메뉴 건너뛰기




Volumn 26, Issue 4, 2008, Pages 460-464

Reduction of wear volume from ultrahigh molecular weight polyethylene knee components by the addition of vitamin E

Author keywords

Debris; Knee simulator; UHMWPE; Vitamin E (D,L tocopherol); Wear

Indexed keywords

ALPHA TOCOPHEROL; TITANIUM; ULTRA HIGH MOLECULAR WEIGHT POLYETHYLENE; POLYETHYLENE DERIVATIVE; ULTRA-HIGH MOLECULAR WEIGHT POLYETHYLENE; UNCLASSIFIED DRUG;

EID: 41649091930     PISSN: 07360266     EISSN: None     Source Type: Journal    
DOI: 10.1002/jor.20514     Document Type: Article
Times cited : (59)

References (33)
  • 1
    • 0033628937 scopus 로고    scopus 로고
    • Biological reactions to wear debris in total joint replacement
    • Ingham E, Fisher J. 2000. Biological reactions to wear debris in total joint replacement. Proc Inst Mech Eng H 214:21-37.
    • (2000) Proc Inst Mech Eng H , vol.214 , pp. 21-37
    • Ingham, E.1    Fisher, J.2
  • 2
    • 1842581502 scopus 로고    scopus 로고
    • Mechanisms of failure of total hip replacements lessons learned from retrieval studies
    • Hirakawa K, Jacobs JJ, Urban R, et al. 2004. Mechanisms of failure of total hip replacements lessons learned from retrieval studies. Clin Orthop Relat Res 420:10-17.
    • (2004) Clin Orthop Relat Res , vol.420 , pp. 10-17
    • Hirakawa, K.1    Jacobs, J.J.2    Urban, R.3
  • 3
    • 0030632734 scopus 로고    scopus 로고
    • Biological reaction to debris in relation to joint prostheses
    • Revell PA, Al-Saffar N, Kobayashi A. 1997. Biological reaction to debris in relation to joint prostheses. Proc Inst Mech Eng H 211:187-197.
    • (1997) Proc Inst Mech Eng H , vol.211 , pp. 187-197
    • Revell, P.A.1    Al-Saffar, N.2    Kobayashi, A.3
  • 5
    • 84941911350 scopus 로고    scopus 로고
    • New York: Elsevier Academic Press; 166 p
    • Kurtz S. 2004. The UHMWPE handbook. New York: Elsevier Academic Press; 166 p.
    • (2004) The UHMWPE handbook
    • Kurtz, S.1
  • 6
    • 0032401792 scopus 로고    scopus 로고
    • Polyethylene particles of a "critical size" are necessary for the induction of cytokines by macrophages in vitro
    • Green TR, Fisher J, Stone M, et al. 1998. Polyethylene particles of a "critical size" are necessary for the induction of cytokines by macrophages in vitro. Biomaterials 19:2297-2302.
    • (1998) Biomaterials , vol.19 , pp. 2297-2302
    • Green, T.R.1    Fisher, J.2    Stone, M.3
  • 7
    • 0032772735 scopus 로고    scopus 로고
    • Prevention of fatigue cracks in ultrahigh molecular weight polyethylene joint components by the addition of vitamin E
    • Tomita N, Kitakura T, Onmori N, et al. 1999. Prevention of fatigue cracks in ultrahigh molecular weight polyethylene joint components by the addition of vitamin E. J Biomed Mater Res 48:474-478.
    • (1999) J Biomed Mater Res , vol.48 , pp. 474-478
    • Tomita, N.1    Kitakura, T.2    Onmori, N.3
  • 8
    • 0034096416 scopus 로고    scopus 로고
    • Quantitative analysis of polyethylene wear debris, wear rate and head damage in retrieved Charnley hip prostheses
    • Tipper JL, Ingham E, Hailey JL, et al. 2000. Quantitative analysis of polyethylene wear debris, wear rate and head damage in retrieved Charnley hip prostheses. J Mater Sci Mater Med 11:117-124.
    • (2000) J Mater Sci Mater Med , vol.11 , pp. 117-124
    • Tipper, J.L.1    Ingham, E.2    Hailey, J.L.3
  • 9
    • 33747434108 scopus 로고    scopus 로고
