메뉴 건너뛰기




Volumn 85, Issue 3, 1997, Pages 483-488

Continuous cardiac output monitoring during adult liver transplantation: Thermal filament technique versus bolus thermodilution

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTERY CATHETERIZATION; ARTICLE; CLINICAL ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; FEMALE; HEART OUTPUT; HUMAN; LIVER TRANSPLANTATION; MALE; PATIENT MONITORING; PRIORITY JOURNAL; PULMONARY ARTERY; TECHNIQUE; THERMODILUTION;

EID: 0030880954     PISSN: 00032999     EISSN: None     Source Type: Journal    
DOI: 10.1097/00000539-199709000-00003     Document Type: Article
Times cited : (37)

References (27)
  • 1
    • 0020445597 scopus 로고
    • Reliability of the thermodilution method in the determination of cardiac output in clinical practice
    • Stetz CW, Miller RG, Kelly GE, Raffin TA. Reliability of the thermodilution method in the determination of cardiac output in clinical practice. Am Rev Respir Dis 1982;126:1001-4.
    • (1982) Am Rev Respir Dis , vol.126 , pp. 1001-1004
    • Stetz, C.W.1    Miller, R.G.2    Kelly, G.E.3    Raffin, T.A.4
  • 2
    • 0027447134 scopus 로고
    • Errors in the measurement of cardiac output by thermodilution
    • Nishikawa T, Dohi S. Errors in the measurement of cardiac output by thermodilution. Can J Anaesth 1993;40:142-53.
    • (1993) Can J Anaesth , vol.40 , pp. 142-153
    • Nishikawa, T.1    Dohi, S.2
  • 3
    • 0022361983 scopus 로고
    • Major errors in thermodilution cardiac output during rapid volume infusions
    • Wetzel RC, Latson TW. Major errors in thermodilution cardiac output during rapid volume infusions. Anesthesiology 1985;62: 684-7.
    • (1985) Anesthesiology , vol.62 , pp. 684-687
    • Wetzel, R.C.1    Latson, T.W.2
  • 4
    • 0025130516 scopus 로고
    • Continuous measurement of cardiac output with the use of stochastic system identification techniques
    • Yelderman M. Continuous measurement of cardiac output with the use of stochastic system identification techniques. J Clin Monit 1990;6:322-32.
    • (1990) J Clin Monit , vol.6 , pp. 322-332
    • Yelderman, M.1
  • 5
    • 0027137477 scopus 로고
    • Ventilation, thermal noise, and errors in cardiac output measurements after cardiopulmonary bypass
    • Latson TW, Whitten CW, O'Flaherty D. Ventilation, thermal noise, and errors in cardiac output measurements after cardiopulmonary bypass. Anesthesiology 1993;79:1233-43.
    • (1993) Anesthesiology , vol.79 , pp. 1233-1243
    • Latson, T.W.1    Whitten, C.W.2    O'Flaherty, D.3
  • 6
    • 0026695419 scopus 로고
    • Continuous thermodilution cardiac output measurements in intensive care unit patients
    • Yelderman ML, Ramsay MA, Quinn MD, et al. Continuous thermodilution cardiac output measurements in intensive care unit patients. J Cardiothorac Vasc Anesth 1992;6:270-4.
    • (1992) J Cardiothorac Vasc Anesth , vol.6 , pp. 270-274
    • Yelderman, M.L.1    Ramsay, M.A.2    Quinn, M.D.3
  • 7
    • 0029401646 scopus 로고
    • Comparison of continuous with intermittent bolus thermodilution cardiac output measurements
    • Ditmyer CE, Shively M, Burns DB, Reichman RT. Comparison of continuous with intermittent bolus thermodilution cardiac output measurements. Am J Crit Care 1995;4:460-5.
    • (1995) Am J Crit Care , vol.4 , pp. 460-465
    • Ditmyer, C.E.1    Shively, M.2    Burns, D.B.3    Reichman, R.T.4
