메뉴 건너뛰기




Volumn 8, Issue 1, 2008, Pages 118-141

Electrochemical sensors based on organic conjugated polymers

Author keywords

Amperometry; Biosensors; Chemical sensors; DNA sensors; Electrochemical methods; Gas sensors; Immunosensors; Impedance; Organic conjugated polymer; Potentiometry

Indexed keywords

BIOSENSORS; CHEMICAL SENSORS; CHEMICAL STABILITY; CONDUCTING POLYMERS; CONJUGATED POLYMERS; DIAGNOSIS; ELECTRIC IMPEDANCE; ELECTROCATALYSTS; ENZYME SENSORS; IMMUNOSENSORS; ORGANIC POLYMERS; POTENTIOMETERS (ELECTRIC MEASURING INSTRUMENTS); PUBLIC HEALTH; SOLUTIONS;

EID: 40849084035     PISSN: 14243210     EISSN: 14248220     Source Type: Journal    
DOI: 10.3390/s8010118     Document Type: Review
Times cited : (400)

References (137)
  • 1
    • 0003191230 scopus 로고    scopus 로고
    • Electrochemistry of π-Conjugated Polymers
    • Nalwa, H. S, Ed, Chichester, Wiley
    • Park, S.-M. Electrochemistry of π-Conjugated Polymers. In: Handbook of Organic Conductive Molecules and Polymers, Nalwa, H. S., Ed., Chichester, Wiley, 1997, Vol. 3, 429-469.
    • (1997) Handbook of Organic Conductive Molecules and Polymers , vol.3 , pp. 429-469
    • Park, S.-M.1
  • 4
    • 0025387728 scopus 로고
    • Electrochemistry of conductive polymers VIII, In situ spectroelectrochemical studies of polyaniline growth mechanisms
    • Shim, Y.-B.; Won, M.-S.; Park, S.-M. Electrochemistry of conductive polymers VIII, In situ spectroelectrochemical studies of polyaniline growth mechanisms. J. Electrochem. Soc. 1990, 137, 538-544.
    • (1990) J. Electrochem. Soc , vol.137 , pp. 538-544
    • Shim, Y.-B.1    Won, M.-S.2    Park, S.-M.3
  • 5
    • 0024963638 scopus 로고
    • Electrochemistry of conductive polymers VII, Autocatalytic rate constant for polyaniline growth
    • Shim, Y.-B.; Park, S.-M. Electrochemistry of conductive polymers VII, Autocatalytic rate constant for polyaniline growth, Synth. Met. 1989, 29, E169-E174.
    • (1989) Synth. Met , vol.29
    • Shim, Y.-B.1    Park, S.-M.2
  • 6
    • 0027682057 scopus 로고
    • Degradation kinetics of polypyrrole films
    • Park, D.-S.; Shim, Y.-B.; Park, S.-M. Degradation kinetics of polypyrrole films. J. Elrctrochem. Soc. 1993, 140, 2749-2752.
    • (1993) J. Elrctrochem. Soc , vol.140 , pp. 2749-2752
    • Park, D.-S.1    Shim, Y.-B.2    Park, S.-M.3
  • 7
    • 84975349562 scopus 로고
    • Degradation of electrochemically prepared polypyrrole in aqueous sulfuric acid
    • Park, D.-S.; Shim, Y.-B.; Park, S.-M. Degradation of electrochemically prepared polypyrrole in aqueous sulfuric acid. J. Elrctrochem. Soc. 1993, 140, 609-614.
    • (1993) J. Elrctrochem. Soc , vol.140 , pp. 609-614
    • Park, D.-S.1    Shim, Y.-B.2    Park, S.-M.3
  • 8
    • 0031237761 scopus 로고    scopus 로고
    • Electrochemistry of conductive polymers XXII, Electrochemical and spectroelectrochemical studies of polyazulene growth and its characterization
    • Shim, Y.-B.; Park, S.-M. Electrochemistry of conductive polymers XXII, Electrochemical and spectroelectrochemical studies of polyazulene growth and its characterization. J. Electrochem. Soc. 1997, 144, 3027-3033.
    • (1997) J. Electrochem. Soc , vol.144 , pp. 3027-3033
    • Shim, Y.-B.1    Park, S.-M.2
  • 9
    • 84876632921 scopus 로고    scopus 로고
    • rd ed.; Skotheim, T. A; Reynolds, J. R., Eds.; CRC press; Bocaraton, Florida, 2006, Chapter 13, 1-77.
    • rd ed.; Skotheim, T. A; Reynolds, J. R., Eds.; CRC press; Bocaraton, Florida, 2006, Chapter 13, 1-77.
  • 10
    • 84876642322 scopus 로고    scopus 로고
    • rd ed.; Skotheim, T. A; Reynolds, J. R., Eds.; CRC press; Bocaraton, Florida, 2006, Chapter 9, 1-49.
    • rd ed.; Skotheim, T. A; Reynolds, J. R., Eds.; CRC press; Bocaraton, Florida, 2006, Chapter 9, 1-49.
  • 11
    • 0026992126 scopus 로고
    • Electrochemical characterization of poly (1,8-diaminonaphthalene): A functionalized polymer
    • Lee, J.-W.; Park, D.-S.; Shim, Y.-B.; Park, S.-M. Electrochemical characterization of poly (1,8-diaminonaphthalene): a functionalized polymer. J. Electrochem. Soc. 1992, 139, 3507-3514.
    • (1992) J. Electrochem. Soc , vol.139 , pp. 3507-3514
    • Lee, J.-W.1    Park, D.-S.2    Shim, Y.-B.3    Park, S.-M.4
  • 12
    • 0039338883 scopus 로고
    • Resistance of polyaniline films as a function of electrochemical potential and the fabrication of polyaniline-based microelectronic devices
    • Paul, E.W.; Ricco, A.J.; Wrighton, M.S. Resistance of polyaniline films as a function of electrochemical potential and the fabrication of polyaniline-based microelectronic devices. J. Phys. Chem. 1985, 89, 1441-1447.
    • (1985) J. Phys. Chem , vol.89 , pp. 1441-1447
    • Paul, E.W.1    Ricco, A.J.2    Wrighton, M.S.3
  • 13
    • 33748480337 scopus 로고    scopus 로고
    • Kim, D. H, Kang, B. S, lim, S. M, Bark, K.-M, Kim, B. G, Shiro, M, Shim, Y.-B, Shin, S. C. Polyterthiophene-bearing pendant organomolybdenum complexes: electropolymerization of erythro-[Mo2(μ-C 5H5)2(CO)4{μ-η2: η2-C(R)=C[C4HS(C4H3S-2) 2-2,5, J. Chem. Soc. Dalton Trans. 1998, 1893-1898
    • 2-2,5]}]. J. Chem. Soc. Dalton Trans. 1998, 1893-1898.
  • 15
    • 0032688218 scopus 로고    scopus 로고
    • 9]-5,2 ;5, 2 -terthiophene. Synth. Met. 1999, 105, 9-12.
    • 9]-5,2 ;5, 2 -terthiophene. Synth. Met. 1999, 105, 9-12.
  • 16
    • 0005834424 scopus 로고    scopus 로고
    • Kim, D. H, Park, D. S, Shim, Y.-B, Shin, S. C. Polytherthiophene π-conjugated by organomolybdenum complex (II, electropolymerization of erythro, μ5-C5H5)2 Mo 2-(O)2(μ, O){μ-η2:η2- C(Ph)=C[C4HS(C4H3S-2)2-2,5, J. Organo. Met. 2000, 608, 133-138
    • 2-2,5]}]. J. Organo. Met. 2000, 608, 133-138.
  • 18
    • 0000402505 scopus 로고    scopus 로고
    • Bienzyme sensors based on poly(anilinomethylferrocene)modified electrodes
    • Mulchandani, A. K.; Wang, C. L. Bienzyme sensors based on poly(anilinomethylferrocene)modified electrodes. Electroanalysis 1996, 8, 414-419.
    • (1996) Electroanalysis , vol.8 , pp. 414-419
    • Mulchandani, A.K.1    Wang, C.L.2
  • 19
    • 0023499982 scopus 로고
    • Strategies for the development of amperometric enzyme electrodes
    • Bartlett, P. N.; Whitaker, R. G. Strategies for the development of amperometric enzyme electrodes. Biosensors 1988, 3, 359-379.