    • Isolation and characterization of UHMWPE wear particles down to ten nanometers in size from in vitro hip and knee joint simulators
    • Tipper JL, Galvin AL, Williams S, et al. 2006. Isolation and characterization of UHMWPE wear particles down to ten nanometers in size from in vitro hip and knee joint simulators. J Biomed Mater Res A 78:473-480.
    • (2006) J Biomed Mater Res A , vol.78 , pp. 473-480
    • Tipper, J.L.1    Galvin, A.L.2    Williams, S.3
  • 10
    • 20444423321 scopus 로고    scopus 로고
    • The anti-oxidative properties of alpha-tocopherol in gamma-irradiated UHMWPE with respect to fatigue and oxidation resistance
    • Shibata N, Tomita N. 2005. The anti-oxidative properties of alpha-tocopherol in gamma-irradiated UHMWPE with respect to fatigue and oxidation resistance. Biomaterials 26:5755-5762.
    • (2005) Biomaterials , vol.26 , pp. 5755-5762
    • Shibata, N.1    Tomita, N.2
  • 11
    • 22544437873 scopus 로고    scopus 로고
    • Characterization of irradiated blends of alpha-tocopherol and UHMWPE
    • Oral E, Greenbaum ES, Malhi AS, et al. 2005. Characterization of irradiated blends of alpha-tocopherol and UHMWPE. Biomaterials 26:6657-6663.
    • (2005) Biomaterials , vol.26 , pp. 6657-6663
    • Oral, E.1    Greenbaum, E.S.2    Malhi, A.S.3
  • 12
    • 33745009957 scopus 로고    scopus 로고
    • Wear resistance and mechanical properties of highly cross-linked, ultrahigh-molecular weight polyethylene doped with vitamin E
    • Oral E, Christensen SD, Malhi AS, et al. 2006. Wear resistance and mechanical properties of highly cross-linked, ultrahigh-molecular weight polyethylene doped with vitamin E. J Arthroplasty 21:580-591.
    • (2006) J Arthroplasty , vol.21 , pp. 580-591
    • Oral, E.1    Christensen, S.D.2    Malhi, A.S.3
  • 13
    • 2342495274 scopus 로고    scopus 로고
    • Alpha-tocopherol-doped irradiated UHMWPE for high fatigue resistance and low wear
    • Oral E, Wannomae KK, Hawkins N, et al. 2004. Alpha-tocopherol-doped irradiated UHMWPE for high fatigue resistance and low wear. Biomaterials 25:5515-5522.
    • (2004) Biomaterials , vol.25 , pp. 5515-5522
    • Oral, E.1    Wannomae, K.K.2    Hawkins, N.3
  • 14
    • 0036181132 scopus 로고    scopus 로고
    • Examination of the suitability of alpha-tocopherol as a stabilizer for ultra-high molecular weight polyethylene used for articulating surfaces in joint endoprostheses
    • Wolf C, Krivec T, Blassnig J, et al. 2002. Examination of the suitability of alpha-tocopherol as a stabilizer for ultra-high molecular weight polyethylene used for articulating surfaces in joint endoprostheses. J Mater Sci Mater Med 13:185-189.
    • (2002) J Mater Sci Mater Med , vol.13 , pp. 185-189
    • Wolf, C.1    Krivec, T.2    Blassnig, J.3
  • 15
    • 0344738773 scopus 로고    scopus 로고
    • Defect initiation at subsurface grain boundary as a precursor of delamination in ultrahigh molecular weight polyethylene
    • Shibata N, Tomita N, Onmori N, et al. 2003. Defect initiation at subsurface grain boundary as a precursor of delamination in ultrahigh molecular weight polyethylene. J Biomed Mater Res A 67:276-284.
    • (2003) J Biomed Mater Res A , vol.67 , pp. 276-284
    • Shibata, N.1    Tomita, N.2    Onmori, N.3
  • 16
    • 0041562688 scopus 로고    scopus 로고
    • Effect of accelerated aging conditions on resultant depth-dependent oxidation and wear resistance of UHMWPE joint replacement bearing materials
