A multicenter evaluation of a new continuous cardiac output pulmonary artery catheter system

Author keywords

Blood flow velocity; Cardiac output; Cardiovascular diseases, therapy; Catheterization, pulmonary artery; Heart catheterization; Monitoring, physiologic, instrumentation; Prospective studies; Thermodilution, methods of

Indexed keywords

ADULT; AGED; ARTERY CATHETERIZATION; ARTICLE; BLOOD FLOW VELOCITY; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DEVICE; HEART CATHETERIZATION; HEART OUTPUT; HUMAN; LUNG ARTERY; MAJOR CLINICAL STUDY; MULTICENTER STUDY; PATIENT MONITORING; PRIORITY JOURNAL; TECHNIQUE; THERMODILUTION;

EID: 0031928196     PISSN: 00903493     EISSN: None     Source Type: Journal    
DOI: 10.1097/00003246-199808000-00018     Document Type: Article
Times cited : (48)

References (10)
  • 1
    • 0013912689 scopus 로고
    • Measurement of cardiac output by thermal-dilution and direct Fick methods in dogs
    • Khalil H H, Richardson TQ, Guyton AC: Measurement of cardiac output by thermal-dilution and direct Fick methods in dogs. J Appl Physiol 1966; 21: 1131-1135
    • (1966) J Appl Physiol , vol.21 , pp. 1131-1135
    • Khalil, H.H.1    Richardson, T.Q.2    Guyton, A.C.3
  • 2
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between methods of clinical measurement
    • Bland JM, Altman DG: Statistical methods for assessing agreement between methods of clinical measurement. Lancet 1986; i:307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 3
    • 13044304151 scopus 로고
    • The accuracy of continuous versus injectate cardiac output monitoring depends on the level of cardiac output
    • Böttiger BW, Sinner B, Böhrer H, et al: The accuracy of continuous versus injectate cardiac output monitoring depends on the level of cardiac output. Abstr. Anesthesiology 1995; 83(3A): A464
    • (1995) Anesthesiology , vol.83 , Issue.3 A
    • Böttiger, B.W.1    Sinner, B.2    Böhrer, H.3
  • 4
    • 0028605517 scopus 로고
    • Comparison of cardiac output measurements by continuous thermodilution with electromagnetometry in adult cardiac surgical patients
    • Hogue CW, Rosenbloom M, McCawley C, et al: Comparison of cardiac output measurements by continuous thermodilution with electromagnetometry in adult cardiac surgical patients. J Cardiothorac Vasc Anesth 1994; 8: 631-635
    • (1994) J Cardiothorac Vasc Anesth , vol.8 , pp. 631-635
    • Hogue, C.W.1    Rosenbloom, M.2    McCawley, C.3
  • 5
    • 0027938298 scopus 로고
    • Is continuous cardiac output measurement using thermodilution reliable in the critically ill patient?
    • Boldt J, Menges T, Wollbrück M, et al: Is continuous cardiac output measurement using thermodilution reliable in the critically ill patient? Crit Care Med 1994; 22:1913-1918
    • (1994) Crit Care Med , vol.22 , pp. 1913-1918
    • Boldt, J.1    Menges, T.2    Wollbrück, M.3
  • 6
    • 0026695419 scopus 로고
    • Continuous thermodilution cardiac output measurement in intensive care unit patients
    • Yelderman ML, Ramsay MA, Quinn MD, et al: Continuous thermodilution cardiac output measurement in intensive care unit patients. J Cardiothorac Vasc Anesth 1992; 6:270-274
    • (1992) J Cardiothorac Vasc Anesth , vol.6 , pp. 270-274
    • Yelderman, M.L.1    Ramsay, M.A.2    Quinn, M.D.3
  • 7
    • 0020445597 scopus 로고
    • Reliability of the thermodilution method in the determination of cardiac output in clinical practice
    • Stetz CW, Miller RG, Kelly GE, et al: Reliability of the thermodilution method in the determination of cardiac output in clinical practice. Am Rev Respir Dis 1982; 126:1001-1004
    • (1982) Am Rev Respir Dis , vol.126 , pp. 1001-1004
    • Stetz, C.W.1    Miller, R.G.2    Kelly, G.E.3
  • 8
    • 84944367714 scopus 로고
    • Thermodilution cardiac output measurement: Effects of the respiratory cycle on its reproducibility
    • Stevens JH, Raffin TA, Mihm FG, et al: Thermodilution cardiac output measurement: Effects of the respiratory cycle on its reproducibility. JAMA 1985; 253:2240-2242
    • (1985) JAMA , vol.253 , pp. 2240-2242
    • Stevens, J.H.1    Raffin, T.A.2    Mihm, F.G.3
  • 9
    • 0025130516 scopus 로고
    • Continuous measurement of cardiac output with the use of stochastic system identification techniques
    • Yelderman M: Continuous measurement of cardiac output with the use of stochastic system identification techniques. J Clin Monit 1990; 6:322-332
    • (1990) J Clin Monit , vol.6 , pp. 322-332
    • Yelderman, M.1
  • 10
    • 9544228424 scopus 로고    scopus 로고
    • The effectiveness of right heart catheterization in the initial care of critically ill patients
    • Conners AF, Speroff T, Dawson NV, et al: The effectiveness of right heart catheterization in the initial care of critically ill patients. JAMA 1996; 276: 889-897
    • (1996) JAMA , vol.276 , pp. 889-897
    • Conners, A.F.1    Speroff, T.2    Dawson, N.V.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.