메뉴 건너뛰기




Volumn 24, Issue 1, 2008, Pages 58-74

Effect of ventricle motion on the dynamic behaviour of chorded mitral valves

Author keywords

Fluid structure interactions; Immersed Boundary; Mitral valve; Papillary muscle; Prosthetic heart valve; Static and dynamic loading; Ventricle motion

Indexed keywords

BOUNDARY CONDITIONS; FLUID DYNAMICS; HEART VALVE PROSTHESES; MAGNETIC RESONANCE IMAGING;

EID: 38849095097     PISSN: 08899746     EISSN: 10958622     Source Type: Journal    
DOI: 10.1016/j.jfluidstructs.2007.06.004     Document Type: Article
Times cited : (32)

References (55)
  • 2
    • 0037368361 scopus 로고    scopus 로고
    • Model and influence of mitral valve opening during the left ventricular filling
    • Bacanni B., Domenichini F., and Pedrizzetti G. Model and influence of mitral valve opening during the left ventricular filling. Journal of Biomechanics 36 3 (2003) 355-361
    • (2003) Journal of Biomechanics , vol.36 , Issue.3 , pp. 355-361
    • Bacanni, B.1    Domenichini, F.2    Pedrizzetti, G.3
  • 3
    • 0014668472 scopus 로고
    • Fluid mechanics of the mitral valve
    • Bellhouse B.J., and Bellhouse F.H. Fluid mechanics of the mitral valve. Nature (London) 224 (1969) 615-618
    • (1969) Nature (London) , vol.224 , pp. 615-618
    • Bellhouse, B.J.1    Bellhouse, F.H.2
  • 4
    • 0029256665 scopus 로고
    • Calcification and fatigue failure in a polyurethane heart valve
    • Bernacca G.M., Mackay T.G., Wilkinson R., and Wheatley D.J. Calcification and fatigue failure in a polyurethane heart valve. Biomaterials 16 4 (1995) 279-285
    • (1995) Biomaterials , vol.16 , Issue.4 , pp. 279-285
    • Bernacca, G.M.1    Mackay, T.G.2    Wilkinson, R.3    Wheatley, D.J.4
  • 5
    • 0029658660 scopus 로고    scopus 로고
    • In vitro function and durability of a polyurethane heart valve: material considerations
    • Bernacca G.M., Mackay T.G., and Wheatley D.J. In vitro function and durability of a polyurethane heart valve: material considerations. Journal of Heart Valve Disease 5 5 (1996) 538-542
    • (1996) Journal of Heart Valve Disease , vol.5 , Issue.5 , pp. 538-542
    • Bernacca, G.M.1    Mackay, T.G.2    Wheatley, D.J.3
  • 7
    • 0035998378 scopus 로고    scopus 로고
    • Mechanical and morphological study of biostable polyurethane heart valve leaflets explanted from sheep
    • Bernacca G.M., Straub I., and Wheatley D.J. Mechanical and morphological study of biostable polyurethane heart valve leaflets explanted from sheep. Journal of Biomedical Materials Research 61 1 (2002) 138-145
    • (2002) Journal of Biomedical Materials Research , vol.61 , Issue.1 , pp. 138-145
    • Bernacca, G.M.1    Straub, I.2    Wheatley, D.J.3
  • 8
    • 5144230117 scopus 로고    scopus 로고
    • Comparison of prosthetic valve hydrodynamic function: objective testing using statistical multilevel modeling
    • Bernacca G.M., McColl J.H., and Wheatley D.J. Comparison of prosthetic valve hydrodynamic function: objective testing using statistical multilevel modeling. Journal of Heart Valve Disease 13 3 (2004) 467-477
    • (2004) Journal of Heart Valve Disease , vol.13 , Issue.3 , pp. 467-477
    • Bernacca, G.M.1    McColl, J.H.2    Wheatley, D.J.3
  • 10
    • 12344329453 scopus 로고    scopus 로고
    • Nonhomogeneous deformation in the anterior leaflet of the mitral valve
    • Chen L., McCulloch A.D., and May-Newman K. Nonhomogeneous deformation in the anterior leaflet of the mitral valve. Annals of Biomedical Engineering 32 12 (2004) 1599-1606
    • (2004) Annals of Biomedical Engineering , vol.32 , Issue.12 , pp. 1599-1606
    • Chen, L.1    McCulloch, A.D.2    May-Newman, K.3
  • 12
    • 0032459920 scopus 로고    scopus 로고
    • Effect of papillary muscle position on mitral valve function: relationship to homografts
