메뉴 건너뛰기




Volumn 4, Issue 2, 2008, Pages 296-304

Mechanical load-assisted dissolution of metallic implant surfaces: Influence of contact loads and surface stress state

Author keywords

Biocompatibility; Mechanical characterization; Metal; Surface characterization

Indexed keywords

ATOMIC FORCE MICROSCOPY; BIOCOMPATIBILITY; CHROMIUM ALLOYS; CREVICE CORROSION; LOADS (FORCES); MOLYBDENUM ALLOYS; TENSILE STRESS;

EID: 38949149286     PISSN: 17427061     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.actbio.2007.08.004     Document Type: Article
Times cited : (14)

References (42)
  • 1
    • 0037024102 scopus 로고    scopus 로고
    • Concentration- and composition-dependent effects of metal ions on human MG-63 osteoblasts
    • Hallab N.J., Vermes C., Messina C., Roebuck K.A., Glant T.T., and Jacobs J.J. Concentration- and composition-dependent effects of metal ions on human MG-63 osteoblasts. J Biomed Mater Res 60 3 (2002) 420-433
    • (2002) J Biomed Mater Res , vol.60 , Issue.3 , pp. 420-433
    • Hallab, N.J.1    Vermes, C.2    Messina, C.3    Roebuck, K.A.4    Glant, T.T.5    Jacobs, J.J.6
  • 2
    • 1842581502 scopus 로고    scopus 로고
    • Mechanisms of failure of total hip replacements - lessons learned from retrieval studies
    • Hirakawa K., Jacobs J.J., Urban R., and Saito T. Mechanisms of failure of total hip replacements - lessons learned from retrieval studies. Clin Orthop Relat Res 420 (2004) 10-17
    • (2004) Clin Orthop Relat Res , Issue.420 , pp. 10-17
    • Hirakawa, K.1    Jacobs, J.J.2    Urban, R.3    Saito, T.4
  • 3
    • 0036956489 scopus 로고    scopus 로고
    • Nanotribology of CoCr-UHMWPE TJR prosthesis using atomic force microscopy
    • Ho S.P., Carpick R.W., Boland T., and LaBerge M. Nanotribology of CoCr-UHMWPE TJR prosthesis using atomic force microscopy. Wear 253 11-12 (2002) 1145-1155
    • (2002) Wear , vol.253 , Issue.11-12 , pp. 1145-1155
    • Ho, S.P.1    Carpick, R.W.2    Boland, T.3    LaBerge, M.4
  • 6
    • 0036139730 scopus 로고    scopus 로고
    • Synergistic effect of particles and cyclic pressure on cytokine production in human monocyte/macrophages: proposed role in periprosthetic osteolysis
    • McEvoy A., Jeyam M., Ferrier G., Evans C.E., and Andrew J.G. Synergistic effect of particles and cyclic pressure on cytokine production in human monocyte/macrophages: proposed role in periprosthetic osteolysis. Bone 30 1 (2002) 171-177
    • (2002) Bone , vol.30 , Issue.1 , pp. 171-177
    • McEvoy, A.1    Jeyam, M.2    Ferrier, G.3    Evans, C.E.4    Andrew, J.G.5
  • 7
    • 0030267997 scopus 로고    scopus 로고
    • Wear Particles of polyethylene in biologicalsystems
    • Mosleh M., and Su N. Wear Particles of polyethylene in biologicalsystems. Tribol Trans 39 (1996) 843-848
    • (1996) Tribol Trans , vol.39 , pp. 843-848
    • Mosleh, M.1    Su, N.2
  • 8
    • 0348048879 scopus 로고    scopus 로고
    • Gigantic popliteal synovial cyst caused by wear particles after total knee arthroplasty
    • Niki Y., Matsumoto H., Otani T., Yoshimine F., Inokuchi W., and Morisue H. Gigantic popliteal synovial cyst caused by wear particles after total knee arthroplasty. J Orthop 18 8 (2003) 1071-1075
    • (2003) J Orthop , vol.18 , Issue.8 , pp. 1071-1075
    • Niki, Y.1    Matsumoto, H.2    Otani, T.3    Yoshimine, F.4    Inokuchi, W.5    Morisue, H.6
  • 9
    • 0035387564 scopus 로고    scopus 로고
