-
1
-
-
0034255586
-
The deep inspiration breath-hold technique in the treatment of inoperable non-small-cell lung cancer
-
Rosenzweig K.E., Hanley J., Mah D., et al. The deep inspiration breath-hold technique in the treatment of inoperable non-small-cell lung cancer. Int J Radiat Oncol Biol Phys 48 1 (2000) 81-87
-
(2000)
Int J Radiat Oncol Biol Phys
, vol.48
, Issue.1
, pp. 81-87
-
-
Rosenzweig, K.E.1
Hanley, J.2
Mah, D.3
-
2
-
-
0033013520
-
The use of active breathing control (ABC) to reduce margin for breathing motion
-
Wong J.W., Sharpe M.B., Jaffray D.A., et al. The use of active breathing control (ABC) to reduce margin for breathing motion. Int J Radiat Oncol Biol Phys 44 4 (1999) 911-919
-
(1999)
Int J Radiat Oncol Biol Phys
, vol.44
, Issue.4
, pp. 911-919
-
-
Wong, J.W.1
Sharpe, M.B.2
Jaffray, D.A.3
-
3
-
-
0348209614
-
Respiratory gating for liver tumors: use in dose escalation
-
Wagman R., Yorke E., Ford E., et al. Respiratory gating for liver tumors: use in dose escalation. Int J Radiat Oncol Biol Phys 55 3 (2003) 659-668
-
(2003)
Int J Radiat Oncol Biol Phys
, vol.55
, Issue.3
, pp. 659-668
-
-
Wagman, R.1
Yorke, E.2
Ford, E.3
-
4
-
-
0346364988
-
Application of the spirometer in respiratory gated radiotherapy
-
Zhang T., Keller H., O'Brien M.J., Mackie T.R., and Paliwal B. Application of the spirometer in respiratory gated radiotherapy. Med Phys 30 12 (2003) 3165-3171
-
(2003)
Med Phys
, vol.30
, Issue.12
, pp. 3165-3171
-
-
Zhang, T.1
Keller, H.2
O'Brien, M.J.3
Mackie, T.R.4
Paliwal, B.5
-
5
-
-
0034333029
-
Physical aspects of a real-time tumor-tracking system for gated radiotherapy
-
Shirato H., Shimizu S., Kunieda T., et al. Physical aspects of a real-time tumor-tracking system for gated radiotherapy. Int J Radiat Oncol Biol Phys 48 4 (2000) 1187-1195
-
(2000)
Int J Radiat Oncol Biol Phys
, vol.48
, Issue.4
, pp. 1187-1195
-
-
Shirato, H.1
Shimizu, S.2
Kunieda, T.3
-
6
-
-
0037423954
-
Synchronized moving aperture radiation therapy (SMART): average tumour trajectory for lung patients
-
Neicu T., Shirato H., Seppenwoolde Y., and Jiang S.B. Synchronized moving aperture radiation therapy (SMART): average tumour trajectory for lung patients. Phys Med Biol 48 5 (2003) 587-598
-
(2003)
Phys Med Biol
, vol.48
, Issue.5
, pp. 587-598
-
-
Neicu, T.1
Shirato, H.2
Seppenwoolde, Y.3
Jiang, S.B.4
-
7
-
-
0033743945
-
Robotic motion compensation for respiratory movement during radiosurgery
-
Schweikard A., Glosser G., Bodduluri M., Murphy M.J., and Adler J.R. Robotic motion compensation for respiratory movement during radiosurgery. Comput Aided Surg 5 4 (2000) 263-277
-
(2000)
Comput Aided Surg
, vol.5
, Issue.4
, pp. 263-277
-
-
Schweikard, A.1
Glosser, G.2
Bodduluri, M.3
Murphy, M.J.4
