메뉴 건너뛰기




Volumn 23, Issue 1, 2008, Pages 68-77

Hybrid-state-model-based time-domain identification of synchronous machine parameters from saturated load rejection test records

Author keywords

Cross validation; Identification; Load rejection; Nonlinear hybrid state model; Saturation; Synchronous generator

Indexed keywords

ELECTRIC POWER FACTOR; EQUIVALENT CIRCUITS; IDENTIFICATION (CONTROL SYSTEMS); MATHEMATICAL MODELS; SHORT CIRCUIT CURRENTS; TIME DOMAIN ANALYSIS;

EID: 40849088315     PISSN: 08858969     EISSN: None     Source Type: Journal    
DOI: 10.1109/TEC.2007.914663     Document Type: Article
Times cited : (40)

References (31)
  • 1
    • 13344292739 scopus 로고    scopus 로고
    • Embedded Generation
    • London, U.K, Inst. Electr. Eng. Power Energy
    • N. Jenkins, R. Allan, P. Crossley, D. Kirschen, and G. Strbac, Embedded Generation, Series 31. London, U.K.: Inst. Electr. Eng. Power Energy, 2000.
    • (2000) Series , vol.31
    • Jenkins, N.1    Allan, R.2    Crossley, P.3    Kirschen, D.4    Strbac, G.5
  • 2
    • 40849144694 scopus 로고    scopus 로고
    • J. M. Rodriguez, D. Alvira, D. Beato, R. Iturbe, J. C. Cuadrado, M. Sanz, A. Lombart, and J. R. Wilhelmi, Impact of wind energy generation on the safety of the electrical transmission network, presented at the CIGRE, Paris, France, 2004.
    • J. M. Rodriguez, D. Alvira, D. Beato, R. Iturbe, J. C. Cuadrado, M. Sanz, A. Lombart, and J. R. Wilhelmi, "Impact of wind energy generation on the safety of the electrical transmission network," presented at the CIGRE, Paris, France, 2004.
  • 3
    • 0032686466 scopus 로고    scopus 로고
    • Line-to-line short-circuit test based maximum likelihood estimation of stability model of large generators
    • Jun
    • R. Wamkeue, I. Kamwa, and X. Dai-Do, "Line-to-line short-circuit test based maximum likelihood estimation of stability model of large generators," IEEE Trans. Energy Convers., vol. 14, no. 2, pp. 167-174, Jun. 1999.
    • (1999) IEEE Trans. Energy Convers , vol.14 , Issue.2 , pp. 167-174
    • Wamkeue, R.1    Kamwa, I.2    Dai-Do, X.3
  • 4
    • 2942599725 scopus 로고    scopus 로고
    • Identification of physical parameters of synchronous generator from online measurements
    • Jun
    • M. Karrari and O. P. Malik, "Identification of physical parameters of synchronous generator from online measurements," IEEE Trans. Energy Convers., vol. 19, no. 2, pp. 407-415, Jun. 2004.
    • (2004) IEEE Trans. Energy Convers , vol.19 , Issue.2 , pp. 407-415
    • Karrari, M.1    Malik, O.P.2
  • 5
    • 17444391342 scopus 로고
    • New procedure for the identification of dynamic parameters of synchronous machines by three-phase short-circuit test and extension to other tests
    • C. Maun, "New procedure for the identification of dynamic parameters of synchronous machines by three-phase short-circuit test and extension to other tests," in Proc. ICEM 1984, pp. 121-128.
    • (1984) Proc. ICEM , pp. 121-128
    • Maun, C.1
  • 6
    • 0026851448 scopus 로고
    • Parametric identification of two-port models of synchronous machines
    • P. Guillaume, R. Pntelon, and J. Schoukens, "Parametric identification of two-port models of synchronous machines," in IEEE Trans. Instrum. Meas., vol. 40, no. 2, pp. 233-239, 1992.
    • (1992) IEEE Trans. Instrum. Meas , vol.40 , Issue.2 , pp. 233-239
    • Guillaume, P.1    Pntelon, R.2    Schoukens, J.3
  • 7
    • 0016126190 scopus 로고
    • New approach to determination of synchronous-machine parameters from test
    • G. Shackshaft, "New approach to determination of synchronous-machine parameters from test," in Proc. Inst. Electr. Eng., vol. 121, no. 11, pp. 1385-1392, 1974.
    • (1974) Proc. Inst. Electr. Eng , vol.121 , Issue.11 , pp. 1385-1392
    • Shackshaft, G.1
  • 8
    • 0017634750 scopus 로고