    • Wear reduction effect on ultra-high-molecular-weight polyethylene by application of hard coatings and ion implantation on cobalt chromium alloy, as measured in a knee wear simulation machine
    • Onate J.I., Comin M., Braceras I., Garcia A., Viviente J.L., Brizuela M., et al. Wear reduction effect on ultra-high-molecular-weight polyethylene by application of hard coatings and ion implantation on cobalt chromium alloy, as measured in a knee wear simulation machine. Surf Coat Technol 142-144 (2001) 1056-1062
    • (2001) Surf Coat Technol , vol.142-144 , pp. 1056-1062
    • Onate, J.I.1    Comin, M.2    Braceras, I.3    Garcia, A.4    Viviente, J.L.5    Brizuela, M.6
  • 10
    • 0035069544 scopus 로고    scopus 로고
    • Correlation of wear debris-induced osteolysis and revision with volumetric wear-rates of polyethylene - a survey of 8 reports in the literature
    • Oparaugo P.C., Clarke I.C., Malchau H., and Herberts P. Correlation of wear debris-induced osteolysis and revision with volumetric wear-rates of polyethylene - a survey of 8 reports in the literature. Acta Orthop Scand 72 1 (2001) 22-28
    • (2001) Acta Orthop Scand , vol.72 , Issue.1 , pp. 22-28
    • Oparaugo, P.C.1    Clarke, I.C.2    Malchau, H.3    Herberts, P.4
  • 12
    • 38949182724 scopus 로고    scopus 로고
    • Aseptic loosening of implants
    • Willert H.-G., and Buchhorn G.H. Aseptic loosening of implants. Nova Acta Leopold 84 321 (2001) 51-62
    • (2001) Nova Acta Leopold , vol.84 , Issue.321 , pp. 51-62
    • Willert, H.-G.1    Buchhorn, G.H.2
  • 13
    • 0038613870 scopus 로고    scopus 로고
    • In vitro analysis of the wear, wear debris and biological activity of surface-engineered coatings for use in metal-on-metal total hip replacements
    • Williams S., Tipper J.L., Ingham E., Stone M.H., and Fisher J. In vitro analysis of the wear, wear debris and biological activity of surface-engineered coatings for use in metal-on-metal total hip replacements. Proc Inst Mech Eng Part H: J Eng Med 217 (2003) 55-163
    • (2003) Proc Inst Mech Eng Part H: J Eng Med , vol.217 , pp. 55-163
    • Williams, S.1    Tipper, J.L.2    Ingham, E.3    Stone, M.H.4    Fisher, J.5
  • 14
    • 38949113421 scopus 로고    scopus 로고
    • The characterization of polyethylene and metal wear particles, retrieved from tissue adjacent to failed total joint replacements using a novel extraction technique
    • New Biomedical Materials
    • Yamac T., Kobayashi A., Bonfield W., and Revell P.A. The characterization of polyethylene and metal wear particles, retrieved from tissue adjacent to failed total joint replacements using a novel extraction technique. Biomed Health Res 16 (1998) 86-90 New Biomedical Materials
    • (1998) Biomed Health Res , vol.16 , pp. 86-90
    • Yamac, T.1    Kobayashi, A.2    Bonfield, W.3    Revell, P.A.4
  • 15
    • 0032831927 scopus 로고    scopus 로고
    • Early osteolysis following total hip arthroplasty with use of a hylamer liner in combination with a modular ceramic femoral head - a case report
    • Vaughn B.K., Dameron T.B., Bauer T.W., Mochida Y., Akisue T., and Eberle R.W. Early osteolysis following total hip arthroplasty with use of a hylamer liner in combination with a modular ceramic femoral head - a case report. J Bone Joint Surg Am Vol 81A 10 (1999) 1446-1449
    • (1999) J Bone Joint Surg Am Vol , vol.81 A , Issue.10 , pp. 1446-1449
