메뉴 건너뛰기




Volumn 160, Issue 4, 2008, Pages 447-454

Development of a myoglobin impedimetric immunosensor based on mixed self-assembled monolayer onto gold

Author keywords

Acute myocardial infarction; Immunosensor; Impedance; Mixed self assembled monolayer; Myoglobin

Indexed keywords


EID: 41549139592     PISSN: 00263672     EISSN: 14365073     Source Type: Journal    
DOI: 10.1007/s00604-007-0793-0     Document Type: Conference Paper
Times cited : (47)

References (46)
  • 1
    • 0031445624 scopus 로고    scopus 로고
    • An immunosensor based on disposable electrodes for rapid estimation of fatty acid-binding protein, an early marker of myocardial infarction
    • A Scheiber R Feldbrugge G Key J C Glatz F Spener 1997 An immunosensor based on disposable electrodes for rapid estimation of fatty acid-binding protein, an early marker of myocardial infarction Biosens Bioelectron 12 1131
    • (1997) Biosens Bioelectron , vol.12 , pp. 1131
    • Scheiber, A.1    Feldbrugge, R.2    Key, G.3    Glatz, J.C.4    Spener, F.5
  • 2
    • 0037166113 scopus 로고    scopus 로고
    • Development of a disposable immunosensor for the detection of human heart fatty-acid binding protein in human whole blood using screen-printed carbon electrodes
    • T M -Regan M Pravda C K O'Sullivan G G Guilbault 2002 Development of a disposable immunosensor for the detection of human heart fatty-acid binding protein in human whole blood using screen-printed carbon electrodes Talanta 57 501
    • (2002) Talanta , vol.57 , pp. 501
    • Regan, T.M.1    Pravda, M.2    O'Sullivan, C.K.3    Guilbault, G.G.4
  • 4
    • 0029688141 scopus 로고    scopus 로고
    • Applications of electrochemical immunosensors to environmental monitoring
    • O A Sadik J M V Emon 1996 Applications of electrochemical immunosensors to environmental monitoring Biosens Bioelectron 11 I
    • (1996) Biosens Bioelectron , vol.11
    • Sadik, O.A.1    Emon, J.M.V.2
  • 5
    • 0030020793 scopus 로고    scopus 로고
    • Immunosensors: Technology and opportunities in laboratory medicine
    • C L Morgan D J Newman C P Price 1996 Immunosensors: technology and opportunities in laboratory medicine Clin Chem 42 193
    • (1996) Clin Chem , vol.42 , pp. 193
    • Morgan, C.L.1    Newman, D.J.2    Price, C.P.3
  • 7
    • 0031309847 scopus 로고    scopus 로고
    • Antibody binding to a functionalized supported lipid layer: A direct acoustic immunosensor
    • E Gizeli M Liley C R Lowe H Vogel 1997 Antibody binding to a functionalized supported lipid layer: a direct acoustic immunosensor Anal Chem 69 4808
    • (1997) Anal Chem , vol.69 , pp. 4808
    • Gizeli, E.1    Liley, M.2    Lowe, C.R.3    Vogel, H.4
  • 8
    • 0028670525 scopus 로고
    • Urea and lactate determined in 1-microL whole-blood samples with a miniaturized thermal biosensor
    • B Xie U Harborn M Mecklenburg B Danielsson 1994 Urea and lactate determined in 1-microL whole-blood samples with a miniaturized thermal biosensor Clin Chem 40 2282
    • (1994) Clin Chem , vol.40 , pp. 2282
    • Xie, B.1    Harborn, U.2    Mecklenburg, M.3    Danielsson, B.4
  • 9
    • 0036633640 scopus 로고    scopus 로고
    • Optical biosensors in drug discovery
    • M A Cooper 2002 Optical biosensors in drug discovery Nat Rev Drug Discov 1 515
    • (2002) Nat Rev Drug Discov , vol.1 , pp. 515
    • Cooper, M.A.1
  • 10
    • 0030879402 scopus 로고    scopus 로고
    • Antibodies for immunosensors a review
    • B Hock 1997 Antibodies for immunosensors a review Anal Chim Acta 347 177
    • (1997) Anal Chim Acta , vol.347 , pp. 177
    • Hock, B.1
  • 11
    • 0032493248 scopus 로고    scopus 로고
    • Oriented immobilization of antibodies for immunosensing
    • M Vikholm W M Albers 1998 Oriented immobilization of antibodies for immunosensing Langmuir 14 3865
    • (1998) Langmuir , vol.14 , pp. 3865
    • Vikholm, M.1    Albers, W.M.2
  • 15
    • 0026351910 scopus 로고