    • (1988) Biosensors , vol.3 , pp. 359-379
    • Bartlett, P.N.1    Whitaker, R.G.2
  • 21
    • 0033888434 scopus 로고    scopus 로고
    • Humidity sensor using chemically synthesized poly (1,5-diaminonaphthalene) doped with carbon
    • Shim, Y.-B.; Park, J.-H. Humidity sensor using chemically synthesized poly (1,5-diaminonaphthalene) doped with carbon, J. Eletrcochem. Soc. 2000, 147, 381-385.
    • (2000) J. Eletrcochem. Soc , vol.147 , pp. 381-385
    • Shim, Y.-B.1    Park, J.-H.2
  • 22
    • 0036642093 scopus 로고    scopus 로고
    • Eletcrocatalytic reduction of molecular oxygen using a polyterthiophene carboxylic acid) appended by 1,5-diamiononaphthalene copper complex
    • Boopathi, M.; Won, M.-S.; Kim, Y. H.; Shin, S. C.; Shim, Y.-B. Eletcrocatalytic reduction of molecular oxygen using a polyterthiophene carboxylic acid) appended by 1,5-diamiononaphthalene copper complex. J. Electrochem. Soc. 2002, 149, E265-E271.
    • (2002) J. Electrochem. Soc , vol.149
    • Boopathi, M.1    Won, M.-S.2    Kim, Y.H.3    Shin, S.C.4    Shim, Y.-B.5
  • 23
    • 0035958310 scopus 로고    scopus 로고
    • Lindfors T.; Ivaska, A. Calcium-selective electrode based on polyaniline functionalized with bis[4-(1,1,3,3-tetramethylbutyl)phenyl]phosphate. Anal. Chim. Acta 2001, 437, 171-182.
    • Lindfors T.; Ivaska, A. Calcium-selective electrode based on polyaniline functionalized with bis[4-(1,1,3,3-tetramethylbutyl)phenyl]phosphate. Anal. Chim. Acta 2001, 437, 171-182.
  • 24
    • 2542417489 scopus 로고    scopus 로고
    • Miniaturised all-solid-state Potentiometrie ion sensors based on PVC-membranes containing conducting polymers
    • Zachara, J. E.; Owska, R. T.; Pokrop, R.; Zagorska, M.; Dybko, A.; Wroblewski, W. Miniaturised all-solid-state Potentiometrie ion sensors based on PVC-membranes containing conducting polymers. Sens. Actuats. B 2004, 101, 207-212.
    • (2004) Sens. Actuats. B , vol.101 , pp. 207-212
    • Zachara, J.E.1    Owska, R.T.2    Pokrop, R.3    Zagorska, M.4    Dybko, A.5    Wroblewski, W.6
  • 25
    • 2942532644 scopus 로고    scopus 로고
    • Study of the glass/polypyrrole interface in an all-solid-state pH sensor
    • Kaden, H.; Jahn, H.; Berthold, M. Study of the glass/polypyrrole interface in an all-solid-state pH sensor. Solid State Ionics 2004, 169, 129-133.
    • (2004) Solid State Ionics , vol.169 , pp. 129-133
    • Kaden, H.1    Jahn, H.2    Berthold, M.3
  • 26
    • 0344474538 scopus 로고    scopus 로고
    • Hydrogen ion selective electrode based on poly(1-aminoanthracene) film
    • Faria, R. C.; Bulhões, L. O. S. Hydrogen ion selective electrode based on poly(1-aminoanthracene) film. Anal. Chim. Acta 1998, 377, 21-27.
    • (1998) Anal. Chim. Acta , vol.377 , pp. 21-27
    • Faria, R.C.1    Bulhões, L.O.S.2
  • 27
    • 33745809160 scopus 로고    scopus 로고
    • + sensor based on poly(3,4-ethylenedioxythiophene) doped with silver hexabromocarborane
    • + sensor based on poly(3,4-ethylenedioxythiophene) doped with silver hexabromocarborane. J. Electroanal. Chem. 2006, 593, 219-226.
    • (2006) J. Electroanal. Chem , vol.593 , pp. 219-226
    • Mousavi, Z.1    Bobacka, J.2    Lewenstam, A.3    Ivaska, A.4
  • 28
    • 0033000182 scopus 로고    scopus 로고
    • Plasticizer-free all-solid-state potassium-selective electrode based on poly (3-octylthiophene) and valinomycin
    • Bobacka, J.; Ivaska, A.; Lewenstam, A. Plasticizer-free all-solid-state potassium-selective electrode based on poly (3-octylthiophene) and valinomycin Anal. Chim. Acta 1999, 385, 195-202.
    • (1999) Anal. Chim. Acta , vol.385 , pp. 195-202
    • Bobacka, J.1    Ivaska, A.2    Lewenstam, A.3
  • 29
    • 34247163643 scopus 로고    scopus 로고
    • Functional Polythiophene Nanoparticles: Size-Controlled Electropolymerization and Ion Selective Response
    • Si, P.; Chi, O.; Li, Z.; Ulstrup, J.; Muller, P. J.; Mortensen, J. Functional Polythiophene Nanoparticles: Size-Controlled Electropolymerization and Ion Selective Response. J. Am. Chem. Soc. 2007, 129, 3888-3896.
    • (2007) J. Am. Chem. Soc , vol.129 , pp. 3888-3896
    • Si, P.1    Chi, O.2    Li, Z.3    Ulstrup, J.4    Muller, P.J.5    Mortensen, J.6
  • 30
    • 33847026156 scopus 로고    scopus 로고
    • A potentiometric and voltammetric sensor based on polypyrrole film with electrochemically induced recognition sites for detection of silver ion
    • Zanganeh, A. R.; Amini, M. K.; A potentiometric and voltammetric sensor based on polypyrrole film with electrochemically induced recognition sites for detection of silver ion. Electrochim. Acta 2007, 52, 3822-3830.
    • (2007) Electrochim. Acta , vol.52 , pp. 3822-3830
    • Zanganeh, A.R.1    Amini, M.K.2
  • 32
    • 27144440324 scopus 로고    scopus 로고
    • Voltammetric determination of trace mercury at a sonogel-carbon electrode modified with poly-3-methylthiophene
    • Zejli, H.; Sharrock, P.; Hidalgo-Hidalgo de Cisneros, J.L.; Naranjo-Rodriguez, I.; Temsamani, K. R. Voltammetric determination of trace mercury at a sonogel-carbon electrode modified with poly-3-methylthiophene. Talanta 2006, 68, 79-85.
    • (2006) Talanta , vol.68 , pp. 79-85
    • Zejli, H.1    Sharrock, P.2    Hidalgo-Hidalgo de Cisneros, J.L.3    Naranjo-Rodriguez, I.4    Temsamani, K.R.5
  • 33
    • 11444269212 scopus 로고    scopus 로고
    • Trace analysis of Al (III) ions based on the redox current of a conducting polymer
    • Seol, H.; Shin, S. C.; Shim, Y. B. Trace analysis of Al (III) ions based on the redox current of a conducting polymer. Electroanalysis 2004, 16, 2051-2057.
    • (2004) Electroanalysis , vol.16 , pp. 2051-2057
    • Seol, H.1    Shin, S.C.2    Shim, Y.B.3
  • 34
    • 0002093954 scopus 로고    scopus 로고
    • Characterization of electrochemically prepared polyaminopyridines
    • Park, D.-S.; Shim, Y.-B.; Park, S.-M. Characterization of electrochemically prepared polyaminopyridines. Electroanalysis 1996, 8, 44-49.
    • (1996) Electroanalysis , vol.8 , pp. 44-49
    • Park, D.-S.1    Shim, Y.-B.2    Park, S.-M.3
  • 35
    • 0037356974 scopus 로고    scopus 로고
    • Characterization of an EDTA bonded conducting polymer modified electrode: Its application for the simultaneous determination of heavy metal ions
    • Rahman, M. A.; Won. M.-S.; Shim, Y.-B. Characterization of an EDTA bonded conducting polymer modified electrode: its application for the simultaneous determination of heavy metal ions. Anal. Chem. 2003, 75, 1123-1129.
    • (2003) Anal. Chem , vol.75 , pp. 1123-1129
    • Rahman, M.A.1    Won, M.-S.2    Shim, Y.-B.3
  • 36
    • 4544284199 scopus 로고    scopus 로고
    • Selective electrochemical analysis of various metal ions at an EDTA bonded conducting polymer modified electrode
    • Rahman, M. A.; Park, D.-S.; Won, M.-S.; Park, S.-M.; Shim, Y.-B. Selective electrochemical analysis of various metal ions at an EDTA bonded conducting polymer modified electrode. Electroanalysis 2004, 16, 1366-1370.