Adler, J.R.5
-
10
-
-
0037237809
-
Respiration-correlated spiral CT: a method of measuring respiratory-induced anatomic motion for radiation treatment planning
-
Ford E.C., Mageras G.S., Yorke E., and Ling C.C. Respiration-correlated spiral CT: a method of measuring respiratory-induced anatomic motion for radiation treatment planning. Med Phys 30 1 (2003) 88-97
-
(2003)
Med Phys
, vol.30
, Issue.1
, pp. 88-97
-
-
Ford, E.C.1
Mageras, G.S.2
Yorke, E.3
Ling, C.C.4
-
11
-
-
0037422708
-
Acquiring a four-dimensional computed tomography dataset using an external respiratory signal
-
Vedam S.S., Keall P.J., Kini V.R., Mostafavi H., Shukla H.P., and Mohan R. Acquiring a four-dimensional computed tomography dataset using an external respiratory signal. Phys Med Biol 48 1 (2003) 45-62
-
(2003)
Phys Med Biol
, vol.48
, Issue.1
, pp. 45-62
-
-
Vedam, S.S.1
Keall, P.J.2
Kini, V.R.3
Mostafavi, H.4
Shukla, H.P.5
Mohan, R.6
-
12
-
-
10744222972
-
A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing
-
Low D.A., Nystrom M., Kalinin E., et al. A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing. Med Phys 30 6 (2003) 1254-1263
-
(2003)
Med Phys
, vol.30
, Issue.6
, pp. 1254-1263
-
-
Low, D.A.1
Nystrom, M.2
Kalinin, E.3
-
13
-
-
41449096537
-
-
Sonke J, Remeijer P, Van Herk M. Respiration-correlated cone beam CT: obtaining a four-dimensional data set. Med Phys 2003;30(6):1415.
-
Sonke J, Remeijer P, Van Herk M. Respiration-correlated cone beam CT: obtaining a four-dimensional data set. Med Phys 2003;30(6):1415.
-
-
-
-
14
-
-
41449100228
-
-
Rietzel E, Chen GT, Doppke KP, Pan T, Choi NC, Willett CG. 4D computed tomography for treatment planning. Int J Radiat Oncol Biol Phys 2003;57(2):S232-S233.
-
Rietzel E, Chen GT, Doppke KP, Pan T, Choi NC, Willett CG. 4D computed tomography for treatment planning. Int J Radiat Oncol Biol Phys 2003;57(2):S232-S233.
-
-
-
-
15
-
-
33748322003
-
A continuous 4D motion model from multiple respiratory cycles for use in lung radiotherapy
-
McClelland J.R., Blackall J.M., Tarte S., et al. A continuous 4D motion model from multiple respiratory cycles for use in lung radiotherapy. Med Phys 33 9 (2006) 3348-3358
-
(2006)
Med Phys
, vol.33
, Issue.9
, pp. 3348-3358
-
-
McClelland, J.R.1
Blackall, J.M.2
Tarte, S.3
-
16
-
-
41449084021
-
-
Ahmad S, McClelland J, Chamdler A, Hughes S, Hawkes D, Landau D. Movement of tumour and mediastinal nodes with respiration in patients with non small cell lung cancer (NSCLC). Radiother Oncol 2005;76(S2) [abstract 238].
-
Ahmad S, McClelland J, Chamdler A, Hughes S, Hawkes D, Landau D. Movement of tumour and mediastinal nodes with respiration in patients with non small cell lung cancer (NSCLC). Radiother Oncol 2005;76(S2) [abstract 238].