  • 8
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 10
    • 0023434489 scopus 로고
    • Continuous measurement of intracardiac and pulmonary blood flow velocities with transesophageal pulsed Doppler echocardiography: Technique and initial experience
    • Roewer N, Bednarz F, Schulte am Esch J. Continuous measurement of intracardiac and pulmonary blood flow velocities with transesophageal pulsed Doppler echocardiography: technique and initial experience. J Cardiothorac Anesth 1987;1: 418-28.
    • (1987) J Cardiothorac Anesth , vol.1 , pp. 418-428
    • Roewer, N.1    Bednarz, F.2    Schulte Am Esch, J.3
  • 11
  • 12
    • 0028238404 scopus 로고
    • Transtracheal Doppler cardiac output monitoring: Comparison to thermodilution during noncardiac surgery
    • Perrino AC, O'Connor T, Luther M. Transtracheal Doppler cardiac output monitoring: comparison to thermodilution during noncardiac surgery. Anesth Analg 1994;78:1060-6.
    • (1994) Anesth Analg , vol.78 , pp. 1060-1066
    • Perrino, A.C.1    O'Connor, T.2    Luther, M.3
  • 13
    • 0026799450 scopus 로고
    • Continuous thermodilution cardiac output measurement in sheep
    • Yelderman ML, Quinn MD, McKown RC, et al. Continuous thermodilution cardiac output measurement in sheep. J Thorac Cardiovasc Surg 1992;104:315-20.
    • (1992) J Thorac Cardiovasc Surg , vol.104 , pp. 315-320
    • Yelderman, M.L.1    Quinn, M.D.2    McKown, R.C.3
  • 14
    • 0028998611 scopus 로고
    • Continuous versus bolus thermodilution cardiac output measurements - A comparative study
    • Mihaljevic T, von Segesser LK, Tönz M, et al. Continuous versus bolus thermodilution cardiac output measurements - A comparative study. Crit Care Med 1995;23:944-9.
    • (1995) Crit Care Med , vol.23 , pp. 944-949
    • Mihaljevic, T.1    Von Segesser, L.K.2    Tönz, M.3
  • 15
    • 0343118948 scopus 로고
    • Comparison of continual thermodilution cardiac output with electromagnetometry
    • Hogue CW, Cerza RF, Rosenblom M, Lappas DG. Comparison of continual thermodilution cardiac output with electromagnetometry. Anesthesiology 1993;79(Suppl):A467.
    • (1993) Anesthesiology , vol.79 , Issue.SUPPL.
    • Hogue, C.W.1    Cerza, R.F.2    Rosenblom, M.3    Lappas, D.G.4
  • 16
    • 0029154767 scopus 로고
    • Continuous thermodilution cardiac output: Agreement with Fick and bolus thermodilution methods
    • Thrush D, Downs JB, Smith RA. Continuous thermodilution cardiac output: agreement with Fick and bolus thermodilution methods. J Cardiothorac Vasc Anesth 1995;9:399-404.
    • (1995) J Cardiothorac Vasc Anesth , vol.9 , pp. 399-404
    • Thrush, D.1    Downs, J.B.2    Smith, R.A.3
  • 17
    • 0015291993 scopus 로고
    • Measurement of blood flow by thermodilution
    • Ganz W, Swan HJC. Measurement of blood flow by thermodilution. Am J Cardiol 1972;29:241-6.
    • (1972) Am J Cardiol , vol.29 , pp. 241-246
    • Ganz, W.1    Swan, H.J.C.2
  • 18
    • 0026628714 scopus 로고
    • Errors in thermodilution cardiac output measurements caused by rapid pulmonary artery temperature decreases after cardiopulmonary bypass
    • Bazaral MG, Petre J, Novoa R. Errors in thermodilution cardiac output measurements caused by rapid pulmonary artery temperature decreases after cardiopulmonary bypass. Anesthesiology 1992;77:31-7.
    • (1992) Anesthesiology , vol.77 , pp. 31-37
