Volumn 33, Issue 6, 2008, Pages 597-606

Wear of an experimental metal-on-metal artificial disc for the lumbar spine

Author keywords

Artificial disc; Biomechanics; Lumbar spine; Metal onmetal; Wear simulation

Indexed keywords

CARBON;

EID: 41349118316     PISSN: 03622436     EISSN: 15281159     Source Type: Journal    
DOI: 10.1097/BRS.0b013e318166aaa4     Document Type: Article
Times cited : (23)

References (65)
  • 1
    • 8644275534 scopus 로고    scopus 로고
    • Design and evaluation of the FlexiCore metal-on-metal intervertebral disc prosthesis
    • Valdevit A, Errico TJ. Design and evaluation of the FlexiCore metal-on-metal intervertebral disc prosthesis. Spine J 2004;4:276S-288S.
    • (2004) Spine J , vol.4
    • Valdevit, A.1    Errico, T.J.2
  • 2
    • 8644227784 scopus 로고    scopus 로고
    • Design rationale and biomechanics of Maverick total disc arthroplasty with early clinical results
    • Mathews HH, Lehuec JC, Friesem T, et al. Design rationale and biomechanics of Maverick total disc arthroplasty with early clinical results. Spine J 2004;4:268S-275S.
    • (2004) Spine J , vol.4
    • Mathews, H.H.1    Lehuec, J.C.2    Friesem, T.3
  • 3
    • 0035736451 scopus 로고    scopus 로고
    • The wear of metal-on-metal total hip prostheses measured in a hip simulator
    • Scholes SC, Green SM, Unsworth A. The wear of metal-on-metal total hip prostheses measured in a hip simulator. Proc Inst Mech Eng [H] 2001;215:523-30.
    • (2001) Proc Inst Mech Eng [H] , vol.215 , pp. 523-530
    • Scholes, S.C.1    Green, S.M.2    Unsworth, A.3
  • 4
    • 0032837830 scopus 로고    scopus 로고
    • Quantitative analysis of the wear and wear debris from low and high carbon content cobalt chrome alloys used in metal on metal total hip replacements
    • Tipper JL, Firkins PJ, Ingham E, et al. Quantitative analysis of the wear and wear debris from low and high carbon content cobalt chrome alloys used in metal on metal total hip replacements. J Mater Sci Mater Med 1999;10:353-62.
    • (1999) J Mater Sci Mater Med , vol.10 , pp. 353-362
    • Tipper, J.L.1    Firkins, P.J.2    Ingham, E.3
  • 5
    • 0016091567 scopus 로고
    • A study of the wear of some materials in connection with total hip replacement
    • Dumbleton JH, Shen C. A study of the wear of some materials in connection with total hip replacement. Wear 1974;29:163-71.
    • (1974) Wear , vol.29 , pp. 163-171
    • Dumbleton, J.H.1    Shen, C.2
  • 6
    • 0033378263 scopus 로고    scopus 로고
    • Metal-on-metal bearing in hip prosthesis generates 100-fold less wear debris than metal-on-polyethylene
    • Anissian HL, Stark A, Gustafson A, et al. Metal-on-metal bearing in hip prosthesis generates 100-fold less wear debris than metal-on-polyethylene. Acta Orthop Scand 1999;70:578-82.
    • (1999) Acta Orthop Scand , vol.70 , pp. 578-582
    • Anissian, H.L.1    Stark, A.2    Gustafson, A.3
  • 7
    • 0033641059 scopus 로고    scopus 로고
    • Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements
    • Clarke IC, Good V, Williams P, et al. Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements. Proc Inst Mech Eng [H] 2000;214:331-47.
    • (2000) Proc Inst Mech Eng [H] , vol.214 , pp. 331-347
    • Clarke, I.C.1    Good, V.2    Williams, P.3
  • 8
    • 0033630259 scopus 로고    scopus 로고
    • A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements
    • Goldsmith AA, Dowson D, Isaac GH, et al. A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements. Proc Inst Mech Eng [H] 2000;214:39-47.
