메뉴 건너뛰기




Volumn 18, Issue 2, 2008, Pages 197-208

Valvular heart disease: What does cardiovascular MRI add?

Author keywords

Magnetic resonance imaging; Valvular heart disease; Valvular regurgitation; Valvular stenosis

Indexed keywords

ARTICLE; DEVELOPED COUNTRY; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; DIAGNOSTIC PROCEDURE; DIAGNOSTIC VALUE; DOPPLER ECHOCARDIOGRAPHY; HEART CATHETERIZATION; HEART VALVE; HEART VALVE PROSTHESIS; HEART VALVE REGURGITATION; HEART VALVE STENOSIS; HEART VALVE SURGERY; HEART VENTRICLE FUNCTION; HUMAN; IMAGE QUALITY; ISCHEMIC HEART DISEASE; MORBIDITY; MORTALITY; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; VALVULAR HEART DISEASE;

EID: 39149128729     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00330-007-0731-x     Document Type: Article
Times cited : (36)

References (54)
  • 1
    • 0026091791 scopus 로고
    • Quantification of valvular regurgitation by Doppler echocardiography
    • Simpson IA, Sahn DJ (1991) Quantification of valvular regurgitation by Doppler echocardiography. Circulation 84(3 Suppl):I188-I192
    • (1991) Circulation , vol.84 , Issue.3 SUPPL.
    • Simpson, I.A.1    Sahn, D.J.2
  • 2
    • 0023180964 scopus 로고
    • When should Doppler-determined valve area be better than the Gorlin formula?: Variation in hydraulic constants in low flow states
    • Segal J, Lerner DJ, Miller DC, Mitchell RS, Alderman EA, Popp RL (1987) When should Doppler-determined valve area be better than the Gorlin formula?: Variation in hydraulic constants in low flow states. J Am Coll Cardiol 9:1294-1305
    • (1987) J Am Coll Cardiol , vol.9 , pp. 1294-1305
    • Segal, J.1    Lerner, D.J.2    Miller, D.C.3    Mitchell, R.S.4    Alderman, E.A.5    Popp, R.L.6
  • 7
    • 34247868104 scopus 로고    scopus 로고
    • Quantification of aortic valve stenosis in MRI - Comparison of steady-state free precession and fast low-angle shot sequences
    • Schlosser T, Malyar N, Jochims M, Breuckmann F, Hunold P, Bruder O, Erber R, Barkhausen J (2007) Quantification of aortic valve stenosis in MRI - comparison of steady-state free precession and fast low-angle shot sequences. Eur Radiol 17:1284-1290
    • (2007) Eur Radiol , vol.17 , pp. 1284-1290
    • Schlosser, T.1    Malyar, N.2    Jochims, M.3    Breuckmann, F.4    Hunold, P.5    Bruder, O.6    Erber, R.7    Barkhausen, J.8
  • 9
    • 0024423802 scopus 로고
    • Diagnostic accuracy and estimation of the severity of valvular regurgitation from the signal void on cine magnetic resonance images
    • Wagner S, Auffermann W, Buser P, Lim TH, Kircher B, Pflugfelder P, Higgins CB (1989) Diagnostic accuracy and estimation of the severity of valvular regurgitation from the signal void on cine magnetic resonance images. Am Heart J 118:760-767
    • (1989) Am Heart J , vol.118 , pp. 760-767
    • Wagner, S.1    Auffermann, W.2    Buser, P.3    Lim, T.H.4    Kircher, B.5    Pflugfelder, P.6    Higgins, C.B.7
  • 10
    • 0025157961 scopus 로고
    • Cine MR imaging of valvular heart disease: Display and imaging parameters affect the size of the signal void caused by valvular regurgitation
    • Suzuki J, Caputo GR, Kondo C, Higgins CB (1990) Cine MR imaging of valvular heart disease: Display and imaging parameters affect the size of the signal void caused by valvular regurgitation. AJR Am J Roentgenol 155:723-727
    • (1990) AJR Am J Roentgenol , vol.155 , pp. 723-727
    • Suzuki, J.1    Caputo, G.R.2    Kondo, C.3    Higgins, C.B.4
  • 11
    • 0035088021 scopus 로고    scopus 로고
