Physical evaluation of CT scan methods for radiation therapy planning: Comparison of fast, slow and gating scan using the 256-detector row CT scanner

Author keywords

[No Author keywords available]

Indexed keywords

PATIENT TREATMENT; RADIOTHERAPY; RESPIRATORY SYSTEM; RESPIRATORY THERAPY; TOXICITY;

EID: 31344477074     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/51/3/008     Document Type: Article
Times cited : (22)

References (25)
  • 1
    • 0344406054 scopus 로고    scopus 로고
    • Are multiple CT scans required for planning curative radiotherapy in lung tumors of the lower lobe?
    • de Koste J et al 2003 Are multiple CT scans required for planning curative radiotherapy in lung tumors of the lower lobe? Int. J. Radiat. Oncol. Biol. Phys. 55 1394-9
    • (2003) Int. J. Radiat. Oncol. Biol. Phys. , vol.55 , Issue.5 , pp. 1394-1399
    • De Koste, J.1    Al, E.2
  • 2
    • 10744231515 scopus 로고    scopus 로고
    • Development and performance evaluation of the first model of 4D CT-scanner
    • Endo M et al 2003 Development and performance evaluation of the first model of 4D CT-scanner IEEE Trans. Nucl. Sci. 50 1667-71
    • (2003) IEEE Trans. Nucl. Sci. , vol.50 , Issue.5 , pp. 1667-1671
    • Endo, M.1    Al, E.2
  • 4
    • 21144470584 scopus 로고    scopus 로고
    • Cardiovascular circulation and hepatic perfusion of pigs in 4-dimensional films evaluated by 267-slice cone-beam computed tomography
    • Funabashi N et al 2005 Cardiovascular circulation and hepatic perfusion of pigs in 4-dimensional films evaluated by 267-slice cone-beam computed tomography Circ. J. 69 585-9
    • (2005) Circ. J. , vol.69 , Issue.5 , pp. 585-589
    • Funabashi, N.1    Al, E.2
  • 5
    • 0032844267 scopus 로고    scopus 로고
    • Deep inspiration breathhold technique for lung tumors: The potential value of target immobilization and reduced lung density in dose escalation
    • Hanley J et al 1999 Deep inspiration breathhold technique for lung tumors: the potential value of target immobilization and reduced lung density in dose escalation Int. J. Radiat. Oncol. Biol. Phys. 45 603-11
    • (1999) Int. J. Radiat. Oncol. Biol. Phys. , vol.45 , Issue.3 , pp. 603-611
    • Hanley, J.1    Al, E.2
  • 6
    • 4544224201 scopus 로고    scopus 로고
    • Internal target volume determined with expansion margins beyond composite gross tumor volume in three-dimensional conformal radiotherapy for lung cancer
    • Helen A S et al 2004 Internal target volume determined with expansion margins beyond composite gross tumor volume in three-dimensional conformal radiotherapy for lung cancer Int. J. Radiat. Oncol. Biol. Phys. 60 613-22
    • (2004) Int. J. Radiat. Oncol. Biol. Phys. , vol.60 , Issue.2 , pp. 613-622
    • Helen, A.S.1    Al, E.2
  • 7
    • 0003418872 scopus 로고
    • ICRU 1993 Prescribing, Recording and Reporting Photon Beam Therapy ICRU Report 50 (Bethesda, MD: International Commission on Radiation Units and Measurements)
    • (1993) ICRU Report 50
    • Icru1
  • 8
    • 0003418875 scopus 로고    scopus 로고
    • ICRU 1999 Prescribing, Recording and Reporting Photon Beam Therapy (supplement to ICRU Report 50) ICRU Report 62 (Bethesda, MD: International Commission on Radiation Units and Measurements)
    • (1999) ICRU Report 62
    • Icru1
  • 9
    • 0037691489 scopus 로고    scopus 로고
    • A CT calibration method based on the polybinary tissue model for radiotherapy treatment planning
    • Kanematsu N et al 2003 A CT calibration method based on the polybinary tissue model for radiotherapy treatment planning Phys. Med. Biol. 48 1053-64
    • (2003) Phys. Med. Biol. , vol.48 , Issue.8 , pp. 1053-1064
    • Kanematsu, N.1    Al, E.2
  • 10
    • 17844385102 scopus 로고    scopus 로고
    • Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking
    • Keall P J et al 2005 Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking Med. Phys. 32 942-51
    • (2005) Med. Phys. , vol.32 , Issue.4 , pp. 942-951
    • Keall, P.J.1    Al, E.2
  • 11
    • 0000697171 scopus 로고    scopus 로고
    • Preliminary results from a study of a respiratory motion tracking system: Underestimation of target volume with conventional CT simulation
    • Kini V R et al 2000 Preliminary results from a study of a respiratory motion tracking system: underestimation of target volume with conventional CT simulation Int. J. Radiat. Oncol. Biol. Phys. 8 (Suppl. 1) 164
    • (2000) Int. J. Radiat. Oncol. Biol. Phys. , vol.48 , Issue.3 , pp. 164
    • Kini, V.R.1    Al, E.2
  • 12
    • 85135546812 scopus 로고    scopus 로고
    • Real-time volumetric imaging of human heart without ECG gating by 256-detector row computed tomography: Initial experience
    • Kondo C et al 2005 Real-time volumetric imaging of human heart without ECG gating by 256-detector row computed tomography: initial experience J. Comput. Assist. Tomogr.