    • (2000) Proc Inst Mech Eng [H] , vol.214 , pp. 39-47
    • Goldsmith, A.A.1    Dowson, D.2    Isaac, G.H.3
  • 10
    • 19944381551 scopus 로고    scopus 로고
    • Hip simulator wear comparison of metal-on-metal, ceramic-on-ceramic and crosslinked UHMWPE bearings
    • Essner A, Sutton K, Wang A. Hip simulator wear comparison of metal-on-metal, ceramic-on-ceramic and crosslinked UHMWPE bearings. Wear 2005;259:992-5.
    • (2005) Wear , vol.259 , pp. 992-995
    • Essner, A.1    Sutton, K.2    Wang, A.3
  • 11
    • 27744560273 scopus 로고    scopus 로고
    • A 12-station anatomic hip joint simulator
    • Saikko V. A 12-station anatomic hip joint simulator. Proc Inst Mech Eng [H] 2005;219:437-48.
    • (2005) Proc Inst Mech Eng [H] , vol.219 , pp. 437-448
    • Saikko, V.1
  • 12
    • 0030454623 scopus 로고    scopus 로고
    • Engineering issues and wear performance of metal on metal hip implants
    • Chan FW, Bobyn JD, Medley JB, et al. Engineering issues and wear performance of metal on metal hip implants. Clin Orthop Relat Res 1996;96-107.
    • (1996) Clin Orthop Relat Res , pp. 96-107
    • Chan, F.W.1    Bobyn, J.D.2    Medley, J.B.3
  • 13
    • 0033256670 scopus 로고    scopus 로고
    • The Otto Aufranc Award. Wear and lubrication of metal-on-metal hip implants
    • Chan FW, Bobyn JD, Medley JB, et al. The Otto Aufranc Award. Wear and lubrication of metal-on-metal hip implants. Clin Orthop Relat Res 1999;10-24.
    • (1999) Clin Orthop Relat Res , pp. 10-24
    • Chan, F.W.1    Bobyn, J.D.2    Medley, J.B.3
  • 14
    • 9644287859 scopus 로고    scopus 로고
    • A hip joint simulator study of the performance of metal-on-metal joints: Part I: the role of materials
    • Dowson D, Hardaker C, Flett M, et al. A hip joint simulator study of the performance of metal-on-metal joints: Part I: the role of materials. J Arthroplasty 2004;19:118-23.
    • (2004) J Arthroplasty , vol.19 , pp. 118-123
    • Dowson, D.1    Hardaker, C.2    Flett, M.3
  • 15
    • 0035045395 scopus 로고    scopus 로고
    • Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator
    • Firkins PJ, Tipper JL, Saadatzadeh MR, et al. Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator. Biomed Mater Eng 2001;11:143-57.
    • (2001) Biomed Mater Eng , vol.11 , pp. 143-157
    • Firkins, P.J.1    Tipper, J.L.2    Saadatzadeh, M.R.3
  • 16
    • 17544388139 scopus 로고    scopus 로고
    • Surface characterization of metal-on-metal hip implants tested in a hip simulator
    • Wang A, Yue S, Bobyn JD, et al. Surface characterization of metal-on-metal hip implants tested in a hip simulator. Wear 1999;225-229:708-15.
    • (1999) Wear
    • Wang, A.1    Yue, S.2    Bobyn, J.D.3
  • 17
    • 9644273921 scopus 로고    scopus 로고
    • A hip joint simulator study of the performance of metal-on-metal joints: Part II: design
    • Dowson D, Hardaker C, Flett M, et al. A hip joint simulator study of the performance of metal-on-metal joints: Part II: design. J Arthroplasty 2004; 19:124-30.