    • Toohey SK, Blanchet AT, Heckelman DD. 2003. Effect of accelerated aging conditions on resultant depth-dependent oxidation and wear resistance of UHMWPE joint replacement bearing materials. Wear 255:1076-1084.
    • (2003) Wear , vol.255 , pp. 1076-1084
    • Toohey, S.K.1    Blanchet, A.T.2    Heckelman, D.D.3
  • 17
    • 0035687620 scopus 로고    scopus 로고
    • The effect of accelerated aging on the wear of UHMWPE
    • Sakoda H, Fisher J, Lu S, et al. 2001. The effect of accelerated aging on the wear of UHMWPE. J Mater Sci Mater Med 12:1043-1047.
    • (2001) J Mater Sci Mater Med , vol.12 , pp. 1043-1047
    • Sakoda, H.1    Fisher, J.2    Lu, S.3
  • 18
    • 52449103106 scopus 로고    scopus 로고
    • Oxidation resistance of vitamin E additive ultra high molecular weight polyethylene for an artificial knee joint
    • Teramura S, Tomita N, Kawashima S, et al. 2004. Oxidation resistance of vitamin E additive ultra high molecular weight polyethylene for an artificial knee joint. J Sur Sci Soc Jpn 25:568-572.
    • (2004) J Sur Sci Soc Jpn , vol.25 , pp. 568-572
    • Teramura, S.1    Tomita, N.2    Kawashima, S.3
  • 19
    • 0345524511 scopus 로고    scopus 로고
    • Effect of gamma-irradiated on delamination of ultra-high molecular weight polyethylene (UHMWPE)
    • Shibata N, Tomita N, Ikeuchi K. 2002. Effect of gamma-irradiated on delamination of ultra-high molecular weight polyethylene (UHMWPE). Jpn J Clin Biomech 23:367-371.
    • (2002) Jpn J Clin Biomech , vol.23 , pp. 367-371
    • Shibata, N.1    Tomita, N.2    Ikeuchi, K.3
  • 20
    • 52449110678 scopus 로고    scopus 로고
    • Fatigue performance of UHMWPE mixed with vimitan E supposing lift off in total knee arthroplasty
    • Mori A, Tomita N, Kaneeda T, et al. 2003. Fatigue performance of UHMWPE mixed with vimitan E supposing lift off in total knee arthroplasty. J Jpn Soc Biomater 21:403-409.
    • (2003) J Jpn Soc Biomater , vol.21 , pp. 403-409
    • Mori, A.1    Tomita, N.2    Kaneeda, T.3
  • 21
    • 52449107469 scopus 로고    scopus 로고
    • Wear resistance of UHMWPE mixed vitamin E supposing lift-off in TKA
    • Mori A, Tomita N, Kaneeda T, et al. 2002. Wear resistance of UHMWPE mixed vitamin E supposing lift-off in TKA. Proc 48th Ann Meet Orth Res Soc 1041.
    • (2002) Proc 48th Ann Meet Orth Res Soc , pp. 1041
    • Mori, A.1    Tomita, N.2    Kaneeda, T.3
  • 24
    • 32644454394 scopus 로고    scopus 로고
    • UHMWPE and vitamin E bioactivity: An emerging perspective
    • Reno F, Cannas M. 2006. UHMWPE and vitamin E bioactivity: An emerging perspective. Biomaterials 27:3039-3043.
    • (2006) Biomaterials , vol.27 , pp. 3039-3043
    • Reno, F.1    Cannas, M.2
  • 25
    • 52449092371 scopus 로고    scopus 로고
    • Yamamoto A, Sawae Y, Murakami T. 2005. The influence of protein and lipid concentration on UHMWPE wear behavior. Proceedings of JAST Tribology Conference; p 337-338.
    • Yamamoto A, Sawae Y, Murakami T. 2005. The influence of protein and lipid concentration on UHMWPE wear behavior. Proceedings of JAST Tribology Conference; p 337-338.
  • 26
    • 0035222710 scopus 로고    scopus 로고
    • A novel method for the prediction of functional biological activity of polyethylene wear debris
    • Fisher J, Bell J, Barbour PS, et al. 2001. A novel method for the prediction of functional biological activity of polyethylene wear debris. Proc Inst Mech Eng H 215:127-132.
