardiac output pulmonary artery catheter
    • Siegel LC, Hennessy MM, Pearl RG. Delayed time response of the continuous cardiac output pulmonary artery catheter. Anesth Analg 1996;83:1173-1177.
    • (1996) Anesth Analg , vol.83 , pp. 1173-1177
    • Siegel, L.C.1    Hennessy, M.M.2    Pearl, R.G.3
  • 6
    • 0032435617 scopus 로고    scopus 로고
    • Continuous cardiac output catheters: Delay in in vitro response time after controlled flow changes
    • Aranda M, Mihm FG, Garrett S, Mihm MN, Pearl RG. Continuous cardiac output catheters: delay in in vitro response time after controlled flow changes. Anesthesiology 1998;89:1592-1595.
    • (1998) Anesthesiology , vol.89 , pp. 1592-1595
    • Aranda, M.1    Mihm, F.G.2    Garrett, S.3    Mihm, M.N.4    Pearl, R.G.5
  • 7
    • 0032802701 scopus 로고    scopus 로고
    • Thermal filament continuous thermodilution cardiac output delayed response limits its value during acute hemodynamic instability
    • Poli de Figueiredo LF, Malbouisson LM, Varicoda EY, Carmona MJ, Auler JO Jr, Rochae Silva M. Thermal filament continuous thermodilution cardiac output delayed response limits its value during acute hemodynamic instability. J Trauma 1999;47:288-293.
    • (1999) J Trauma , vol.47 , pp. 288-293
    • Poli de Figueiredo, L.F.1    Malbouisson, L.M.2    Varicoda, E.Y.3    Carmona, M.J.4    Auler Jr, J.O.5    Rochae Silva, M.6
  • 8
    • 1842300435 scopus 로고    scopus 로고
    • Continuous versus intermittent thermodilution cardiac output measurement during orthotopic liver transplantation
    • Bottiger BW, Sinner B, Motsch J, Bach A, Bauer H, Martin E. Continuous versus intermittent thermodilution cardiac output measurement during orthotopic liver transplantation. Anaesthesia 1997;52:207-214.
    • (1997) Anaesthesia , vol.52 , pp. 207-214
    • Bottiger, B.W.1    Sinner, B.2    Motsch, J.3    Bach, A.4    Bauer, H.5    Martin, E.6
  • 11
    • 0027938298 scopus 로고
    • Is continuous cardiac output measurement using thermodilution reliable in the critically ill patient?
    • Boldt J, Menges T, Wollbrück M, Hammermann H, Hempelmann G. Is continuous cardiac output measurement using thermodilution reliable in the critically ill patient? Crit Care Med 1994;22:1913-1918.
    • (1994) Crit Care Med , vol.22 , pp. 1913-1918
    • Boldt, J.1    Menges, T.2    Wollbrück, M.3    Hammermann, H.4    Hempelmann, G.5
  • 12
    • 0028961244 scopus 로고
    • Continuous cardiac output measurements in the perioperative period
    • Jakobsen CJ, Melsen NC, Andresen EB. Continuous cardiac output measurements in the perioperative period. Acta Anaesthesiol Scand 1995;39:485-488.
    • (1995) Acta Anaesthesiol Scand , vol.39 , pp. 485-488
    • Jakobsen, C.J.1    Melsen, N.C.2    Andresen, E.B.3
  • 14
    • 0029926874 scopus 로고    scopus 로고
    • Semi-continuous versus injectate cardiac output measurement in intensive care patients after cardiac surgery
    • Bottiger BW, Soder M, Rauch H, Bohrer H, Motsch J, Bauer H, et al. Semi-continuous versus injectate cardiac output measurement in intensive care patients after cardiac surgery. Intensive Care Med 1996;22:312-318.
    • (1996) Intensive Care Med , vol.22 , pp. 312-318
    • Bottiger, B.W.1    Soder, M.2    Rauch, H.3    Bohrer, H.4    Motsch, J.5    Bauer, H.6
  • 15
    • 0032912557 scopus 로고    scopus 로고
    • Evaluation of a new continuous thermodilution cardiac output monitor in cardiac surgical patients: A prospective criterion standard study
    • Zollner C, Polasek J, Kilger E, Pichler B, Jaenicke U, Briegel J, et al. Evaluation of a new continuous thermodilution cardiac output monitor in cardiac surgical patients: a prospective criterion standard study. Crit Care Med 1999; 27:293-298.
    • (1999) Crit Care Med , vol.27 , pp. 293-298
    • Zollner, C.1    Polasek, J.2    Kilger, E.3    Pichler, B.4    Jaenicke, U.5    Briegel, J.6
  • 16
    • 0036198399 scopus 로고    scopus 로고
    • Continuous and intermittent cardiac output measurement: Pulmonary artery catheter versus aortic transpulmonary technique
    • Della Rocca G, Costa MG, Pompei L, Coccia C, Pietropaoli P. Continuous and intermittent cardiac output measurement: pulmonary artery catheter versus aortic transpulmonary technique. Br J Anaesth 2002;88:350-356.
