메뉴 건너뛰기




Volumn 29, Issue 2, 2007, Pages 175-181

Loss in mechanical contact of cementless acetabular prostheses due to post-operative weight bearing: A biomechanical model

Author keywords

Biomechanics; Finite element model; Hip; Metal back; Primary stability; Prosthesis

Indexed keywords

BIOMECHANICS; BONE; COMPUTER SIMULATION; FINITE ELEMENT METHOD; INTERFACES (MATERIALS); MATHEMATICAL MODELS; PROSTHETICS; SURGERY; TRANSPLANTATION (SURGICAL);

EID: 37849188518     PISSN: 13504533     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.medengphy.2006.02.008     Document Type: Article
Times cited : (30)

References (38)
  • 1
    • 0028047426 scopus 로고
    • Osteolysis around uncemented acetabular components of cobalt-chrome surface replacement hip arthroplasty
    • Buechel F.F., Drucker D., Jasty M., Jiranek W., and Harris W.H. Osteolysis around uncemented acetabular components of cobalt-chrome surface replacement hip arthroplasty. Clin Orthop Relat Res 298 (1994) 202-211
    • (1994) Clin Orthop Relat Res , vol.298 , pp. 202-211
    • Buechel, F.F.1    Drucker, D.2    Jasty, M.3    Jiranek, W.4    Harris, W.H.5
  • 4
    • 0033029624 scopus 로고    scopus 로고
    • Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty
    • Sochart D.H. Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty. Clin Orthop Relat Res 363 (1999) 135-150
    • (1999) Clin Orthop Relat Res , vol.363 , pp. 135-150
    • Sochart, D.H.1
  • 5
    • 0030060376 scopus 로고    scopus 로고
    • Experimental study of periacetabular deformations before and after implantation of hip prosthesis
    • Massin P., Vandenbussche E., Landjerit B., and Augereau B. Experimental study of periacetabular deformations before and after implantation of hip prosthesis. J Biomech 29 (1996) 53-61
    • (1996) J Biomech , vol.29 , pp. 53-61
    • Massin, P.1    Vandenbussche, E.2    Landjerit, B.3    Augereau, B.4
  • 6
    • 0036787773 scopus 로고    scopus 로고
    • Load transfer and fixation mode of press-fit acetabular socket
    • Widmer K.H., Zurfluh B., and Morscher E.W. Load transfer and fixation mode of press-fit acetabular socket. J Arthroplasty 17 7 (2002) 926-935
    • (2002) J Arthroplasty , vol.17 , Issue.7 , pp. 926-935
    • Widmer, K.H.1    Zurfluh, B.2    Morscher, E.W.3
  • 7
    • 0020055897 scopus 로고
    • Stress distributions in the acetabular region. I. Before and after total joint replacement
    • Vasu R., Carter D.R., and Harris W.H. Stress distributions in the acetabular region. I. Before and after total joint replacement. J Biomech 15 (1982) 155-164
    • (1982) J Biomech , vol.15 , pp. 155-164
    • Vasu, R.1    Carter, D.R.2    Harris, W.H.3
  • 8
    • 0020038663 scopus 로고
    • Stress distributions in the acetabular region. II. Effect of cement thickness and metal backing of the total hip acetabular component
    • Carter D.R., Vasu R., and Harris W.H. Stress distributions in the acetabular region. II. Effect of cement thickness and metal backing of the total hip acetabular component. J Biomech 15 3 (1982) 165-170
    • (1982) J Biomech , vol.15 , Issue.3 , pp. 165-170
    • Carter, D.R.1    Vasu, R.2    Harris, W.H.3
  • 9
    • 0028070470 scopus 로고
    • Prestress around acetabulum generated by screwed cups
    • Dalstra M., and Huiskes R. Prestress around acetabulum generated by screwed cups. Clin Mater 16 3 (1994) 145-154
    • (1994) Clin Mater , vol.16 , Issue.3 , pp. 145-154
    • Dalstra, M.1    Huiskes, R.2
  • 10
