메뉴 건너뛰기




Volumn 19, Issue 4, 2007, Pages 330-335

Real-Time Magnetic Resonance Imaging Guidance for Cardiovascular Procedures

Author keywords

cardiac procedures; imaging; magnetic; real time; resonance

Indexed keywords

ARTICLE; CARDIOVASCULAR PROCEDURES; CARDIOVASCULAR SYSTEM; DEVICE; DIAGNOSTIC IMAGING; DIAGNOSTIC VALUE; ECHOGRAPHY; HUMAN; INTRAOPERATIVE PERIOD; NUCLEAR MAGNETIC RESONANCE IMAGING; NUCLEAR MAGNETIC RESONANCE SCANNER; RADIOGRAPHY; SURGICAL INJURY; SURGICAL INSTRUMENT; SURGICAL TECHNIQUE;

EID: 41549168533     PISSN: 10430679     EISSN: None     Source Type: Journal    
DOI: 10.1053/j.semtcvs.2007.10.006     Document Type: Article
Times cited : (18)

References (29)
  • 1
    • 27744570790 scopus 로고    scopus 로고
    • Cardiovascular interventional magnetic resonance imaging
    • Lederman R.J. Cardiovascular interventional magnetic resonance imaging. Circulation 112 (2005) 3009-3017
    • (2005) Circulation , vol.112 , pp. 3009-3017
    • Lederman, R.J.1
  • 2
    • 0037133679 scopus 로고    scopus 로고
    • Catheter-Based endomyocardial injection with real-time magnetic resonance imaging
    • Lederman R.J., Guttman M.A., Peters D.C., et al. Catheter-Based endomyocardial injection with real-time magnetic resonance imaging. Circulation 105 (2002) 1282-1284
    • (2002) Circulation , vol.105 , pp. 1282-1284
    • Lederman, R.J.1    Guttman, M.A.2    Peters, D.C.3
  • 3
    • 0345167097 scopus 로고    scopus 로고
    • Magnetic resonance fluoroscopy allows targeted delivery of mesenchymal stem cells to infarct borders in swine
    • Dick A.J., Guttman M.A., Raman V.K., et al. Magnetic resonance fluoroscopy allows targeted delivery of mesenchymal stem cells to infarct borders in swine. Circulation 108 (2003) 2899-2904
    • (2003) Circulation , vol.108 , pp. 2899-2904
    • Dick, A.J.1    Guttman, M.A.2    Raman, V.K.3
  • 4
    • 0037648864 scopus 로고    scopus 로고
    • In vivo magnetic resonance imaging of mesenchymal stem cells in myocardial infarction
    • Kraitchman D.L., Heldman A.W., Atalar E., et al. In vivo magnetic resonance imaging of mesenchymal stem cells in myocardial infarction. Circulation 107 (2003) 2290-2293
    • (2003) Circulation , vol.107 , pp. 2290-2293
    • Kraitchman, D.L.1    Heldman, A.W.2    Atalar, E.3
  • 5
    • 23244450802 scopus 로고    scopus 로고
    • Real-time magnetic resonance imaging-guided stenting of aortic coarctation with commercially available catheter devices in swine
    • Raval A.N., Telep J.D., Guttman M.A., et al. Real-time magnetic resonance imaging-guided stenting of aortic coarctation with commercially available catheter devices in swine. Circulation 112 (2005) 699-706
    • (2005) Circulation , vol.112 , pp. 699-706
    • Raval, A.N.1    Telep, J.D.2    Guttman, M.A.3
  • 6
    • 33750626262 scopus 로고    scopus 로고
    • Real-time interactive MRI-guided cardiac surgery: aortic valve replacement using a direct apical approach
    • McVeigh E.R., Guttman M.A., Lederman R.J., et al. Real-time interactive MRI-guided cardiac surgery: aortic valve replacement using a direct apical approach. Magn Reson Med 56 (2006) 958-964
    • (2006) Magn Reson Med , vol.56 , pp. 958-964
    • McVeigh, E.R.1    Guttman, M.A.2    Lederman, R.J.3
  • 7
    • 34547450135 scopus 로고    scopus 로고
    • Beating heart aortic valve replacement using real-time MRI guidance
    • Horvath K.A., Guttman M., Li M., et al. Beating heart aortic valve replacement using real-time MRI guidance. Innovations 2 (2007) 51-55
    • (2007) Innovations , vol.2 , pp. 51-55
    • Horvath, K.A.1    Guttman, M.2    Li, M.3
  • 8
    • 9644259162 scopus 로고    scopus 로고
    • Magnetic resonance imaging-guided transcatheter implantation of a prosthetic valve in aortic valve position: feasibility study in swine
    • Kuehne T., Yilmaz S., Meinus C., et al. Magnetic resonance imaging-guided transcatheter implantation of a prosthetic valve in aortic valve position: feasibility study in swine. J Am Coll Cardiol 44 (2004) 2247-2249