    • MR evaluation of ventricular function: True fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: Feasibility study
    • Barkhausen J, Ruehm SG, Goyen M, Buck T, Laub G, Debatin JF (2001) MR evaluation of ventricular function: True fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: Feasibility study. Radiology 219:264-269
    • (2001) Radiology , vol.219 , pp. 264-269
    • Barkhausen, J.1    Ruehm, S.G.2    Goyen, M.3    Buck, T.4    Laub, G.5    Debatin, J.F.6
  • 13
    • 0036584937 scopus 로고    scopus 로고
    • Cardiovascular flow measurement with phase-contrast MR imaging: Basic facts and implementation
    • Lotz J, Meier C, Leppert A, Galanski M (2002) Cardiovascular flow measurement with phase-contrast MR imaging: Basic facts and implementation. Radiographics 22:651-671
    • (2002) Radiographics , vol.22 , pp. 651-671
    • Lotz, J.1    Meier, C.2    Leppert, A.3    Galanski, M.4
  • 16
    • 0025160052 scopus 로고
    • The application of phase shifts in NMR for flow measurements
    • Firmin DN, Nagler GL, Kilner PJ (1990) The application of phase shifts in NMR for flow measurements. Magn Reson Med 14:230-241
    • (1990) Magn Reson Med , vol.14 , pp. 230-241
    • Firmin, D.N.1    Nagler, G.L.2    Kilner, P.J.3
  • 17
    • 0034894364 scopus 로고    scopus 로고
    • Aortic and mitral regurgitation: Quantification using moving slice velocity mapping
    • Kozerke S, Schwitter J, Pedersen EM, Boesiger P (2000) Aortic and mitral regurgitation: Quantification using moving slice velocity mapping. J Magn Reson Imaging 14:106-112
    • (2000) J Magn Reson Imaging , vol.14 , pp. 106-112
    • Kozerke, S.1    Schwitter, J.2    Pedersen, E.M.3    Boesiger, P.4
  • 18
    • 0038560023 scopus 로고    scopus 로고
    • Evaluation of left ventricular volumes and ejection fraction using fast steady-state cine MR imaging: Comparison with left ventricular angiography
    • Ichikawa Y, Sakuma H, Kitagawa K, Ishida N, Takeda K, Uemura S, Motoyasu M, Nakano T, Nozaki A (2003) Evaluation of left ventricular volumes and ejection fraction using fast steady-state cine MR imaging: Comparison with left ventricular angiography. J Cardiovasc Magn Reson 5:333-342
    • (2003) J Cardiovasc Magn Reson , vol.5 , pp. 333-342
    • Ichikawa, Y.1    Sakuma, H.2    Kitagawa, K.3    Ishida, N.4    Takeda, K.5    Uemura, S.6    Motoyasu, M.7    Nakano, T.8    Nozaki, A.9
  • 19
    • 15944394042 scopus 로고    scopus 로고
    • Assessment of regional left ventricular function: Accuracy and reproducibility of positioning standard short-axis sections in cardiac. MR imaging
    • Messroghli DR, Bainbridge GJ, Alfakih K, Jones TR, Plein S, Ridgway JP, Sivananthan MU (2005) Assessment of regional left ventricular function: accuracy and reproducibility of positioning standard short-axis sections in cardiac MR imaging. Radiology 235:229-236
    • (2005) Radiology , vol.235 , pp. 229-236
    • Messroghli, D.R.1    Bainbridge, G.J.2    Alfakih, K.3    Jones, T.R.4    Plein, S.5    Ridgway, J.P.6    Sivananthan, M.U.7
  • 20
    • 14844302710 scopus 로고    scopus 로고
    • Magnetic resonance imaging of coronary arteries, the ischemic cascade, and myocardial infarction
    • Kaandorp TA, Lanb HJ, Bax JJ, van der Wall EE, de Ross A (2005) Magnetic resonance imaging of coronary arteries, the ischemic cascade, and myocardial infarction. Am Heart J 149:200-208
    • (2005) Am Heart J , vol.149 , pp. 200-208
    • Kaandorp, T.A.1    Lanb, H.J.2    Bax, J.J.3    van der Wall, E.E.4    de Ross, A.5
  • 21