    • (2004) Electroanalysis , vol.16 , pp. 1366-1370
    • Rahman, M.A.1    Park, D.-S.2    Won, M.-S.3    Park, S.-M.4    Shim, Y.-B.5
  • 38
    • 27844531688 scopus 로고    scopus 로고
    • Determination of Selenium with a Poly(1,8-diaminonaphthalene)-Modified Electrode
    • Won, M. S.; Yoon, J. H.; Shim, Y. B. Determination of Selenium with a Poly(1,8-diaminonaphthalene)-Modified Electrode. Electroanalysis 2005, 17, 1952-1958.
    • (2005) Electroanalysis , vol.17 , pp. 1952-1958
    • Won, M.S.1    Yoon, J.H.2    Shim, Y.B.3
  • 39
    • 7644224476 scopus 로고    scopus 로고
    • Factors Affecting the Potentiometrie Response of All-Solid-State Solvent Polymeric Membrane Calcium-Selective Electrode for Low-Level Measurements
    • Konopka, A.; Sokalski, T.; Michalska, A.; Lewenstam, A.; Maj-Zurawska, M. Factors Affecting the Potentiometrie Response of All-Solid-State Solvent Polymeric Membrane Calcium-Selective Electrode for Low-Level Measurements. Anal. Chem. 2004, 76, 6410 -6418.
    • (2004) Anal. Chem , vol.76 , pp. 6410-6418
    • Konopka, A.1    Sokalski, T.2    Michalska, A.3    Lewenstam, A.4    Maj-Zurawska, M.5
  • 40
    • 0000377499 scopus 로고    scopus 로고
    • Fabrication and Characterization of a Hydroquinone-Functionalized Polypyrrole Thin-Film pH Sensor
    • Aquino-Binag, C. N.; Kumar, N.; Lamb, R. N.; Pigram, P. J. Fabrication and Characterization of a Hydroquinone-Functionalized Polypyrrole Thin-Film pH Sensor. Chem. Mater. 1996, 8, 2579-2585.
    • (1996) Chem. Mater , vol.8 , pp. 2579-2585
    • Aquino-Binag, C.N.1    Kumar, N.2    Lamb, R.N.3    Pigram, P.J.4
  • 41
    • 0001023146 scopus 로고    scopus 로고
    • Ionochromic and Potentiometric Properties of the Novel Polyconjugated Polymer from Anodic Coupling of 5,5'-Bis(3,4-(ethylenedioxy)thien-2-yl)-2,2'-bipyridine
    • Zotti, G.; Zecchin, S.; Schiavon, G.; Berlin A.; Penso, M. Ionochromic and Potentiometric Properties of the Novel Polyconjugated Polymer from Anodic Coupling of 5,5'-Bis(3,4-(ethylenedioxy)thien-2-yl)-2,2'-bipyridine Chem. Mater. 1999, 11, 3342 -3351.
    • (1999) Chem. Mater , vol.11 , pp. 3342-3351
    • Zotti, G.1    Zecchin, S.2    Schiavon, G.3    Berlin, A.4    Penso, M.5
  • 42
    • 0034130256 scopus 로고    scopus 로고
    • Enzymatically and Combinatorially Generated Array-Based Polyphenol Metal Ion Sensor
    • Wu, X.; Kim, J.; Dordick, J. S. Enzymatically and Combinatorially Generated Array-Based Polyphenol Metal Ion Sensor. Biotechnol. Prog. 2000, 16, 513-516.
    • (2000) Biotechnol. Prog , vol.16 , pp. 513-516
    • Wu, X.1    Kim, J.2    Dordick, J.S.3
  • 43
    • 84988097470 scopus 로고
    • The behavior of polypyrrole doped with different anions as an ion-selective electrode
    • Jovanovi V. M.; Markievi, L.; Stankovi, S.; Stankovi, R.; Jovanovi, M. S. The behavior of polypyrrole doped with different anions as an ion-selective electrode Electroanalysis 1995, 7, 574-578.
    • (1995) Electroanalysis , vol.7 , pp. 574-578
    • Jovanovi, V.M.1    Markievi, L.2    Stankovi, S.3    Stankovi, R.4    Jovanovi, M.S.5
  • 44
    • 34347324925 scopus 로고    scopus 로고
    • Sulfonated poly(ether ether ketone), an ion conducting polymer, as alternative polymeric membrane for the construction of anion-selective electrodes
    • Gonzalez-Bellavista, A. G.; Macanas, J.; Munoz, M.; Fabregas, E. Sulfonated poly(ether ether ketone), an ion conducting polymer, as alternative polymeric membrane for the construction of anion-selective electrodes. Sens. Actuat. B 2007, 125, 100-105.
    • (2007) Sens. Actuat. B , vol.125 , pp. 100-105
    • Gonzalez-Bellavista, A.G.1    Macanas, J.2    Munoz, M.3    Fabregas, E.4
  • 45
    • 35349005267 scopus 로고    scopus 로고
    • All-solid-state chloride sensors based on electronically conducting, semiconducting and insulating polymer membranes
    • doi: 10.1016.j.snb.2007.05.004
    • Sjoberg-Eerola, P.; Bobaccka, J.; Lewenstam, A.; Ivaska, A. All-solid-state chloride sensors based on electronically conducting, semiconducting and insulating polymer membranes. Sens. Actuat. B 2007, doi: 10.1016.j.snb.2007.05.004.
    • (2007) Sens. Actuat. B
    • Sjoberg-Eerola, P.1    Bobaccka, J.2    Lewenstam, A.3    Ivaska, A.4
  • 46
    • 29144516685 scopus 로고    scopus 로고
    • Rahman, M. A.; Park, D. S.; Chang, S. C.; C; McNeil, C. J.; Shim, Y. B. The biosensor based on the pyruvate oxidase modified conducting polymer for phosphate ions determinations. Biosens. Bioelectron. 2006, 21, 1116-1124.
    • Rahman, M. A.; Park, D. S.; Chang, S. C.; C; McNeil, C. J.; Shim, Y. B. The biosensor based on the pyruvate oxidase modified conducting polymer for phosphate ions determinations. Biosens. Bioelectron. 2006, 21, 1116-1124.
  • 47
    • 34248591273 scopus 로고    scopus 로고
    • Overoxidized polypyrrole film directed single-walled carbon nanotubes immobilization on glassy carbon electrode and its sensing applications
    • Li, Y.; Wang, P.; Wang, L.; Lin, X. Overoxidized polypyrrole film directed single-walled carbon nanotubes immobilization on glassy carbon electrode and its sensing applications. Biosens. Bioelectron. 2007, 22, 3120-3125.
    • (2007) Biosens. Bioelectron , vol.22 , pp. 3120-3125
    • Li, Y.1    Wang, P.2    Wang, L.3    Lin, X.4
  • 48
    • 25844462334 scopus 로고    scopus 로고
    • Long-lived solid state perchlorate ion selective sensor based on doped poly(3,4-ethylenedioxythiophene) (PEDOT) films
    • Bendikov, T.A.; Harmon, T. C. Long-lived solid state perchlorate ion selective sensor based on doped poly(3,4-ethylenedioxythiophene) (PEDOT) films. Anal. Chim. Acta 2005, 551, 30-36.
    • (2005) Anal. Chim. Acta , vol.551 , pp. 30-36
    • Bendikov, T.A.1    Harmon, T.C.2
  • 50
    • 0032428042 scopus 로고    scopus 로고
    • Conducting polymer ion sensor electrodes-III. Potentiometric sulfide ion selective electrode
    • Atta, N. F.; Galai, A.; Mark Jr, H. B.; Yu, T.; Bishop, P. L. Conducting polymer ion sensor electrodes-III. Potentiometric sulfide ion selective electrode. Talanta 1998, 47, 987-999.
    • (1998) Talanta , vol.47 , pp. 987-999
    • Atta, N.F.1    Galai, A.2    Mark Jr, H.B.3    Yu, T.4    Bishop, P.L.5
  • 51
    • 0031126132 scopus 로고    scopus 로고
    • Voltammetric detection of NO in the rat brain with an electronic conducting polymer and Nation bilayer-coated carbon fibre electrode
    • Fabre, B.; Burlet, S.; Cespuglio, R.; Bidan, G. Voltammetric detection of NO in the rat brain with an electronic conducting polymer and Nation bilayer-coated carbon fibre electrode. J. Electroanal. Chem. 1997, 426, 75-83.
