-
2
-
-
0020691233
-
Periacetabular stress distributions after joint replacement with subchondral bone retention
-
Carter DR, Vasu R, Harris WH: Periacetabular stress distributions after joint replacement with subchondral bone retention. Acta Orthop Scand 54:29-35, 1983.
-
(1983)
Acta Orthop Scand
, vol.54
, pp. 29-35
-
-
Carter, D.R.1
Vasu, R.2
Harris, W.H.3
-
3
-
-
0020586670
-
A stress analysis of acetabular reconstruction in protrusio acetabuli
-
Crowninshield RD, Brand RA, Pedersen DR: A stress analysis of acetabular reconstruction in protrusio acetabuli. J Bone Joint Surg 65A:495-499, 1983.
-
(1983)
J Bone Joint Surg
, vol.65 A
, pp. 495-499
-
-
Crowninshield, R.D.1
Brand, R.A.2
Pedersen, D.R.3
-
4
-
-
0026571837
-
The initial stability of uncemented acetabular components
-
Curtis MJ, Jinnah RH, Wilson VD, Hungerford DS: The initial stability of uncemented acetabular components. J Bone Joint Surg 74B:372-376, 1942.
-
(1942)
J Bone Joint Surg
, vol.74 B
, pp. 372-376
-
-
Curtis, M.J.1
Jinnah, R.H.2
Wilson, V.D.3
Hungerford, D.S.4
-
5
-
-
0022929719
-
Pelvic stresses in vitro - I. Malsizing of endoprostheses
-
Finlay JB, Bourne RB, Landsberg RPD, Andrea P: Pelvic stresses in vitro - I. Malsizing of endoprostheses. J Biomech 19:703-714, 1986.
-
(1986)
J Biomech
, vol.19
, pp. 703-714
-
-
Finlay, J.B.1
Bourne, R.B.2
Landsberg, R.P.D.3
Andrea, P.4
-
6
-
-
0023547272
-
Finite element analysis of acetabular reconstruction. Non-cemented threaded cups
-
Huiskes R: Finite element analysis of acetabular reconstruction. Non-cemented threaded cups. Acta Orthop Scand 58:620-625, 1987.
-
(1987)
Acta Orthop Scand
, vol.58
, pp. 620-625
-
-
Huiskes, R.1
-
7
-
-
0342528301
-
Seating of hemispherical vs. dual radius components in press-fit cementless acetabular fixation
-
Kim YS, Brown TD, Pedersen DR, Callaghan JJ: Seating of hemispherical vs. dual radius components in press-fit cementless acetabular fixation. Transactions of the Orthopaedic Research Society 20:722, 1995.
-
(1995)
Transactions of the Orthopaedic Research Society
, vol.20
, pp. 722
-
-
Kim, Y.S.1
Brown, T.D.2
Pedersen, D.R.3
Callaghan, J.J.4
-
8
-
-
0028153815
-
Areas of contact and extent of gaps with implantation of oversized acetabular components in total hip arthroplasty
-
MacKenzie JR, Callaghan JJ, Pedersen DR, Brown TD: Areas of contact and extent of gaps with implantation of oversized acetabular components in total hip arthroplasty. Clin Orthop 298:127-136, 1994.
-
(1994)
Clin Orthop
, vol.298
, pp. 127-136
-
-
MacKenzie, J.R.1
Callaghan, J.J.2
Pedersen, D.R.3
Brown, T.D.4
-
9
-
-
0024956607
-
Cementless press-fit cup. Principles, experimental data, and three-year follow-up study
-
Morscher E, Bereiter H, Lampert C: Cementless press-fit cup. Principles, experimental data, and three-year follow-up study. Clin Orthop 249:12-20, 1989.
-
(1989)
Clin Orthop
, vol.249
, pp. 12-20
-
-
Morscher, E.1
Bereiter, H.2
Lampert, C.3
-
10
-
-
0020961418
-
Mechanical analysis of the human pelvis and its application to the artificial hip joining by means of the three-dimensional finite element method
-
Oonishi H, Isha H, Hasegawa T: Mechanical analysis of the human pelvis and its application to the artificial hip joining by means of the three-dimensional finite element method. J Biomech 16:427-444, 1983.
-
(1983)
J Biomech
, vol.16
, pp. 427-444
-
-
Oonishi, H.1
Isha, H.2
Hasegawa, T.3
-
11
-
-
0026228546
-
Alterations in femoral and acetabular bone strains immediately following cementless total hip arthroplasty: An in vitro canine study
-
Page A, Jasty M, Bragdon C, Ito K, Harris WH: Alterations in femoral and acetabular bone strains immediately following cementless total hip arthroplasty: An in vitro canine study. J Orthop Res 9:738-748, 1991.