-
-
-
-
17
-
-
4544224201
-
Internal target volume determined with expansion margins beyond composite gross tumor volume in three-dimensional conformal radiotherapy for lung cancer
-
Shih H.A., Jiang S.B., Aljarrah K.M., Doppke K.P., and Choi N.C. Internal target volume determined with expansion margins beyond composite gross tumor volume in three-dimensional conformal radiotherapy for lung cancer. Int J Radiat Oncol Biol Phys 60 2 (2004) 613-622
-
(2004)
Int J Radiat Oncol Biol Phys
, vol.60
, Issue.2
, pp. 613-622
-
-
Shih, H.A.1
Jiang, S.B.2
Aljarrah, K.M.3
Doppke, K.P.4
Choi, N.C.5
-
18
-
-
0037111515
-
Improvement of three-dimensional treatment planning models of small lung targets using high-speed multi-slice computed tomographic imaging
-
Yamada K., Soejima T., Yoden E., Maruta T., Okayama T., and Sugimura K. Improvement of three-dimensional treatment planning models of small lung targets using high-speed multi-slice computed tomographic imaging. Int J Radiat Oncol Biol Phys 54 4 (2002) 1210-1216
-
(2002)
Int J Radiat Oncol Biol Phys
, vol.54
, Issue.4
, pp. 1210-1216
-
-
Yamada, K.1
Soejima, T.2
Yoden, E.3
Maruta, T.4
Okayama, T.5
Sugimura, K.6
-
19
-
-
1542376201
-
Evaluation of the influence of breathing on the movement and modeling of lung tumors
-
Allen A.M., Siracuse K.M., Hayman J.A., and Balter J.M. Evaluation of the influence of breathing on the movement and modeling of lung tumors. Int J Radiat Oncol Biol Phys 58 4 (2004) 1251-1257
-
(2004)
Int J Radiat Oncol Biol Phys
, vol.58
, Issue.4
, pp. 1251-1257
-
-
Allen, A.M.1
Siracuse, K.M.2
Hayman, J.A.3
Balter, J.M.4
-
20
-
-
27744457314
-
The need for rotational margins in intensity-modulated radiotherapy and a new method for planning target volume design
-
Langer M.P., Papiez L., Spirydovich S., and Thai V. The need for rotational margins in intensity-modulated radiotherapy and a new method for planning target volume design. Int J Radiat Oncol Biol Phys 63 5 (2005) 1592-1603
-
(2005)
Int J Radiat Oncol Biol Phys
, vol.63
, Issue.5
, pp. 1592-1603
-
-
Langer, M.P.1
Papiez, L.2
Spirydovich, S.3
Thai, V.4
-
21
-
-
0035450265
-
Respiratory-driven lung tumor motion is independent of tumor size, tumor location, and pulmonary function
-
Stevens C.W., Munden R.F., Forster K.M., et al. Respiratory-driven lung tumor motion is independent of tumor size, tumor location, and pulmonary function. Int J Radiat Oncol Biol Phys 51 1 (2001) 62-68
-
(2001)
Int J Radiat Oncol Biol Phys
, vol.51
, Issue.1
, pp. 62-68
-
-
Stevens, C.W.1
Munden, R.F.2
Forster, K.M.3
-
22
-
-
0038300496
-
Tumor location cannot predict the mobility of lung tumors: a 3D analysis of data generated from multiple CT scans
-
van Sornsen de Koste J.R., Lagerwaard F.J., Nijssen-Visser M.R., Graveland W.J., and Senan S. Tumor location cannot predict the mobility of lung tumors: a 3D analysis of data generated from multiple CT scans. Int J Radiat Oncol Biol Phys 56 2 (2003) 348-354
-
(2003)
Int J Radiat Oncol Biol Phys
, vol.56
, Issue.2
, pp. 348-354
-
-
van Sornsen de Koste, J.R.1
Lagerwaard, F.J.2
Nijssen-Visser, M.R.3
Graveland, W.J.4
Senan, S.5
-