    • 37949017625 scopus 로고    scopus 로고
    • Dalstra M. Biomechanical aspects of the pelvic bone and design criteria for acetabular prosthesis. Ph.D. Dissertation, University of Njemegen, The Netherlands, 1993:69-82.
  • 11
    • 37949036337 scopus 로고    scopus 로고
    • Dalstra M. Biomechanical aspects of the pelvic bone and design criteria for acetabular prosthesis. Ph.D. Dissertation, University of Njemegen, The Netherlands, 1993:97-110.
  • 12
    • 0034333770 scopus 로고    scopus 로고
    • Interfacial conditions between a press-fit acetabular cup and bone during daily activities: implications for achieving bone in-growth
    • Spears I.R., Pfleiderer M., Schneider E., Hille E., Bergmann G., and Morlock M.M. Interfacial conditions between a press-fit acetabular cup and bone during daily activities: implications for achieving bone in-growth. J Biomech 33 (2000) 1471-1477
    • (2000) J Biomech , vol.33 , pp. 1471-1477
    • Spears, I.R.1    Pfleiderer, M.2    Schneider, E.3    Hille, E.4    Bergmann, G.5    Morlock, M.M.6
  • 13
    • 0035217725 scopus 로고    scopus 로고
    • The effect of interfacial parameters on cup-bone relative micromotions. A finite element investigation
    • Spears I.R., Pfleiderer M., Schneider E., Hille E., and Morlock M.M. The effect of interfacial parameters on cup-bone relative micromotions. A finite element investigation. J Biomech 34 (2001) 113-120
    • (2001) J Biomech , vol.34 , pp. 113-120
    • Spears, I.R.1    Pfleiderer, M.2    Schneider, E.3    Hille, E.4    Morlock, M.M.5
  • 14
    • 0242719258 scopus 로고
    • Acetabular component interface: press-fit fixation
    • Yerby S.A., Taylor J.K., and Murzic W. Acetabular component interface: press-fit fixation. Trans Orthop Res Soc 17 (1992) 384
    • (1992) Trans Orthop Res Soc , vol.17 , pp. 384
    • Yerby, S.A.1    Taylor, J.K.2    Murzic, W.3
  • 15
    • 0028153815 scopus 로고
    • Areas of contact and extent of gaps with implantation of oversized acetabular components in total hip arthroplasty
    • MacKenzie J.R., Callaghan J.J., Pedersen D.R., and Brown T.D. Areas of contact and extent of gaps with implantation of oversized acetabular components in total hip arthroplasty. Clin Orthop Relat Res 298 (1994) 127-136
    • (1994) Clin Orthop Relat Res , vol.298 , pp. 127-136
    • MacKenzie, J.R.1    Callaghan, J.J.2    Pedersen, D.R.3    Brown, T.D.4
  • 16
    • 0028329831 scopus 로고
    • A quantitative in vitro assessment of fit and screw fixation on the stability of a cementless hemispherical acetabular component
    • Kwong L.M., O'Connor D.O., Sedlacek R.C., Krushell R.J., Maloney W.J., and Harris W.H. A quantitative in vitro assessment of fit and screw fixation on the stability of a cementless hemispherical acetabular component. J Arthroplasty 9 2 (1994) 163-170
    • (1994) J Arthroplasty , vol.9 , Issue.2 , pp. 163-170
    • Kwong, L.M.1    O'Connor, D.O.2    Sedlacek, R.C.3    Krushell, R.J.4    Maloney, W.J.5    Harris, W.H.6
  • 17
    • 0020068498 scopus 로고
    • An axisymmetric model of acetabular components in total hip arthroplasty
    • Pedersen D.R., Crowninshield R.D., Brand R.A., and Johnston R.C. An axisymmetric model of acetabular components in total hip arthroplasty. J Biomech 15 4 (1982) 305-315
    • (1982) J Biomech , vol.15 , Issue.4 , pp. 305-315
    • Pedersen, D.R.1    Crowninshield, R.D.2    Brand, R.A.3    Johnston, R.C.4
  • 18
    • 0020961418 scopus 로고
