메뉴 건너뛰기




Volumn 18, Issue 1, 2003, Pages 80-86

Methods for determining the q-axis saturation characteristics of salient-pole synchronous machines from the measured d-axis characteristics

Author keywords

Q axis saturation characteristic; Salient pole synchronous machines; Saturation

Indexed keywords

ELECTRIC MACHINERY TESTING; ELECTRIC REACTANCE MEASUREMENT; MAGNETIC VARIABLES MEASUREMENT; MAGNETIZATION; MATHEMATICAL MODELS;

EID: 0037351167     PISSN: 08858969     EISSN: None     Source Type: Journal    
DOI: 10.1109/TEC.2002.808384     Document Type: Article
Times cited : (23)

References (10)
  • 2
    • 0012685185 scopus 로고
    • EPRI rep.: Determination of synchronous machine stability constants
    • "EPRI Rep.: Determination of Synchronous Machine Stability Constants,", Ontario Hydro, EL-1424, vol. 2, 1980.
    • (1980) Ontario Hydro, EL-1424 , vol.2
  • 4
    • 0012724770 scopus 로고    scopus 로고
    • An experimental method for determining the saturation characteristics in the intermediate axes of synchronous machines
    • A. M. El-Serafi and Y. Xu, "An experimental method for determining the saturation characteristics in the intermediate axes of synchronous machines," in Proc. Int. Conf. Elect. Mach., vol. II, 2000, pp. 1143-1147.
    • (2000) Proc. Int. Conf. Elect. Mach. , vol.2 , pp. 1143-1147
    • El-Serafi, A.M.1    Xu, Y.2
  • 5
    • 0023060823 scopus 로고
    • Representation of saturation in synchronous machines
    • Nov
    • F. P. deMello and L. N. Hannett, "Representation of saturation in synchronous machines," IEEE Trans. Power Syst., vol. 1, pp. 8-18, Nov. 1986.
    • (1986) IEEE Trans. Power Syst. , vol.1 , pp. 8-18
    • DeMello, F.P.1    Hannett, L.N.2
  • 6
    • 0033098897 scopus 로고    scopus 로고
    • Saturation modeling in d-q axis models of salient-pole synchronous machines
    • Mar
    • E. Levi, "Saturation modeling in d-q axis models of salient-pole synchronous machines," IEEE Trans. Energy Conversion, vol. 14, pp. 44-50, Mar. 1999.
    • (1999) IEEE Trans. Energy Conversion , vol.14 , pp. 44-50
    • Levi, E.1
  • 7
    • 0029517097 scopus 로고
    • A two factor saturation model for synchronous machines with multiple rotor circuits
    • Dec
    • S. Tahan and I. Kamwa, "A two factor saturation model for synchronous machines with multiple rotor circuits," IEEE Trans. Energy Conversion, vol. 10, pp. 609-616, Dec. 1995.
    • (1995) IEEE Trans. Energy Conversion , vol.10 , pp. 609-616
    • Tahan, S.1    Kamwa, I.2
  • 8
    • 0034262672 scopus 로고    scopus 로고
    • A new method to evaluate the q-axis saturation characteristic of cylindrical-rotor synchronous generators
    • Sept
    • N. C. Kar, T. Murata, and J. Tamura, "A new method to evaluate the q-axis saturation characteristic of cylindrical-rotor synchronous generators," IEEE Trans. Energy Conversion, vol. 15, pp. 269-276, Sept. 2000.
    • (2000) IEEE Trans. Energy Conversion , vol.15 , pp. 269-276
    • Kar, N.C.1    Murata, T.2    Tamura, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.