    • (2004) J Am Coll Cardiol , vol.44 , pp. 2247-2249
    • Kuehne, T.1    Yilmaz, S.2    Meinus, C.3
  • 9
    • 0026233069 scopus 로고
    • Phase contrast cine magnetic resonance imaging. Review
    • Pelc N.J., Herfkens R.J., Shimakawa A., et al. Phase contrast cine magnetic resonance imaging. Review. Magn Reson Q 7 (1991) 229-254
    • (1991) Magn Reson Q , vol.7 , pp. 229-254
    • Pelc, N.J.1    Herfkens, R.J.2    Shimakawa, A.3
  • 10
    • 0345742630 scopus 로고    scopus 로고
    • Extended coverage first-pass perfusion imaging using slice-interleaved TSENSE
    • Kellman P., Derbyshire J.A., Agyeman K.O., et al. Extended coverage first-pass perfusion imaging using slice-interleaved TSENSE. Magn Reson Med 51 (2004) 200-204
    • (2004) Magn Reson Med , vol.51 , pp. 200-204
    • Kellman, P.1    Derbyshire, J.A.2    Agyeman, K.O.3
  • 12
  • 13
    • 0043093804 scopus 로고    scopus 로고
    • Real-time accelerated interactive MRI with adaptive TSENSE and UNFOLD
    • Guttman M.A., Kellman P., Dick A.J., et al. Real-time accelerated interactive MRI with adaptive TSENSE and UNFOLD. Magn Reson Med 50 (2003) 315-321
    • (2003) Magn Reson Med , vol.50 , pp. 315-321
    • Guttman, M.A.1    Kellman, P.2    Dick, A.J.3
  • 14
    • 2442547244 scopus 로고    scopus 로고
    • MR-guided intravascular procedures: real-time parameter control and automated slice positioning with active tracking coils
    • Bock M., Volz S., Zuhlsdorff S., et al. MR-guided intravascular procedures: real-time parameter control and automated slice positioning with active tracking coils. J Magn Reson Imaging 19 (2004) 580-589
    • (2004) J Magn Reson Imaging , vol.19 , pp. 580-589
    • Bock, M.1    Volz, S.2    Zuhlsdorff, S.3
  • 16
    • 0030924775 scopus 로고    scopus 로고
    • Guidewire antennas for MR fluoroscopy
    • Ladd M.E., Erhart P., Debatin J.F., et al. Guidewire antennas for MR fluoroscopy. Magn Reson Med 37 (1997) 891-897
    • (1997) Magn Reson Med , vol.37 , pp. 891-897
    • Ladd, M.E.1    Erhart, P.2    Debatin, J.F.3
  • 17
    • 0043093791 scopus 로고    scopus 로고
    • Intravascular extended sensitivity (IVES) MRI antennas
    • Susil R.C., Yeung C.J., and Atalar E. Intravascular extended sensitivity (IVES) MRI antennas. Magn Reson Med 50 (2003) 383-390
    • (2003) Magn Reson Med , vol.50 , pp. 383-390
    • Susil, R.C.1    Yeung, C.J.2    Atalar, E.3
  • 18
    • 1842429552 scopus 로고    scopus 로고
    • Active device tracking and high-resolution intravascular MRI using a novel catheter-based, opposed-solenoid phased array coil
    • Hillenbrand C.M., Elgort D.R., Wong E.Y., et al. Active device tracking and high-resolution intravascular MRI using a novel catheter-based, opposed-solenoid phased array coil. Magn Reson Med 51 (2004) 668-675
    • (2004) Magn Reson Med , vol.51 , pp. 668-675
    • Hillenbrand, C.M.1    Elgort, D.R.2    Wong, E.Y.3
  • 19
    • 0035157985 scopus 로고    scopus 로고
    • Passive tracking of catheters and guidewires by contrast-enhanced MR fluoroscopy
    • Bakker C.J., Bos C., and Weinmann H.J. Passive tracking of catheters and guidewires by contrast-enhanced MR fluoroscopy. Magn Reson Med 45 (2001) 17-23
    • (2001) Magn Reson Med , vol.45 , pp. 17-23
    • Bakker, C.J.1    Bos, C.2    Weinmann, H.J.3
  • 20
    • 7044247646 scopus 로고    scopus 로고
    • Use of a nonmetallic guide wire for magnetic resonance-guided coronary artery catheterization
    • Buecker A., Spuentrup E., Schmitz-Rode T., et al. Use of a nonmetallic guide wire for magnetic resonance-guided coronary artery catheterization. Invest Radiol 39 (2004) 656-660
    • (2004) Invest Radiol , vol.39 , pp. 656-660
    • Buecker, A.1    Spuentrup, E.2    Schmitz-Rode, T.3
  • 21
    • 0035061283 scopus 로고    scopus 로고
    • MR imaging-guided stent placement in iliac arterial stenoses: a feasibility study
