메뉴 건너뛰기




Volumn 128, Issue 4, 2006, Pages 527-539

The effect of vortex formation on left ventricular filling and mitral valve efficiency

Author keywords

DPIV; Left ventricular flow; Mechanical heart valves; Vortex formation

Indexed keywords

BIOMEDICAL ENGINEERING; ENERGY UTILIZATION; HEMODYNAMICS; HYDRODYNAMICS; PATIENT TREATMENT; VORTEX FLOW;

EID: 33746862145     PISSN: 01480731     EISSN: None     Source Type: Journal    
DOI: 10.1115/1.2205863     Document Type: Article
Times cited : (73)

References (57)
  • 2
    • 85041153399 scopus 로고
    • Kluwer Academic Publishers, Netherlands
    • Green Sheldon, I., 1995, Fluid Vortices, Kluwer Academic Publishers, Netherlands.
    • (1995) Fluid Vortices
    • Green Sheldon, I.1
  • 3
    • 0032048933 scopus 로고    scopus 로고
    • A universal time scale for vortex ring formation
    • Gharib, M., Rambod, E., and Shariff, K., 1998, "A Universal Time Scale for Vortex Ring Formation," J. Fluid Mech., 360, pp. 121-140.
    • (1998) J. Fluid Mech. , vol.360 , pp. 121-140
    • Gharib, M.1    Rambod, E.2    Shariff, K.3
  • 4
    • 0032301906 scopus 로고    scopus 로고
    • Circulation and formation number of laminar vortex rings
    • Rosenfeld, M., Rambod, E., and Gharib, M., 1998, "Circulation and Formation Number of Laminar Vortex Rings," J. Fluid Mech., 376, pp. 297-318.
    • (1998) J. Fluid Mech. , vol.376 , pp. 297-318
    • Rosenfeld, M.1    Rambod, E.2    Gharib, M.3
  • 6
    • 0000391212 scopus 로고
    • On the formation of vortex rings rolling-up and production of circulation
    • Didden, N., 1979, "On the Formation of Vortex Rings Rolling-up and Production of Circulation," Z. Angew. Math. Phys., 30(1), pp. 101-116.
    • (1979) Z. Angew. Math. Phys. , vol.30 , Issue.1 , pp. 101-116
    • Didden, N.1
  • 7
    • 0000100147 scopus 로고
    • Vortex ring formation at tube and orifice opening
    • Pullin, D. I., 1979, "Vortex Ring Formation at Tube and Orifice Opening," Phys. Fluids, 22, pp. 401-403.
    • (1979) Phys. Fluids , vol.22 , pp. 401-403
    • Pullin, D.I.1
  • 8
    • 0025382910 scopus 로고
    • An experimental study of a turbulent vortex ring
    • Glezer, A., and Coles, D., 1990, "An Experimental Study of a Turbulent Vortex Ring," J. Fluid Mech., 221, pp. 243-283.
    • (1990) J. Fluid Mech. , vol.221 , pp. 243-283
    • Glezer, A.1    Coles, D.2
  • 9
    • 85040958017 scopus 로고
    • Cambridge University Press, Cambridge, England
    • Saffman, P. G., 1992, Vortex Dynamics, Cambridge University Press, Cambridge, England.
    • (1992) Vortex Dynamics
    • Saffman, P.G.1
  • 10
    • 0020970223 scopus 로고
    • Laser anemometry measurements of pulsatile flow past aortic valve prostheses
    • Chandran, K. B., Cabell, G. N., Khalighi, B., and Chen, C. J., 1983, "Laser Anemometry Measurements of Pulsatile Flow Past Aortic Valve Prostheses," J. Biomech., 16(10), pp. 865-873.
    • (1983) J. Biomech. , vol.16 , Issue.10 , pp. 865-873
    • Chandran, K.B.1    Cabell, G.N.2    Khalighi, B.3    Chen, C.J.4
  • 11
    • 0022207545 scopus 로고
    • Experimental study of physiological pulsatile flow past valve prostheses in a model of human aorta: I. Caged ball valves
    • Chandran, K. B., Khaloghi, B., and Chen, C. J., 1985, "Experimental Study of Physiological Pulsatile Flow Past Valve Prostheses in a Model of Human Aorta: I. Caged Ball Valves," J. Biomech., 18(10), pp. 763-772.
