메뉴 건너뛰기




Volumn 61, Issue 5, 2004, Pages 845-848

Dosimetric comparison at FiR 1 using microdosimetry, ionisation chambers and computer simulation

Author keywords

BNCT; Epithermal neutron beam; Microdosimetry

Indexed keywords

COMPUTER SIMULATION; GAMMA RAYS; IONIZATION CHAMBERS; TISSUE;

EID: 4143090550     PISSN: 09698043     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.apradiso.2004.05.040     Document Type: Conference Paper
Times cited : (2)

References (15)
  • 2
    • 0030994777 scopus 로고    scopus 로고
    • W values in propane-based tissue-equivalent gas
    • Bronic I.K. W values in propane-based tissue-equivalent gas. Rad. Prot. Dos. 70:1997;33-36
    • (1997) Rad. Prot. Dos. , vol.70 , pp. 33-36
    • Bronic, I.K.1
  • 3
    • 0034806317 scopus 로고    scopus 로고
    • Miniature tissue-equivalent proportional counters for BNCT and BNCEFNT dosimetry
    • Burmeister J., Kota C., Maughan R.L., Waker A. Miniature tissue-equivalent proportional counters for BNCT and BNCEFNT dosimetry. Med. Phys. 28:2001;1911-1925
    • (2001) Med. Phys. , vol.28 , pp. 1911-1925
    • Burmeister, J.1    Kota, C.2    Maughan, R.L.3    Waker, A.4
  • 5
    • 0020213666 scopus 로고
    • Photon mass attenuation and energy-absorption coefficients from 1 keV to 20 MeV
    • Hubbell J.H. Photon mass attenuation and energy-absorption coefficients from 1. keV to 20 MeV Int. J. Appl. Radiat. Isot. 33:1982;1269-1290
    • (1982) Int. J. Appl. Radiat. Isot. , vol.33 , pp. 1269-1290
    • Hubbell, J.H.1
  • 6
    • 0003639052 scopus 로고
    • Determination of absorbed dose in a patient irradiated by beams of X- or gamma rays in radiotherapy procedures
    • International Commission for Radiation Units and Measurement, 1976. Determination of absorbed dose in a patient irradiated by beams of X- or gamma rays in radiotherapy procedures. ICRU Report 24.
    • (1976) ICRU Report 24
  • 7
    • 0003982205 scopus 로고
    • Stopping powers for electrons and positrons
    • International Commission for Radiation Units and Measurement, 1984. Stopping powers for electrons and positrons. ICRU Report 37.
    • (1984) ICRU Report 37
  • 8
    • 0003697463 scopus 로고
    • Stopping powers and ranges for protons and alpha particles
    • International Commission for Radiation Units and Measurement, 1994. Stopping powers and ranges for protons and alpha particles. ICRU Report 49.
    • (1994) ICRU Report 49
  • 9
    • 0034122435 scopus 로고    scopus 로고
    • The use of low-pressure tissue equivalent proportional counters for the dosimetry of neutron beams used in BNCT and BNCEFT
    • Kota C., Maughan R., Tattam D., Beynon D. The use of low-pressure tissue equivalent proportional counters for the dosimetry of neutron beams used in BNCT and BNCEFT. Med. Phys. 27:2000;535-548
    • (2000) Med. Phys. , vol.27 , pp. 535-548
    • Kota, C.1    Maughan, R.2    Tattam, D.3    Beynon, D.4
  • 12
    • 0028938179 scopus 로고
    • Determination of dose components in phantoms irradiated with an epithermal neutron beam for boron neutron capture therapy
    • Raaijmakers M.W., Konijnenberg H.W., Mijnheer B. Determination of dose components in phantoms irradiated with an epithermal neutron beam for boron neutron capture therapy. Med. Phys. 22:1994;321-329
    • (1994) Med. Phys. , vol.22 , pp. 321-329
    • Raaijmakers, M.W.1    Konijnenberg, H.W.2    Mijnheer, B.3
  • 13
    • 0028053902 scopus 로고
    • Mixed field dosimetry of epithermal neutron beams for boron neutron capture therapy at the MITR-II research reactor
    • Rogus R.D, Harling O.K., Yanch J.C. Mixed field dosimetry of epithermal neutron beams for boron neutron capture therapy at the MITR-II research reactor. Med. Phys. 21(10):1994;1611-1625
    • (1994) Med. Phys. , vol.21 , Issue.10 , pp. 1611-1625
    • Rogus, R.D.1    Harling, O.K.2    Yanch, J.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.