    • Bazaral, M.G.1    Petre, J.2    Novoa, R.3
  • 19
    • 0343990957 scopus 로고
    • Temperature variations in the venous system of dogs
    • Alfonso S, Herrick JF, Youmans WB, et al. Temperature variations in the venous system of dogs. Am J Physiol 1962;203: 278-82.
    • (1962) Am J Physiol , vol.203 , pp. 278-282
    • Alfonso, S.1    Herrick, J.F.2    Youmans, W.B.3
  • 20
    • 0015058059 scopus 로고
    • Limitations of thermal dilution curves for cardiac output determinations
    • Wessel HU, Paul MH, James GW, Grahn AR. Limitations of thermal dilution curves for cardiac output determinations. J Appl Physiol 1971;30:643-52.
    • (1971) J Appl Physiol , vol.30 , pp. 643-652
    • Wessel, H.U.1    Paul, M.H.2    James, G.W.3    Grahn, A.R.4
  • 21
    • 0020202085 scopus 로고
    • Effects of mechanical ventilation on the measurement of cardiac output by thermodilution
    • Snyder JV, Powner DJ. Effects of mechanical ventilation on the measurement of cardiac output by thermodilution. Crit Care Med 1982;10:677-82.
    • (1982) Crit Care Med , vol.10 , pp. 677-682
    • Snyder, J.V.1    Powner, D.J.2
  • 22
    • 0019750941 scopus 로고
    • Effects of the respiratory cycle on cardiac output measurements: Reproducibility of data enhanced by timing the thermodilution injections in dogs
    • Armengol J, Man GCW, Balsys AJ, Wells AL. Effects of the respiratory cycle on cardiac output measurements: reproducibility of data enhanced by timing the thermodilution injections in dogs. Crit Care Med 1981;9:852-4.
    • (1981) Crit Care Med , vol.9 , pp. 852-854
    • Armengol, J.1    Man, G.C.W.2    Balsys, A.J.3    Wells, A.L.4
  • 23
    • 0025221173 scopus 로고
    • An adequate strategy for the thermodilution technique in patients during mechanical ventilation
    • Jansen JRC, Schreuder JJ, Kloek JJ, Versprille A. An adequate strategy for the thermodilution technique in patients during mechanical ventilation. Intensive Care Med 1990;16:422-5.
    • (1990) Intensive Care Med , vol.16 , pp. 422-425
    • Jansen, J.R.C.1    Schreuder, J.J.2    Kloek, J.J.3    Versprille, A.4
  • 24
    • 0023239569 scopus 로고
    • Continuous cardiac output compared to continuous pulmonary artery electromagnetic flow measurement in pigs
    • Davies G, Hess D, Jebson P. Continuous cardiac output compared to continuous pulmonary artery electromagnetic flow measurement in pigs. Anesthesiology 1986;66:805-9.
    • (1986) Anesthesiology , vol.66 , pp. 805-809
    • Davies, G.1    Hess, D.2    Jebson, P.3
  • 25
    • 0021328272 scopus 로고
    • Instrumentation for monitoring gas exchange and metabolic rate in critically ill patients
    • Westenskov DR, Cutler CA, Wallace WD. Instrumentation for monitoring gas exchange and metabolic rate in critically ill patients. Crit Care Med 1984;12:183-8.
    • (1984) Crit Care Med , vol.12 , pp. 183-188
    • Westenskov, D.R.1    Cutler, C.A.2    Wallace, W.D.3
  • 27
    • 0013990851 scopus 로고
    • Effects of respiration and circulation on central blood temperature of the dog
    • Wessel HU, James GW, Paul MH. Effects of respiration and circulation on central blood temperature of the dog. Am J Physiol 1966;211:1403-12.
    • (1966) Am J Physiol , vol.211 , pp. 1403-1412
    • Wessel, H.U.1    James, G.W.2    Paul, M.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.