메뉴 건너뛰기




Volumn 30, Issue 8, 2003, Pages 2131-2139

Microdosimetric intercomparison of BNCT beams at BNL and MIT

Author keywords

BNCT; Epithermal neutrons; Microdosimetry

Indexed keywords

PATIENT TREATMENT; RESEARCH REACTORS;

EID: 0041888203     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1589612     Document Type: Article
Times cited : (8)

References (28)
  • 1
    • 0034806317 scopus 로고    scopus 로고
    • Miniature tissue-equivalent proportional counters for BNCT and BNCEFNT dosimetry
    • J. Burmeister, C. Kota, A. J. Waker, and R. L. Maughan, "Miniature tissue-equivalent proportional counters for BNCT and BNCEFNT dosimetry," Med. Phys. 28, 1911-1925 (2001).
    • (2001) Med. Phys. , vol.28 , pp. 1911-1925
    • Burmeister, J.1    Kota, C.2    Waker, A.J.3    Maughan, R.L.4
  • 2
    • 0037150007 scopus 로고    scopus 로고
    • Characterization of miniature tissue-equivalent proportional counters for neutron radiotherapy applications
    • J. Burmeister, C. Kota, R. L. Maughan, and A. J. Waker, "Characterization of miniature tissue-equivalent proportional counters for neutron radiotherapy applications," Phys. Med. Biol. 47, 1633-1645 (2002).
    • (2002) Phys. Med. Biol. , vol.47 , pp. 1633-1645
    • Burmeister, J.1    Kota, C.2    Maughan, R.L.3    Waker, A.J.4
  • 4
    • 0028053902 scopus 로고
    • Mixed field dosimetry of epithermal neutron beams for boron neutron capture therapy at the MITR-II research reactor
    • R. D. Rogus, O. K. Harling, and J. C. Yanch, "Mixed field dosimetry of epithermal neutron beams for boron neutron capture therapy at the MITR-II research reactor," Med. Phys. 21, 1611-1625 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 1611-1625
    • Rogus, R.D.1    Harling, O.K.2    Yanch, J.C.3
  • 5
    • 0028938179 scopus 로고
    • Determination of dose components in phantoms irradiated with an epithermal neutron beam for boron neutron capture therapy
    • C. P. J. Raaijmakers, M. W. Konijnenberg, H. W. Verhagen, and B. J. Mijnheer, "Determination of dose components in phantoms irradiated with an epithermal neutron beam for boron neutron capture therapy," Med. Phys. 22, 321-329 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 321-329
    • Raaijmakers, C.P.J.1    Konijnenberg, M.W.2    Verhagen, H.W.3    Mijnheer, B.J.4
  • 6
    • 0038361946 scopus 로고    scopus 로고
    • Dosimetry for BNCT in theory and practice
    • edited by B. Larsson, J. Crawford, and R. Weinreich (Elsevier, Amsterdam)
    • P. Watkins, R. L. Moss, F. Stecher-Rasmussen, and W. Voorbraak, "Dosimetry for BNCT in theory and practice," in Advances in Neutron Capture Therapy, edited by B. Larsson, J. Crawford, and R. Weinreich (Elsevier, Amsterdam, 1997), pp. 141-146.
    • (1997) Advances in Neutron Capture Therapy , pp. 141-146
    • Watkins, P.1    Moss, R.L.2    Stecher-Rasmussen, F.3    Voorbraak, W.4
  • 7
    • 0042412015 scopus 로고    scopus 로고
    • International dosimetry exchange: A status report
    • edited by W. Sauerwein, R. Moss, and A. Wittig (Monduzzi, Bologna)
    • O. K. Harling et al., "International dosimetry exchange: A status report," in Research and Development in Neutron Capture Therapy, edited by W. Sauerwein, R. Moss, and A. Wittig (Monduzzi, Bologna, 2002), pp. 333-339.
    • (2002) Research and Development in Neutron Capture Therapy , pp. 333-339
    • Harling, O.K.1
  • 10
    • 0026851029 scopus 로고
    • Spectral characterization of the epithermal neutron beam at the Brookhaven Medical Research Reactor
    • Y. D. Harker, R. A. Anderl, G. K. Becker, and L. G. Miller, "Spectral characterization of the epithermal neutron beam at the Brookhaven Medical Research Reactor," J. Nucl. Sci. Eng. 110, 355-368 (1992).
    • (1992) J. Nucl. Sci. Eng. , vol.110 , pp. 355-368
    • Harker, Y.D.1    Anderl, R.A.2    Becker, G.K.3    Miller, L.G.4
  • 11
    • 0004847682 scopus 로고
    • Performance of the currently available epithermal neutron beam at the Massachusetts Institute of Technology Reactor (MITR-II)
    • edited by B. J. Allen, D. E. Moore, and B. V. Harrington (Plenum, New York)
    • J. R. Choi, R. G. Zamenhof, J. C. Yanch, R. Rogus, and O. K. Harling, "Performance of the currently available epithermal neutron beam at the Massachusetts Institute of Technology Reactor (MITR-II)," in Progress in Neutron Capture Therapy for Cancer, edited by B. J. Allen, D. E. Moore, and B. V. Harrington (Plenum, New York, 1992), pp. 53-56.
