메뉴 건너뛰기




Volumn 39, Issue 6, 2006, Pages 1129-1135

The material properties of the native porcine mitral valve chordae tendineae: An in vitro investigation

Author keywords

Chordae tendineae; Dynamic imaging; Heart valves; Mitral valve; Valve function

Indexed keywords

CAMERAS; CARDIOLOGY; IMAGING TECHNIQUES; PATHOLOGY; PHOTOGRAMMETRY; TISSUE;

EID: 33645087135     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2005.01.024     Document Type: Article
Times cited : (64)

References (17)
  • 2
    • 0032841124 scopus 로고    scopus 로고
    • Ultrastructure abnormalities in proteoglycans, collagen fibrils, and elastic fibers in normal and myxomatous mitral valve chordae tendineae
    • S. Akhtar, K.M. Meek, and V. James Ultrastructure abnormalities in proteoglycans, collagen fibrils, and elastic fibers in normal and myxomatous mitral valve chordae tendineae Cardiovascular Pathology 8 1999 191 201
    • (1999) Cardiovascular Pathology , vol.8 , pp. 191-201
    • Akhtar, S.1    Meek, K.M.2    James, V.3
  • 3
    • 0026315593 scopus 로고
    • Comparison of viscoelastic properties of suture versus porcine mitral valve chordae tendineae
    • R.P. Cochran, and K.S. Kunzelman Comparison of viscoelastic properties of suture versus porcine mitral valve chordae tendineae Journal of Cardiac Surgery 6 4 1991 508 513
    • (1991) Journal of Cardiac Surgery , vol.6 , Issue.4 , pp. 508-513
    • Cochran, R.P.1    Kunzelman, K.S.2
  • 6
    • 0035544009 scopus 로고    scopus 로고
    • Dynamic in vitro 3D reconstruction of heart valve leaflets using structured light projection
    • A. Iyengar, H. Sugimoto, D.B. Smith, and M. Sacks Dynamic in vitro 3D reconstruction of heart valve leaflets using structured light projection Annals of Biomedical Engineering 29 2001 963 973
    • (2001) Annals of Biomedical Engineering , vol.29 , pp. 963-973
    • Iyengar, A.1    Sugimoto, H.2    Smith, D.B.3    Sacks, M.4
  • 9
    • 0346335582 scopus 로고    scopus 로고
    • Effects of a saddle shaped annulus on mitral valve function and chordal force distribution: An in vitro study
    • J.H. Jimenez, S. He, D.D. Soerensen, Z. He, and A.P. Yoganathan Effects of a saddle shaped annulus on mitral valve function and chordal force distribution: an in vitro study Annals of Biomedical Engineering 31 10 2003 1171 1181
    • (2003) Annals of Biomedical Engineering , vol.31 , Issue.10 , pp. 1171-1181
    • Jimenez, J.H.1    He, S.2    Soerensen, D.D.3    He, Z.4    Yoganathan, A.P.5
  • 10
    • 33645050332 scopus 로고    scopus 로고
    • A structural basis for the size-related mechanical properties of mitral valve chordae tendineae
    • J. Liao, and I. Vesely A structural basis for the size-related mechanical properties of mitral valve chordae tendineae Journal of Biomechanics 192 2003 573 581
    • (2003) Journal of Biomechanics , vol.192 , pp. 573-581
    • Liao, J.1    Vesely, I.2
  • 11
    • 0016784195 scopus 로고
    • Mechanical properties of human mitral valve chordae tendineae: Variation with size and strain rate
    • K.O. Lim, and D.R. Boughner Mechanical properties of human mitral valve chordae tendineae: variation with size and strain rate Canadian Journal of Physiology and Pharmacology 53 1975 330 339
    • (1975) Canadian Journal of Physiology and Pharmacology , vol.53 , pp. 330-339
    • Lim, K.O.1    Boughner, D.R.2
  • 12
    • 0017180684 scopus 로고
    • Morphology and relationship to extensibility curves of human mitral valve chordae tendineae
    • K.O. Lim, and D.R. Boughner Morphology and relationship to extensibility curves of human mitral valve chordae tendineae Circulation Research 39 4 1976 580 585
    • (1976) Circulation Research , vol.39 , Issue.4 , pp. 580-585
    • Lim, K.O.1    Boughner, D.R.2
  • 13
    • 0016667393 scopus 로고
    • A computer program for direct linear transformation solution of the collinearity condition and some applications of it
    • American Society of Photogrammetry, Falls Church
    • Marzan, G.T., 1975. A computer program for direct linear transformation solution of the collinearity condition and some applications of it. In Proceedings of the Symposium on Close-range Photogrammetric Systems. American Society of Photogrammetry, Falls Church 420-476.
    • (1975) Proceedings of the Symposium on Close-range Photogrammetric Systems , pp. 420-476
    • Marzan, G.T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.