    • 0037016057 scopus 로고    scopus 로고
    • Visualization of ventricular thrombi with contrast-enhanced magnetic resonance imaging in patients with ischemic heart disease
    • Mollet NR, Dymarkowski S, Volders W, Wathiong J, Herbots L, Rademakers FE, Bogaert J (2002) Visualization of ventricular thrombi with contrast-enhanced magnetic resonance imaging in patients with ischemic heart disease. Circulation 106:2873-2876
    • (2002) Circulation , vol.106 , pp. 2873-2876
    • Mollet, N.R.1    Dymarkowski, S.2    Volders, W.3    Wathiong, J.4    Herbots, L.5    Rademakers, F.E.6    Bogaert, J.7
  • 22
    • 0035490994 scopus 로고    scopus 로고
    • Difficulty in diagnosing double-chambered right ventricle in adults
    • Lascano ME, Schaad MS, Moodie DS, Murphy D Jr (2001) Difficulty in diagnosing double-chambered right ventricle in adults. Am J Cardiol 88:816-819
    • (2001) Am J Cardiol , vol.88 , pp. 816-819
    • Lascano, M.E.1    Schaad, M.S.2    Moodie, D.S.3    Murphy Jr., D.4
  • 28
    • 7044286097 scopus 로고    scopus 로고
    • Quantification of regurgitant fraction in mitral regurgitation by cardiovascular magnetic resonance: Comparison of techniques
    • Kon MW, Myerson SG, Moat NE, Pennell DJ (2004) Quantification of regurgitant fraction in mitral regurgitation by cardiovascular magnetic resonance: Comparison of techniques. J Heart Valve Dis 13:600-607
    • (2004) J Heart Valve Dis , vol.13 , pp. 600-607
    • Kon, M.W.1    Myerson, S.G.2    Moat, N.E.3    Pennell, D.J.4
  • 31
    • 0036642629 scopus 로고    scopus 로고
    • Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy
    • Grothues F, Smith GC, Moon JC, Bellenger NG, Collins P, Klein HU, Pennell DJ (2002) Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy. Am J Cardiol 90:29-34
    • (2002) Am J Cardiol , vol.90 , pp. 29-34
    • Grothues, F.1    Smith, G.C.2    Moon, J.C.3    Bellenger, N.G.4    Collins, P.5    Klein, H.U.6    Pennell, D.J.7
  • 34
    • 0027443677 scopus 로고
    • Pulmonary regurgitation in the late postoperative follow-up of tetralogy of Fallot. Volumetric quantitation by nuclear magnetic resonance velocity mapping
    • Rebergen SA, Chin JG, Ottenkamp J, van der Wall EE, de Roos A (1993) Pulmonary regurgitation in the late postoperative follow-up of tetralogy of Fallot. Volumetric quantitation by nuclear magnetic resonance velocity mapping. Circulation 88(5 Pt 1):2257-2266
    • (1993) Circulation , vol.88 , Issue.5 PART 1 , pp. 2257-2266
    • Rebergen, S.A.1    Chin, J.G.2    Ottenkamp, J.3    van der Wall, E.E.4    de Roos, A.5
  • 37
    • 0027426106 scopus 로고
    • Cine magnetic resonance imaging and color Doppler flow mapping displays of flow velocity, spatial acceleration, and jet formation: A comparative in vitro study
    • Simpson IA, Maciel BC, Moises V, Shandas R, Elias W, Valdes-Cruz L, Hesselink JR, Chung KJ, Sahn DJ (1993) Cine magnetic resonance imaging and color Doppler flow mapping displays of flow velocity, spatial acceleration, and jet formation: A comparative in vitro study. Am Heart J 126:1165-1174
    • (1993) Am Heart J , vol.126 , pp. 1165-1174
    • Simpson, I.A.1    Maciel, B.C.2    Moises, V.3    Shandas, R.4    Elias, W.5    Valdes-Cruz, L.6    Hesselink, J.R.7    Chung, K.J.8    Sahn, D.J.9
  • 38
    • 0023188068 scopus 로고
    • Changing aspects of the natural history of valvular aortic stenosis
    • Selzer A (1987) Changing aspects of the natural history of valvular aortic stenosis. N Engl J Med 317:91-98
    • (1987) N Engl J Med , vol.317 , pp. 91-98