23
-
-
12844252040
-
Analysis of the movement of calcified lymph nodes during breathing
-
Jenkins P., Salmon C., and Mannion C. Analysis of the movement of calcified lymph nodes during breathing. Int J Radiat Oncol Biol Phys 61 2 (2005) 329-334
-
(2005)
Int J Radiat Oncol Biol Phys
, vol.61
, Issue.2
, pp. 329-334
-
-
Jenkins, P.1
Salmon, C.2
Mannion, C.3
-
24
-
-
0029817312
-
Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing
-
Balter J.M., Ten Haken R.K., Lawrence T.S., Lam K.L., and Robertson J.M. Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing. Int J Radiat Oncol Biol Phys 36 1 (1996) 167-174
-
(1996)
Int J Radiat Oncol Biol Phys
, vol.36
, Issue.1
, pp. 167-174
-
-
Balter, J.M.1
Ten Haken, R.K.2
Lawrence, T.S.3
Lam, K.L.4
Robertson, J.M.5
-
25
-
-
0031803931
-
Improvement of CT-based treatment-planning models of abdominal targets using static exhale imaging
-
Balter J.M., Lam K.L., McGinn C.J., Lawrence T.S., and Ten Haken R.K. Improvement of CT-based treatment-planning models of abdominal targets using static exhale imaging. Int J Radiat Oncol Biol Phys 41 4 (1998) 939-943
-
(1998)
Int J Radiat Oncol Biol Phys
, vol.41
, Issue.4
, pp. 939-943
-
-
Balter, J.M.1
Lam, K.L.2
McGinn, C.J.3
Lawrence, T.S.4
Ten Haken, R.K.5
-
26
-
-
0036703576
-
Integration of digital fluoroscopy with CT-based radiation therapy planning of lung tumors
-
Ruschin M., and Sixel K.E. Integration of digital fluoroscopy with CT-based radiation therapy planning of lung tumors. Med Phys 29 8 (2002) 1698-1709
-
(2002)
Med Phys
, vol.29
, Issue.8
, pp. 1698-1709
-
-
Ruschin, M.1
Sixel, K.E.2
-
27
-
-
0141727529
-
Digital fluoroscopy to quantify lung tumor motion: potential for patient-specific planning target volumes
-
Sixel K.E., Ruschin M., Tirona R., and Cheung P.C. Digital fluoroscopy to quantify lung tumor motion: potential for patient-specific planning target volumes. Int J Radiat Oncol Biol Phys 57 3 (2003) 717-723
-
(2003)
Int J Radiat Oncol Biol Phys
, vol.57
, Issue.3
, pp. 717-723
-
-
Sixel, K.E.1
Ruschin, M.2
Tirona, R.3
Cheung, P.C.4
-
28
-
-
0344406054
-
Are multiple CT scans required for planning curative radiotherapy in lung tumors of the lower lobe?
-
de Koste J.R., Lagerwaard F.J., de Boer H.C., Nijssen-Visser M.R., and Senan S. Are multiple CT scans required for planning curative radiotherapy in lung tumors of the lower lobe?. Int J Radiat Oncol Biol Phys 55 5 (2003) 1394-1399
-
(2003)
Int J Radiat Oncol Biol Phys
, vol.55
, Issue.5
, pp. 1394-1399
-
-
de Koste, J.R.1
Lagerwaard, F.J.2
de Boer, H.C.3
Nijssen-Visser, M.R.4
Senan, S.5
-
30
-
-
20444407977
-
Radiotherapy planning for lung cancer: slow CTs allow the drawing of tighter margins
-
Wurstbauer K., Deutschmann H., Kopp P., and Sedlmayer F. Radiotherapy planning for lung cancer: slow CTs allow the drawing of tighter margins. Radiother Oncol 75 2 (2005) 165-170
-
(2005)
Radiother Oncol
, vol.75
, Issue.2
, pp. 165-170
-
-
Wurstbauer, K.1
Deutschmann, H.2
Kopp, P.3
Sedlmayer, F.4
-
31
-
-
31344477074
-
Physical evaluation of CT scan methods for radiation therapy planning: comparison of fast, slow and gating scan using the 256-detector row CT scanner