    • Implementation of new approach to the determination of synchronous-machine parameters from test
    • G. Shackshaft, "Implementation of new approach to the determination of synchronous-machine parameters from test," in Proc. Inst. Electr. Eng., vol. 124, no. 12, pp. 1170-1177, 1977.
    • (1977) Proc. Inst. Electr. Eng , vol.124 , Issue.12 , pp. 1170-1177
    • Shackshaft, G.1
  • 9
    • 0017518352 scopus 로고    scopus 로고
    • Derivation of synchronous machine parameters from test
    • Jul.-Aug
    • F. P. de Mello and J. R. Ribeiro, "Derivation of synchronous machine parameters from test," IEEE Trans. Power Appl. Syst., vol. PAS-96, no. 4, pp. 1211-1218, Jul.-Aug. 1997.
    • (1997) IEEE Trans. Power Appl. Syst , vol.PAS-96 , Issue.4 , pp. 1211-1218
    • de Mello, F.P.1    Ribeiro, J.R.2
  • 10
    • 0019531112 scopus 로고
    • Validation of synchronous machine models and derivation of model parameters from tests
    • Feb
    • F. P. de Mello and L. N. Hannett, "Validation of synchronous machine models and derivation of model parameters from tests," IEEE Trans. Power Appl. Syst., vol. PAS-100, no. 2, pp. 662-672, Feb. 1981.
    • (1981) IEEE Trans. Power Appl. Syst , vol.PAS-100 , Issue.2 , pp. 662-672
    • de Mello, F.P.1    Hannett, L.N.2
  • 11
    • 0019530862 scopus 로고
    • Development for measurement of operating parameters of synchronous generator and control systems
    • Feb
    • M. Namba, J. Hsodo, S. Doi, and M. Udo, "Development for measurement of operating parameters of synchronous generator and control systems," IEEE Trans. Power Appl. Syst., vol. PAS-100, no. 2, pp. 618-628, Feb. 1981.
    • (1981) IEEE Trans. Power Appl. Syst , vol.PAS-100 , Issue.2 , pp. 618-628
    • Namba, M.1    Hsodo, J.2    Doi, S.3    Udo, M.4
  • 12
    • 0020116805 scopus 로고
    • Measurements of synchronous-machine parameters under operating conditions
    • Apr
    • T. Sugiyama, T. Nishiwaki, S. Takeda, and S. Abe, "Measurements of synchronous-machine parameters under operating conditions," IEEE Trans. Power Appl. Syst., vol. PAS-101, no. 4, pp. 895-904, Apr. 1982.
    • (1982) IEEE Trans. Power Appl. Syst , vol.PAS-101 , Issue.4 , pp. 895-904
    • Sugiyama, T.1    Nishiwaki, T.2    Takeda, S.3    Abe, S.4
  • 13
    • 40849131908 scopus 로고    scopus 로고
    • Confirmation of test methods for synchronous machine dynamic performance models, EPRI, Rep. EL-5736, 1988.
    • Confirmation of test methods for synchronous machine dynamic performance models, EPRI, Rep. EL-5736, 1988.
  • 14
    • 0025398819 scopus 로고
    • Test and simulations of network dynamic response using SSFR and RTDR derived synchronous machine models
    • Mar
    • P. A. E. Rusche, G. J. Brock, L. N. Hannett, and J. R. Willis, "Test and simulations of network dynamic response using SSFR and RTDR derived synchronous machine models," IEEE Trans. Energy Convers., vol. 5, no. 1, pp. 145-155, Mar. 1990.
    • (1990) IEEE Trans. Energy Convers , vol.5 , Issue.1 , pp. 145-155
    • Rusche, P.A.E.1    Brock, G.J.2    Hannett, L.N.3    Willis, J.R.4
  • 15
    • 0029276513 scopus 로고
    • Practical detailed model for generators
    • Mar
    • K. Hirayama, "Practical detailed model for generators," IEEE Trans. Energy Convers., vol. 10, no. 1, pp. 105-110, Mar. 1995.
    • (1995) IEEE Trans. Energy Convers , vol.10 , Issue.1 , pp. 105-110
    • Hirayama, K.1
  • 16
    • 0036602455 scopus 로고    scopus 로고
    • Synchronous machines parameter identification using load rejection test data
    • Jun
    • E. D. C. Bortoni and J.A. Jardini, "Synchronous machines parameter identification using load rejection test data," IEEE Trans. Energy Convers., vol. 17, no. 2, pp. 242-247, Jun. 2002.
    • (2002) IEEE Trans. Energy Convers , vol.17 , Issue.2 , pp. 242-247
    • Bortoni, E.D.C.1    Jardini, J.A.2
  • 18
    • 40849092028 scopus 로고    scopus 로고