    • (1985) J. Biomech. , vol.18 , Issue.10 , pp. 763-772
    • Chandran, K.B.1    Khaloghi, B.2    Chen, C.J.3
  • 12
    • 0022460289 scopus 로고
    • Comparative in vitro evaluation of porcine and pericardial bioprostheses
    • Reul, H., Giersiepen, M., Schindehutte, H., Effert, S., and Rau, G., 1986, "Comparative in vitro Evaluation of Porcine and Pericardial Bioprostheses." Z. Kardiol., 75(Suppl. 2), pp. 223-31.
    • (1986) Z. Kardiol. , vol.75 , Issue.SUPPL. 2 , pp. 223-231
    • Reul, H.1    Giersiepen, M.2    Schindehutte, H.3    Effert, S.4    Rau, G.5
  • 13
    • 0020508224 scopus 로고
    • Pressure drop and velocity fields at four mechanical heart valve prostheses: Bjork-Shiley standard, Bjork-Shiley concave-convex, Hall-Kaster and St-Jude Medical
    • Bruss, K. H., Reul, H., Van Gilse, J., and Knott, E., 1983, "Pressure Drop and Velocity Fields at Four Mechanical Heart Valve Prostheses: Bjork-Shiley Standard, Bjork-Shiley Concave-Convex, Hall-Kaster and St-Jude Medical," Life Support Syst., 1, pp. 3-22.
    • (1983) Life Support Syst. , vol.1 , pp. 3-22
    • Bruss, K.H.1    Reul, H.2    Van Gilse, J.3    Knott, E.4
  • 14
    • 0023005916 scopus 로고
    • Pressure drop and velocity fields at mechanical heart valves
    • Giersiepen, M., Reul, H., Knoch, M., and Rau, G., 1986, "Pressure Drop and Velocity Fields at Mechanical Heart Valves," Life Support Syst., 4(Suppl. 2), pp. 166-168.
    • (1986) Life Support Syst. , vol.4 , Issue.SUPPL. 2 , pp. 166-168
    • Giersiepen, M.1    Reul, H.2    Knoch, M.3    Rau, G.4
  • 15
    • 0022646878 scopus 로고
    • Turbulent shear stress measurements in the vicinity of aortic heart valve prostheses
    • Yoganathan, A. P., Woo, Y., and Sung, H., 1986, "Turbulent Shear Stress Measurements in the Vicinity of Aortic Heart Valve Prostheses," J. Biomech., 19(6), pp. 433-442.
    • (1986) J. Biomech. , vol.19 , Issue.6 , pp. 433-442
    • Yoganathan, A.P.1    Woo, Y.2    Sung, H.3
  • 16
    • 0023914290 scopus 로고
    • In vitro stress measurements in the vicinity of six mechanical aortic valves using hot-film anemometry in steady flow
    • Hasenkam, J. M., Westphal, D., Wygaard, H., Reul, H., Giersiepen, M., and Stodkilde-Jorgensen, H., 1988, "In Vitro Stress Measurements in the Vicinity of Six Mechanical Aortic Valves Using Hot-Film Anemometry in Steady Flow," J. Biomech., 21, pp. 235-47.
    • (1988) J. Biomech. , vol.21 , pp. 235-247
    • Hasenkam, J.M.1    Westphal, D.2    Wygaard, H.3    Reul, H.4    Giersiepen, M.5    Stodkilde-Jorgensen, H.6
  • 17
    • 0024420253 scopus 로고
    • In vitro flow dynamics of four prosthetic aortic valves: A comparative analysis
    • Hanle, D. D., Harrison, E. C., Yoganathan, A. P., Alens, D. T., and Corocran, W. H., 1989, "In Vitro Flow Dynamics of Four Prosthetic Aortic Valves: A Comparative Analysis," J. Biomech., 22, pp. 597-607.
    • (1989) J. Biomech. , vol.22 , pp. 597-607
    • Hanle, D.D.1    Harrison, E.C.2    Yoganathan, A.P.3    Alens, D.T.4    Corocran, W.H.5
  • 18
    • 0024504904 scopus 로고
    • Velocity and shear stress distribution downstream of mechanical heart valves in pulsatile flow
    • Giersiepen, M., Krause, U., Knott, E., Reul, H., and Rau, G., 1989, "Velocity and Shear Stress Distribution Downstream of Mechanical Heart Valves in Pulsatile Flow," Int. J. Artif. Organs, 12(4), pp. 261-269.