    • Self-assembled organic monolayers: Model systems for studying adsorption of proteins at surfaces
    • K L Prime G M Whitesides 1991 Self-assembled organic monolayers: model systems for studying adsorption of proteins at surfaces Science 24 1164
    • (1991) Science , vol.24 , pp. 1164
    • Prime, K.L.1    Whitesides, G.M.2
  • 16
    • 0027627864 scopus 로고
    • Molecular recognition at self-assembled monolayers: The construction of multicomponent multilayers
    • J Spinke M Liley J H Guder L Angermaier W Knoll 1993 Molecular recognition at self-assembled monolayers: the construction of multicomponent multilayers Langmuir 9 1821
    • (1993) Langmuir , vol.9 , pp. 1821
    • Spinke, J.1    Liley, M.2    Guder, J.H.3    Angermaier, L.4    Knoll, W.5
  • 18
    • 0030077272 scopus 로고    scopus 로고
    • A self-assembled monolayer for the binding and study of histidine-tagged proteins by surface plasmon resonance
    • G B Sigal C Bamdad A Barberis J Strominger G M Whitesides 1996 A self-assembled monolayer for the binding and study of histidine-tagged proteins by surface plasmon resonance Anal Chem 68 490
    • (1996) Anal Chem , vol.68 , pp. 490
    • Sigal, G.B.1    Bamdad, C.2    Barberis, A.3    Strominger, J.4    Whitesides, G.M.5
  • 19
    • 0033524290 scopus 로고    scopus 로고
    • Immobilisation of DNA through intercalation at self-assembled monolayers on gold
    • N Higashi M Takahashi M Niwa 1999 Immobilisation of DNA through intercalation at self-assembled monolayers on gold Langmuir 15 111
    • (1999) Langmuir , vol.15 , pp. 111
    • Higashi, N.1    Takahashi, M.2    Niwa, M.3
  • 20
    • 0035161282 scopus 로고    scopus 로고
    • Immunosensors-principles and applications to clinical chemistry
    • P B Luppa L J Sokoll D W Chan 2001 Immunosensors-principles and applications to clinical chemistry Clin Chim Acta 314 1
    • (2001) Clin Chim Acta , vol.314 , pp. 1
    • Luppa, P.B.1    Sokoll, L.J.2    Chan, D.W.3
  • 21
    • 0043269702 scopus 로고    scopus 로고
    • Probing biomolecular interactions at conductive and semiconductive surfaces by impedance spectroscopy: Routes to impedimetric immunosensors, DNA-sensors, and enzyme biosensors
    • E Katz I Willner 2003 Probing biomolecular interactions at conductive and semiconductive surfaces by impedance spectroscopy: routes to impedimetric immunosensors, DNA-sensors, and enzyme biosensors Electroanal 15 913
    • (2003) Electroanal , vol.15 , pp. 913
    • Katz, E.1    Willner, I.2
  • 23
    • 0031277606 scopus 로고    scopus 로고
    • Capacitive monitoring of protein immobilization and antigen-antibody reactions on monomolecular alkylthiol films on gold electrodes
    • V M Mirsky M Riepl O S Wolfbeis 1997 Capacitive monitoring of protein immobilization and antigen-antibody reactions on monomolecular alkylthiol films on gold electrodes Biosens Bioelectron 12 977
    • (1997) Biosens Bioelectron , vol.12 , pp. 977
    • Mirsky, V.M.1    Riepl, M.2    Wolfbeis, O.S.3
  • 24
    • 0031571838 scopus 로고    scopus 로고
    • Capacitance measurements of antibody-antigen interactions in a flow system
    • C Breggren G Johansson 1997 Capacitance measurements of antibody-antigen interactions in a flow system Anal Chem 69 3651
    • (1997) Anal Chem , vol.69 , pp. 3651
    • Breggren, C.1    Johansson, G.2
  • 25
    • 0034529668 scopus 로고    scopus 로고
    • Sensitive immunodetection through impedance measurements onto gold functionalized electrodes
    • S Ameur C Martelet N Jaffrezic-Renault J M Chovelon 2000 Sensitive immunodetection through impedance measurements onto gold functionalized electrodes Appl Biochem Biotech 89 161
    • (2000) Appl Biochem Biotech , vol.89 , pp. 161
    • Ameur, S.1    Martelet, C.2    Jaffrezic-Renault, N.3    Chovelon, J.M.4
  • 26
    • 0030230964 scopus 로고    scopus 로고
    • The ion selectivity of monensin incorporated phospholipid/alkanethiol bilayers