    • Guide for Synchronous Generator Modeling Practices in Stability Analysis
    • Guide for Synchronous Generator Modeling Practices in Stability Analysis, IEEE Standard 1110, 2002.
    • (2002) IEEE Standard , vol.1110
  • 19
    • 33344471437 scopus 로고    scopus 로고
    • A new and efficient approach for analysis of a saturated synchronous generator under the load rejection test
    • May
    • R. Wamkeue, I. Kamwa, F. Baetscher, and J. El Hayek, "A new and efficient approach for analysis of a saturated synchronous generator under the load rejection test," Electr. Power Compon. Syst., vol. 34, no. 5, pp. 539-563, May 2006.
    • (2006) Electr. Power Compon. Syst , vol.34 , Issue.5 , pp. 539-563
    • Wamkeue, R.1    Kamwa, I.2    Baetscher, F.3    El Hayek, J.4
  • 22
    • 0028384758 scopus 로고
    • Three-transferfunction approach for building phenomenological models of synchronous machines
    • Mar
    • I. Kamwa, P. Viarouge, H. Le-Huy, and E. J. Dickinson, "Three-transferfunction approach for building phenomenological models of synchronous machines," in Proc. Inst. Electr. Eng. Gen. Transmiss. Distrib.,Mar. 1994, vol. 141, no. 2, pp. 89-98.
    • (1994) Proc. Inst. Electr. Eng. Gen. Transmiss. Distrib , vol.141 , Issue.2 , pp. 89-98
    • Kamwa, I.1    Viarouge, P.2    Le-Huy, H.3    Dickinson, E.J.4
  • 23
    • 0029517097 scopus 로고
    • A two-factor saturationmodel for synchronous machines with multiple rotor circuits
    • Dec
    • S. A. Tahan and I. Kamwa, "A two-factor saturationmodel for synchronous machines with multiple rotor circuits," IEEE Trans. Energy Convers. vol. 10, no. 4, pp. 609-616, Dec. 1995.
    • (1995) IEEE Trans. Energy Convers , vol.10 , Issue.4 , pp. 609-616
    • Tahan, S.A.1    Kamwa, I.2
  • 24
    • 0027660879 scopus 로고
    • Determination of the parameter representing the cross-magnetizing effect in saturated synchronous machines
    • Sep
    • A. M. El-Serafi and J. Wu, "Determination of the parameter representing the cross-magnetizing effect in saturated synchronous machines," IEEE Trans. Energy Convers., vol. 8, no. 3, pp. 333-340, Sep. 1993.
    • (1993) IEEE Trans. Energy Convers , vol.8 , Issue.3 , pp. 333-340
    • El-Serafi, A.M.1    Wu, J.2
  • 25
    • 0030120715 scopus 로고    scopus 로고
    • Analytical model of the cross magnetizing effect in saturated synchronous machines
    • J. C. Li, "Analytical model of the cross magnetizing effect in saturated synchronous machines," Electr. Power Syst. Res., vol. 37, pp. 19-28, 1996.
    • (1996) Electr. Power Syst. Res , vol.37 , pp. 19-28
    • Li, J.C.1
  • 26
    • 0034204533 scopus 로고    scopus 로고
    • Impact of dynamic cross-saturation on accuracy of saturated synchronous machine models
    • Jun
    • E. Levi, "Impact of dynamic cross-saturation on accuracy of saturated synchronous machine models," IEEE Trans. Energy Convers., vol. 15, no. 2, pp. 224-230, Jun. 2000.
    • (2000) IEEE Trans. Energy Convers , vol.15 , Issue.2 , pp. 224-230
    • Levi, E.1
  • 27
    • 0037351167 scopus 로고    scopus 로고
    • Methods for determining the q-axis saturation characteristics of salient-pole synchronous machines from the measured d-axis characteristics
    • Mar
    • A. M. El-Serafi and N. C. Kar, "Methods for determining the q-axis saturation characteristics of salient-pole synchronous machines from the measured d-axis characteristics," IEEE Trans. Energy Convers., vol. 18, no. 1, pp. 80-86, Mar. 2003.
    • (2003) IEEE Trans. Energy Convers , vol.18 , Issue.1 , pp. 80-86
    • El-Serafi, A.M.1    Kar, N.C.2
  • 31
    • 0004184001 scopus 로고    scopus 로고
    • Test Procedures for Synchronous Machine
    • Test Procedures for Synchronous Machine, IEEE/ANSI Standard 115, 1996.
    • (1996) IEEE/ANSI Standard , vol.115


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.