    • (1989) Int. J. Artif. Organs , vol.12 , Issue.4 , pp. 261-269
    • Giersiepen, M.1    Krause, U.2    Knott, E.3    Reul, H.4    Rau, G.5
  • 20
    • 0027991718 scopus 로고
    • Particle image velocimetry in the investigation of flow past artificial heart valves
    • Lim, W. L., Chew, Y. T., Chew, T. C., and Low, H. T., 1994, "Particle Image Velocimetry in the Investigation of Flow Past Artificial Heart Valves," Ann. Biomed. Eng., 22, pp. 307-318.
    • (1994) Ann. Biomed. Eng. , vol.22 , pp. 307-318
    • Lim, W.L.1    Chew, Y.T.2    Chew, T.C.3    Low, H.T.4
  • 21
    • 0022592273 scopus 로고
    • In vitro pulsatile flow velocity and shear stress measurements in the vicinity of mechanical mitral heart valve prostheses
    • Woo, Y., and Yoganathan, A. P., 1986, "In Vitro Pulsatile Flow Velocity and Shear Stress Measurements in the Vicinity of Mechanical Mitral Heart Valve Prostheses," J. Biomech., 19(6), pp. 39-51.
    • (1986) J. Biomech. , vol.19 , Issue.6 , pp. 39-51
    • Woo, Y.1    Yoganathan, A.P.2
  • 22
    • 0024555660 scopus 로고
    • Effect of prosthetic mitral valve geometry and orientation on flow dynamics in a model of human left ventricle
    • Chandran, K. B., Schoephoerster, R., and Dellesperger, K. C., 1989, "Effect of Prosthetic Mitral Valve Geometry and Orientation on Flow Dynamics in a Model of Human Left Ventricle," J. Biomech., 22(1), pp. 51-65.
    • (1989) J. Biomech. , vol.22 , Issue.1 , pp. 51-65
    • Chandran, K.B.1    Schoephoerster, R.2    Dellesperger, K.C.3
  • 23
    • 0027445219 scopus 로고
    • Effects of local geometry and fluid dynamics on regional platelet deposition on artificial surfaces
    • Schoephoerster, R. T., Oynes, F., Numez, H., Kapadvanjwala, M., and Dewanjee, M. K., 1993, "Effects of Local Geometry and Fluid Dynamics on Regional Platelet Deposition on Artificial Surfaces," Arterioscler. Thromb., 12, pp. 1806-1813.
    • (1993) Arterioscler. Thromb. , vol.12 , pp. 1806-1813
    • Schoephoerster, R.T.1    Oynes, F.2    Numez, H.3    Kapadvanjwala, M.4    Dewanjee, M.K.5
  • 24
    • 0025879372 scopus 로고
    • Velocity and turbulence measurements past mitral valve prostheses in a model left ventricle
    • Schoephoerster, R. T., and Chandran, K. B., 1991, "Velocity and Turbulence Measurements Past Mitral Valve Prostheses in a Model Left Ventricle," J. Biomech., 24(7), pp. 549-562.
    • (1991) J. Biomech. , vol.24 , Issue.7 , pp. 549-562
    • Schoephoerster, R.T.1    Chandran, K.B.2
  • 25
    • 0034177656 scopus 로고    scopus 로고
    • Vortex shedding as a mechanism for free emboli formation in mechanical heart valves
    • April
    • Bluestein, D., Rambod, E., and Gharib, M., April 2000, "Vortex Shedding as a Mechanism for Free Emboli Formation in Mechanical Heart Valves," J. Biomech. Eng., 122, pp. 125-134.
    • (2000) J. Biomech. Eng. , vol.122 , pp. 125-134
    • Bluestein, D.1    Rambod, E.2    Gharib, M.3
  • 26
    • 0034528789 scopus 로고    scopus 로고
    • High-intensity transient signals as a parameter for optimum orientation of mechanical aortic valves
    • Kleine, P., Perthel, M., Hasenkam, J. M., Nygaard, H., Hansen, S., and Laas, J. 1999, "High-Intensity Transient Signals as a parameter for Optimum Orientation of Mechanical Aortic Valves," Thorac. Cardiovasc. Surg., 48, pp. 360-363.
    • (1999) Thorac. Cardiovasc. Surg. , vol.48 , pp. 360-363
    • Kleine, P.1    Perthel, M.2    Hasenkam, J.M.3    Nygaard, H.4    Hansen, S.5    Laas, J.6
  • 27
    • 0032727007 scopus 로고    scopus 로고
    • Orientation of tilting disc and bileaflet aortic valve substitutes for optimal hemodynamics
    • Laas, J., Kleine, P., Hasenkam, M., and Nygaard, H., 1999, "Orientation of Tilting Disc and Bileaflet Aortic Valve Substitutes for Optimal Hemodynamics," Ann. Thorac. Surg., 68, pp. 10961-10969.