    • J Li L Ding E Wang S Dong 1996 The ion selectivity of monensin incorporated phospholipid/alkanethiol bilayers J Electroanal Chem 414 17
    • (1996) J Electroanal Chem , vol.414 , pp. 17
    • Li, J.1    Ding, L.2    Wang, E.3    Dong, S.4
  • 27
    • 0029998704 scopus 로고    scopus 로고
    • Impedance analysis of supported lipid bilayer membranes: A scrutiny of different preparation techniques
    • C Steinem A Janshoff W Ulrich M Seiber H Galla 1996 Impedance analysis of supported lipid bilayer membranes: a scrutiny of different preparation techniques Biochim Biophys Acta 1279 169
    • (1996) Biochim Biophys Acta , vol.1279 , pp. 169
    • Steinem, C.1    Janshoff, A.2    Ulrich, W.3    Seiber, M.4    Galla, H.5
  • 28
    • 0030677488 scopus 로고    scopus 로고
    • + sensors based on supported alkanethiol/phospholipid bilayers
    • + sensors based on supported alkanethiol/phospholipid bilayers Thin Sol Films 293 153
    • (1997) Thin Sol Films , vol.293 , pp. 153
    • Wang, E.1    Ding, L.2    Li, J.3    Dong, S.4
  • 29
    • 0032825249 scopus 로고    scopus 로고
    • Highly efficient immobilisation of antibody fragments to functionalised lipid monolayers
    • I Vikholm T Viitala W M Albers J Pelonen 1999 Highly efficient immobilisation of antibody fragments to functionalised lipid monolayers Biochim Biophys Acta 1421 39
    • (1999) Biochim Biophys Acta , vol.1421 , pp. 39
    • Vikholm, I.1    Viitala, T.2    Albers, W.M.3    Pelonen, J.4
  • 30
    • 33645153512 scopus 로고    scopus 로고
    • Development of capacitance based immunosensors on mixed self-assembled monolayer
    • H C W Hays P A Millner M I Prodromidis 2006 Development of capacitance based immunosensors on mixed self-assembled monolayer Sensor Actuat B-chem 114 1064
    • (2006) Sensor Actuat B-chem , vol.114 , pp. 1064
    • Hays, H.C.W.1    Millner, P.A.2    Prodromidis, M.I.3
  • 32
    • 0034099941 scopus 로고    scopus 로고
    • Characteristics of myoglobin, carbonic anhydrase III and the myoglobin/carbonic anhydrase III ratio in trauma, exercise, and myocardial infarction patients
    • J R Beurele H M E Azzazy G Styba S-H Duh R H Christenson 2000 Characteristics of myoglobin, carbonic anhydrase III and the myoglobin/carbonic anhydrase III ratio in trauma, exercise, and myocardial infarction patients Clin Chim Acta 294 115
    • (2000) Clin Chim Acta , vol.294 , pp. 115
    • Beurele, J.R.1    Azzazy, H.M.E.2    Styba, G.3    Duh, S.-H.4    Christenson, R.H.5
  • 34
    • 0032489836 scopus 로고    scopus 로고
    • Diagnostic strategies using myoglobin measurement in myocardial infarction
    • M Plebani M Zaninotto 1998 Diagnostic strategies using myoglobin measurement in myocardial infarction Clin Chim Acta 272 69
    • (1998) Clin Chim Acta , vol.272 , pp. 69
    • Plebani, M.1    Zaninotto, M.2
  • 35
    • 0033231994 scopus 로고    scopus 로고
    • Measurement of myocardial infarct size from plasma fatty acid-binding protein or myoglobin, using individually estimated clearance rates
    • M J M Groot K W H Wodzig M L Simoons J F C Glatz W T Hermens 1999 Measurement of myocardial infarct size from plasma fatty acid-binding protein or myoglobin, using individually estimated clearance rates Cardiovasc Res 44 315
    • (1999) Cardiovasc Res , vol.44 , pp. 315
    • Groot, M.J.M.1    Wodzig, K.W.H.2    Simoons, M.L.3    Glatz, J.F.C.4    Hermens, W.T.5
  • 36
    • 0029946564 scopus 로고    scopus 로고
    • Strategic utilization of cardiac markers for the diagnosis of acute myocardial infarction
    • S S Wong 1996 Strategic utilization of cardiac markers for the diagnosis of acute myocardial infarction Ann Clin Lab Sci 12 301
    • (1996) Ann Clin Lab Sci , vol.12 , pp. 301
    • Wong, S.S.1
  • 37
    • 0032743084 scopus 로고    scopus 로고
    • Troponin-I, myoglobin, and mass concentration of creatine kinase-MB in acute myocardial infarction