    • Vaughn, B.K.1    Dameron, T.B.2    Bauer, T.W.3    Mochida, Y.4    Akisue, T.5    Eberle, R.W.6
  • 16
    • 0034117155 scopus 로고    scopus 로고
    • Dissemination of wear particles to the liver, spleen, and abdominal lymph nodes of patients with hip or knee replacement
    • Urban R.M., Jacobs J.J., Tomlinson M.J., Gavrilovic J., Black J., and Peoc'h M. Dissemination of wear particles to the liver, spleen, and abdominal lymph nodes of patients with hip or knee replacement. J Bone Joint Surg Am Vol 82A 4 (2000) 457-477
    • (2000) J Bone Joint Surg Am Vol , vol.82 A , Issue.4 , pp. 457-477
    • Urban, R.M.1    Jacobs, J.J.2    Tomlinson, M.J.3    Gavrilovic, J.4    Black, J.5    Peoc'h, M.6
  • 17
    • 0038542978 scopus 로고    scopus 로고
    • Orthopedic implant fretting corrosion
    • Hallab N.J., and Jacobs J.J. Orthopedic implant fretting corrosion. Corros Rev 21 2-3 (2003) 183-213
    • (2003) Corros Rev , vol.21 , Issue.2-3 , pp. 183-213
    • Hallab, N.J.1    Jacobs, J.J.2
  • 19
    • 0346124165 scopus 로고    scopus 로고
    • Size, shape, and composition of wear particles from metal-metal hip simulator testing: effects of alloy and number of loading cycles
    • Catelas I., Bobyn J.D., Medley J.B., Krygier J.J., Zukor D.J., and Huk O.L. Size, shape, and composition of wear particles from metal-metal hip simulator testing: effects of alloy and number of loading cycles. J Biomed Mater Res A 67 1 (2003) 312-327
    • (2003) J Biomed Mater Res A , vol.67 , Issue.1 , pp. 312-327
    • Catelas, I.1    Bobyn, J.D.2    Medley, J.B.3    Krygier, J.J.4    Zukor, D.J.5    Huk, O.L.6
  • 20
    • 0742266793 scopus 로고    scopus 로고
    • Differences in the fretting corrosion of metal-metal and ceramic-metal modular junctions of total hip replacements
    • Hallab N.J., Messina C., Skipor A., and Jacobs J.J. Differences in the fretting corrosion of metal-metal and ceramic-metal modular junctions of total hip replacements. J Orthop Res 22 (2004) 250-259
    • (2004) J Orthop Res , vol.22 , pp. 250-259
    • Hallab, N.J.1    Messina, C.2    Skipor, A.3    Jacobs, J.J.4
  • 21
    • 33645961394 scopus 로고    scopus 로고
    • The role of fretting damage in total hip arthoplasty with modular design hip joints - evaluation of retrieval studies and experimental simulation methods
    • Schaff P. The role of fretting damage in total hip arthoplasty with modular design hip joints - evaluation of retrieval studies and experimental simulation methods. J Appl Biomater Biomech 2 (2004) 121-135
    • (2004) J Appl Biomater Biomech , vol.2 , pp. 121-135
    • Schaff, P.1
  • 22
    • 0019596946 scopus 로고
    • Fretting corrosion in saline and serum
    • Brown S.A., and Merritt K. Fretting corrosion in saline and serum. J Biomed Mater Res 15 4 (1981) 479-488
    • (1981) J Biomed Mater Res , vol.15 , Issue.4 , pp. 479-488
    • Brown, S.A.1    Merritt, K.2
  • 23
    • 0019452650 scopus 로고
    • In vivo and In vitro considerations of corrosion testing
    • Brown S.A., and Merritt K. In vivo and In vitro considerations of corrosion testing. Biomater Med Dev Artif Organs 9 1 (1981) 57-63
    • (1981) Biomater Med Dev Artif Organs , vol.9 , Issue.1 , pp. 57-63
    • Brown, S.A.1    Merritt, K.2
  • 24
    • 0028666258 scopus 로고
    • Corrosion and other electrochemical aspects of biomaterials