    • (1999) Ann. Thorac. Surg. , vol.68 , pp. 10961-10969
    • Laas, J.1    Kleine, P.2    Hasenkam, M.3    Nygaard, H.4
  • 28
    • 0029882113 scopus 로고    scopus 로고
    • In vitro assessment of prosthetic valve function in mitral valve replacement with chordal preservation techniques
    • Fontaine, A., He, S., Stadter, R., Ellis, J. T., Levine, R. A., and Yoganathan, A. P., 1996, "In Vitro Assessment of Prosthetic Valve Function in Mitral Valve Replacement with Chordal Preservation Techniques," J. Heart Valve Dis., 5(2), pp. 186-198.
    • (1996) J. Heart Valve Dis. , vol.5 , Issue.2 , pp. 186-198
    • Fontaine, A.1    He, S.2    Stadter, R.3    Ellis, J.T.4    Levine, R.A.5    Yoganathan, A.P.6
  • 30
    • 0030892412 scopus 로고    scopus 로고
    • Nonsymmetric leaflet motion of St. Jude Medical mitral valves simulated with a computer-controlled hydraulic mock circulator
    • Ohta, Y., Okamoto, K., Sonderegger, M., Dohi, T., Matsumoto, H., and Horiuchi, T., 1997, "Nonsymmetric Leaflet Motion of St. Jude Medical Mitral Valves Simulated with a Computer-Controlled Hydraulic Mock Circulator," Artif. Organs, 21(4), pp. 335-339.
    • (1997) Artif. Organs , vol.21 , Issue.4 , pp. 335-339
    • Ohta, Y.1    Okamoto, K.2    Sonderegger, M.3    Dohi, T.4    Matsumoto, H.5    Horiuchi, T.6
  • 31
    • 21144452438 scopus 로고    scopus 로고
    • In vitro dynamic strain behavior of the mitral valve posterior leaflet
    • Zhaoming, He, Ritchie, Jennifer, Grashow, Jonathan, S., Sacks, Michael, S., Yoganathan, and Ajit, P., 2005, "In Vitro Dynamic Strain Behavior of the Mitral Valve Posterior Leaflet," J. Biomech. Eng., 127, pp. 504-511.
    • (2005) J. Biomech. Eng. , vol.127 , pp. 504-511
    • Zhaoming, H.1    Ritchie, J.2    Grashow, J.S.3    Sacks, M.4    Yoganathan, S.5    Ajit, P.6
  • 32
    • 0033966638 scopus 로고    scopus 로고
    • A Comparison of the hinge and near-hinge flow fields of the St. Jude Medical hemodynamic plus and regent bileaflet mechanical heart valves
    • Ellis, Jeffrey, T., and Ajiit, Yoganathan, 2000, "A Comparison of the Hinge and Near-hinge Flow Fields of the St. Jude Medical Hemodynamic Plus and Regent Bileaflet Mechanical Heart Valves," J. Thorac. Cardiovasc. Surg., 119(1), pp. 83-93.
    • (2000) J. Thorac. Cardiovasc. Surg. , vol.119 , Issue.1 , pp. 83-93
    • Ellis, J.T.1    Ajiit, Y.2
  • 33
    • 0031281261 scopus 로고    scopus 로고
    • Three-component laser doppler velocimetry measurements in the regurgitant flow region of a Bjork-Shiley monostrut mitral valve
    • Meyer, Richard, Deutsch, Steven, Maymir, Juan-Carlos, Geselowitz, David, and Tarbell, John, 1997, "Three-Component Laser Doppler Velocimetry Measurements in the Regurgitant Flow Region of a Bjork-Shiley Monostrut Mitral Valve," Ann. Biomed. Eng., 25, pp. 1081-1091.
    • (1997) Ann. Biomed. Eng. , vol.25 , pp. 1081-1091
    • Meyer, R.1    Deutsch, S.2    Maymir, J.-C.3    Geselowitz, D.4    Tarbell, J.5
  • 35
    • 0018785433 scopus 로고
    • A fluid-mechanical study of the closure of heart valves
    • Lee, C. S. F., and Talbot, L., 1979, "A Fluid-mechanical Study of the Closure of Heart Valves," J. Fluid Mech., 91(1), pp. 41-63.