    • (1992) Progress in Neutron Capture Therapy for Cancer , pp. 53-56
    • Choi, J.R.1    Zamenhof, R.G.2    Yanch, J.C.3    Rogus, R.4    Harling, O.K.5
  • 14
    • 33646623084 scopus 로고    scopus 로고
    • Microdosimetry studies at the BMRR and the MITR-II using miniature tissue-equivalent proportional counters
    • edited by M. F. Hawthorne, K. Shelly, and R. J. Wiersema (Plenum, New York)
    • J. Burmeister, C. Kota, R. L. Maughan, K. Riley, O. Harling, L. Wielopolski, R. Ma, and J. Coderre, "Microdosimetry studies at the BMRR and the MITR-II using miniature tissue-equivalent proportional counters," in Frontiers in Neutron Capture Therapy, edited by M. F. Hawthorne, K. Shelly, and R. J. Wiersema (Plenum, New York, 2001), Vol. 1, pp. 581-586.
    • (2001) Frontiers in Neutron Capture Therapy , vol.1 , pp. 581-586
    • Burmeister, J.1    Kota, C.2    Maughan, R.L.3    Riley, K.4    Harling, O.5    Wielopolski, L.6    Ma, R.7    Coderre, J.8
  • 18
    • 0034122435 scopus 로고    scopus 로고
    • Use of low pressure tissue equivalent proportional counters for dosimetry in BNCT and BNCEFNT
    • C. Kota and R. L. Maughan, "Use of low pressure tissue equivalent proportional counters for dosimetry in BNCT and BNCEFNT," Med. Phys. 27. 535-548 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 535-548
    • Kota, C.1    Maughan, R.L.2
  • 19
    • 0030442606 scopus 로고    scopus 로고
    • An improved neutron collimator for brain tumor irradiations in clinical boron neutron capture therapy
    • H. B. Liu, D. D. Greenberg, J. Capala, and F. Wheeler, "An improved neutron collimator for brain tumor irradiations in clinical boron neutron capture therapy," Med. Phys. 23, 2051-2060 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 2051-2060
    • Liu, H.B.1    Greenberg, D.D.2    Capala, J.3    Wheeler, F.4
  • 20
    • 0025030139 scopus 로고
    • Biological weighting function for RBE specification of neutron therapy beams. Intercomparison of 9 European centres
    • edited by J. Booz, J. A. Dennis, and H. G. Menzel, Radiat. Prot. Dosim.
    • P. Pihet, H. G. Menzel, R. Schmidt, M. Beauduin, and A. Wambersie, "Biological weighting function for RBE specification of neutron therapy beams. Intercomparison of 9 European centres," in Proceedings of the 10th Symposium On Microdosimetry, edited by J. Booz, J. A. Dennis, and H. G. Menzel, Radiat. Prot. Dosim. 31, 437-442 (1990).
    • (1990) Proceedings of the 10th Symposium On Microdosimetry , vol.31 , pp. 437-442
    • Pihet, P.1    Menzel, H.G.2    Schmidt, R.3    Beauduin, M.4    Wambersie, A.5
  • 21
    • 0028313985 scopus 로고
    • Radiobiological effectiveness of radiation beams with broad LET spectra: Microdosimetric analysis using biological weighting functions
    • T. Loncol, V. Cosgrove, J. M. Denis, J. Gueulette, A. Mazal, H. G. Menzel, P. Pihet, and R. Sabattier, "Radiobiological effectiveness of radiation beams with broad LET spectra: microdosimetric analysis using biological weighting functions," Radiat. Prot. Dosim. 52, 347-352 (1994).
    • (1994) Radiat. Prot. Dosim. , vol.52 , pp. 347-352
    • Loncol, T.1    Cosgrove, V.2    Denis, J.M.3    Gueulette, J.4    Mazal, A.5    Menzel, H.G.6    Pihet, P.7    Sabattier, R.8
  • 24
    • 0034988460 scopus 로고    scopus 로고
    • Biological dosimetry for epithermal neutron beams
    • S. M. White, K. D. Held, M. R. Palmer, and J. C. Yanch, "Biological dosimetry for epithermal neutron beams," Radiat. Res. 155, 778-784 (2001).
    • (2001) Radiat. Res. , vol.155 , pp. 778-784
    • White, S.M.1    Held, K.D.2    Palmer, M.R.3    Yanch, J.C.4
  • 25
    • 0018933433 scopus 로고
    • Kerma factors for neutron energies below 30 MeV
    • R. S. Caswell, J. J. Coyne, and M. L. Randolph, "Kerma factors for neutron energies below 30 MeV," Radiat. Res. 83, 217-254 (1980).
    • (1980) Radiat. Res. , vol.83 , pp. 217-254
    • Caswell, R.S.1    Coyne, J.J.2    Randolph, M.L.3
  • 28
    • 0032742682 scopus 로고    scopus 로고
    • Paired Mg and Mg(B) ionization chambers for measurement of boron neutron capture dose in neutron beams
    • J. Burmeister, C. Kota, R. L. Maughan, and M. Yudelev, "Paired Mg and Mg(B) ionization chambers for measurement of boron neutron capture dose in neutron beams," Med. Phys. 26, 2482-2487 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 2482-2487
    • Burmeister, J.1    Kota, C.2    Maughan, R.L.3    Yudelev, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.