    • (2005) J. Comput. Assist. Tomogr.
    • Kondo, C.1    Al, E.2
  • 13
    • 0035889295 scopus 로고    scopus 로고
    • Multiple 'slow' CT scans for incorporating lung tumor mobility in radiotherapy planning
    • Lagerwaard F J et al 2001 Multiple 'slow' CT scans for incorporating lung tumor mobility in radiotherapy planning Int. J. Radiat. Oncol. Biol. Phys. 51 932-7
    • (2001) Int. J. Radiat. Oncol. Biol. Phys. , vol.51 , Issue.4 , pp. 932-937
    • Lagerwaard, F.J.1    Al, E.2
  • 14
    • 23844544576 scopus 로고    scopus 로고
    • Respiratory motion-induced treatment uncertainties
    • Mageras G S 1999 Respiratory motion-induced treatment uncertainties Physica Medica 15 199
    • (1999) Physica Medica , vol.15 , pp. 199
    • Mageras, G.S.1
  • 15
    • 0034333267 scopus 로고    scopus 로고
    • Technical aspects of the deep inspiration breath-hold technique in the treatment of thoracic cancer
    • Mah D et al 2000 Technical aspects of the deep inspiration breath-hold technique in the treatment of thoracic cancer Int. J. Radiat. Oncol. Biol. Phys. 48 1175-85
    • (2000) Int. J. Radiat. Oncol. Biol. Phys. , vol.48 , Issue.4 , pp. 1175-1185
    • Mah, D.1    Al, E.2
  • 16
    • 0023640941 scopus 로고
    • The double-fissure sign: A motion artifact on thin-section CT scans
    • Mayo J R, Muller N L and Henkelman R M 1987 The double-fissure sign: a motion artifact on thin-section CT scans Radiology 165 580-1
    • (1987) Radiology , vol.165 , Issue.2 , pp. 580-581
    • Mayo, J.R.1    Muller, N.L.2    Henkelman, R.M.3
  • 17
    • 3042661990 scopus 로고    scopus 로고
    • Physical performance evaluation of a 256-slice CT-scanner for four-dimensional imaging
    • Mori S et al 2004 Physical performance evaluation of a 256-slice CT-scanner for four-dimensional imaging Med. Phys. 31 1348-56
    • (2004) Med. Phys. , vol.31 , Issue.6 , pp. 1348-1356
    • Mori, S.1    Al, E.2
  • 18
    • 13244255249 scopus 로고    scopus 로고
    • Volumetric cine imaging for cardiovascular circulation using prototype 256-detector row computed tomography scanner (4-dimensional computed tomography) a preliminary study with a porcine model
    • Mori S et al 2005a Volumetric cine imaging for cardiovascular circulation using prototype 256-detector row computed tomography scanner (4-dimensional computed tomography) a preliminary study with a porcine model J. Comput. Assist. Tomogr. 29 26-30
    • (2005) J. Comput. Assist. Tomogr. , vol.29 , Issue.1 , pp. 26-30
    • Mori, S.1    Al, E.2
  • 19
    • 24644502799 scopus 로고    scopus 로고
    • Clinical potentials for dynamic contrast-enhanced hepatic volumetric cine imaging with the prototype 256-MDCT scanner
    • Mori S et al 2005b Clinical potentials for dynamic contrast-enhanced hepatic volumetric cine imaging with the prototype 256-MDCT scanner Am. J. Roentgenol. 185 253-6
    • (2005) Am. J. Roentgenol. , vol.185 , pp. 253-256
    • Mori, S.1    Al, E.2
  • 20
    • 33644663805 scopus 로고    scopus 로고
    • Volumetric perfusion CT using prototype 256-detector row computed tomography scanner: Preliminary study with healthy porcine model
    • Mori S et al 2005c Volumetric perfusion CT using prototype 256-detector row computed tomography scanner: preliminary study with healthy porcine model Am. J. Neuroradiol.
    • (2005) Am. J. Neuroradiol.
    • Mori, S.1    Al, E.2
  • 21
    • 0034255586 scopus 로고    scopus 로고
    • The deep inspiration breath-hold technique in the treatment of inoperable nonsmall-cell lung cancer
    • Rosenzweig K E et al 2000 The deep inspiration breath-hold technique in the treatment of inoperable nonsmall-cell lung cancer Int. J. Radiat. Oncol. Biol. Phys. 48 81-7
    • (2000) Int. J. Radiat. Oncol. Biol. Phys. , vol.48 , Issue.1 , pp. 81-87
    • Rosenzweig, K.E.1    Al, E.2
  • 22
    • 0034876879 scopus 로고    scopus 로고
    • Large area 2-dimensional detector for real-time 3-dimensional CT (4D CT)
    • Saito Y et al 2001 Large area 2-dimensional detector for real-time 3-dimensional CT (4D CT) Proc. SPIE 4320 775-82
    • (2001) Proc. SPIE , vol.4320 , pp. 775-782
    • Saito, Y.1    Al, E.2
  • 23
    • 0034654424 scopus 로고    scopus 로고
    • Impact of respiratory movement on the computed tomographic images of small lung tumors in three-dimensional (3D) radiotherapy
    • Shimizu S et al 2000 Impact of respiratory movement on the computed tomographic images of small lung tumors in three-dimensional (3D) radiotherapy Int. J. Radiat. Oncol. Biol. Phys. 46 1127-33
    • (2000) Int. J. Radiat. Oncol. Biol. Phys. , vol.46 , Issue.5 , pp. 1127-1133
    • Shimizu, S.1    Al, E.2
  • 24
    • 0007622263 scopus 로고    scopus 로고
    • Respiratory gated radiotherapy
    • Sontag M 1996 Respiratory gated radiotherapy Med. Phys. 26 1112
    • (1996) Med. Phys. , vol.26 , pp. 1112
    • Sontag, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.