    • A Chiu W K Chan S H Cheng C K Leung C H Choi 1999 Troponin-I, myoglobin, and mass concentration of creatine kinase-MB in acute myocardial infarction Q J Med 92 711
    • (1999) Q J Med , vol.92 , pp. 711
    • Chiu, A.1    Chan, W.K.2    Cheng, S.H.3    Leung, C.K.4    Choi, C.H.5
  • 38
    • 0032863780 scopus 로고    scopus 로고
    • The effect of lethal electrical shock on postmortem serum myoglobin concentrations
    • A Fieguth G Schumann H D Troger W J Kleemann 1999 The effect of lethal electrical shock on postmortem serum myoglobin concentrations Forensic Sci Int 105 75
    • (1999) Forensic Sci Int , vol.105 , pp. 75
    • Fieguth, A.1    Schumann, G.2    Troger, H.D.3    Kleemann, W.J.4
  • 39
    • 0029891691 scopus 로고    scopus 로고
    • Serial myoglobin quantitation in the early assessment of myocardial damage: A clinical study
    • D A Gornall S N Roth 1996 Serial myoglobin quantitation in the early assessment of myocardial damage: a clinical study Clin Biochem 29 379
    • (1996) Clin Biochem , vol.29 , pp. 379
    • Gornall, D.A.1    Roth, S.N.2
  • 40
    • 0037413716 scopus 로고    scopus 로고
    • Impedance spectroscopy studies of interfacial acid-base reactions of self-assembled monolayers
    • R Schweiss C Werner W Knoll 2003 Impedance spectroscopy studies of interfacial acid-base reactions of self-assembled monolayers J Electroanal Chem 540 145
    • (2003) J Electroanal Chem , vol.540 , pp. 145
    • Schweiss, R.1    Werner, C.2    Knoll, W.3
  • 41
    • 0031096374 scopus 로고    scopus 로고
    • Three-probe voltammetric characterisation of octadecanethiol self-assembled monolayer integrity on gold electrodes
    • P Krysinski M Brzostowska-Smolska 1997 Three-probe voltammetric characterisation of octadecanethiol self-assembled monolayer integrity on gold electrodes J Electroanal Chem 424 61
    • (1997) J Electroanal Chem , vol.424 , pp. 61
    • Krysinski, P.1    Brzostowska-Smolska, M.2
  • 42
    • 0000025325 scopus 로고
    • Interactions between organized, surface-confined monolayers and liquid-phase probe molecules. 4. Synthesis and characterization of nanoporous molecular assemblies: Mechanism of probe penetration
    • O Cailapakul R M Crooks 1995 Interactions between organized, surface-confined monolayers and liquid-phase probe molecules. 4. Synthesis and characterization of nanoporous molecular assemblies: mechanism of probe penetration Langmuir 11 1329
    • (1995) Langmuir , vol.11 , pp. 1329
    • Cailapakul, O.1    Crooks, R.M.2
  • 43
    • 33845282373 scopus 로고
    • Blocking oriented monolayers of alkyl mercaptans on gold electrodes
    • H O Finklea S Avery M Lynch T Furtsch 1987 Blocking oriented monolayers of alkyl mercaptans on gold electrodes Langmuir 3 409
    • (1987) Langmuir , vol.3 , pp. 409
    • Finklea, H.O.1    Avery, S.2    Lynch, M.3    Furtsch, T.4
  • 44
    • 0035822876 scopus 로고    scopus 로고
    • Formation of a self-assembled monolayer of 2-mercapto-3-n-octylthiophene on gold
    • Z Peng S Dong 2001 Formation of a self-assembled monolayer of 2-mercapto-3-n-octylthiophene on gold Langmuir 17 4904
    • (2001) Langmuir , vol.17 , pp. 4904
    • Peng, Z.1    Dong, S.2
  • 45
    • 84951279351 scopus 로고
    • Use from swinging quartz to the weighing of thin layers and for micro weighing
    • G Sauerbrey 1959 Use from swinging quartz to the weighing of thin layers and for micro weighing Z Phys 155 206
    • (1959) Z Phys , vol.155 , pp. 206
    • Sauerbrey, G.1
  • 46
    • 33646861211 scopus 로고    scopus 로고
    • New analysis from the strength of materials of sauerbrey-s equation concerning the quartz crystal microbalance
    • R Higuchi Y Kanno 2006 New analysis from the strength of materials of sauerbrey-s equation concerning the quartz crystal microbalance Jpn J Appl Phys 45 4232
    • (2006) Jpn J Appl Phys , vol.45 , pp. 4232
    • Higuchi, R.1    Kanno, Y.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.