    • (2004) J Arthroplasty , vol.19 , pp. 124-130
    • Dowson, D.1    Hardaker, C.2    Flett, M.3
  • 18
    • 0029831455 scopus 로고    scopus 로고
    • In vivo wear of three types of metal on metal hip prostheses during two decades of use
    • McKellop H, Park SH, Chiesa R, et al. In vivo wear of three types of metal on metal hip prostheses during two decades of use. Clin Orthop Relat Res 1996;S128-S140.
    • (1996) Clin Orthop Relat Res
    • McKellop, H.1    Park, S.H.2    Chiesa, R.3
  • 19
    • 0030210397 scopus 로고    scopus 로고
    • Comparison of alloys and designs in a hip simulator study of metal on metal implants
    • Medley JB, Chan FW, Krygier JJ, et al. Comparison of alloys and designs in a hip simulator study of metal on metal implants. Clin Orthop Relat Res 1996;S148-S159.
    • (1996) Clin Orthop Relat Res
    • Medley, J.B.1    Chan, F.W.2    Krygier, J.J.3
  • 20
    • 0035229408 scopus 로고    scopus 로고
    • The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacements
    • Smith SL, Dowson D, Goldsmith AA. The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacements. Proc Inst Mech Eng [H] 2001;215:161-70.
    • (2001) Proc Inst Mech Eng [H] , vol.215 , pp. 161-170
    • Smith, S.L.1    Dowson, D.2    Goldsmith, A.A.3
  • 21
    • 18144367731 scopus 로고    scopus 로고
    • Analysis of a retrieved polyethylene total disc replacement component
    • Kurtz SM, Peloza J, Siskey R, et al. Analysis of a retrieved polyethylene total disc replacement component. Spine J 2005;5:344-50.
    • (2005) Spine J , vol.5 , pp. 344-350
    • Kurtz, S.M.1    Peloza, J.2    Siskey, R.3
  • 22
    • 21544465887 scopus 로고    scopus 로고
    • Revision of a Charite artificial disc 9.5 years in vivo to a new Charite artificial disc: Case report and explant analysis
    • Thierry D. Revision of a Charite artificial disc 9.5 years in vivo to a new Charite artificial disc: case report and explant analysis. Eur Spine J 2005.
    • (2005) Eur Spine J
    • Thierry, D.1
  • 23
    • 41349103536 scopus 로고    scopus 로고
    • Kurtz SM, van Ooij A, John P, et al. Central core and rim damage in retrieved polyethylene total disc replacement components. Proceedings of the NASS 20th Annual Meeting. Spine J 2005;5:1S-189S.
    • Kurtz SM, van Ooij A, John P, et al. Central core and rim damage in retrieved polyethylene total disc replacement components. Proceedings of the NASS 20th Annual Meeting. Spine J 2005;5:1S-189S.
  • 24
    • 41349090700 scopus 로고    scopus 로고
    • Retrieval analysis of short-term implanted Maverick total disc arthroplasty. Proceedings of the NASS 20th Annual Meeting
    • Kurtz SM, McCombe P, Ciccarelli L, et al. Retrieval analysis of short-term implanted Maverick total disc arthroplasty. Proceedings of the NASS 20th Annual Meeting. Spine J 2005;5:1S-189S.
    • (2005) Spine J , vol.5
    • Kurtz, S.M.1    McCombe, P.2    Ciccarelli, L.3
  • 26
    • 41349115383 scopus 로고    scopus 로고
    • Wear characterization of the Charite Artificial Disc using ASTM guidelines. Proceedings of the NASS 20th Annual Meeting
    • Serhan HA, Dooris AP, Ares PJ, et al. Wear characterization of the Charite Artificial Disc using ASTM guidelines. Proceedings of the NASS 20th Annual Meeting. Spine J 2005;5:1S-189S.
    • (2005) Spine J , vol.5
    • Serhan, H.A.1    Dooris, A.P.2    Ares, P.J.3
  • 28
    • 0037411471 scopus 로고    scopus 로고
    • Macrophage response to cross-linked and conventional UHMWPE
    • Sethi RK, Neavyn MJ, Rubash HE, et al. Macrophage response to cross-linked and conventional UHMWPE. Biomaterials 2003;24:2561-73.