    • Manke C., Nitz W.R., Djavidani B., et al. MR imaging-guided stent placement in iliac arterial stenoses: a feasibility study. Radiology 219 (2001) 527-534
    • (2001) Radiology , vol.219 , pp. 527-534
    • Manke, C.1    Nitz, W.R.2    Djavidani, B.3
  • 22
    • 0033800058 scopus 로고    scopus 로고
    • Real-time MR imaging-guided passive catheter tracking with use of gadolinium-filled catheters
    • Omary R.A., Unal O., Koscielski D.S., et al. Real-time MR imaging-guided passive catheter tracking with use of gadolinium-filled catheters. J Vasc Interv Radiol 11 (2000) 1079-1085
    • (2000) J Vasc Interv Radiol , vol.11 , pp. 1079-1085
    • Omary, R.A.1    Unal, O.2    Koscielski, D.S.3
  • 23
    • 0142053953 scopus 로고    scopus 로고
    • Magnetic resonance-guided cardiac catheterization in a swine model of atrial septal defect
    • Schalla S., Saeed M., Higgins C.B., et al. Magnetic resonance-guided cardiac catheterization in a swine model of atrial septal defect. Circulation 108 (2003) 1865-1870
    • (2003) Circulation , vol.108 , pp. 1865-1870
    • Schalla, S.1    Saeed, M.2    Higgins, C.B.3
  • 24
    • 14244255200 scopus 로고    scopus 로고
    • Real-time magnetic resonance guided endomyocardial local delivery
    • Corti R., Badimon J., Mizsei G., et al. Real-time magnetic resonance guided endomyocardial local delivery. Heart 91 (2005) 348-353
    • (2005) Heart , vol.91 , pp. 348-353
    • Corti, R.1    Badimon, J.2    Mizsei, G.3
  • 25
    • 17644381607 scopus 로고    scopus 로고
    • MR-guided percutaneous intramyocardial injection with an MR-compatible catheter: feasibility and changes in T1 values after injection of extracellular contrast medium in pigs
    • Krombach G.A., Pfeffer J.G., Kinzel S., et al. MR-guided percutaneous intramyocardial injection with an MR-compatible catheter: feasibility and changes in T1 values after injection of extracellular contrast medium in pigs. Radiology 235 (2005) 487-494
    • (2005) Radiology , vol.235 , pp. 487-494
    • Krombach, G.A.1    Pfeffer, J.G.2    Kinzel, S.3
  • 26
    • 33645217452 scopus 로고    scopus 로고
    • Feasibility of real-time magnetic resonance-guided stent-graft placement in a swine model of descending aortic dissection
    • Eggebrecht H., Kuhl H., Kaiser G.M., et al. Feasibility of real-time magnetic resonance-guided stent-graft placement in a swine model of descending aortic dissection. Eur Heart J 27 (2006) 613-620
    • (2006) Eur Heart J , vol.27 , pp. 613-620
    • Eggebrecht, H.1    Kuhl, H.2    Kaiser, G.M.3
  • 27
    • 0037133679 scopus 로고    scopus 로고
    • Catheter-based endomyocardial injection with real-time magnetic resonance imaging
    • Lederman R.J., Guttman M.A., Peters D.C., et al. Catheter-based endomyocardial injection with real-time magnetic resonance imaging. Circulation 105 (2002) 1282-1284
    • (2002) Circulation , vol.105 , pp. 1282-1284
    • Lederman, R.J.1    Guttman, M.A.2    Peters, D.C.3
  • 28
    • 0345167097 scopus 로고    scopus 로고
    • Magnetic resonance fluoroscopy allows targeted delivery of mesenchymal stem cells to infarct borders in swine
    • Dick A.J., Guttman M.A., Raman V.K., et al. Magnetic resonance fluoroscopy allows targeted delivery of mesenchymal stem cells to infarct borders in swine. Circulation 108 (2003) 2899-2904
    • (2003) Circulation , vol.108 , pp. 2899-2904
    • Dick, A.J.1    Guttman, M.A.2    Raman, V.K.3
  • 29
    • 23244450802 scopus 로고    scopus 로고
    • Real-time magnetic resonance imaging-guided stenting of aortic coarctation with commercially available catheter devices in swine
    • Raval A.N., Telep J.D., Guttman M.A., et al. Real-time magnetic resonance imaging-guided stenting of aortic coarctation with commercially available catheter devices in swine. Circulation 112 (2005) 699-706
    • (2005) Circulation , vol.112 , pp. 699-706
    • Raval, A.N.1    Telep, J.D.2    Guttman, M.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.