    • Cochran R.P., and Kunzelman K.S. Effect of papillary muscle position on mitral valve function: relationship to homografts. Annals of Thoracic Surgery 66 6, Suppl. (1998) S155-S161
    • (1998) Annals of Thoracic Surgery , vol.66 , Issue.6 SUPPL
    • Cochran, R.P.1    Kunzelman, K.S.2
  • 15
    • 0002265666 scopus 로고
    • A computational model of aquatic animal locomotion
    • Fauci L.J., and Peskin C.S. A computational model of aquatic animal locomotion. Journal of Computational Physics 77 1 (1988) 85-108
    • (1988) Journal of Computational Physics , vol.77 , Issue.1 , pp. 85-108
    • Fauci, L.J.1    Peskin, C.S.2
  • 16
    • 0022668967 scopus 로고
    • Design of a function test apparatus for prosthetic heart valves: initial results in the mitral position
    • Fisher J., Jack G.R., and Wheatley D.J. Design of a function test apparatus for prosthetic heart valves: initial results in the mitral position. Clinical Physics and Physiological Measurement 7 1 (1986) 63-73
    • (1986) Clinical Physics and Physiological Measurement , vol.7 , Issue.1 , pp. 63-73
    • Fisher, J.1    Jack, G.R.2    Wheatley, D.J.3
  • 17
    • 33645498146 scopus 로고    scopus 로고
    • Biaxial stress-stretch behavior of the mitral valve anterior leaflet at physiologic strain rates
    • Grashow J.S., Yoganathan A.P., and Sacks M.S. Biaxial stress-stretch behavior of the mitral valve anterior leaflet at physiologic strain rates. Annals of Biomedical Engineering 34 2 (2006) 315-325
    • (2006) Annals of Biomedical Engineering , vol.34 , Issue.2 , pp. 315-325
    • Grashow, J.S.1    Yoganathan, A.P.2    Sacks, M.S.3
  • 25
    • 0031193669 scopus 로고    scopus 로고
    • Annular dilatation increases stress in the mitral valve and delays coaptation: a finite element computer model
    • Kunzelman K.S., Reimink M.S., and Cochran R.P. Annular dilatation increases stress in the mitral valve and delays coaptation: a finite element computer model. Cardiovascular Surgery 5 4 (1997) 427-434
    • (1997) Cardiovascular Surgery , vol.5 , Issue.4 , pp. 427-434
    • Kunzelman, K.S.1    Reimink, M.S.2    Cochran, R.P.3
  • 26
    • 0031933187 scopus 로고    scopus 로고
    • Flexible versus rigid ring annuloplasty for mitral valve annular dilatation: a finite element model
    • Kunzelman K.S., Reimink M.S., and Cochran R.P. Flexible versus rigid ring annuloplasty for mitral valve annular dilatation: a finite element model. Journal of Heart Valve Disease 7 1 (1998) 108-116
    • (1998) Journal of Heart Valve Disease , vol.7 , Issue.1 , pp. 108-116
    • Kunzelman, K.S.1    Reimink, M.S.2    Cochran, R.P.3
  • 27
    • 0032451035 scopus 로고    scopus 로고
    • Altered collagen concentration in mitral valve leaflets: biochemical and finite element analysis
    • Kunzelman K.S., Quick D.W., and Cochran R.P. Altered collagen concentration in mitral valve leaflets: biochemical and finite element analysis. Annals of Thoracic Surgery 66 6, Suppl. (1998) S198-S205
    • (1998) Annals of Thoracic Surgery , vol.66 , Issue.6 SUPPL
    • Kunzelman, K.S.1    Quick, D.W.2    Cochran, R.P.3
  • 28
    • 0038724493 scopus 로고    scopus 로고
    • A structural basis for the size-related mechanical properties of mitral valve chordae tendineae
    • Liao J., and Vesely I. A structural basis for the size-related mechanical properties of mitral valve chordae tendineae. Journal of Biomechanics 36 8 (2003) 1125-1133
    • (2003) Journal of Biomechanics , vol.36 , Issue.8 , pp. 1125-1133
    • Liao, J.1    Vesely, I.2
  • 29
    • 24344509871 scopus 로고    scopus 로고
    • Three dimensional asymmetrical modeling of the mitral valve: a finite element study with dynamic boundaries
    • Lim K.H., Yeo J.H., and Duran C.M.G. Three dimensional asymmetrical modeling of the mitral valve: a finite element study with dynamic boundaries. Journal of Heart Valve Disease 14 3 (2005) 386-392
