메뉴 건너뛰기




Volumn 33, Issue 1, 2008, Pages 14-21

Implementation of in vivo Dosimetry with Isorad™ Semiconductor Diodes in Radiotherapy Treatments of the Pelvis

Author keywords

Diodes; In vivo dosimetry; Pelvic treatments; Quality assurance

Indexed keywords

ARTICLE; BEAM THERAPY; CALIBRATION; CANCER RADIOTHERAPY; DOSIMETER; DOSIMETRY; HISTOGRAM; IN VIVO STUDY; INSTRUMENT VALIDATION; LIGHT EMITTING DIODE; PELVIS; PRIORITY JOURNAL; RADIATION DOSE; RADIATION DOSE DISTRIBUTION; RADIATION FIELD; SEMICONDUCTOR;

EID: 38849101782     PISSN: 09583947     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.meddos.2007.04.004     Document Type: Article
Times cited : (12)

References (22)
  • 1
    • 0027145156 scopus 로고
    • In vivo dosimetry during conformal therapy of prostatic cancer
    • Essers M., Lanson J.H., and Mijnheer B.J. In vivo dosimetry during conformal therapy of prostatic cancer. Radiother. Oncol 29 (1993) 271-279
    • (1993) Radiother. Oncol , vol.29 , pp. 271-279
    • Essers, M.1    Lanson, J.H.2    Mijnheer, B.J.3
  • 2
    • 0026587135 scopus 로고
    • Human errors in data transfer during the preparation and delivery of radiation treatment affecting the final result. Garbage in garbage out
    • Leunens G., Verstraete J., Van den Bogaert W., et al. Human errors in data transfer during the preparation and delivery of radiation treatment affecting the final result. Garbage in garbage out. Radiother. Oncol 23 (1992) 217-222
    • (1992) Radiother. Oncol , vol.23 , pp. 217-222
    • Leunens, G.1    Verstraete, J.2    Van den Bogaert, W.3
  • 3
    • 0023184257 scopus 로고
    • Quality assurance in radiation therapy: Systematic evaluation of errors during the treatment execution
    • Blanco S., Lopez-Bole M.A., and Desco M. Quality assurance in radiation therapy: Systematic evaluation of errors during the treatment execution. Radiother. Oncol 8 (1987) 253-261
    • (1987) Radiother. Oncol , vol.8 , pp. 253-261
    • Blanco, S.1    Lopez-Bole, M.A.2    Desco, M.3
  • 4
    • 0021709127 scopus 로고
    • When and how can we improve precision in radiotherapy? Radiother
    • Dutreix A. When and how can we improve precision in radiotherapy? Radiother. Oncol 2 (1984) 275-292
    • (1984) Oncol , vol.2 , pp. 275-292
    • Dutreix, A.1
  • 5
    • 0028958815 scopus 로고
    • Detection of errors in individual patients in radiotherapy by systematic in vivo dosimetry
    • Noel A., Aletti P., Bey P., et al. Detection of errors in individual patients in radiotherapy by systematic in vivo dosimetry. Radiother. Oncol 34 (1995) 144-151
    • (1995) Radiother. Oncol , vol.34 , pp. 144-151
    • Noel, A.1    Aletti, P.2    Bey, P.3
  • 6
    • 0028230872 scopus 로고
    • Comprehensive QA for radiation oncology: Report of AAPM Radiation Therapy Committee Task Group 40
    • Kutcher G.J., Coia L., Gillin M., et al. Comprehensive QA for radiation oncology: Report of AAPM Radiation Therapy Committee Task Group 40. Med. Phys 21 (1994) 581-618
    • (1994) Med. Phys , vol.21 , pp. 581-618
    • Kutcher, G.J.1    Coia, L.2    Gillin, M.3
  • 7
    • 0033556681 scopus 로고    scopus 로고
    • In vivo dosimetry during external photon beam radiotherapy
    • Essers M., and Mijnheer B.J. In vivo dosimetry during external photon beam radiotherapy. Int. J. Radiat Oncol Biol Phys 43 (1999) 245-259
    • (1999) Int. J. Radiat Oncol Biol Phys , vol.43 , pp. 245-259
    • Essers, M.1    Mijnheer, B.J.2
  • 8
    • 0030981989 scopus 로고    scopus 로고
    • Characterization of the response of commercial diode detectors used for in vivo dosimetry
    • Meiler R.J., and Podgorsak M.B. Characterization of the response of commercial diode detectors used for in vivo dosimetry. Med. Dosim 22 (1997) 31-37
    • (1997) Med. Dosim , vol.22 , pp. 31-37
    • Meiler, R.J.1    Podgorsak, M.B.2
  • 9
    • 0027212572 scopus 로고
    • Linearity with dose rate of low resistivity p-type silicon semiconductor detector
    • Grussell E., and Rikner G. Linearity with dose rate of low resistivity p-type silicon semiconductor detector. Phys. Med. Biol 38 (1993) 785-792
    • (1993) Phys. Med. Biol , vol.38 , pp. 785-792