-
(1991)
J Orthop Res
, vol.9
, pp. 738-748
-
-
Page, A.1
Jasty, M.2
Bragdon, C.3
Ito, K.4
Harris, W.H.5
-
12
-
-
0015592803
-
Mechanical properties of bone as a function of rate of deformation
-
Panjabi MM, White AA: Mechanical properties of bone as a function of rate of deformation. J Bone Joint Surg 55A:322-330, 1973.
-
(1973)
J Bone Joint Surg
, vol.55 A
, pp. 322-330
-
-
Panjabi, M.M.1
White, A.A.2
-
13
-
-
0020068498
-
An axisymmetric model of acetabular components in total hip arthroplasty
-
Pedersen DR, Crowninshield RD, Brand RA, Johnston RC: An axisymmetric model of acetabular components in total hip arthroplasty. J Biomech 15:305-315, 1982.
-
(1982)
J Biomech
, vol.15
, pp. 305-315
-
-
Pedersen, D.R.1
Crowninshield, R.D.2
Brand, R.A.3
Johnston, R.C.4
-
15
-
-
0024731153
-
Normal pelvic strain pattern in vitro
-
Ries M, Pugh J, Au JC, Gurtowski J, Dee R: Normal pelvic strain pattern in vitro. J Biomed Eng 11:398-402, 1989.
-
(1989)
J Biomed Eng
, vol.11
, pp. 398-402
-
-
Ries, M.1
Pugh, J.2
Au, J.C.3
Gurtowski, J.4
Dee, R.5
-
16
-
-
0024942676
-
Cortical pelvic strains with varying size hemiarthroplasty in vitro
-
Ries M, Pugh J, Au JC, Gurtowski J, Dee R: Cortical pelvic strains with varying size hemiarthroplasty in vitro. J Biomech 22:775-780, 1989.
-
(1989)
J Biomech
, vol.22
, pp. 775-780
-
-
Ries, M.1
Pugh, J.2
Au, J.C.3
Gurtowski, J.4
Dee, R.5
-
17
-
-
0026442786
-
The Harris-Galante porous-coated acetabular component with screw fixation
-
Schmalzried TP, Harris WH: The Harris-Galante porous-coated acetabular component with screw fixation J Bone Joint Surg 74A:1130-1139, 1992.
-
(1992)
J Bone Joint Surg
, vol.74 A
, pp. 1130-1139
-
-
Schmalzried, T.P.1
Harris, W.H.2
-
18
-
-
0027264739
-
Evaluation of initial surface apposition in porous-coated acetabular components
-
Schwartz JT, Engh CA, Forte MR, Kukita Y, Grandia SK: Evaluation of initial surface apposition in porous-coated acetabular components. Clin Orthop 293:174-187, 1993.
-
(1993)
Clin Orthop
, vol.293
, pp. 174-187
-
-
Schwartz, J.T.1
Engh, C.A.2
Forte, M.R.3
Kukita, Y.4
Grandia, S.K.5
-
19
-
-
0026821443
-
Experimental determination of friction characteristics at the trabecular bone/porous-coated metal interface in cementless implants
-
Shirazi-Adl A, Dammak M, Paiement G: Experimental determination of friction characteristics at the trabecular bone/porous-coated metal interface in cementless implants. J Biomed Mater Res 27:167-175, 1993.
-
(1993)
J Biomed Mater Res
, vol.27
, pp. 167-175
-
-
Shirazi-Adl, A.1
Dammak, M.2
Paiement, G.3
-
20
-
-
0020055897
-
Stress distribution in the acetabular region - I. before and after total joint replacement
-
Vasu R, Carter DR, Harris WH: Stress distribution in the acetabular region - I. Before and after total joint replacement. J Biomech 15:155-164, 1982.
-
(1982)
J Biomech
, vol.15
, pp. 155-164
-
-
Vasu, R.1
Carter, D.R.2
Harris, W.H.3
-
21
-
-
0029004699
-
Micromotion of cementless hemispherical acetabular components
-
Won CH, Hearn TC, Tile M: Micromotion of cementless hemispherical acetabular components. J Bone Joint Surg 77B:484-489, 1995.
-
(1995)
J Bone Joint Surg
, vol.77 B
, pp. 484-489
-
-
Won, C.H.1
Hearn, T.C.2
Tile, M.3
|