    • (1997) J. Electroanal. Chem , vol.426 , pp. 75-83
    • Fabre, B.1    Burlet, S.2    Cespuglio, R.3    Bidan, G.4
  • 52
    • 4544314072 scopus 로고    scopus 로고
    • All-Solid-State Chloride Sensors with Poly(3-Octylthiopene) Matrix and Trihexadecylmethylammonium Chlorides as an Ion Exchanger Salt
    • Sjöberg-Eerola, P.; Bobacka, J.; Sokalski, T.; Mieczkowski, J.; Ivaska, A.; Lewenstam, A. All-Solid-State Chloride Sensors with Poly(3-Octylthiopene) Matrix and Trihexadecylmethylammonium Chlorides as an Ion Exchanger Salt. Electroanalysis 2004, 16, 379-385.
    • (2004) Electroanalysis , vol.16 , pp. 379-385
    • Sjöberg-Eerola, P.1    Bobacka, J.2    Sokalski, T.3    Mieczkowski, J.4    Ivaska, A.5    Lewenstam, A.6
  • 53
    • 26444544495 scopus 로고    scopus 로고
    • + Sensors Based on Conducting Polymers: A Comparison between Poly (3,4-ethylenedioxythiophene) and Polypyrrole Doped with Sulfonated Calixarenes
    • + Sensors Based on Conducting Polymers: A Comparison between Poly (3,4-ethylenedioxythiophene) and Polypyrrole Doped with Sulfonated Calixarenes. Electroanalysis 2005, 17, 1609-1615.
    • (2005) Electroanalysis , vol.17 , pp. 1609-1615
    • Mousavi, Z.1    Bobacka, J.2    Ivaska, A.3
  • 54
    • 35748954347 scopus 로고    scopus 로고
    • Sutar, D.S.; Padma, N.; Aswal, D.K.; Deshpande, S.K.; Gupta, S.K.; Yakhmi, J.V. Preparation of nanofibrous polyaniline films and their application as ammonia gas sensor. Sens. Actuats. B 2007, doi:10:1016/j.snb. 2007.06.015.
    • Sutar, D.S.; Padma, N.; Aswal, D.K.; Deshpande, S.K.; Gupta, S.K.; Yakhmi, J.V. Preparation of nanofibrous polyaniline films and their application as ammonia gas sensor. Sens. Actuats. B 2007, doi:10:1016/j.snb. 2007.06.015.
  • 55
    • 0035873863 scopus 로고    scopus 로고
    • Conducting polyaniline composite: A reusable sensor material for aqueous ammonia
    • Koull, S.; Chandra, R.; Dhawan, S.K. Conducting polyaniline composite: a reusable sensor material for aqueous ammonia. Sens. Actuats. B 2001, 75, 151-159.
    • (2001) Sens. Actuats. B , vol.75 , pp. 151-159
    • Koull, S.1    Chandra, R.2    Dhawan, S.K.3
  • 57
    • 34548127957 scopus 로고    scopus 로고
    • Poly-(3-methylthiophene)/carbon nanotubes hybrid composite-modified electrodes
    • Agüí, L.; Peña-Farfal, C.; Yáñez- Sedeño, P.; Pingarrón, J. M. Poly-(3-methylthiophene)/carbon nanotubes hybrid composite-modified electrodes. Electrochim Acta 2007, 52, 7946-7952.
    • (2007) Electrochim Acta , vol.52 , pp. 7946-7952
    • Agüí, L.1    Peña-Farfal, C.2    Yáñez- Sedeño, P.3    Pingarrón, J.M.4
  • 58
    • 34347355212 scopus 로고    scopus 로고
    • Conducting polypyrrole modified with ferrocene for applications in carbon monoxide sensors
    • Radhakrishnan, S.; Paul, S. Conducting polypyrrole modified with ferrocene for applications in carbon monoxide sensors. Sens. Actuats. B 2007, 125, 60-65.
    • (2007) Sens. Actuats. B , vol.125 , pp. 60-65
    • Radhakrishnan, S.1    Paul, S.2
  • 59
    • 3042735808 scopus 로고    scopus 로고
    • Reduction of interference signal of ascorbate and urate in poly(pyrrole)-based ammonia sensors in aqueous solutions
    • Vidotti, M.; Antonia, L. D.; Cintra, E. P.; Torresi, S. C. Reduction of interference signal of ascorbate and urate in poly(pyrrole)-based ammonia sensors in aqueous solutions. Electrochim. Acta 2004, 49, 3665-3670.
    • (2004) Electrochim. Acta , vol.49 , pp. 3665-3670
    • Vidotti, M.1    Antonia, L.D.2    Cintra, E.P.3    Torresi, S.C.4
  • 60
    • 2342642061 scopus 로고    scopus 로고
    • A sensor for acetaminophen in a blood medium using a Cu (II)-conducting polymer complex modified electrode
    • Boopathi, M.; Won, M. S.; Shim, Y.-B. A sensor for acetaminophen in a blood medium using a Cu (II)-conducting polymer complex modified electrode. Anal. Chim. Acta 2004, 512, 191-197.
    • (2004) Anal. Chim. Acta , vol.512 , pp. 191-197
    • Boopathi, M.1    Won, M.S.2    Shim, Y.-B.3
  • 61
    • 84876637573 scopus 로고    scopus 로고
    • Calbreath, D. F. The Scope of Clinical Chemistry, In: Clinical Chemistry. A Fundamental Text book, S. Ozmar Ed., Philadelphia: W.B. Saunders Company, 1992; pp 3-9.
    • Calbreath, D. F. The Scope of Clinical Chemistry, In: Clinical Chemistry. A Fundamental Text book, S. Ozmar Ed., Philadelphia: W.B. Saunders Company, 1992; pp 3-9.
  • 63
    • 0038723051 scopus 로고    scopus 로고
    • Introduction to chemical and biological sensors
    • Taylor, R. F, Schultz, J.S. Eds, London: IOP
    • Schultz, J.S.; Taylor, R. F. Introduction to chemical and biological sensors, In: Handbook of chemical and biological sensors, Taylor, R. F.; Schultz, J.S. Eds., London: IOP, 1996; pp 1-10.
    • (1996) Handbook of chemical and biological sensors , pp. 1-10
    • Schultz, J.S.1    Taylor, R.F.2
  • 64
    • 84876596852 scopus 로고    scopus 로고
    • Scheller, F. W.; Schubert, F.; Fedowitz, J. Present state and frontiers in biosensorics, In: Frontiers in biosensorics I. Fundamental aspects, Scheller, F. W.; Schubert, F.; Fedowitz, J. Eds., Basel: Birkhauser Verlag, 1997; pp 1-12.
    • Scheller, F. W.; Schubert, F.; Fedowitz, J. Present state and frontiers in biosensorics, In: Frontiers in biosensorics I. Fundamental aspects, Scheller, F. W.; Schubert, F.; Fedowitz, J. Eds., Basel: Birkhauser Verlag, 1997; pp 1-12.
  • 66
    • 0038709731 scopus 로고    scopus 로고
    • Carbon nanotube/Teflon composite electrochemical sensors and biosensors
    • Wang, J.; Musameh, M. Carbon nanotube/Teflon composite electrochemical sensors and biosensors. Anal. Chem. 2003, 75, 2075-2079.
    • (2003) Anal. Chem , vol.75 , pp. 2075-2079
    • Wang, J.1    Musameh, M.2
  • 67
    • 0026476896 scopus 로고
    • Electroconducting conjugated polymers. New sensitive matrices to build up chemical or electrochemical sensors. A review
    • Bidan, G. Electroconducting conjugated polymers. New sensitive matrices to build up chemical or electrochemical sensors. A review. Sens. Actuat. B 1992, 6, 45-56.
    • (1992) Sens. Actuat. B , vol.6 , pp. 45-56
    • Bidan, G.1
  • 68
    • 0038281980 scopus 로고
    • A review of the immobilization of enzymes in electropolymerized films
    • Bartlett, P. N.; Cooper, J. M. A review of the immobilization of enzymes in electropolymerized films. J. Electroanal. Chem. 1993, 362, 1-12.