    • (2001) Proc Inst Mech Eng H , vol.215 , pp. 127-132
    • Fisher, J.1    Bell, J.2    Barbour, P.S.3
  • 27
    • 52449094808 scopus 로고    scopus 로고
    • Fisher J, Matthews B, Besong AA, et al. 2000. Predictions of the functional biological activity of polyethylene wear debris generated in vivo and in vitro. Proc 46th Ann Meet Orth Res Soc; p 588.
    • Fisher J, Matthews B, Besong AA, et al. 2000. Predictions of the functional biological activity of polyethylene wear debris generated in vivo and in vitro. Proc 46th Ann Meet Orth Res Soc; p 588.
  • 28
    • 0032054822 scopus 로고    scopus 로고
    • The influence of sterilization technique and ageing on the structure and morphology of medical-grade ultrahigh molecular weight polyethylene
    • Goldman M, Gronsky R, Pruitt L. 1998. The influence of sterilization technique and ageing on the structure and morphology of medical-grade ultrahigh molecular weight polyethylene. J Mater Sci Mater Med 9:207-212.
    • (1998) J Mater Sci Mater Med , vol.9 , pp. 207-212
    • Goldman, M.1    Gronsky, R.2    Pruitt, L.3
  • 29
    • 0026342453 scopus 로고
    • Articular surface material effect on metal-backed patteller components
    • Milliano TM, Whiteside AL. 1991. Articular surface material effect on metal-backed patteller components. Clin Orthop Relat Res 273:204-214.
    • (1991) Clin Orthop Relat Res , vol.273 , pp. 204-214
    • Milliano, T.M.1    Whiteside, A.L.2
  • 30
    • 0027411489 scopus 로고
    • Evaluation of the effect of the femoral articular surface material on the wear of a metal-backed patellar component
    • Milliano MT, Whiteside LA, Kaiser AD, et al. 1993. Evaluation of the effect of the femoral articular surface material on the wear of a metal-backed patellar component. Clin Orthop Relat Res 287:178-186.
    • (1993) Clin Orthop Relat Res , vol.287 , pp. 178-186
    • Milliano, M.T.1    Whiteside, L.A.2    Kaiser, A.D.3
  • 31
    • 0024095181 scopus 로고
    • Component wear of total knee prostheses using Ti-6A1-4V, titanium nitride coated Ti-6A1-4V, and cobalt-chromium-molybdenum femoral components
    • Peterson CD, Hillberry BM, Heck DA. 1988. Component wear of total knee prostheses using Ti-6A1-4V, titanium nitride coated Ti-6A1-4V, and cobalt-chromium-molybdenum femoral components. J Biomed Mater Res 22:887-903.
    • (1988) J Biomed Mater Res , vol.22 , pp. 887-903
    • Peterson, C.D.1    Hillberry, B.M.2    Heck, D.A.3
  • 32
    • 0028321408 scopus 로고
    • Particulate titanium and cobalt-chrome metallic debris in failed total knee arthroplasty
    • La Budde JK, Orosz JF, Bonfiglio TA, et al. 1994. Particulate titanium and cobalt-chrome metallic debris in failed total knee arthroplasty. J Arthroplasty 9:291-304.
    • (1994) J Arthroplasty , vol.9 , pp. 291-304
    • La Budde, J.K.1    Orosz, J.F.2    Bonfiglio, T.A.3
  • 33
    • 0029725291 scopus 로고    scopus 로고
    • Effect of counterface material on the characteristics of retrieved uncemented cobalt-chromium and titanium alloy total hip replacements
    • Brummitt K, Hardaker CS, McCullagh PJ, et al. 1996. Effect of counterface material on the characteristics of retrieved uncemented cobalt-chromium and titanium alloy total hip replacements. Proc Inst Mech Eng H 210:191-195.
    • (1996) Proc Inst Mech Eng H , vol.210 , pp. 191-195
    • Brummitt, K.1    Hardaker, C.S.2    McCullagh, P.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.