    • (2003) Biomaterials , vol.24 , pp. 2561-2573
    • Sethi, R.K.1    Neavyn, M.J.2    Rubash, H.E.3
  • 29
    • 0034012406 scopus 로고    scopus 로고
    • Apoptosis in peri-implant tissue
    • Stea S, Visentin M, Granchi D, et al. Apoptosis in peri-implant tissue. Biomaterials 2000;21:1393-8.
    • (2000) Biomaterials , vol.21 , pp. 1393-1398
    • Stea, S.1    Visentin, M.2    Granchi, D.3
  • 30
    • 0030852534 scopus 로고    scopus 로고
    • Effects of particles on fibroblast proliferation and bone resorption in vitro
    • Shanbhag AS, Jacobs JJ, Black J, et al. Effects of particles on fibroblast proliferation and bone resorption in vitro. Clin Orthop Relat Res 1997;205-17.
    • (1997) Clin Orthop Relat Res , pp. 205-217
    • Shanbhag, A.S.1    Jacobs, J.J.2    Black, J.3
  • 31
    • 0347505008 scopus 로고    scopus 로고
    • Ion release and chromosomal damage from total hip prostheses with metal-on-metal articulation
    • Masse A, Bosetti M, Buratti C, et al. Ion release and chromosomal damage from total hip prostheses with metal-on-metal articulation. J Biomed Mater Res B Appl Biomater 2003;67:750-7.
    • (2003) J Biomed Mater Res B Appl Biomater , vol.67 , pp. 750-757
    • Masse, A.1    Bosetti, M.2    Buratti, C.3
  • 32
    • 18244384199 scopus 로고    scopus 로고
    • Serum levels of cobalt and chromium in patients with Sikomet metal-metal total hip replacements
    • Milosev I, Pisot V, Campbell P. Serum levels of cobalt and chromium in patients with Sikomet metal-metal total hip replacements. J Orthop Res 2005;23:526-35.
    • (2005) J Orthop Res , vol.23 , pp. 526-535
    • Milosev, I.1    Pisot, V.2    Campbell, P.3
  • 33
    • 18944372870 scopus 로고    scopus 로고
    • Metal ion levels after metal-on-metal proximal femoral replacements: A 30-year follow-up
    • Dunstan E, Sanghrajka AP, Tilley S, et al. Metal ion levels after metal-on-metal proximal femoral replacements: a 30-year follow-up. J Bone Joint Surg Br 2005;87:628-31.
    • (2005) J Bone Joint Surg Br , vol.87 , pp. 628-631
    • Dunstan, E.1    Sanghrajka, A.P.2    Tilley, S.3
  • 34
    • 0019128573 scopus 로고
    • Metal ion release after total hip replacement
    • Dobbs HS, Minski MJ. Metal ion release after total hip replacement. Biomaterials 1980;1:193-8.
    • (1980) Biomaterials , vol.1 , pp. 193-198
    • Dobbs, H.S.1    Minski, M.J.2
  • 35
    • 41349121249 scopus 로고    scopus 로고
    • ASTM. F1714-96(2002) Standard guide for gravimetric wear assessment of prosthetic hip-designs in simulator devices. ASTM International Standards on Disc 2003;13.01.
    • ASTM. F1714-96(2002) Standard guide for gravimetric wear assessment of prosthetic hip-designs in simulator devices. ASTM International Standards on Disc 2003;13.01.
  • 36
    • 0042126909 scopus 로고    scopus 로고
    • The effect of frictional heating and forced cooling on the serum lubricant and wear of UHMW polyethylene cups against cobalt-chromium and zirconia balls
    • Liao YS, McKellop H, Lu Z, et al. The effect of frictional heating and forced cooling on the serum lubricant and wear of UHMW polyethylene cups against cobalt-chromium and zirconia balls. Biomaterials 2003;24:3047-59.