    • (1993) J. Electroanal. Chem , vol.362 , pp. 1-12
    • Bartlett, P.N.1    Cooper, J.M.2
  • 69
    • 0033620585 scopus 로고    scopus 로고
    • Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review
    • Cosnier, S. "Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review", Biosens. Bioelectron. 1999, 14, 443-456.
    • (1999) Biosens. Bioelectron , vol.14 , pp. 443-456
    • Cosnier, S.1
  • 70
    • 0036125073 scopus 로고    scopus 로고
    • Application of conducting polymers to biosensors
    • Gerard, M.; Chaubey, A.; Malhotra, B. D. Application of conducting polymers to biosensors. Biosens. Bioelectron. 2002, 17, 345-359.
    • (2002) Biosens. Bioelectron , vol.17 , pp. 345-359
    • Gerard, M.1    Chaubey, A.2    Malhotra, B.D.3
  • 71
    • 33845374035 scopus 로고
    • Protein modified electrodes. The glucose oxidase / polypyrrole system
    • Umana, M.; Waller, J. Protein modified electrodes. The glucose oxidase / polypyrrole system. Anal. Chem. 1986, 64, 2979-2983.
    • (1986) Anal. Chem , vol.64 , pp. 2979-2983
    • Umana, M.1    Waller, J.2
  • 72
    • 0039633245 scopus 로고
    • Enzyme entrapment in electrically conducting polymers. Immobilisation of glucose oxidase in polypyrrole and its application in amperometric glucose sensors
    • Foulds, N. C.; Lowe, C. R. Enzyme entrapment in electrically conducting polymers. Immobilisation of glucose oxidase in polypyrrole and its application in amperometric glucose sensors. J. Chem. Soc. Faraday Trans. I 1986, 82, 1259-1264.
    • (1986) J. Chem. Soc. Faraday Trans. I , vol.82 , pp. 1259-1264
    • Foulds, N.C.1    Lowe, C.R.2
  • 73
    • 10244223555 scopus 로고
    • Electrode systems for continuous monitoring cardiovascular surgery
    • Clark, L. C. Jr.; Lyons, C. Electrode systems for continuous monitoring cardiovascular surgery, Ann. N. Y. Acad. Sci. 1962, 102, 29-45.
    • (1962) Ann. N. Y. Acad. Sci , vol.102 , pp. 29-45
    • Clark Jr., L.C.1    Lyons, C.2
  • 75
    • 23044477090 scopus 로고    scopus 로고
    • Functionalized conducting polymer as an enzyme-immobilizing substrate: An amperometric glutamate microbiosensor for in vivo measurements
    • Rahman M. A.; Kwon, N.-H.; Won, M.-S.; Choe, E. S.; Shim, Y.-B. Functionalized conducting polymer as an enzyme-immobilizing substrate: an amperometric glutamate microbiosensor for in vivo measurements, Anal. Chem. 2005, 77, 4854-4860.
    • (2005) Anal. Chem , vol.77 , pp. 4854-4860
    • Rahman, M.A.1    Kwon, N.-H.2    Won, M.-S.3    Choe, E.S.4    Shim, Y.-B.5
  • 76
    • 34547621597 scopus 로고    scopus 로고
    • Xanthine sensors based on anodic and cathodic detection of enzymatically generated hydrogen peroxide
    • Rahman, M. A.; Won, M.-S.; Shim, Y.-B. Xanthine sensors based on anodic and cathodic detection of enzymatically generated hydrogen peroxide. Electroanalysis 2007, 19, 631-637.
    • (2007) Electroanalysis , vol.19 , pp. 631-637
    • Rahman, M.A.1    Won, M.-S.2    Shim, Y.-B.3
  • 77
    • 34548573562 scopus 로고    scopus 로고
    • Superoxide radical sensing using a cytochrome c 3 immobilized conducting polymer electrode
    • Darain, F.; Park, J.-S.; Akutsu, H.; Shim, Y.-B. Superoxide radical sensing using a cytochrome c 3 immobilized conducting polymer electrode. Biosens. Bioelectron. 2007, 23, 161-167.
    • (2007) Biosens. Bioelectron , vol.23 , pp. 161-167
    • Darain, F.1    Park, J.-S.2    Akutsu, H.3    Shim, Y.-B.4
  • 78
    • 30044435620 scopus 로고    scopus 로고
    • Lipid-bonded conducting polymer layers for a model biomembrane: Application to superoxide biosensors
    • Kwon, N.-H.; Rahman, M. A.; Won, M.-S.; Shim, Y.-B. Lipid-bonded conducting polymer layers for a model biomembrane: application to superoxide biosensors. Anal. Chem. 2006, 78, 52-60.
    • (2006) Anal. Chem , vol.78 , pp. 52-60
    • Kwon, N.-H.1    Rahman, M.A.2    Won, M.-S.3    Shim, Y.-B.4
  • 79
    • 22044441010 scopus 로고    scopus 로고
    • The potential use of hydrazine as an alternative to peroxidase in a biosensor: Comparison between hydrazine and HRP-based glucose sensors
    • Rahman, M. A.; Won, M.-S.; Shim, Y.-B. The potential use of hydrazine as an alternative to peroxidase in a biosensor: comparison between hydrazine and HRP-based glucose sensors. Biosens. Bioelectron. 2005, 21, 257-265.
    • (2005) Biosens. Bioelectron , vol.21 , pp. 257-265
    • Rahman, M.A.1    Won, M.-S.2    Shim, Y.-B.3
  • 80
    • 29644441518 scopus 로고    scopus 로고
    • Detection of polymerase chain reaction fragments using a conducting polymer-modified screen-printed electrode in a microfluidic device
    • Shiddiky, M. J. A.; Park, D.-S.; Shim, Y.-B. Detection of polymerase chain reaction fragments using a conducting polymer-modified screen-printed electrode in a microfluidic device. Electrophoresis 2005, 26, 4656-4663.
    • (2005) Electrophoresis , vol.26 , pp. 4656-4663
    • Shiddiky, M.J.A.1    Park, D.-S.2    Shim, Y.-B.3
  • 81
    • 33746694745 scopus 로고    scopus 로고
    • Analysis of polymerase chain reaction amplifications through phosphate detection using an enzyme-based microbiosensor in a microfluidic device
    • Shiddiky, M. J. A.; Rahman, M. A.; Park, J.-S.; Shim, Y.-B. Analysis of polymerase chain reaction amplifications through phosphate detection using an enzyme-based microbiosensor in a microfluidic device. Electrophoresis 2006, 27, 2951-2959.
    • (2006) Electrophoresis , vol.27 , pp. 2951-2959
    • Shiddiky, M.J.A.1    Rahman, M.A.2    Park, J.-S.3    Shim, Y.-B.4
  • 82
    • 0035850579 scopus 로고    scopus 로고
    • Hydrogen peroxide biosensor with enzyme entrapped within electrodeposited polypyrrole based on mediated sol-gel derived composite carbon electrode
    • Tian, F.; Xu, B.; Zhu, G.; Zhu, L. Hydrogen peroxide biosensor with enzyme entrapped within electrodeposited polypyrrole based on mediated sol-gel derived composite carbon electrode. Anal. Chim. Acta 2001, 443, 9-16.
    • (2001) Anal. Chim. Acta , vol.443 , pp. 9-16
    • Tian, F.1    Xu, B.2    Zhu, G.3    Zhu, L.4
  • 83
    • 0242637456 scopus 로고    scopus 로고
    • Fabrication of glucose oxidase/polypyrrole biosensor by galvanostatic method in various pH aqueous solutions
    • Uang, Y. M.; Chou, T. C. Fabrication of glucose oxidase/polypyrrole biosensor by galvanostatic method in various pH aqueous solutions. Biosens. Bioelectron. 2003, 19, 141-147.
    • (2003) Biosens. Bioelectron , vol.19 , pp. 141-147
    • Uang, Y.M.1    Chou, T.C.2
  • 84
    • 2942571195 scopus 로고    scopus 로고
    • Glucose oxidase electrode for polyaniline, poly(o-toluidine and their copolymers for advance technology
    • Borole, D. D.; Kapadi, U. R.; Mahulikar, P.P.; Hundiwale, D. G. Glucose oxidase electrode for polyaniline, poly(o-toluidine and their copolymers for advance technology. Polym. Adv. Technol. 2003, 15, 306-312.