    • (2005) Journal of Heart Valve Disease , vol.14 , Issue.3 , pp. 386-392
    • Lim, K.H.1    Yeo, J.H.2    Duran, C.M.G.3
  • 30
    • 33847370785 scopus 로고    scopus 로고
    • Effect of fiber orientation on the stress distribution within a leaflet of a polymer composite heart valve in the closed position
    • Liu Y.R., Kasyanov V., and Schoephoerster R.T. Effect of fiber orientation on the stress distribution within a leaflet of a polymer composite heart valve in the closed position. Journal of Biomechanics 40 (2007) 1099-1106
    • (2007) Journal of Biomechanics , vol.40 , pp. 1099-1106
    • Liu, Y.R.1    Kasyanov, V.2    Schoephoerster, R.T.3
  • 31
    • 38849208657 scopus 로고    scopus 로고
    • Mackay, T.G., 1992. Towards a tri-leaflet polyurethane heart valve prosthesis. Ph.D. Thesis, University of Strathclyde, Thesis no. T7473.
    • Mackay, T.G., 1992. Towards a tri-leaflet polyurethane heart valve prosthesis. Ph.D. Thesis, University of Strathclyde, Thesis no. T7473.
  • 34
    • 33745915754 scopus 로고
    • Study of the closing mechanism of natural heart valves
    • Ming L., and Zhen H.K. Study of the closing mechanism of natural heart valves. Applied Mathematics and Mechanics 7 (1986) 955-964
    • (1986) Applied Mathematics and Mechanics , vol.7 , pp. 955-964
    • Ming, L.1    Zhen, H.K.2
  • 35
    • 0031371610 scopus 로고    scopus 로고
    • Shared-memory parallel vector implementation of the immersed boundary method for the computation of blood flow in the beating mammalian heart
    • McQueen D.M., and Peskin C.S. Shared-memory parallel vector implementation of the immersed boundary method for the computation of blood flow in the beating mammalian heart. Journal of Supercomputing 11 3 (1997) 213-236
    • (1997) Journal of Supercomputing , vol.11 , Issue.3 , pp. 213-236
    • McQueen, D.M.1    Peskin, C.S.2
  • 36
    • 49649145203 scopus 로고
    • Flow patterns around heart valves: a numerical method
    • Peskin C.S. Flow patterns around heart valves: a numerical method. Journal of Computational Physics 10 (1972) 252-271
    • (1972) Journal of Computational Physics , vol.10 , pp. 252-271
    • Peskin, C.S.1
  • 37
    • 0017424014 scopus 로고
    • Numerical analysis of blood flow in the heart
    • Peskin C.S. Numerical analysis of blood flow in the heart. Journal of Computational Physics 25 (1977) 220-252
    • (1977) Journal of Computational Physics , vol.25 , pp. 220-252
    • Peskin, C.S.1
  • 38
    • 33751544551 scopus 로고    scopus 로고
    • The immersed boundary method
    • Peskin C.S. The immersed boundary method. Acta Numerica 11 (2002) 479-517
    • (2002) Acta Numerica , vol.11 , pp. 479-517
    • Peskin, C.S.1
  • 39
    • 45149143078 scopus 로고
    • A three dimensional computational method for blood flow in the heart I. Immersed elastic fibres in a viscous incompressible fluid
    • Peskin C.S., and McQueen D.M. A three dimensional computational method for blood flow in the heart I. Immersed elastic fibres in a viscous incompressible fluid. Journal of Computational Physics 81 2 (1989) 372-405
    • (1989) Journal of Computational Physics , vol.81 , Issue.2 , pp. 372-405
    • Peskin, C.S.1    McQueen, D.M.2
  • 40
    • 0029437912 scopus 로고
    • A general method for the computer simulation of biological systems interacting with fluids
    • Peskin C.S., and McQueen D.M. A general method for the computer simulation of biological systems interacting with fluids. Symposia of the Society for Experimental Biology 49 (1995) 265-276
    • (1995) Symposia of the Society for Experimental Biology , vol.49 , pp. 265-276
    • Peskin, C.S.1    McQueen, D.M.2
  • 41
    • 0002680335 scopus 로고    scopus 로고
    • Fluid dynamics of the heart and its valves
    • Othmer H.G., Adler F.R., Lewis M.A., and Dallon J.C. (Eds), Prentice-Hall, Englewood Cliffs, NJ
