메뉴 건너뛰기




Volumn 15, Issue 9, 2005, Pages 1959-1968

Assessment of image quality of a standard and three dose-reducing protocols in adult cranial CT

Author keywords

Head; Radiation dosage; X ray computed tomography

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; BASAL GANGLION; CEREBELLUM; CLINICAL PROTOCOL; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; CORRELATION ANALYSIS; DOSIMETRY; FEMALE; HEAD CIRCUMFERENCE; HUMAN; IMAGE ANALYSIS; IMAGE QUALITY; MAJOR CLINICAL STUDY; MALE; NEUROIMAGING; PRIORITY JOURNAL; PROCESS OPTIMIZATION; QUANTITATIVE ANALYSIS; SCORING SYSTEM; SIGNAL NOISE RATIO;

EID: 24044514660     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00330-004-2550-7     Document Type: Article
Times cited : (14)

References (15)
  • 2
    • 0030732612 scopus 로고    scopus 로고
    • CT standard protocols are of limited value in assessing actual patient dose
    • 1:STN:280:DyaK1c7psl2ktg%3D%3D
    • Wade JP, Weyman JC, Goldstone KE (1997) CT standard protocols are of limited value in assessing actual patient dose. Br J Radiol 70:1146-1151 1:STN:280:DyaK1c7psl2ktg%3D%3D
    • (1997) Br. J. Radiol. , vol.70 , pp. 1146-1151
    • Wade, J.P.1    Weyman, J.C.2    Goldstone, K.E.3
  • 3
  • 4
    • 0042132003 scopus 로고    scopus 로고
    • Comparison of low-dose and standard-dose helical CT in the evaluation of pulmonary nodules
    • 12386771
    • Karabulut N, Toru M, Gelebek V, Gulsun M, Ariyurek OM (2002) Comparison of low-dose and standard-dose helical CT in the evaluation of pulmonary nodules. Eur Radiol 12:2764-2769 12386771
    • (2002) Eur. Radiol. , vol.12 , pp. 2764-2769
    • Karabulut, N.1    Toru, M.2    Gelebek, V.3    Gulsun, M.4    Ariyurek, O.M.5
  • 5
    • 0035198909 scopus 로고    scopus 로고
    • A rational approach to dose reduction in CT: Individualized scan protocols
    • 10.1007/s003300101039
    • Wilting JE, Zwartkruis A, van Leeuwen MS et al (2001) A rational approach to dose reduction in CT: Individualized scan protocols. Eur Radiol 11:2627-2632 10.1007/s003300101039
    • (2001) Eur. Radiol. , vol.11 , pp. 2627-2632
    • Wilting, J.E.1    Zwartkruis, A.2    van Leeuwen, M.S.3
  • 6
    • 2542434100 scopus 로고    scopus 로고
    • Management of patient dose and image noise in routine pediatric CT abdominal examinations
    • 10.1007/s00330-003-2206-z
    • Verdun FR, Lepori D, Monnin P, Valley JF, Schnyder P, Gudinchet F (2004) Management of patient dose and image noise in routine pediatric CT abdominal examinations. Eur Radiol 14:835-8411 10.1007/s00330-003-2206-z
    • (2004) Eur. Radiol. , vol.14 , pp. 835-8411
    • Verdun, F.R.1    Lepori, D.2    Monnin, P.3    Valley, J.F.4    Schnyder, P.5    Gudinchet, F.6
  • 7
    • 0036839121 scopus 로고    scopus 로고
    • Clinical comparison of standard-dose and 50% reduced-dose abdominal CT: Effect on image quality
    • Kalra MK, Prasad S, Saini S et al (2002) Clinical comparison of standard-dose and 50% reduced-dose abdominal CT: Effect on image quality. Am J Roentgenol 179:1101-1106
    • (2002) Am. J. Roentgenol. , vol.179 , pp. 1101-1106
    • Kalra, M.K.1    Prasad, S.2    Saini, S.3
  • 8
    • 0033776724 scopus 로고    scopus 로고
    • CT of the head by use of reduced current and kilovoltage: Relationship between image quality and dose reduction
    • 1:STN:280:DC%2BD3cvovVertw%3D%3D
    • Cohnen M, Fischer H, Hamacher J et al (2000) CT of the head by use of reduced current and kilovoltage: Relationship between image quality and dose reduction. Am J Neuroradiol 21:1654-1660 1:STN:280:DC%2BD3cvovVertw%3D%3D
    • (2000) Am. J. Neuroradiol. , vol.21 , pp. 1654-1660
    • Cohnen, M.1    Fischer, H.2    Hamacher, J.3
  • 9
    • 0032870230 scopus 로고    scopus 로고
    • Radiation dose reduction in paediatric cranial CT
    • 10.1007/s002470050692
    • Chan CY, Wong YC, Chau LF, Yu SK, Lau PC (1999) Radiation dose reduction in paediatric cranial CT. Pediatr Radiol 29:770-775 10.1007/s002470050692
    • (1999) Pediatr. Radiol. , vol.29 , pp. 770-775
    • Chan, C.Y.1    Wong, Y.C.2    Chau, L.F.3    Yu, S.K.4    Lau, P.C.5
  • 10
    • 0036938688 scopus 로고    scopus 로고
    • Current adult and pediatric CT doses
    • 10.1007/s00247-002-0677-8
    • Nickoloff E (2002) Current adult and pediatric CT doses. Pediatr Radiol 32:250-260 10.1007/s00247-002-0677-8
    • (2002) Pediatr. Radiol. , vol.32 , pp. 250-260
    • Nickoloff, E.1
  • 11
    • 0031978536 scopus 로고    scopus 로고
    • Low-dose spiral computed tomography of the thorax: Comparison with the standard-dose technique
    • 10.1097/00004424-199802000-00002
    • Takahashi M, Maguire WM, Ashtari M et al (1998) Low-dose spiral computed tomography of the thorax: Comparison with the standard-dose technique. Invest Radiol 33:68-73 10.1097/00004424-199802000-00002
    • (1998) Invest. Radiol. , vol.33 , pp. 68-73
    • Takahashi, M.1    Maguire, W.M.2    Ashtari, M.3
  • 13
    • 0028204965 scopus 로고
    • Radiation dose reduction in CT of pediatric pelvis
    • 1:STN:280:ByuC2MbosFM%3D
    • Kamel RI, Hemandez JR, Martin EJ et al (1994) Radiation dose reduction in CT of pediatric pelvis. Radiology 190:683-687 1:STN:280:ByuC2MbosFM%3D
    • (1994) Radiology , vol.190 , pp. 683-687
    • Kamel, R.I.1    Hemandez, J.R.2    Martin, E.J.3
  • 15
    • 0036939215 scopus 로고    scopus 로고
    • CT dose parameters and their limitations
    • 10.1007/s00247-002-0676-9
    • Fearon T (2002) CT dose parameters and their limitations. Pediatr Radiol 32:246-249 10.1007/s00247-002-0676-9
    • (2002) Pediatr. Radiol. , vol.32 , pp. 246-249
    • Fearon, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.