Volumn 31, Issue 8, 2004, Pages 2300-2312

Compensator thickness verification using an a-Si EPID

Author keywords

a Si EPID; Compensator QC; Scatter model; Transmission measurement

Indexed keywords

COMPUTERIZED TOMOGRAPHY; THICKNESS MEASUREMENT; TRANSMISSIONS; UNCERTAINTY ANALYSIS;

EID: 4043075129     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1767694     Document Type: Article
Times cited : (5)

References (16)
  • 1
    • 0001185624 scopus 로고
    • A compensator for variations in tissue thickness for high energy beams
    • F. Ellis, E. J. Hall, and R. Oliver, "A compensator for variations in tissue thickness for high energy beams," Br. J. Radiol. 32, 421-422 (1959).
    • (1959) Br. J. Radiol. , vol.32 , pp. 421-422
    • Ellis, F.1    Hall, E.J.2    Oliver, R.3
  • 2
    • 0019992678 scopus 로고
    • Compensating filters for high energy x rays
    • A. L. Boyer, "Compensating filters for high energy x rays," Med. Phys. 9, 429-433 (1982).
    • (1982) Med. Phys. , vol.9 , pp. 429-433
    • Boyer, A.L.1
  • 4
    • 0029929964 scopus 로고    scopus 로고
    • Verification of milled two-dimensional photon compensating filters using an electronic portal imaging device
    • D. A. Low, Z. Li, and E. E. Klein, "Verification of milled two-dimensional photon compensating filters using an electronic portal imaging device," Med. Phys. 23, 929-938 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 929-938
    • Low, D.A.1    Li, Z.2    Klein, E.E.3
  • 5
    • 0032798512 scopus 로고    scopus 로고
    • Verification of compensator thicknesses using a fluoroscopic electronic portal imaging device
    • K. L. Pasma, M. Kroonwijk, E. B. van Dieren, A. G. Visser, and B. J. M. Heijmen, "Verification of compensator thicknesses using a fluoroscopic electronic portal imaging device," Med. Phys. 26, 1524-1529 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 1524-1529
    • Pasma, K.L.1    Kroonwijk, M.2    Van Dieren, E.B.3    Visser, A.G.4    Heijmen, B.J.M.5
  • 6
    • 0038710306 scopus 로고    scopus 로고
    • Compensator quality control with an amorphous silicon EPID
    • G. V. Menon and R. S. Sloboda, "Compensator quality control with an amorphous silicon EPID," Med. Phys. 30, 1816-1824 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 1816-1824
    • Menon, G.V.1    Sloboda, R.S.2
  • 8
    • 1542711413 scopus 로고    scopus 로고
    • Quality assurance measurements of a-Si EPID performance
    • G. V. Menon and R. S. Sloboda, "Quality assurance measurements of a-Si EPID performance," Med. Dosim. 29, 11-17 (2004).
    • (2004) Med. Dosim. , vol.29 , pp. 11-17
    • Menon, G.V.1    Sloboda, R.S.2
  • 9
    • 0031045090 scopus 로고    scopus 로고
    • Linear accelerator photon beam quality at off-axis points
    • M. K. Yu, R. S. Sloboda, and B. Murray, "Linear accelerator photon beam quality at off-axis points," Med. Phys. 24, 233-239 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 233-239
    • Yu, M.K.1    Sloboda, R.S.2    Murray, B.3
  • 10
    • 0035180108 scopus 로고    scopus 로고
    • An iterative EPID calibration procedure for dosimetric verification that considers the EPID scattering factor
    • J. Chang, G. S. Mageras, C. C. Ling, and W. Lutz, "An iterative EPID calibration procedure for dosimetric verification that considers the EPID scattering factor," Med. Phys. 28, 2247-2257 (2001).
    • (2001) Med. Phys. , vol.28 , pp. 2247-2257
    • Chang, J.1    Mageras, G.S.2    Ling, C.C.3    Lutz, W.4
  • 11
    • 0010368351 scopus 로고
    • A note on the calculation of dose in x-ray fields
    • M. J. Day, "A note on the calculation of dose in x-ray fields," Br. J. Radiol. 23, 368-369 (1950).
    • (1950) Br. J. Radiol. , vol.23 , pp. 368-369
    • Day, M.J.1
  • 12
    • 0031045088 scopus 로고    scopus 로고
    • A convolution model to convert transmission dose images to exit dose distributions
    • R. Boellaard, M. van Herk, and B. J. Mijnheer, "A convolution model to convert transmission dose images to exit dose distributions," Med. Phys. 24, 189-199 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 189-199
    • Boellaard, R.1    Van Herk, M.2    Mijnheer, B.J.3
  • 13
    • 0030047716 scopus 로고    scopus 로고
    • Scattered radiation in portal images: A Monte Carlo simulation and a simple physical model
    • W. Swindell and P. M. Evans, "Scattered radiation in portal images: A Monte Carlo simulation and a simple physical model," Med. Phys. 23, 63-73 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 63-73
    • Swindell, W.1    Evans, P.M.2
  • 14
    • 0034023788 scopus 로고    scopus 로고
    • Direct measurement and analytical modeling of scatter in portal imaging
    • L. Spies, P. M. Evans, M. Partridge, V. N. Hansen, and T. Bortfeld, "Direct measurement and analytical modeling of scatter in portal imaging," Med. Phys. 27, 462-471 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 462-471
    • Spies, L.1    Evans, P.M.2    Partridge, M.3    Hansen, V.N.4    Bortfeld, T.5
  • 15
    • 33646667031 scopus 로고    scopus 로고
    • Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code
    • D. Sheikh-Bagheri and D. W. O. Rogers, "Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code," Med. Phys. 28, 2247-2257 (2001).
    • (2001) Med. Phys. , vol.28 , pp. 2247-2257
    • Sheikh-Bagheri, D.1    Rogers, D.W.O.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.