    • (1979) J. Fluid Mech. , vol.91 , Issue.1 , pp. 41-63
    • Lee, C.S.F.1    Talbot, L.2
  • 36
    • 0019425554 scopus 로고
    • Fluid mechanics of the natural mitral valve
    • Reul, H., Talukder, N., and Muller, E. W., 1981, "Fluid Mechanics of the Natural Mitral Valve," J. Biomech., 14(5), pp. 361-372.
    • (1981) J. Biomech. , vol.14 , Issue.5 , pp. 361-372
    • Reul, H.1    Talukder, N.2    Muller, E.W.3
  • 38
    • 0030148269 scopus 로고    scopus 로고
    • Pulsatile flow past bileaflet aortic valve prostheses
    • Liu, J. S., Lu, P. C., and Chu, S. H., 1996, "Pulsatile Flow Past Bileaflet Aortic Valve Prostheses," J. Chin. Inst. Eng., 19, pp. 333-344.
    • (1996) J. Chin. Inst. Eng. , vol.19 , pp. 333-344
    • Liu, J.S.1    Lu, P.C.2    Chu, S.H.3
  • 39
    • 0034281870 scopus 로고    scopus 로고
    • A new dual activation simulator of the left heart which reproduces physiological and pathological conditions
    • Mouret, F., Garitey, V., Gandelheid, T., Fuseri, R., and Rieu, R., 2000, "A New Dual Activation Simulator of the Left Heart Which Reproduces Physiological and Pathological Conditions," Med. Biol. Eng. Comput., 38, pp. 558-561.
    • (2000) Med. Biol. Eng. Comput. , vol.38 , pp. 558-561
    • Mouret, F.1    Garitey, V.2    Gandelheid, T.3    Fuseri, R.4    Rieu, R.5
  • 40
    • 0033621716 scopus 로고    scopus 로고
    • Experimental investigation of the steady flow downstream of the St. Jude Bileaflet heart valve: A comparison between laser doppler velocimetry and particle image velocimetry techniques
    • Browne, P., Ramuzat, A., Saxena, R., and Yoganathan, A. P., 2000, "Experimental Investigation of the Steady Flow Downstream of the St. Jude Bileaflet Heart Valve: A Comparison Between Laser Doppler Velocimetry and Particle Image Velocimetry Techniques," Ann. Biomed. Eng., 28(1), pp. 39-47.
    • (2000) Ann. Biomed. Eng. , vol.28 , Issue.1 , pp. 39-47
    • Browne, P.1    Ramuzat, A.2    Saxena, R.3    Yoganathan, A.P.4
  • 41
    • 14344256283 scopus 로고    scopus 로고
    • Time resolved DPIV analysis of vortex dynamics in a left ventricular model through bileaflet mechanical and porcine heart valve prostheses
    • Pierrakos, O., Vlachos, P., and Telionis, D., 2004, "Time Resolved DPIV Analysis of Vortex Dynamics in a Left Ventricular Model Through Bileaflet Mechanical and Porcine Heart Valve Prostheses," J. Biomech. Eng., 126, pp. 714-726.
    • (2004) J. Biomech. Eng. , vol.126 , pp. 714-726
    • Pierrakos, O.1    Vlachos, P.2    Telionis, D.3
  • 42
    • 0025792678 scopus 로고
    • Digital particle image velocimetry
    • Willen, C. E., and Gharib, M., 1991, "Digital Particle Image Velocimetry," Exp. Fluids, 10, pp. 181-193.
    • (1991) Exp. Fluids , vol.10 , pp. 181-193
    • Willen, C.E.1    Gharib, M.2
  • 44
    • 0031336437 scopus 로고    scopus 로고
    • On errors of digital particle image velocimetry
    • Huang, H., Dabiri, D., and Gharib, M., 1997 "On Errors of Digital Particle Image Velocimetry," Meas. Sci. Technol., 8(12), pp. 1427-1440.
    • (1997) Meas. Sci. Technol. , vol.8 , Issue.12 , pp. 1427-1440
    • Huang, H.1    Dabiri, D.2    Gharib, M.3
  • 46
    • 78249256652 scopus 로고    scopus 로고
    • Super spatio-temporal resolution, digital, PIV system for multi-phase flows with phase differentiation and simultaneous shape and size quantification
    • New Orleans, LA, Nov. 17-22
    • Abiven, C., and Vlachos, P. P., 2002, "Super Spatio-Temporal Resolution, Digital, PIV System for Multi-Phase Flows with Phase Differentiation and Simultaneous Shape and Size Quantification," ASME International Mechanical Engineering Congress and Exposition (IMECE)-33170, New Orleans, LA, Nov. 17-22.