-
Mori S., Kanematsu N., Mizuno H., Sunaoka M., and Endo M. Physical evaluation of CT scan methods for radiation therapy planning: comparison of fast, slow and gating scan using the 256-detector row CT scanner. Phys Med Biol 51 3 (2006) 587-600
-
(2006)
Phys Med Biol
, vol.51
, Issue.3
, pp. 587-600
-
-
Mori, S.1
Kanematsu, N.2
Mizuno, H.3
Sunaoka, M.4
Endo, M.5
-
32
-
-
0034721257
-
Preoperative staging of non-small-cell lung cancer with positron-emission tomography
-
Pieterman R.M., van Putten J.W., Meuzelaar J.J., et al. Preoperative staging of non-small-cell lung cancer with positron-emission tomography. N Engl J Med 343 4 (2000) 254-261
-
(2000)
N Engl J Med
, vol.343
, Issue.4
, pp. 254-261
-
-
Pieterman, R.M.1
van Putten, J.W.2
Meuzelaar, J.J.3
-
33
-
-
0037376967
-
Can PET provide the 3D extent of tumor motion for individualized internal target volumes? A phantom study of the limitations of CT and the promise of PET
-
Caldwell C.B., Mah K., Skinner M., and Danjoux C.E. Can PET provide the 3D extent of tumor motion for individualized internal target volumes? A phantom study of the limitations of CT and the promise of PET. Int J Radiat Oncol Biol Phys 55 5 (2003) 1381-1393
-
(2003)
Int J Radiat Oncol Biol Phys
, vol.55
, Issue.5
, pp. 1381-1393
-
-
Caldwell, C.B.1
Mah, K.2
Skinner, M.3
Danjoux, C.E.4
-
34
-
-
41449088669
-
Can positron emission tomography (PET) provide individualized internal target volumes (ITV)? A physiological phantom study and clinical validation
-
[abstract 40]
-
Mah K., Caldwell C., Danjoux C., Skinner M., Tirona R., and Zhang B. Can positron emission tomography (PET) provide individualized internal target volumes (ITV)? A physiological phantom study and clinical validation. Int J Radiat Oncol Biol Phys 60 1 (2004) S152 [abstract 40]
-
(2004)
Int J Radiat Oncol Biol Phys
, vol.60
, Issue.1
-
-
Mah, K.1
Caldwell, C.2
Danjoux, C.3
Skinner, M.4
Tirona, R.5
Zhang, B.6
-
35
-
-
17844388851
-
Does registration of PET and planning CT images decrease interobserver and intraobserver variation in delineating tumor volumes for non-small-cell lung cancer?
-
Fox J.L., Rengan R., O'Meara W., et al. Does registration of PET and planning CT images decrease interobserver and intraobserver variation in delineating tumor volumes for non-small-cell lung cancer?. Int J Radiat Oncol Biol Phys 62 1 (2005) 70-75
-
(2005)
Int J Radiat Oncol Biol Phys
, vol.62
, Issue.1
, pp. 70-75
-
-
Fox, J.L.1
Rengan, R.2
O'Meara, W.3
-
36
-
-
27144488327
-
Positron emission tomography for target volume definition in the treatment of non-small cell lung cancer
-
Lavrenkov K., Partridge M., Cook G., and Brada M. Positron emission tomography for target volume definition in the treatment of non-small cell lung cancer. Radiother Oncol 77 1 (2005) 1-4
-
(2005)
Radiother Oncol
, vol.77
, Issue.1
, pp. 1-4
-
-
Lavrenkov, K.1
Partridge, M.2
Cook, G.3
Brada, M.4
-
37
-
-
30544446003
-
Reduction of observer variation using matched CT-PET for lung cancer delineation: a three-dimensional analysis
-