    • Grussell, E.1    Rikner, G.2
  • 10
    • 0025685514 scopus 로고
    • Correlation between temperature and dose rate dependence of semiconductor response; influence of the accumulated dose
    • Van Dam J., Leunens G., and Dutreix A. Correlation between temperature and dose rate dependence of semiconductor response; influence of the accumulated dose. Radiother. Oncol 19 (1990) 345-351
    • (1990) Radiother. Oncol , vol.19 , pp. 345-351
    • Van Dam, J.1    Leunens, G.2    Dutreix, A.3
  • 12
    • 0032939033 scopus 로고    scopus 로고
    • Measurements of head-scatter factors with cylindrical build-up caps and columnar miniphantoms
    • Jursinic P.A., and Thomadsen B.R. Measurements of head-scatter factors with cylindrical build-up caps and columnar miniphantoms. Med. Phys 26 (1999) 512-517
    • (1999) Med. Phys , vol.26 , pp. 512-517
    • Jursinic, P.A.1    Thomadsen, B.R.2
  • 13
    • 0030940762 scopus 로고    scopus 로고
    • The effect of dose rate dependence of p-type silicon detectors on linac relative dosimetry
    • Wilkins D., Li X.A., Cygler J., et al. The effect of dose rate dependence of p-type silicon detectors on linac relative dosimetry. Med. Phys 24 (1997) 879-891
    • (1997) Med. Phys , vol.24 , pp. 879-891
    • Wilkins, D.1    Li, X.A.2    Cygler, J.3
  • 14
    • 0034858227 scopus 로고    scopus 로고
    • Implementation of an in vivo diode dosimetry program and changes in diode characteristics over a 4-year clinical history
    • Jursinic P.A. Implementation of an in vivo diode dosimetry program and changes in diode characteristics over a 4-year clinical history. Med. Phys 28 (2001) 1718-1726
    • (2001) Med. Phys , vol.28 , pp. 1718-1726
    • Jursinic, P.A.1
  • 15
    • 0022538071 scopus 로고
    • Evaluation of temperature effects in p-type silicon diodes
    • Grusell E., and Rikner G. Evaluation of temperature effects in p-type silicon diodes. Phys. Med. Biol 31 (1986) 527-534
    • (1986) Phys. Med. Biol , vol.31 , pp. 527-534
    • Grusell, E.1    Rikner, G.2
  • 16
    • 0021979174 scopus 로고
    • 60Co beams, by means of direct measurements on the incident and on the exit surfaces
    • 60Co beams, by means of direct measurements on the incident and on the exit surfaces. Radiother. Oncol 3 (1985) 279-283
    • (1985) Radiother. Oncol , vol.3 , pp. 279-283
    • Rizzotti, A.1    Compri, C.2    Garusi, G.F.3
  • 17
    • 0025110912 scopus 로고
    • Quality assurance in radiotherapy by in vivo dosimetry. 2. Determination of the target absorbed dose
    • Leunens G., Van Dam J., Dutreix A., et al. Quality assurance in radiotherapy by in vivo dosimetry. 2. Determination of the target absorbed dose. Radiother. Oncol 19 (1990) 73-87
    • (1990) Radiother. Oncol , vol.19 , pp. 73-87
    • Leunens, G.1    Van Dam, J.2    Dutreix, A.3
  • 19
    • 0141855382 scopus 로고    scopus 로고
    • Modeling the instantaneous dose rate dependence of radiation diode detectors
    • Shi J., Simon W.E., and Zhu T.C. Modeling the instantaneous dose rate dependence of radiation diode detectors. Med. Phys 30 (2003) 2509-2519
    • (2003) Med. Phys , vol.30 , pp. 2509-2519
    • Shi, J.1    Simon, W.E.2    Zhu, T.C.3
  • 20
    • 0032861327 scopus 로고    scopus 로고
    • Dosimetric evaluation of a commercial 3-D treatment planning system using Report 55 by AAPM Task Group 23
    • Declich F., Fumasoni K., Mangili P., et al. Dosimetric evaluation of a commercial 3-D treatment planning system using Report 55 by AAPM Task Group 23. Radiother. Oncol 52 (1999) 69-77
    • (1999) Radiother. Oncol , vol.52 , pp. 69-77
    • Declich, F.1    Fumasoni, K.2    Mangili, P.3
  • 22
    • 0035571530 scopus 로고    scopus 로고
    • In vivo dosimetry in pelvis treatments: An a priori evaluation compared to clinical data
    • Ostinelli A., Gelosa S., Cacciatori M., et al. In vivo dosimetry in pelvis treatments: An a priori evaluation compared to clinical data. Phys. Medica XVII (2001) 217-225
    • (2001) Phys. Medica , vol.XVII , pp. 217-225
    • Ostinelli, A.1    Gelosa, S.2    Cacciatori, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.