메뉴 건너뛰기




Volumn 105, Issue 2, 2008, Pages 239-244

Effect of ambient light and bit depth of digital radiograph on observer performance in determination of endodontic file positioning

Author keywords

[No Author keywords available]

Indexed keywords

ANALYSIS OF VARIANCE; ARTICLE; COMPARATIVE STUDY; DENTAL EQUIPMENT; ENDODONTICS; HOSPITAL INFORMATION SYSTEM; HUMAN; ILLUMINATION; INSTRUMENTATION; METHODOLOGY; OBSERVER VARIATION; ODONTOMETRY; PREMOLAR TOOTH; RADIOGRAPHY; REPRODUCIBILITY; ROC CURVE; TOOTH PULP; TOOTH RADIOGRAPHY;

EID: 38949167562     PISSN: 10792104     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.tripleo.2007.02.002     Document Type: Article
Times cited : (30)

References (29)
  • 2
    • 0029242145 scopus 로고
    • Direct digital radiography in the dental office
    • Wenzel A., and Grondahl H.G. Direct digital radiography in the dental office. Int Dent J 45 (1995) 27-34
    • (1995) Int Dent J , vol.45 , pp. 27-34
    • Wenzel, A.1    Grondahl, H.G.2
  • 5
    • 0027639921 scopus 로고
    • Imaging: new versus traditional technological aids
    • Sanderink G.C. Imaging: new versus traditional technological aids. Int Dent J 43 (1993) 335-342
    • (1993) Int Dent J , vol.43 , pp. 335-342
    • Sanderink, G.C.1
  • 7
    • 0028477798 scopus 로고
    • Radiographic determination of canal length: direct digital radiography versus conventional radiography
    • Hedrick R.T., Dove S.B., Peters D.D., and Mcdavid W.D. Radiographic determination of canal length: direct digital radiography versus conventional radiography. J Endod 20 (1994) 320-326
    • (1994) J Endod , vol.20 , pp. 320-326
    • Hedrick, R.T.1    Dove, S.B.2    Peters, D.D.3    Mcdavid, W.D.4
  • 8
    • 0036356987 scopus 로고    scopus 로고
    • Canal length evaluation of curved canals by direct digital or conventional radiography
    • Mentes A., and Gencoglu N. Canal length evaluation of curved canals by direct digital or conventional radiography. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 93 (2002) 88-91
    • (2002) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.93 , pp. 88-91
    • Mentes, A.1    Gencoglu, N.2
  • 9
    • 0029173920 scopus 로고
    • Comparison of radiovisiography with radiographic film in root length determination
    • Ong E.Y., and Pitt Ford T.R. Comparison of radiovisiography with radiographic film in root length determination. Int Endod J 28 (1995) 25-29
    • (1995) Int Endod J , vol.28 , pp. 25-29
    • Ong, E.Y.1    Pitt Ford, T.R.2
  • 14
    • 0035345373 scopus 로고    scopus 로고
    • Cathode ray tube quality control and acceptance testing program: initial results for clinical PACS displays
    • Groth D.S., Bernatz S.N., Fetterly K.A., and Hangiandreou N.J. Cathode ray tube quality control and acceptance testing program: initial results for clinical PACS displays. Radiographics 21 (2001) 719-732
    • (2001) Radiographics , vol.21 , pp. 719-732
    • Groth, D.S.1    Bernatz, S.N.2    Fetterly, K.A.3    Hangiandreou, N.J.4
  • 15
    • 0034068352 scopus 로고    scopus 로고
    • Effects of luminance and resolution on observer performance with chest radiographs
    • Herron J.M., Bender T.M., Campbell W.L., Sumkin J.H., Rockette H.E., and Gur D. Effects of luminance and resolution on observer performance with chest radiographs. Radiology 215 (2000) 169-174
    • (2000) Radiology , vol.215 , pp. 169-174
    • Herron, J.M.1    Bender, T.M.2    Campbell, W.L.3    Sumkin, J.H.4    Rockette, H.E.5    Gur, D.6
  • 16
    • 0037029058 scopus 로고    scopus 로고
    • CRT diagnosis of pulmonary disease: influence of monitor brightness and room illuminance on observer performance
    • Ishihara S., Shimamoto K., Ikeda M., Kato K., Mori Y., Ishiguchi T., et al. CRT diagnosis of pulmonary disease: influence of monitor brightness and room illuminance on observer performance. Comput Med Imaging Graph 26 (2002) 181-185
    • (2002) Comput Med Imaging Graph , vol.26 , pp. 181-185
    • Ishihara, S.1    Shimamoto, K.2    Ikeda, M.3    Kato, K.4    Mori, Y.5    Ishiguchi, T.6
  • 17
    • 0031961309 scopus 로고    scopus 로고
    • Subtle pulmonary abnormalities: detection on monitors with varying spatial resolutions and maximum luminance levels compared with detection on storage phosphor radiographic hard copies