    • (2002) Br J Anaesth , vol.88 , pp. 350-356
    • Della Rocca, G.1    Costa, M.G.2    Pompei, L.3    Coccia, C.4    Pietropaoli, P.5
  • 17
    • 0030880954 scopus 로고    scopus 로고
    • Continuous cardiac output monitoring during adult liver transplantation: Thermal filament technique versus bolus thermodilution
    • Greim CA, Roewer N, Thiel H, Laux G, Schulte am Esch J. Continuous cardiac output monitoring during adult liver transplantation: thermal filament technique versus bolus thermodilution. Anesth Analg 1997;85:483-488.
    • (1997) Anesth Analg , vol.85 , pp. 483-488
    • Greim, C.A.1    Roewer, N.2    Thiel, H.3    Laux, G.4    Schulte am Esch, J.5
  • 18
    • 0034005504 scopus 로고    scopus 로고
    • Comparing methods of clinical measurement: Reporting standards for bland and altman analysis
    • Mantha S, Roizen MF, Fleisher LA, Thisted R, Foss J. Comparing methods of clinical measurement: reporting standards for bland and altman analysis. Anesth Analg 2000;90:593-602.
    • (2000) Anesth Analg , vol.90 , pp. 593-602
    • Mantha, S.1    Roizen, M.F.2    Fleisher, L.A.3    Thisted, R.4    Foss, J.5
  • 20
    • 0035569245 scopus 로고    scopus 로고
    • Continuous cardiac output measurements do not agree with conventional bolus thermodilution cardiac output determination
    • Zollner C, Goetz AE, Weis M, Morstedt K, Pichler B, Lamm P, Kilger E, Haller M. Continuous cardiac output measurements do not agree with conventional bolus thermodilution cardiac output determination. Can J Anaesth 2001;48:1143-1147
    • (2001) Can J Anaesth , vol.48 , pp. 1143-1147
    • Zollner, C.1    Goetz, A.E.2    Weis, M.3    Morstedt, K.4    Pichler, B.5    Lamm, P.6    Kilger, E.7    Haller, M.8
  • 21
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 22
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res 1999;8:135-160.
    • (1999) Stat Methods Med Res , vol.8 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 23
    • 0025318042 scopus 로고
    • Comparing methods of measurement: An alternative approach
    • LaMantia KR, O'Connor T, Barash PG. Comparing methods of measurement: an alternative approach. Anesthesiology 1990;72:781-783.
    • (1990) Anesthesiology , vol.72 , pp. 781-783
    • LaMantia, K.R.1    O'Connor, T.2    Barash, P.G.3
  • 24
    • 0020445597 scopus 로고
    • Reliability of the thermodilution method in the determination of cardiac output in clinical practice
    • Stetz CW, Miller RG, Kelly GE, Raffin TA. Reliability of the thermodilution method in the determination of cardiac output in clinical practice. Am Rev Respir Dis 1982;126:1001-1004.
    • (1982) Am Rev Respir Dis , vol.126 , pp. 1001-1004
    • Stetz, C.W.1    Miller, R.G.2    Kelly, G.E.3    Raffin, T.A.4
  • 25
    • 0025900582 scopus 로고
    • Alternatives to Swan-Ganz cardiac output monitoring
    • Moore FA, Haenel JB, Moore EE. Alternatives to Swan-Ganz cardiac output monitoring. Surg Clin North Am 1991;71:699-721.
    • (1991) Surg Clin North Am , vol.71 , pp. 699-721
    • Moore, F.A.1    Haenel, J.B.2    Moore, E.E.3
  • 26
    • 0027137477 scopus 로고
    • Ventilation, thermal noise, and errors in cardiac output measurements after cardiopulmonary bypass
    • Latson TW, Whitten CW, O'Flaherty D. Ventilation, thermal noise, and errors in cardiac output measurements after cardiopulmonary bypass. Anesthesiology 1993;79: 1233-1243.
    • (1993) Anesthesiology , vol.79 , pp. 1233-1243
    • Latson, T.W.1    Whitten, C.W.2    O'Flaherty, D.3
  • 27
    • 0031902328 scopus 로고    scopus 로고
    • Continuous cardiac output: How accurate and how timely?
    • Gardner RM. Continuous cardiac output: how accurate and how timely? Crit Care Med 1998;26:1302-1303.
    • (1998) Crit Care Med , vol.26 , pp. 1302-1303
    • Gardner, R.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.