    • Mechanical analysis of the human pelvis and its application to the artificial hip joint-by means of the three-dimensional finite element method
    • Oonishi H., Isha H., and Hasegawa T. Mechanical analysis of the human pelvis and its application to the artificial hip joint-by means of the three-dimensional finite element method. J Biomech 16 6 (1983) 427-444
    • (1983) J Biomech , vol.16 , Issue.6 , pp. 427-444
    • Oonishi, H.1    Isha, H.2    Hasegawa, T.3
  • 19
    • 0026442786 scopus 로고
    • The Harris-Galante porous-coated acetabular component with screw fixation. Radiographic analysis of eighty-three primary hip replacements at a minimum of five years
    • Schmalzried T.P., and Harris W.H. The Harris-Galante porous-coated acetabular component with screw fixation. Radiographic analysis of eighty-three primary hip replacements at a minimum of five years. J Bone Joint Surg Am 74 8 (1992) 1130-1139
    • (1992) J Bone Joint Surg Am , vol.74 , Issue.8 , pp. 1130-1139
    • Schmalzried, T.P.1    Harris, W.H.2
  • 20
    • 0027579804 scopus 로고
    • Mechanical and textural properties of pelvic trabecular bone
    • Dalstra M., Huiskes R., Odgaard A., and van Erning L. Mechanical and textural properties of pelvic trabecular bone. J Biomech 26 4-5 (1993) 522-535
    • (1993) J Biomech , vol.26 , Issue.4-5 , pp. 522-535
    • Dalstra, M.1    Huiskes, R.2    Odgaard, A.3    van Erning, L.4
  • 21
    • 0029347550 scopus 로고
    • Development and validation of a three-dimensional finite element model of the pelvic bone
    • Dalstra M., Huiskes R., Odgaard A., and van Erning L. Development and validation of a three-dimensional finite element model of the pelvic bone. J Biomech Eng 117 3 (1995) 272-278
    • (1995) J Biomech Eng , vol.117 , Issue.3 , pp. 272-278
    • Dalstra, M.1    Huiskes, R.2    Odgaard, A.3    van Erning, L.4
  • 22
    • 0022793384 scopus 로고    scopus 로고
    • Kunstoffe in der Gelenkendoprothetik
    • Eyerer P. Kunstoffe in der Gelenkendoprothetik. Z Werkstofftech 17 (1996) 384-391
    • (1996) Z Werkstofftech , vol.17 , pp. 384-391
    • Eyerer, P.1
  • 23
    • 0032212854 scopus 로고    scopus 로고
    • The yielding, plastic flow, and fracture behaviour of ultra-high molecular weight polyethylene used in total joint replacement
    • Kurtz S.M., Pruit L., Jewett C.W., Crawford R.P., Crane D.J., and Edinin A.A. The yielding, plastic flow, and fracture behaviour of ultra-high molecular weight polyethylene used in total joint replacement. Biomaterials 19 21 (1998) 1989-2003
    • (1998) Biomaterials , vol.19 , Issue.21 , pp. 1989-2003
    • Kurtz, S.M.1    Pruit, L.2    Jewett, C.W.3    Crawford, R.P.4    Crane, D.J.5    Edinin, A.A.6
  • 25
    • 0026821443 scopus 로고
    • Experimental determination of friction characteristics at the trabecular bone/porous coated metal interface in cementless implants
    • Shirazi-Adl A., Dammak M., and Paiement G. Experimental determination of friction characteristics at the trabecular bone/porous coated metal interface in cementless implants. J Biomed Mater Res 27 2 (1993) 167-175
    • (1993) J Biomed Mater Res , vol.27 , Issue.2 , pp. 167-175
    • Shirazi-Adl, A.1    Dammak, M.2    Paiement, G.3
  • 28
    • 0020824349 scopus 로고
    • A physiologically based criterion of muscle force prediction in locomotion
    • Crowninshield R.D., and Brand R.A. A physiologically based criterion of muscle force prediction in locomotion. J Biomech 43 2 (1981) 164-170
    • (1981) J Biomech , vol.43 , Issue.2 , pp. 164-170