Steenbakkers R.J., Duppen J.C., Fitton I., et al. Reduction of observer variation using matched CT-PET for lung cancer delineation: a three-dimensional analysis. Int J Radiat Oncol Biol Phys 64 2 (2006) 435-448
-
(2006)
Int J Radiat Oncol Biol Phys
, vol.64
, Issue.2
, pp. 435-448
-
-
Steenbakkers, R.J.1
Duppen, J.C.2
Fitton, I.3
-
38
-
-
33645015648
-
Radiation dose reduction in four-dimensional computed tomography
-
Li T., Schreibmann E., Thorndyke B., et al. Radiation dose reduction in four-dimensional computed tomography. Med Phys 32 12 (2005) 3650-3660
-
(2005)
Med Phys
, vol.32
, Issue.12
, pp. 3650-3660
-
-
Li, T.1
Schreibmann, E.2
Thorndyke, B.3
-
39
-
-
33745071905
-
A novel four-dimensional radiotherapy method for lung cancer: imaging, treatment planning and delivery
-
Alasti H., Cho Y.B., Vandermeer A.D., et al. A novel four-dimensional radiotherapy method for lung cancer: imaging, treatment planning and delivery. Phys Med Biol 51 12 (2006) 3251-3267
-
(2006)
Phys Med Biol
, vol.51
, Issue.12
, pp. 3251-3267
-
-
Alasti, H.1
Cho, Y.B.2
Vandermeer, A.D.3
-
41
-
-
7444226933
-
Four-dimensional CT scans for treatment planning in stereotactic radiotherapy for stage I lung cancer
-
Underberg R.W., Lagerwaard F.J., Cuijpers J.P., Slotman B.J., van Sornsen de Koste J.R., and Senan S. Four-dimensional CT scans for treatment planning in stereotactic radiotherapy for stage I lung cancer. Int J Radiat Oncol Biol Phys 60 4 (2004) 1283-1290
-
(2004)
Int J Radiat Oncol Biol Phys
, vol.60
, Issue.4
, pp. 1283-1290
-
-
Underberg, R.W.1
Lagerwaard, F.J.2
Cuijpers, J.P.3
Slotman, B.J.4
van Sornsen de Koste, J.R.5
Senan, S.6
-
42
-
-
41449099454
-
Semi-automatic delineation of moving lung tumours using deformation fields based on respiration correlated CT: improvement on the internal target volume definition
-
[abstract 247]
-
Janssens G., Orban de Xivry J., Bosmans G., et al. Semi-automatic delineation of moving lung tumours using deformation fields based on respiration correlated CT: improvement on the internal target volume definition. Radiother Oncol 81 S1 (2006) S98 [abstract 247]
-
(2006)
Radiother Oncol
, vol.81
, Issue.SUPPL.1
-
-
Janssens, G.1
Orban de Xivry, J.2
Bosmans, G.3
-
43
-
-
26944441695
-
Use of maximum intensity projections (MIP) for target volume generation in 4DCT scans for lung cancer
-
Underberg R.W., Lagerwaard F.J., Slotman B.J., Cuijpers J.P., and Senan S. Use of maximum intensity projections (MIP) for target volume generation in 4DCT scans for lung cancer. Int J Radiat Oncol Biol Phys 63 1 (2005) 253-260
-
(2005)
Int J Radiat Oncol Biol Phys
, vol.63
, Issue.1
, pp. 253-260
-
-
Underberg, R.W.1
Lagerwaard, F.J.2
Slotman, B.J.3
Cuijpers, J.P.4
Senan, S.5
-
44
-
-
31844431555
-
Color intensity projections: a rapid approach for evaluating four-dimensional CT scans in treatment planning
-
Cover K.S., Lagerwaard F.J., and Senan S. Color intensity projections: a rapid approach for evaluating four-dimensional CT scans in treatment planning. Int J Radiat Oncol Biol Phys 64 3 (2006) 954-961
-
(2006)
Int J Radiat Oncol Biol Phys
, vol.64
, Issue.3
, pp. 954-961
-
-
Cover, K.S.1
Lagerwaard, F.J.2
Senan, S.3
|