    • Bundy K.J. Corrosion and other electrochemical aspects of biomaterials. Crit Rev Biomed Eng 22 3-4 (1994) 139-251
    • (1994) Crit Rev Biomed Eng , vol.22 , Issue.3-4 , pp. 139-251
    • Bundy, K.J.1
  • 25
    • 0021955136 scopus 로고
    • Ph Shifts and precipitation associated with metal-ions in tissue-culture
    • Bundy K.J., Kelly R.G., Brown E.L., and Delahunty C.M. Ph Shifts and precipitation associated with metal-ions in tissue-culture. Biomaterials 6 2 (1985) 89-96
    • (1985) Biomaterials , vol.6 , Issue.2 , pp. 89-96
    • Bundy, K.J.1    Kelly, R.G.2    Brown, E.L.3    Delahunty, C.M.4
  • 26
    • 0025762324 scopus 로고
    • Stress-enhanced ion release - the effect of static loading
    • Bundy K.J., Williams C.J., and Luedemann R.E. Stress-enhanced ion release - the effect of static loading. Biomaterials 12 7 (1991) 627-639
    • (1991) Biomaterials , vol.12 , Issue.7 , pp. 627-639
    • Bundy, K.J.1    Williams, C.J.2    Luedemann, R.E.3
  • 27
    • 0037217914 scopus 로고    scopus 로고
    • Fretting corrosion behaviour of ball-and-socket joint on dental implants with different prosthodontic alloys
    • Gil F.J., Canedo R., Padros A., Baneres M.V., and Arano J.M. Fretting corrosion behaviour of ball-and-socket joint on dental implants with different prosthodontic alloys. Bio-Med Mater Eng 13 1 (2003) 27-34
    • (2003) Bio-Med Mater Eng , vol.13 , Issue.1 , pp. 27-34
    • Gil, F.J.1    Canedo, R.2    Padros, A.3    Baneres, M.V.4    Arano, J.M.5
  • 29
    • 0030088127 scopus 로고    scopus 로고
    • Design-related fretting wear in modular neck hip prosthesis
    • Viceconti M., Ruggeri O., Toni A., and Giunti A. Design-related fretting wear in modular neck hip prosthesis. J Biomed Mater Res 30 2 (1996) 181-186
    • (1996) J Biomed Mater Res , vol.30 , Issue.2 , pp. 181-186
    • Viceconti, M.1    Ruggeri, O.2    Toni, A.3    Giunti, A.4
  • 30
    • 0042171490 scopus 로고    scopus 로고
    • The composition of the surface passive film formed on CoCrMo alloy in simulated physiological solution
    • Miloslev I., and Strehblow H.H. The composition of the surface passive film formed on CoCrMo alloy in simulated physiological solution. Electrochim. Acta 48 (2003) 2767-2774
    • (2003) Electrochim. Acta , vol.48 , pp. 2767-2774
    • Miloslev, I.1    Strehblow, H.H.2
  • 31
    • 0031555492 scopus 로고    scopus 로고
    • Electrochemical response of CoCrMo to high-speed fracture of its metal oxide using an electrochemical scratch test method
    • Goldberg J.R., and Gilbert J.L. Electrochemical response of CoCrMo to high-speed fracture of its metal oxide using an electrochemical scratch test method. J Biomed Mater Res 37 (1997) 421-431
    • (1997) J Biomed Mater Res , vol.37 , pp. 421-431
    • Goldberg, J.R.1    Gilbert, J.L.2
  • 32
    • 0027897650 scopus 로고
    • In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling
    • Gilbert J.L., Buckley C.A., and Jacobs J.J. In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling. J Biomed Mater Res 27 (1993) 1533-1544
    • (1993) J Biomed Mater Res , vol.27 , pp. 1533-1544
    • Gilbert, J.L.1    Buckley, C.A.2    Jacobs, J.J.3
  • 33
    • 38949145449 scopus 로고    scopus 로고
    • Fraker AC, editor. ASM handbook. Corrosion of metallic implants and prosthetic devices. vol. 13. p. 1324-1335.
    • Fraker AC, editor. ASM handbook. Corrosion of metallic implants and prosthetic devices. vol. 13. p. 1324-1335.