    • Otto D., Bernhardt T.M., Rapp-Bernhardt U., Ludwig K., Kastner A., Liehr U.B., et al. Subtle pulmonary abnormalities: detection on monitors with varying spatial resolutions and maximum luminance levels compared with detection on storage phosphor radiographic hard copies. Radiology 207 (1998) 237-242
    • (1998) Radiology , vol.207 , pp. 237-242
    • Otto, D.1    Bernhardt, T.M.2    Rapp-Bernhardt, U.3    Ludwig, K.4    Kastner, A.5    Liehr, U.B.6
  • 18
    • 0033277470 scopus 로고    scopus 로고
    • Influence film and monitor display luminance on observer performance and visual search
    • Krupinski E., Roehrig H., and Furukawa T. Influence film and monitor display luminance on observer performance and visual search. Acad Radiol 6 (1999) 411-418
    • (1999) Acad Radiol , vol.6 , pp. 411-418
    • Krupinski, E.1    Roehrig, H.2    Furukawa, T.3
  • 20
    • 0018368090 scopus 로고
    • Radiography of the periapical region as a diagnostic aid. II. Diagnosis of pulp-related changes
    • Brynolf I. Radiography of the periapical region as a diagnostic aid. II. Diagnosis of pulp-related changes. Dent Radiogr Photogr 52 (1979) 25-47
    • (1979) Dent Radiogr Photogr , vol.52 , pp. 25-47
    • Brynolf, I.1
  • 21
    • 0019938368 scopus 로고
    • The influence of ambient and viewbox light upon visual detection of low-contrast targets in a radiograph
    • Alter A.J., Kargas G.A., Kargas S.A., Cameron J.R., and McDermott J.C. The influence of ambient and viewbox light upon visual detection of low-contrast targets in a radiograph. Invest Radiol 17 (1982) 402-406
    • (1982) Invest Radiol , vol.17 , pp. 402-406
    • Alter, A.J.1    Kargas, G.A.2    Kargas, S.A.3    Cameron, J.R.4    McDermott, J.C.5
  • 22
    • 4143115534 scopus 로고    scopus 로고
    • Effect of monitor luminance and ambient light on observer performance in soft-copy reading of digital chest radiographs
    • Goo J.M., Choi J.Y., Im J.G., Lee H.J., Chung M.J., Han D., et al. Effect of monitor luminance and ambient light on observer performance in soft-copy reading of digital chest radiographs. Radiology 232 (2004) 762-766
    • (2004) Radiology , vol.232 , pp. 762-766
    • Goo, J.M.1    Choi, J.Y.2    Im, J.G.3    Lee, H.J.4    Chung, M.J.5    Han, D.6
  • 24
    • 0026952192 scopus 로고
    • Comparison of three imaging techniques for assessing endodontic working length
    • Griffiths B.M., Brown J.E., Hyatt A.T., and Linney A.D. Comparison of three imaging techniques for assessing endodontic working length. Int Endod J 25 (1992) 279-287
    • (1992) Int Endod J , vol.25 , pp. 279-287
    • Griffiths, B.M.1    Brown, J.E.2    Hyatt, A.T.3    Linney, A.D.4
  • 25
    • 0026215486 scopus 로고
    • Radiovisiography for length estimation in root canal treatment: an in-vitro comparison with conventional radiography
    • Shearer A.C., Horner K., and Wilson N.H. Radiovisiography for length estimation in root canal treatment: an in-vitro comparison with conventional radiography. Int Endod J 24 (1991) 233-239
    • (1991) Int Endod J , vol.24 , pp. 233-239
    • Shearer, A.C.1    Horner, K.2    Wilson, N.H.3
  • 27
    • 0028471403 scopus 로고
    • Image quality of direct digital intraoral x-ray sensors in assessing root canal length. The Radiovisiography, Visualix/Vixa, Sens-a-Ray, and Flash Dent systems compared with Ektaspeed films
    • Sanderink G.C., Huiskens R., van der Stelt P.F., Welander U.S., and Stheeman S.E. Image quality of direct digital intraoral x-ray sensors in assessing root canal length. The Radiovisiography, Visualix/Vixa, Sens-a-Ray, and Flash Dent systems compared with Ektaspeed films. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 78 (1994) 125-132
    • (1994) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.78 , pp. 125-132
    • Sanderink, G.C.1    Huiskens, R.2    van der Stelt, P.F.3    Welander, U.S.4    Stheeman, S.E.5
  • 28
    • 44449134721 scopus 로고    scopus 로고
    • Comparison of three digital radiographic imaging systems for the visibility of endodontic files
    • Park J.W., Kim E.K., and Han W.J. Comparison of three digital radiographic imaging systems for the visibility of endodontic files. Korean J Oral Maxillofac Radiol 34 (2004) 145-150
    • (2004) Korean J Oral Maxillofac Radiol , vol.34 , pp. 145-150
    • Park, J.W.1    Kim, E.K.2    Han, W.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.