    • Crowninshield, R.D.1    Brand, R.A.2
  • 29
    • 0019777563 scopus 로고
    • A three-dimensional biomechanical model of hip musculature
    • Dostal W.F., and Andrews J.G. A three-dimensional biomechanical model of hip musculature. J Biomech 14 11 (1981) 803-812
    • (1981) J Biomech , vol.14 , Issue.11 , pp. 803-812
    • Dostal, W.F.1    Andrews, J.G.2
  • 30
    • 0029310682 scopus 로고
    • Load transfer across the pelvic bone
    • Dalstra M., and Huiskes R. Load transfer across the pelvic bone. J Biomech 28 6 (1995) 715-724
    • (1995) J Biomech , vol.28 , Issue.6 , pp. 715-724
    • Dalstra, M.1    Huiskes, R.2
  • 31
    • 0022353611 scopus 로고
    • Contact finite element stress analysis of the hip joint
    • Rapperport D.J., Carter D.R., and Schurman D.J. Contact finite element stress analysis of the hip joint. J Orthop Res 3 (1985) 435-446
    • (1985) J Orthop Res , vol.3 , pp. 435-446
    • Rapperport, D.J.1    Carter, D.R.2    Schurman, D.J.3
  • 32
    • 0022929719 scopus 로고
    • Pelvic stresses in vitro. I. Malsizing of endoprostheses
    • Finlay J.B., Bourne R.B., Landsberg R.P.D., and Andrea P. Pelvic stresses in vitro. I. Malsizing of endoprostheses. J Biomech 19 (1986) 703-714
    • (1986) J Biomech , vol.19 , pp. 703-714
    • Finlay, J.B.1    Bourne, R.B.2    Landsberg, R.P.D.3    Andrea, P.4
  • 33
    • 0024942676 scopus 로고
    • Cortical pelvic strains with varying size hemiarthroplasty in vitro
    • Ries M., Pugh J., Au J.C., Gurtowski J., and Dee R. Cortical pelvic strains with varying size hemiarthroplasty in vitro. J Biomech 22 (1989) 775-780
    • (1989) J Biomech , vol.22 , pp. 775-780
    • Ries, M.1    Pugh, J.2    Au, J.C.3    Gurtowski, J.4    Dee, R.5
  • 34
    • 0031012948 scopus 로고    scopus 로고
    • Acetabular strains produced by oversized press-fit cups
    • Ries M., and Harbaugh M. Acetabular strains produced by oversized press-fit cups. Clin Orthop Relat Res 334 (1997) 276-281
    • (1997) Clin Orthop Relat Res , vol.334 , pp. 276-281
    • Ries, M.1    Harbaugh, M.2
  • 35
    • 0031029829 scopus 로고    scopus 로고
    • Effect of cementless acetabular cup geometry on strain distribution and press-fit stability
    • Ries M., Harbaugh M., Shea J., and Lambert R. Effect of cementless acetabular cup geometry on strain distribution and press-fit stability. J Arthroplasty 12 (1997) 207-212
    • (1997) J Arthroplasty , vol.12 , pp. 207-212
    • Ries, M.1    Harbaugh, M.2    Shea, J.3    Lambert, R.4
  • 37
    • 0036213883 scopus 로고    scopus 로고
    • Impact biomechanics and pelvic deformation during insertion of press-fit acetabular cups
    • Kroeber M., Ries M.D., Suzuki Y., Renowitzky G., Ashford F., and Lotz J. Impact biomechanics and pelvic deformation during insertion of press-fit acetabular cups. J Arthroplasty 17 3 (2002) 349-354
    • (2002) J Arthroplasty , vol.17 , Issue.3 , pp. 349-354
    • Kroeber, M.1    Ries, M.D.2    Suzuki, Y.3    Renowitzky, G.4    Ashford, F.5    Lotz, J.6
  • 38
    • 0026581886 scopus 로고
    • Das zeitliche Verhalten der Verankerung einer zementfrei implantierten Hueftpfanne im Tierversuch
    • Bereiter H., Buergi M., and Rahn B.A. Das zeitliche Verhalten der Verankerung einer zementfrei implantierten Hueftpfanne im Tierversuch. Orthopaede 21 (1992) 63-70
    • (1992) Orthopaede , vol.21 , pp. 63-70
    • Bereiter, H.1    Buergi, M.2    Rahn, B.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.