    • (2003) Polym. Adv. Technol , vol.15 , pp. 306-312
    • Borole, D.D.1    Kapadi, U.R.2    Mahulikar, P.P.3    Hundiwale, D.G.4
  • 85
    • 5344228243 scopus 로고    scopus 로고
    • A Neural Network Model in the Calibration of Glucose Sensor Based on the Immobilization of Glucose Oxidase into Polypyrrole Matrix
    • Seker, S.; Becerik, I. A Neural Network Model in the Calibration of Glucose Sensor Based on the Immobilization of Glucose Oxidase into Polypyrrole Matrix. Electroanalysis 2004, 16, 1542-1549.
    • (2004) Electroanalysis , vol.16 , pp. 1542-1549
    • Seker, S.1    Becerik, I.2
  • 87
    • 8844245653 scopus 로고    scopus 로고
    • Pt based enzyme electrode probes assembled with Prussian Blue and conducting polymer nanostructures
    • Curulli, A.; Valentini, F.; Orlanduci, S.; Terranova, M.L.; Palleschi, G. Pt based enzyme electrode probes assembled with Prussian Blue and conducting polymer nanostructures. Biosens. Bioelectron. 2004, 20, 1223-1232.
    • (2004) Biosens. Bioelectron , vol.20 , pp. 1223-1232
    • Curulli, A.1    Valentini, F.2    Orlanduci, S.3    Terranova, M.L.4    Palleschi, G.5
  • 89
    • 16244423720 scopus 로고    scopus 로고
    • Immobilization of tyrosinase in polysiloxane/polypyrrole copolymer matrices
    • Arslan, A.; Kiralp, S.; Toppare, L.; Yagci, Y. Immobilization of tyrosinase in polysiloxane/polypyrrole copolymer matrices. Int. J. Biol. Macromole. 2005, 35, 163-167.
    • (2005) Int. J. Biol. Macromole , vol.35 , pp. 163-167
    • Arslan, A.1    Kiralp, S.2    Toppare, L.3    Yagci, Y.4
  • 90
    • 0037369655 scopus 로고    scopus 로고
    • Amperometric tyrosinase based biosensor using an electrogenerated polythiophene film as an entrapment support
    • Vedrine, C.; Fabiano, S.; Tran-Minh, C. Amperometric tyrosinase based biosensor using an electrogenerated polythiophene film as an entrapment support. Talanta 2003, 59, 535-544.
    • (2003) Talanta , vol.59 , pp. 535-544
    • Vedrine, C.1    Fabiano, S.2    Tran-Minh, C.3
  • 91
    • 33748631091 scopus 로고    scopus 로고
    • Preparation of biosensors by immobilization of polyphenol oxidase in conducting copolymers and their use in determination of phenolic compounds in red wine
    • Boyukbayram, A.E.; Kiralp, S.; Toppare, L.; Yagci, Y. Preparation of biosensors by immobilization of polyphenol oxidase in conducting copolymers and their use in determination of phenolic compounds in red wine. Bioelectrochemistry 2006, 69, 164-171.
    • (2006) Bioelectrochemistry , vol.69 , pp. 164-171
    • Boyukbayram, A.E.1    Kiralp, S.2    Toppare, L.3    Yagci, Y.4
  • 92
    • 14744294879 scopus 로고    scopus 로고
    • Sensing characteristics of polypyrrole-poly(vinyl alcohol) methanol sensors prepared by in situ vapor state polymerization
    • Jiang, L.; Jun, H.K.;. Hoh, Y.S.; Lim, J.O.; Lee, D.D.; Huh, J.S. Sensing characteristics of polypyrrole-poly(vinyl alcohol) methanol sensors prepared by in situ vapor state polymerization. Sens. Actuators B 2005, 105, 132-137.
    • (2005) Sens. Actuators B , vol.105 , pp. 132-137
    • Jiang, L.1    Jun, H.K.2    Hoh, Y.S.3    Lim, J.O.4    Lee, D.D.5    Huh, J.S.6
  • 93
    • 2442580884 scopus 로고    scopus 로고
    • Polyaniline-uricase biosensor prepared with template process
    • _
    • Kan, J.; Pan, X.; Chen, C._Polyaniline-uricase biosensor prepared with template process. Biosens. Bioelectron. 2004, 19, 1635-1640.
    • (2004) Biosens. Bioelectron , vol.19 , pp. 1635-1640
    • Kan, J.1    Pan, X.2    Chen, C.3
  • 94
    • 33646524944 scopus 로고    scopus 로고
    • The development of a regentless lactate biosensor based on a novel conducting polymer
    • Haccoun, J.; Piro, B.; Noel, V.; Pham, M. C. The development of a regentless lactate biosensor based on a novel conducting polymer. Bioelectrochemistry. 2006, 68, 218-236.
    • (2006) Bioelectrochemistry , vol.68 , pp. 218-236
    • Haccoun, J.1    Piro, B.2    Noel, V.3    Pham, M.C.4
  • 95
    • 0037094053 scopus 로고    scopus 로고
    • Modified electrodes for NADH oxidation and dehydrogenase-based biosensors
    • Bartlett, P. N.; Simon, E.; Toh, C.S.; Modified electrodes for NADH oxidation and dehydrogenase-based biosensors. Bioelectrochemistry 2002, 56, 117-122.
    • (2002) Bioelectrochemistry , vol.56 , pp. 117-122
    • Bartlett, P.N.1    Simon, E.2    Toh, C.S.3
  • 96
    • 0033968377 scopus 로고    scopus 로고
    • Co-immobilization of lactate oxidase and lactate dehydrogenase on conducting polyaniline films
    • Chaubey, A.; Pande, K.K.; Singh, V.S.; Malhotra, B.D. Co-immobilization of lactate oxidase and lactate dehydrogenase on conducting polyaniline films. Anal. Chim. Acta 2000, 407, 97-103.
    • (2000) Anal. Chim. Acta , vol.407 , pp. 97-103
    • Chaubey, A.1    Pande, K.K.2    Singh, V.S.3    Malhotra, B.D.4
  • 97
    • 0242438615 scopus 로고    scopus 로고
    • Hydrogels of a conducting conjugated polymer as 3-D enzyme electrode
    • Asberg, P.; Inganas, O. Hydrogels of a conducting conjugated polymer as 3-D enzyme electrode. Biosens. Bioelectron. 2003, 19, 199-207.
    • (2003) Biosens. Bioelectron , vol.19 , pp. 199-207
    • Asberg, P.1    Inganas, O.2
  • 98
    • 23744439381 scopus 로고    scopus 로고
    • Chemically Polymerized Polyaniline Films for the Mass-Production of Biosensor Devices
    • Grennan, K.; Killard, AJ.; Smyth, M. R. Chemically Polymerized Polyaniline Films for the Mass-Production of Biosensor Devices. Electroanalysis 2005, 17, 1360-1369.
    • (2005) Electroanalysis , vol.17 , pp. 1360-1369
    • Grennan, K.1    Killard, A.J.2    Smyth, M.R.3
  • 100
    • 0036558189 scopus 로고    scopus 로고
    • A method to construct third generation Horseradish peroxidase biosensor: Self assembling gold nanoparticles to three dimensional sol-gel network
    • Jia, J.; Wang, B.; Wu, A.; Cheng, G.; Li, Z.; Dong, S. A method to construct third generation Horseradish peroxidase biosensor: Self assembling gold nanoparticles to three dimensional sol-gel network. Anal. Chem. 2002, 74, 2217-2223.
    • (2002) Anal. Chem , vol.74 , pp. 2217-2223
    • Jia, J.1    Wang, B.2    Wu, A.3    Cheng, G.4    Li, Z.5    Dong, S.6
  • 102
    • 4043167652 scopus 로고    scopus 로고
    • Electrochemistry and scanning electron microscopy of polyaniline/peroxidase-based biosensor
    • Mathebe, N.G.R.; Morrin, A.; Iwuoha, E.I. Electrochemistry and scanning electron microscopy of polyaniline/peroxidase-based biosensor. Talanta 2005, 64, 115-120.
    • (2005) Talanta , vol.64 , pp. 115-120
    • Mathebe, N.G.R.1    Morrin, A.2    Iwuoha, E.I.3
  • 103
    • 0036134835 scopus 로고    scopus 로고
    • Polypyrrole-hydrogel composites for the construction of clinically important biosensors
    • Brahim, S.; Narinesinh, D.; Gueseppi-Elie, A. Polypyrrole-hydrogel composites for the construction of clinically important biosensors. Biosens. Bioelectron. 2002, 17, 53-59.