    • (2003) Biomaterials , vol.24 , pp. 3047-3059
    • Liao, Y.S.1    McKellop, H.2    Lu, Z.3
  • 37
    • 0033104976 scopus 로고    scopus 로고
    • Low back three-dimensional joint forces, kinematics, and kinetics during walking
    • Callaghan JP, Patla AE, McGill SM. Low back three-dimensional joint forces, kinematics, and kinetics during walking. Clin Biomech (Bristol, Avon) 1999;14:203-16.
    • (1999) Clin Biomech (Bristol, Avon) , vol.14 , pp. 203-216
    • Callaghan, J.P.1    Patla, A.E.2    McGill, S.M.3
  • 38
    • 0021345986 scopus 로고
    • Compressive loads in the lumbar vertebral column during normal level walking
    • Cappozzo A. Compressive loads in the lumbar vertebral column during normal level walking. J Orthop Res 1984;1:292-301.
    • (1984) J Orthop Res , vol.1 , pp. 292-301
    • Cappozzo, A.1
  • 39
    • 0028450229 scopus 로고
    • A comparison of lumbosacral loads during static and dynamic activities
    • Khoo BC, Goh JC, Lee JM, et al. A comparison of lumbosacral loads during static and dynamic activities. Australas Phys Eng Sci Med 1994;17:55-63.
    • (1994) Australas Phys Eng Sci Med , vol.17 , pp. 55-63
    • Khoo, B.C.1    Goh, J.C.2    Lee, J.M.3
  • 40
    • 0020964221 scopus 로고
    • The forces and couples in the human trunk during level walking
    • Cappozzo A. The forces and couples in the human trunk during level walking. J Biomech 1983;16:265-77.
    • (1983) J Biomech , vol.16 , pp. 265-277
    • Cappozzo, A.1
  • 41
    • 0024673529 scopus 로고
    • Loads on the lumbar trunk during level walking
    • Cromwell R, Schultz AB, Beck R, et al. Loads on the lumbar trunk during level walking. J Orthop Res 1989;7:371-7.
    • (1989) J Orthop Res , vol.7 , pp. 371-377
    • Cromwell, R.1    Schultz, A.B.2    Beck, R.3
  • 42
    • 0031781726 scopus 로고    scopus 로고
    • Effects of varying backpack loads on peak forces in the lumbosacral spine during walking
    • Goh JH, Thambyah A, Bose K. Effects of varying backpack loads on peak forces in the lumbosacral spine during walking. Clin Biomech (Bristol, Avon) 1998;13:S26-S31.
    • (1998) Clin Biomech (Bristol, Avon) , vol.13
    • Goh, J.H.1    Thambyah, A.2    Bose, K.3
  • 43
    • 0028821382 scopus 로고
    • A biomechanical model to determine lumbosacral loads during single stance phase in normal gait
    • Khoo BC, Goh JC, Bose K. A biomechanical model to determine lumbosacral loads during single stance phase in normal gait. Med Eng Phys 1995;17:27-35.
    • (1995) Med Eng Phys , vol.17 , pp. 27-35
    • Khoo, B.C.1    Goh, J.C.2    Bose, K.3
  • 44
    • 0043065573 scopus 로고    scopus 로고
    • Quantification of the effect of cross-path motion on the wear rate of ultra-high molecular weight polyethylene
    • Turell M, Wang A, Bellare A. Quantification of the effect of cross-path motion on the wear rate of ultra-high molecular weight polyethylene. Wear 2003;255:1034-9.
    • (2003) Wear , vol.255 , pp. 1034-1039
    • Turell, M.1    Wang, A.2    Bellare, A.3
  • 45
    • 41349098903 scopus 로고    scopus 로고
    • ASTM. F2025-00 Standard practice for gravimetric measurement of polymeric components for wear assessment. ASTM International Standards on Disc 2003;13.01.
    • ASTM. F2025-00 Standard practice for gravimetric measurement of polymeric components for wear assessment. ASTM International Standards on Disc 2003;13.01.