    • (2002) ASME International Mechanical Engineering Congress and Exposition (IMECE)-33170
    • Abiven, C.1    Vlachos, P.P.2
  • 47
    • 0031111692 scopus 로고    scopus 로고
    • The non-invasive assessment of left verticula diastolin function with two-dimensional and doppler echocardiography
    • Oh, J. K., Appleton, C. P., Halle, L. K., Nishimura, R. A., Seward, J. B., and Tajik, A. J., 1997, "The Non-Invasive Assessment of Left Verticula Diastolin Function With Two-Dimensional and Doppler Echocardiography," J. Am. Soc. Echocardiogr, 10, pp. 246-270.
    • (1997) J. Am. Soc. Echocardiogr , vol.10 , pp. 246-270
    • Oh, J.K.1    Appleton, C.P.2    Halle, L.K.3    Nishimura, R.A.4    Seward, J.B.5    Tajik, A.J.6
  • 48
    • 0035028850 scopus 로고    scopus 로고
    • Evolution of prosthetic heart valves
    • Edmunds, and Henry, I., 2001, "Evolution of Prosthetic Heart Valves," Am. Heart J., 141, pp. 849-855.
    • (2001) Am. Heart J. , vol.141 , pp. 849-855
    • Edmunds1    Henry, I.2
  • 49
    • 28044461521 scopus 로고    scopus 로고
    • Improvements on the accuracey of derivative estimation from DPIV veloicity measurements
    • Etebari, A., and Vlachos, P., 2005, "Improvements on the Accuracey of Derivative Estimation From DPIV Veloicity Measurements," Exp. Fluids, 39(6), pp.
    • (2005) Exp. Fluids , vol.39 , Issue.6
    • Etebari, A.1    Vlachos, P.2
  • 50
    • 0034079173 scopus 로고    scopus 로고
    • Energy and velocity of a forming vortex ring
    • Shusser, M., and Gharib, M., 2000, "Energy and Velocity of a Forming Vortex Ring," Phys. Fluids, 12(3), pp. 618-622.
    • (2000) Phys. Fluids , vol.12 , Issue.3 , pp. 618-622
    • Shusser, M.1    Gharib, M.2
  • 51
    • 0021599284 scopus 로고    scopus 로고
    • John Wiley & Sons, Inc., New York
    • Panton Ronald, L., 1996, Incompressible Flow, John Wiley & Sons, Inc., New York.
    • (1996) Incompressible Flow
    • Panton, R.L.1
  • 52
    • 14844284559 scopus 로고    scopus 로고
    • An objective definition of a vortex
    • Haller, G., 2005, "An Objective Definition of a Vortex," J. Fluid Mech., 525, pp. 1-26.
    • (2005) J. Fluid Mech. , vol.525 , pp. 1-26
    • Haller, G.1
  • 53
    • 0029252670 scopus 로고
    • On the identification of a vortex
    • Jeong, J., and Hussain, F., 1995, "On the Identification of a Vortex," J. Fluid Mech., 285, pp. 69-94.
    • (1995) J. Fluid Mech. , vol.285 , pp. 69-94
    • Jeong, J.1    Hussain, F.2
  • 55
    • 0024119081 scopus 로고
    • Hydrodynamic function of ten prosthetic heart valves in the aortic position
    • Fisher, J., and Wheatley, D. J., 1988, "Hydrodynamic Function of Ten Prosthetic Heart Valves in the Aortic Position," Clin. Phys. Physiol. Meas., 9(4), pp. 307-317.
    • (1988) Clin. Phys. Physiol. Meas. , vol.9 , Issue.4 , pp. 307-317
    • Fisher, J.1    Wheatley, D.J.2
  • 57
    • 0042326239 scopus 로고    scopus 로고
    • Vortex ring pinch-off in the presence of simultaneously initiated uniform background co-flow
    • Krueger, P., Dabiri, J., and Gharib, M., 2003, "Vortex Ring Pinch-off in the Presence of Simultaneously Initiated Uniform Background Co-flow," Phys. Fluids, 15(7), pp. 49-52.
    • (2003) Phys. Fluids , vol.15 , Issue.7 , pp. 49-52
    • Krueger, P.1    Dabiri, J.2    Gharib, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.