    • (2002) Biosens. Bioelectron , vol.17 , pp. 53-59
    • Brahim, S.1    Narinesinh, D.2    Gueseppi-Elie, A.3
  • 105
    • 0142031171 scopus 로고    scopus 로고
    • A permselective biotinylated polydicarbazole film for the fabrication of amperometric enzyme electrodes
    • Cosnier, S.; Pellec, A. L.; Marks, R.S.; Perie, K.; Lellouche, J. -P. A permselective biotinylated polydicarbazole film for the fabrication of amperometric enzyme electrodes. Electrochem. Commun. 2003, 5, 973-977.
    • (2003) Electrochem. Commun , vol.5 , pp. 973-977
    • Cosnier, S.1    Pellec, A.L.2    Marks, R.S.3    Perie, K.4    Lellouche, J.-P.5
  • 106
    • 9944246431 scopus 로고    scopus 로고
    • Langer, JJ.; Filipiak, M.; J. Kecinska, J.; Jasnowska, J.; Wlodareczak, J.; Buladowski, B. Polyaniline biosensor for choline determination. Surf. Sci. 2004, 573, 140-145.
    • Langer, JJ.; Filipiak, M.; J. Kecinska, J.; Jasnowska, J.; Wlodareczak, J.; Buladowski, B. Polyaniline biosensor for choline determination. Surf. Sci. 2004, 573, 140-145.
  • 107
    • 27644572660 scopus 로고    scopus 로고
    • Amperometric biosensor for choline based on layerby-layer assembled functionalized carbon nanotube and polyaniline multilayer film
    • Qu, F.; Yang, M.; Jiang, J.; Shen, J.; Yu, R. Amperometric biosensor for choline based on layerby-layer assembled functionalized carbon nanotube and polyaniline multilayer film. Anal. Biochem. 2005, 344, 108-114.
    • (2005) Anal. Biochem , vol.344 , pp. 108-114
    • Qu, F.1    Yang, M.2    Jiang, J.3    Shen, J.4    Yu, R.5
  • 108
    • 0030042881 scopus 로고    scopus 로고
    • E. Gizeli, E.; Lowe, C.R. Immunosensors. Curr. Opin. Biotechnol. 1996, 7, 66-71.
    • E. Gizeli, E.; Lowe, C.R. Immunosensors. Curr. Opin. Biotechnol. 1996, 7, 66-71.
  • 109
    • 0030636256 scopus 로고    scopus 로고
    • McNeil, C. J.; Athey, D.; Renneberg, R. Immunosensors for Clinical Diagnosis, In: Frontiers in Biosensorics U. Practical Applications, Scheller, F.W.; Schubert, F. Fedowitz, J. Eds., Basel: Birkhauser Verlag, 1997; 17- 25.
    • McNeil, C. J.; Athey, D.; Renneberg, R. Immunosensors for Clinical Diagnosis, In: Frontiers in Biosensorics U. Practical Applications, Scheller, F.W.; Schubert, F. Fedowitz, J. Eds., Basel: Birkhauser Verlag, 1997; 17- 25.
  • 110
    • 0035161282 scopus 로고    scopus 로고
    • Immunosesnors-principles and applications to clinical chemistry
    • Luppa, P. B.; Sokoll, L. J.; Chan, D. W. Immunosesnors-principles and applications to clinical chemistry. Clinica Chimica Acta 2001, 314, 1-26.
    • (2001) Clinica Chimica Acta , vol.314 , pp. 1-26
    • Luppa, P.B.1    Sokoll, L.J.2    Chan, D.W.3
  • 111
    • 0034049997 scopus 로고    scopus 로고
    • Principles of affinity-based biosensors
    • Rogers, K. R. Principles of affinity-based biosensors. Mol. Biotechnol. 2000, 14, 109-129.
    • (2000) Mol. Biotechnol , vol.14 , pp. 109-129
    • Rogers, K.R.1
  • 112
    • 0028312216 scopus 로고
    • Immunosensors for clinical analysis
    • Aizawa, M. Immunosensors for clinical analysis. Adv. Clin. Chem. 1994, 31, 247-275.
    • (1994) Adv. Clin. Chem , vol.31 , pp. 247-275
    • Aizawa, M.1
  • 113
    • 0037402508 scopus 로고    scopus 로고
    • Disposable amperometric immunosensor system for rabbit IgG using a conducting polymer modified screen-printed electrode
    • Darain, F.; Park, S.-U.; Shim, Y.-B. Disposable amperometric immunosensor system for rabbit IgG using a conducting polymer modified screen-printed electrode. Biosens. Bioelectron. 2003, 18, 773-780.
    • (2003) Biosens. Bioelectron , vol.18 , pp. 773-780
    • Darain, F.1    Park, S.-U.2    Shim, Y.-B.3
  • 114
    • 1642280987 scopus 로고    scopus 로고
    • Development of an immunosensor for the detection of vitellogenin using impedance spectroscopy
    • Darain, F.; Park, D.S.; Park, J. S.; Shim, Y.-B. Development of an immunosensor for the detection of vitellogenin using impedance spectroscopy. Biosnes. Bioelectron. 2004, 19, 1245-1252.
    • (2004) Biosnes. Bioelectron , vol.19 , pp. 1245-1252
    • Darain, F.1    Park, D.S.2    Park, J.S.3    Shim, Y.-B.4
  • 115
    • 12844250780 scopus 로고    scopus 로고
    • Darain, F.; Park, D.-S.; Park, J.-S.; Chang S.-C;. Shim, Y.-B. A separation-free amperometric immunosensor for vitellogenin based on screen-printed carbon arrays modified with a conductive polymer. Biosens. Bioelectron. 2005, 20, 1780-1787.
    • Darain, F.; Park, D.-S.; Park, J.-S.; Chang S.-C;. Shim, Y.-B. A separation-free amperometric immunosensor for vitellogenin based on screen-printed carbon arrays modified with a conductive polymer. Biosens. Bioelectron. 2005, 20, 1780-1787.
  • 116
    • 7444225189 scopus 로고    scopus 로고
    • Development of a new and simple method for the detection of histdine-tagged proteins
    • Darain, F.; Ban, C.; Shim, Y. -B. "Development of a new and simple method for the detection of histdine-tagged proteins. Biosens. Bioelectron. 2004, 20, 857-863.
    • (2004) Biosens. Bioelectron , vol.20 , pp. 857-863
    • Darain, F.1    Ban, C.2    Shim, Y.-B.3
  • 117
    • 33947582815 scopus 로고    scopus 로고
    • An impedimetric immunosensor for the label-free detection of bisphenol A
    • Rahman, M. A.; Shiddiky, M. J. A.; Park, J.-S.; Shim, Y.-B. An impedimetric immunosensor for the label-free detection of bisphenol A. Biosens. Bioelectron. 2007, 22, 2464-2470.
    • (2007) Biosens. Bioelectron , vol.22 , pp. 2464-2470
    • Rahman, M.A.1    Shiddiky, M.J.A.2    Park, J.-S.3    Shim, Y.-B.4
  • 119
    • 0036404779 scopus 로고    scopus 로고
    • Application of polypyrrole for the creation of immunosensors
    • Ramanaviciene, A.; Ramanavicius, A. Application of polypyrrole for the creation of immunosensors. Crit. Rev. Anal. Chem. 2002, 32, 245-252.
    • (2002) Crit. Rev. Anal. Chem , vol.32 , pp. 245-252
    • Ramanaviciene, A.1    Ramanavicius, A.2
  • 121
    • 16444386398 scopus 로고    scopus 로고
    • A new label-free amperometric immunosensor for rubella vaccine
    • Zhang, L.; Yuan, R.; Huang, X.; Chai, Y.; Tang, D.; Cao, S. A new label-free amperometric immunosensor for rubella vaccine. Anal. Bioanal. Chem. 2005, 381, 1036-1040.
    • (2005) Anal. Bioanal. Chem , vol.381 , pp. 1036-1040
    • Zhang, L.1    Yuan, R.2    Huang, X.3    Chai, Y.4    Tang, D.5    Cao, S.6
  • 122
    • 11144244035 scopus 로고    scopus 로고
    • Polyaniline synthesis and its biosensor application
    • Tahir, Z. M.; Alcocilza, E. C.; Grooms, D. L. Polyaniline synthesis and its biosensor application. Biosens. Bioelectron. 2005, 20, 1690-1695.