  • 34
    • 58749086215 scopus 로고    scopus 로고
    • Characterization of application specific probes for SPMs
    • Tortones M., and Kirk M. Characterization of application specific probes for SPMs. SPIE 3009 (1997) 53-60
    • (1997) SPIE , vol.3009 , pp. 53-60
    • Tortones, M.1    Kirk, M.2
  • 35
    • 1242307291 scopus 로고    scopus 로고
    • Prediction of scratch resistance of cobalt chromium alloy bearing surface, articulating against ultra-high molecular weight polyethylene, due to third-body wear particles
    • Mirghany M., and Jin Z. Prediction of scratch resistance of cobalt chromium alloy bearing surface, articulating against ultra-high molecular weight polyethylene, due to third-body wear particles. Proc Inst Mech Eng Part H: J Eng Med 218 1 (2004) 41-50
    • (2004) Proc Inst Mech Eng Part H: J Eng Med , vol.218 , Issue.1 , pp. 41-50
    • Mirghany, M.1    Jin, Z.2
  • 36
    • 85040875608 scopus 로고
    • Cambridge University Press, Cambridge
    • Johnson K.L. Contact mechanics (1994), Cambridge University Press, Cambridge
    • (1994) Contact mechanics
    • Johnson, K.L.1
  • 37
    • 0030109920 scopus 로고    scopus 로고
    • Influences of stress on the measurement of mechanical properties using nanoindentation: Part I. Experimental studies in an aluminum alloy
    • Tsui T.Y., Oliver W.C., and Pharr G.M. Influences of stress on the measurement of mechanical properties using nanoindentation: Part I. Experimental studies in an aluminum alloy. J Mater Res 11 (1996) 752-759
    • (1996) J Mater Res , vol.11 , pp. 752-759
    • Tsui, T.Y.1    Oliver, W.C.2    Pharr, G.M.3
  • 38
    • 11244319566 scopus 로고    scopus 로고
    • Atomistic simulation of the influence of pre-existing stress on the interpretation of nanoindentation data
    • Schall J.D., and Brenner D.W. Atomistic simulation of the influence of pre-existing stress on the interpretation of nanoindentation data. J Mater Res 19 11 (2004) 3172-3180
    • (2004) J Mater Res , vol.19 , Issue.11 , pp. 3172-3180
    • Schall, J.D.1    Brenner, D.W.2
  • 39
    • 0038679478 scopus 로고    scopus 로고
    • Passive film on orthopaedic TiAlV alloy formed in physiological solution investigated by X-ray photoelectron spectroscopy
    • Milosev I., Metikos-Hukovic M., and Strehblow H.H. Passive film on orthopaedic TiAlV alloy formed in physiological solution investigated by X-ray photoelectron spectroscopy. Biomaterials 21 20 (2000) 2103-2113
    • (2000) Biomaterials , vol.21 , Issue.20 , pp. 2103-2113
    • Milosev, I.1    Metikos-Hukovic, M.2    Strehblow, H.H.3
  • 40
    • 0028730620 scopus 로고
    • Crack deflection at an interface between dissimilar elastic-materials - role of residual-stresses
    • He M.Y., Evans A.G., and Hutchinson J.W. Crack deflection at an interface between dissimilar elastic-materials - role of residual-stresses. Int J Solids Struct 31 24 (1994) 3443-3455
    • (1994) Int J Solids Struct , vol.31 , Issue.24 , pp. 3443-3455
    • He, M.Y.1    Evans, A.G.2    Hutchinson, J.W.3
  • 41
    • 0242275370 scopus 로고    scopus 로고
    • Effect of residual stress in surface layer on contact deformation of elastic-plastic layered media
    • Ye N., and Komvopoulos K. Effect of residual stress in surface layer on contact deformation of elastic-plastic layered media. J Tribol 125 (2003) 692-699
    • (2003) J Tribol , vol.125 , pp. 692-699
    • Ye, N.1    Komvopoulos, K.2
  • 42
    • 17944387684 scopus 로고    scopus 로고
    • Evolution of a surface-roughness spectrum caused by stress in nanometer-scale chemical etching
    • Kim K.S., Hurtado J.A., and Tan H. Evolution of a surface-roughness spectrum caused by stress in nanometer-scale chemical etching. Phys Rev Lett 83 19 (1999) 3872-3875
    • (1999) Phys Rev Lett , vol.83 , Issue.19 , pp. 3872-3875
    • Kim, K.S.1    Hurtado, J.A.2    Tan, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.