  • 46
    • 0035065646 scopus 로고    scopus 로고
    • Influence of simulator kinematics on the wear of metal-on-metal hip prostheses
    • Firkins PJ, Tipper JL, Ingham E, et al. Influence of simulator kinematics on the wear of metal-on-metal hip prostheses. Proc Inst Mech Eng [H] 2001;215:119-21.
    • (2001) Proc Inst Mech Eng [H] , vol.215 , pp. 119-121
    • Firkins, P.J.1    Tipper, J.L.2    Ingham, E.3
  • 48
    • 0029833296 scopus 로고    scopus 로고
    • Systems view of optimizing metal on metal bearings
    • Schey JA. Systems view of optimizing metal on metal bearings. Clin Orthop Relat Res 1996;S115-27.
    • (1996) Clin Orthop Relat Res
    • Schey, J.A.1
  • 49
    • 0034534762 scopus 로고    scopus 로고
    • A frictional study of total hip joint replacements
    • Scholes SC, Unsworth A, Goldsmith AA. A frictional study of total hip joint replacements. Phys Med Biol 2000;45:3721-35.
    • (2000) Phys Med Biol , vol.45 , pp. 3721-3735
    • Scholes, S.C.1    Unsworth, A.2    Goldsmith, A.A.3
  • 50
    • 0034233164 scopus 로고    scopus 로고
    • The effects of material combination and lubricant on the friction of total hip prostheses
    • Scholes SC, Unsworth A, Hall RM, et al. The effects of material combination and lubricant on the friction of total hip prostheses. Wear 2000;241:209-13.
    • (2000) Wear , vol.241 , pp. 209-213
    • Scholes, S.C.1    Unsworth, A.2    Hall, R.M.3
  • 52
    • 0042564752 scopus 로고    scopus 로고
    • Tribochemical reaction on metal-on-metal hip joint bearings: A comparison between in-vitro and in-vivo results
    • Wimmer MA, Sprecher C, Hauert R, et al. Tribochemical reaction on metal-on-metal hip joint bearings: a comparison between in-vitro and in-vivo results. Wear 2003;255:1007-14.
    • (2003) Wear , vol.255 , pp. 1007-1014
    • Wimmer, M.A.1    Sprecher, C.2    Hauert, R.3
  • 54
    • 11044226493 scopus 로고    scopus 로고
    • Subsurface microstructure of metal-on-metal hip joints and its relationship to wear particle generation
    • Buscher R, Tager G, Dudzinski W, et al. Subsurface microstructure of metal-on-metal hip joints and its relationship to wear particle generation. J Biomed Mater Res B Appl Biomater 2005;72:206-14.
    • (2005) J Biomed Mater Res B Appl Biomater , vol.72 , pp. 206-214
    • Buscher, R.1    Tager, G.2    Dudzinski, W.3
  • 55
    • 0015052277 scopus 로고
    • The tribology (friction, lubrication, and wear) of all-metal artificial hip joints
    • Walker PS, Gold BL. The tribology (friction, lubrication, and wear) of all-metal artificial hip joints. Wear 1971;17:285-99.
    • (1971) Wear , vol.17 , pp. 285-299
    • Walker, P.S.1    Gold, B.L.2
  • 56
    • 16244380151 scopus 로고    scopus 로고
    • The long-term wear of retrieved McKee-Farrar metal-on-metal total hip prostheses
    • Howie DW, McCalden RW, Nawana NS, et al. The long-term wear of retrieved McKee-Farrar metal-on-metal total hip prostheses. J Arthroplasty 2005;20:350-7.
    • (2005) J Arthroplasty , vol.20 , pp. 350-357
    • Howie, D.W.1    McCalden, R.W.2    Nawana, N.S.3
  • 57
    • 0035481958 scopus 로고    scopus 로고
    • A hip simulator study on the influence of patient activity level on the wear of crosslinked polyethylene under smooth and roughened femoral conditions
    • Bowsher JG, Shelton JC. A hip simulator study on the influence of patient activity level on the wear of crosslinked polyethylene under smooth and roughened femoral conditions. Wear 2001;250:167-79.