    • Peskin C.S., and McQueen D.M. Fluid dynamics of the heart and its valves. In: Othmer H.G., Adler F.R., Lewis M.A., and Dallon J.C. (Eds). Case Studies in Mathematical Modeling: Ecology, Physiology, and Cell Biology (1996), Prentice-Hall, Englewood Cliffs, NJ 309-337
    • (1996) Case Studies in Mathematical Modeling: Ecology, Physiology, and Cell Biology , pp. 309-337
    • Peskin, C.S.1    McQueen, D.M.2
  • 42
    • 33746862145 scopus 로고    scopus 로고
    • The effect of vortex formation on left ventricular filling and mitral valve efficiency
    • Pierrakos O., and Vlachos P.P. The effect of vortex formation on left ventricular filling and mitral valve efficiency. Journal of Biomechanical Engineering 128 4 (2006) 527-539
    • (2006) Journal of Biomechanical Engineering , vol.128 , Issue.4 , pp. 527-539
    • Pierrakos, O.1    Vlachos, P.P.2
  • 43
    • 0035663304 scopus 로고    scopus 로고
    • A computational study of the hemodynamics after "Edge-to-Edge" mitral valve repair
    • Redaelli A., Guadagni G., and Fumero R. A computational study of the hemodynamics after "Edge-to-Edge" mitral valve repair. Journal of Biomechanical Engineering 123 6 (2001) 565-570
    • (2001) Journal of Biomechanical Engineering , vol.123 , Issue.6 , pp. 565-570
    • Redaelli, A.1    Guadagni, G.2    Fumero, R.3
  • 44
    • 0029783773 scopus 로고    scopus 로고
    • The effect of chordal replacement suture length on function and stresses in repaired mitral valves: a finite element study
    • Reimink M.S., Kunzelman K.S., and Cochran R.P. The effect of chordal replacement suture length on function and stresses in repaired mitral valves: a finite element study. Journal of Heart Valve Disease 5 4 (1996) 365-375
    • (1996) Journal of Heart Valve Disease , vol.5 , Issue.4 , pp. 365-375
    • Reimink, M.S.1    Kunzelman, K.S.2    Cochran, R.P.3
  • 46
    • 33645087135 scopus 로고    scopus 로고
    • The material properties of the native porcine mitral valve chordae tendineae: an in vitro investigation
    • Ritchie J., Jiminez J., He Z., Sacks M.S., and Yoganathan A.P. The material properties of the native porcine mitral valve chordae tendineae: an in vitro investigation. Journal of Biomechanics 39 6 (2006) 1129-1135
    • (2006) Journal of Biomechanics , vol.39 , Issue.6 , pp. 1129-1135
    • Ritchie, J.1    Jiminez, J.2    He, Z.3    Sacks, M.S.4    Yoganathan, A.P.5
  • 49
    • 0028284527 scopus 로고
    • Mitral valve anatomy and morphology: relevance to mitral valve replacement and reconstruction
    • van Rijk-Zwikker G.L., Delemarre B.J., and Huysmans H.A. Mitral valve anatomy and morphology: relevance to mitral valve replacement and reconstruction. Journal of Cardiac Surgery 9 2, Suppl. (1994) 255-261
    • (1994) Journal of Cardiac Surgery , vol.9 , Issue.2 SUPPL , pp. 255-261
    • van Rijk-Zwikker, G.L.1    Delemarre, B.J.2    Huysmans, H.A.3
  • 50
    • 0141737644 scopus 로고    scopus 로고
    • The evolution of bioprosthetic heart valve design and its impact on durability
    • Vesely I. The evolution of bioprosthetic heart valve design and its impact on durability. Cardiovascular Pathology 12 (2003) 277-286
    • (2003) Cardiovascular Pathology , vol.12 , pp. 277-286
    • Vesely, I.1
  • 52
    • 38849142755 scopus 로고    scopus 로고
    • Wheatley, D.J., 2002. Mitral valve prosthesis. Patent number WO03037227.
    • Wheatley, D.J., 2002. Mitral valve prosthesis. Patent number WO03037227.
  • 54
    • 38849184330 scopus 로고    scopus 로고
    • Yoganathan, A.P., 2000. Cardiac Valve Prosthesis. In: Bronzino, J.D. (Ed.), The Biomedical Engineering Handbook, Vol. 2, CRC Press, Boca Raton, FL.
    • Yoganathan, A.P., 2000. Cardiac Valve Prosthesis. In: Bronzino, J.D. (Ed.), The Biomedical Engineering Handbook, Vol. 2, CRC Press, Boca Raton, FL.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.