    • (2005) Biosens. Bioelectron , vol.20 , pp. 1690-1695
    • Tahir, Z.M.1    Alcocilza, E.C.2    Grooms, D.L.3
  • 123
    • 0035975024 scopus 로고    scopus 로고
    • Electrochemical impedance spectroscopy as a platform for reagentless bioaffinity sensing
    • Lillie, G.; Payne, P.; Vadgama, P. Electrochemical impedance spectroscopy as a platform for reagentless bioaffinity sensing. Sens. Actuat. B 2001, 78, 249-256.
    • (2001) Sens. Actuat. B , vol.78 , pp. 249-256
    • Lillie, G.1    Payne, P.2    Vadgama, P.3
  • 125
    • 0035891257 scopus 로고    scopus 로고
    • Direct DNA hybridization detection based on the oligonucleotidefunctionalized conductive polymer
    • Lee, Y.-T.; Shim, Y.-B. Direct DNA hybridization detection based on the oligonucleotidefunctionalized conductive polymer. Anal. Chem. 2001, 73, 5629-5632.
    • (2001) Anal. Chem , vol.73 , pp. 5629-5632
    • Lee, Y.-T.1    Shim, Y.-B.2
  • 126
    • 3242738657 scopus 로고    scopus 로고
    • Detection of protein-DNA interaction with a DNA probe: Distinction between single-strand and double-strand DNA-protein interaction
    • Ban, C.; Chung, S.; Park, D.-S.; Shim, Y.-B. Detection of protein-DNA interaction with a DNA probe: distinction between single-strand and double-strand DNA-protein interaction, Nucleic Acids Research 2004, 32, e110-e117.
    • (2004) Nucleic Acids Research , vol.32
    • Ban, C.1    Chung, S.2    Park, D.-S.3    Shim, Y.-B.4
  • 127
    • 34548591359 scopus 로고    scopus 로고
    • Hydrazine-Catalyzed Ultrasensitive Detection of DNA and Proteins
    • Shiddiky, M. J. A.; Rahman, M. A.; Shim, Y.-B. Hydrazine-Catalyzed Ultrasensitive Detection of DNA and Proteins. Anal. Chem. 2007, 79, 6886-6890.
    • (2007) Anal. Chem , vol.79 , pp. 6886-6890
    • Shiddiky, M.J.A.1    Rahman, M.A.2    Shim, Y.-B.3
  • 128
    • 0035666591 scopus 로고    scopus 로고
    • Characterization of DNA Immobilized on Electrochemically Prepared Conducting Polypyrrole- Polyvinyl Sulfonate Films
    • Gambhir, A.; Gerard, M.; Ain, S. K. J.; Malhotra, B. D. Characterization of DNA Immobilized on Electrochemically Prepared Conducting Polypyrrole- Polyvinyl Sulfonate Films. Appl. Biochem. Biotech. 2001, 96, 303-309.
    • (2001) Appl. Biochem. Biotech , vol.96 , pp. 303-309
    • Gambhir, A.1    Gerard, M.2    Ain, S.K.J.3    Malhotra, B.D.4
  • 129
    • 0038094493 scopus 로고    scopus 로고
    • DNA hybridization electrochemical sensor using conducting polymer
    • Cha, J.; Han, J. I.; Choi, Y.; Yoon, D.S.; Who, K.; Lim, G. DNA hybridization electrochemical sensor using conducting polymer. Biosens. Bioelectron. 2003, 18, 1241-1247.
    • (2003) Biosens. Bioelectron , vol.18 , pp. 1241-1247
    • Cha, J.1    Han, J.I.2    Choi, Y.3    Yoon, D.S.4    Who, K.5    Lim, G.6
  • 130
    • 0037179934 scopus 로고    scopus 로고
    • Electrochemical biosensing of DNA hybridization by ferrocenyl groups functionalized polypyrrole
    • Youssoufi, H.K.; Makrouf, B. Electrochemical biosensing of DNA hybridization by ferrocenyl groups functionalized polypyrrole. Anal. Chim. Acta 2002, 469, 85-92.
    • (2002) Anal. Chim. Acta , vol.469 , pp. 85-92
    • Youssoufi, H.K.1    Makrouf, B.2
  • 131
    • 4544243073 scopus 로고    scopus 로고
    • Electrical contacting of glucose oxidase by DNA-templated polyaniline wires on surfaces
    • Shi, L.; Willner, I. Electrical contacting of glucose oxidase by DNA-templated polyaniline wires on surfaces. Electrochem. Commun. 2004, 6, 1057-1060.
    • (2004) Electrochem. Commun , vol.6 , pp. 1057-1060
    • Shi, L.1    Willner, I.2
  • 132
    • 9544243704 scopus 로고    scopus 로고
    • A biosensor monitoring DNA hybridization based on polyaniline intercalated graphite oxide nanocomposite
    • Wu, J.; Zhou,Y.; Li, X.; Liu, H.; Shen, G.; Yu, R. A biosensor monitoring DNA hybridization based on polyaniline intercalated graphite oxide nanocomposite. Sens. Actuat. B 2005, 104, 43-49.
    • (2005) Sens. Actuat. B , vol.104 , pp. 43-49
    • Wu, J.1    Zhou, Y.2    Li, X.3    Liu, H.4    Shen, G.5    Yu, R.6
  • 133
    • 33646102893 scopus 로고    scopus 로고
    • Electrochemically fabricated polyaniline nanowire-modified electrode for voltammetric detection of DNA hybridization
    • Zhu, N.; Chang, Z.; He, P.; Fang, Y. Electrochemically fabricated polyaniline nanowire-modified electrode for voltammetric detection of DNA hybridization. Electrochim. Acta 2006, 18, 3758-3762.
    • (2006) Electrochim. Acta , vol.18 , pp. 3758-3762
    • Zhu, N.1    Chang, Z.2    He, P.3    Fang, Y.4
  • 134
    • 16444372817 scopus 로고    scopus 로고
    • Immobilization of single-stranded DNA by self-assembled polymer on gold substrate for a DNA chip
    • _
    • Taira, S.; Yokoyama, K._Immobilization of single-stranded DNA by self-assembled polymer on gold substrate for a DNA chip. Biotechnol. Bioeng. 2005, 89, 835-838.
    • (2005) Biotechnol. Bioeng , vol.89 , pp. 835-838
    • Taira, S.1    Yokoyama, K.2
  • 135
    • 30944466110 scopus 로고    scopus 로고
    • Development and Characterization of Nickel-NTA-Polyaniline Modified Electrodes
    • Lori, J.; Morrin, A.; Killard, A.J.; Smyth, M.R. Development and Characterization of Nickel-NTA-Polyaniline Modified Electrodes. Electroanalysis 2006, 18, 77-81.
    • (2006) Electroanalysis , vol.18 , pp. 77-81
    • Lori, J.1    Morrin, A.2    Killard, A.J.3    Smyth, M.R.4
  • 136
    • 0035838839 scopus 로고    scopus 로고
    • Electronically conductive polymer grafted with oligonucleotides as electrosensors of DNA: Preliminary study of real time monitoring by in situ techniques
    • Lassalle, N.; Mailley, P.; Vieil, E.; Livache, T.; Roget, A.; Correia, J.P.;. Abrantes, L.M. Electronically conductive polymer grafted with oligonucleotides as electrosensors of DNA: Preliminary study of real time monitoring by in situ techniques. J. Electroanal. Chem. 2001, 509, 48-57.
    • (2001) J. Electroanal. Chem , vol.509 , pp. 48-57
    • Lassalle, N.1    Mailley, P.2    Vieil, E.3    Livache, T.4    Roget, A.5    Correia, J.P.6    Abrantes, L.M.7
  • 137
    • 85153307861 scopus 로고    scopus 로고
    • Cai, H.; Xu, Y.; He, P.-G.; Fang, Y.-Z. Indicator Free DNA Hybridization Detection by Impedance Measurement Based on the DNA-Doped Conducting Polymer Film Formed on the Carbon Nanotube Modified Electrode. Electroanalysis 2003, 15, 1864-1870.
    • Cai, H.; Xu, Y.; He, P.-G.; Fang, Y.-Z. Indicator Free DNA Hybridization Detection by Impedance Measurement Based on the DNA-Doped Conducting Polymer Film Formed on the Carbon Nanotube Modified Electrode. Electroanalysis 2003, 15, 1864-1870.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.