    • (2001) Wear , vol.250 , pp. 167-179
    • Bowsher, J.G.1    Shelton, J.C.2
  • 58
    • 0035869773 scopus 로고    scopus 로고
    • Observations at the articular surface of hip prostheses: An analytical electron microscopy study on wear and corrosion
    • Koerten HK, Onderwater JJM, Koerten EWA, et al. Observations at the articular surface of hip prostheses: an analytical electron microscopy study on wear and corrosion. J Biomed Mater Res 2001;54:591-6.
    • (2001) J Biomed Mater Res , vol.54 , pp. 591-596
    • Koerten, H.K.1    Onderwater, J.J.M.2    Koerten, E.W.A.3
  • 59
    • 0008926164 scopus 로고    scopus 로고
    • Wear morphology of metal-metal-implants: Hip simulator tests compared with clinical retrievals
    • Jacobs JJ, Craig TL, eds, West Conshohocken: ASTM
    • Park S-H, McKellop H. Wear morphology of metal-metal-implants: hip simulator tests compared with clinical retrievals. In Jacobs JJ, Craig TL, eds. Alternative Bearing Surfaces in Total Joint Replacement. West Conshohocken: ASTM, 1998:129-43.
    • (1998) Alternative Bearing Surfaces in Total Joint Replacement , pp. 129-143
    • Park, S.-H.1    McKellop, H.2
  • 60
    • 0029813457 scopus 로고    scopus 로고
    • Cobalt chromium molybdenum metal combination for modular hip prostheses
    • Schmidt M, Weber H, Schon R. Cobalt chromium molybdenum metal combination for modular hip prostheses. Clin Orthop Relat Res 1996;S35-S47.
    • (1996) Clin Orthop Relat Res
    • Schmidt, M.1    Weber, H.2    Schon, R.3
  • 61
    • 9644275369 scopus 로고    scopus 로고
    • Development and validation of a secondgeneration metal-on-metal bearing: Laboratory studies and analysis of retrievals
    • Rieker CB, Schon R, Kottig P. Development and validation of a secondgeneration metal-on-metal bearing: laboratory studies and analysis of retrievals. J Arthroplasty 2004;19:5-11.
    • (2004) J Arthroplasty , vol.19 , pp. 5-11
    • Rieker, C.B.1    Schon, R.2    Kottig, P.3
  • 63
    • 17044413641 scopus 로고    scopus 로고
    • Influence of the clearance on in-vitro tribology of large diameter metal-on-metal articulations pertaining to resurfacing hip implants
    • vii
    • Rieker CB, Schon R, Konrad R, et al. Influence of the clearance on in-vitro tribology of large diameter metal-on-metal articulations pertaining to resurfacing hip implants. Orthop Clin North Am 2005;36:135-42, vii.
    • (2005) Orthop Clin North Am , vol.36 , pp. 135-142
    • Rieker, C.B.1    Schon, R.2    Konrad, R.3
  • 64
    • 5344251924 scopus 로고    scopus 로고
    • The effect of clearance and diameter on debris generation in a metal-on-metal hip
    • Jacobs MA, Schmidt MB, Farrar R. The effect of clearance and diameter on debris generation in a metal-on-metal hip. J Arthroplasty 1998;13.
    • (1998) J Arthroplasty , pp. 13
    • Jacobs, M.A.1    Schmidt, M.B.2    Farrar, R.3
  • 65
    • 33750483040 scopus 로고    scopus 로고
    • Differences in wear mechanisms between main contact areas and stripe wear regions in metal-on-metal hip joints
    • Fischer A, Wimmer MA. Differences in wear mechanisms between main contact areas and stripe wear regions in metal-on-metal hip joints. J Biomech 2006;39:S139.
    • (2006) J Biomech , vol.39
    • Fischer, A.1    Wimmer, M.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.