    • Selzer, A.1
  • 39
    • 0024513041 scopus 로고
    • Factors affecting Doppler echocardiographic valve area assessment in aortic stenosis
    • Danielsen R, Nordrehaug JE, Vik-Mo H (1989) Factors affecting Doppler echocardiographic valve area assessment in aortic stenosis. Am J Cardiol 63:1107-1111
    • (1989) Am J Cardiol , vol.63 , pp. 1107-1111
    • Danielsen, R.1    Nordrehaug, J.E.2    Vik-Mo, H.3
  • 41
    • 0030740125 scopus 로고    scopus 로고
    • Planimetry of aortic valve area using multiplane transoesophageal echocardiography is not a reliable method for assessing severity of aortic stenosis
    • Bernard Y, Meneveau N, Vuillemenot A, Magnin D, Anguenot T, Schiele F, Bassand JP (1997) Planimetry of aortic valve area using multiplane transoesophageal echocardiography is not a reliable method for assessing severity of aortic stenosis. Heart 78:68-73
    • (1997) Heart , vol.78 , pp. 68-73
    • Bernard, Y.1    Meneveau, N.2    Vuillemenot, A.3    Magnin, D.4    Anguenot, T.5    Schiele, F.6    Bassand, J.P.7
  • 43
    • 50449114923 scopus 로고
    • Hydraulic formula for calculation of the area of the stenotic mitral valve, other cardiac valve and central circulatory shunts
    • Gorlin R (1951) Hydraulic formula for calculation of the area of the stenotic mitral valve, other cardiac valve and central circulatory shunts. Am Heart J 41:1-18
    • (1951) Am Heart J , vol.41 , pp. 1-18
    • Gorlin, R.1
  • 45
    • 3442899990 scopus 로고    scopus 로고
    • Evaluation of aortic stenosis by cardiovascular magnetic resonance imaging: Comparison with established routine clinical techniques
    • Kupfahl C, Honold M, Meinhardt G, Vogelsberg H, Wagner A, Mahrholdt H, Sechtem U (2004) Evaluation of aortic stenosis by cardiovascular magnetic resonance imaging: Comparison with established routine clinical techniques. Heart 90:893-901
    • (2004) Heart , vol.90 , pp. 893-901
    • Kupfahl, C.1    Honold, M.2    Meinhardt, G.3    Vogelsberg, H.4    Wagner, A.5    Mahrholdt, H.6    Sechtem, U.7
  • 46
    • 33746242239 scopus 로고    scopus 로고
    • Absolute assessment of aortic valve stenosis by planimetry using cardiovascular magnetic resonance imaging: Comparison with transesophageal echocardiography, transthoracic echocardiography, and cardiac catheterisation
    • Reant P, Lederlin M, Lafitte S, Serri K, Montaudon M, Corneloup O, Roudaut R, Laurent F (2006) Absolute assessment of aortic valve stenosis by planimetry using cardiovascular magnetic resonance imaging: comparison with transesophageal echocardiography, transthoracic echocardiography, and cardiac catheterisation. Eur J Radiol 59:276-283
    • (2006) Eur J Radiol , vol.59 , pp. 276-283
    • Reant, P.1    Lederlin, M.2    Lafitte, S.3    Serri, K.4    Montaudon, M.5    Corneloup, O.6    Roudaut, R.7    Laurent, F.8
  • 47
    • 0043128979 scopus 로고    scopus 로고
    • Magnetic resonance to assess the aortic valve area in aortic stenosis: How does it compare to current diagnostic standards?
    • John AS, Dill T, Brandt RR, Rau M, Ricken W, Bachmann G, Hamm CW (2003) Magnetic resonance to assess the aortic valve area in aortic stenosis: how does it compare to current diagnostic standards? J Am Coll Cardiol 42:519-526
    • (2003) J Am Coll Cardiol , vol.42 , pp. 519-526
    • John, A.S.1    Dill, T.2    Brandt, R.R.3    Rau, M.4    Ricken, W.5    Bachmann, G.6    Hamm, C.W.7
  • 48
    • 3242737619 scopus 로고    scopus 로고
    • Is it very too late to operate on the patient with valvular heart disease?
    • Carabello BA (2004) Is it very too late to operate on the patient with valvular heart disease? J Am Coll Cardiol 44:376-383
    • (2004) J Am Coll Cardiol , vol.44 , pp. 376-383
    • Carabello, B.A.1
  • 49
    • 0343765766 scopus 로고    scopus 로고
    • Simultaneous determination of aortic valve area by the Gorlin formula and by transesophageal echocardiography under different transvalvular flow conditions. Evidence that anatomic aortic valve area does not change with variations in flow in aortic stenosis
    • Tardif JC, Rodrigues AG, Hardy JF, Leclerc Y, Petitclerc R, Mongrain R, Mercier LA (1997) Simultaneous determination of aortic valve area by the Gorlin formula and by transesophageal echocardiography under different transvalvular flow conditions. Evidence that anatomic aortic valve area does not change with variations in flow in aortic stenosis. J Am Coll Cardiol 29:1296-1302
    • (1997) J Am Coll Cardiol , vol.29 , pp. 1296-1302
    • Tardif, J.C.1    Rodrigues, A.G.2    Hardy, J.F.3    Leclerc, Y.4    Petitclerc, R.5    Mongrain, R.6    Mercier, L.A.7
  • 50
    • 0037132601 scopus 로고    scopus 로고
    • Left ventricular remodeling early after aortic valve replacement: Differential effects on diastolic function in aortic valve stenosis and aortic regurgitation
    • Lamb HJ, Beyerbracht HP, de Roos A, van der Laarse A, Vliegen HW, Leujes F, Bax JJ, Van der Wall EE (2002) Left ventricular remodeling early after aortic valve replacement: Differential effects on diastolic function in aortic valve stenosis and aortic regurgitation. J Am Coll Cardiol 40:2182-2188
    • (2002) J Am Coll Cardiol , vol.40 , pp. 2182-2188
    • Lamb, H.J.1    Beyerbracht, H.P.2    de Roos, A.3    van der Laarse, A.4    Vliegen, H.W.5    Leujes, F.6    Bax, J.J.7    Van der Wall, E.E.8
  • 51
    • 4143152698 scopus 로고    scopus 로고
    • MR procedures: Biologic effects, safety, and patient care
    • Shellock FG, Crues JV (2004) MR procedures: Biologic effects, safety, and patient care. Radiology 232:635-652
    • (2004) Radiology , vol.232 , pp. 635-652
    • Shellock, F.G.1    Crues, J.V.2
  • 52
    • 22944443636 scopus 로고    scopus 로고
    • Assessment of magnetic field (4.7 T) induced forces on prosthetic heart valves and annuloplasty rings
    • Edwards MB, Ordidge RJ, Hand JW, Taylor KM, Young IR (2005) Assessment of magnetic field (4.7 T) induced forces on prosthetic heart valves and annuloplasty rings. J Magn Reson Imaging 22:311-317
    • (2005) J Magn Reson Imaging , vol.22 , pp. 311-317
    • Edwards, M.B.1    Ordidge, R.J.2    Hand, J.W.3    Taylor, K.M.4    Young, I.R.5
  • 53
    • 0026688859 scopus 로고
    • Regurgitant flow in cardiac valve prostheses: Diagnostic value of gradient echo nuclear magnetic resonance imaging in reference to transesophageal two-dimensional color Doppler echocardiography
    • Deutsch HJ, Bachmann R, Sechtem U, Curtius JM, Jungehulsing M, Schicha H, Hilger HH (1992) Regurgitant flow in cardiac valve prostheses: diagnostic value of gradient echo nuclear magnetic resonance imaging in reference to transesophageal two-dimensional color Doppler echocardiography. J Am Coll Cardiol 19:1500-1507
    • (1992) J Am Coll Cardiol , vol.19 , pp. 1500-1507
    • Deutsch, H.J.1    Bachmann, R.2    Sechtem, U.3    Curtius, J.M.4    Jungehulsing, M.5    Schicha, H.6    Hilger, H.H.7
  • 54
    • 0030040934 scopus 로고    scopus 로고
    • Comparison of magnetic resonance imaging and Laser Doppler Anemometry velocity measurements downstream of replacement heart valves: Implications for in vivo assessment of prosthetic valve function
    • Fontaine AA, Heinrich RS, Walker PG, Pedersen EM, Scheidegger MB, Boesiger P, Walton SP, Yoganathan AP (1996) Comparison of magnetic resonance imaging and Laser Doppler Anemometry velocity measurements downstream of replacement heart valves: Implications for in vivo assessment of prosthetic valve function. J Heart Valve Dis 5:66-73
    • (1996) J Heart Valve Dis , vol.5 , pp. 66-73
    • Fontaine, A.A.1    Heinrich, R.S.2    Walker, P.G.3    Pedersen, E.M.4    Scheidegger, M.B.5    Boesiger, P.6    Walton, S.P.7    Yoganathan, A.P.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.