메뉴 건너뛰기




Volumn 334, Issue , 1997, Pages 276-281

Acetabular strains produced by oversized press fit cups

Author keywords

[No Author keywords available]

Indexed keywords

ACETABULUM; ARTICLE; BIOMECHANICS; BONE DEFORMATION; CALCULATION; FINITE ELEMENT ANALYSIS; GEOMETRY; MATHEMATICAL MODEL; PELVIS FRACTURE; PRIORITY JOURNAL; RIGIDITY; YOUNG MODULUS;

EID: 0031012948     PISSN: 0009921X     EISSN: 15281132     Source Type: Journal    
DOI: 10.1097/00003086-199701000-00036     Document Type: Article
Times cited : (33)

References (21)
  • 2
    • 0020691233 scopus 로고
    • Periacetabular stress distributions after joint replacement with subchondral bone retention
    • Carter DR, Vasu R, Harris WH: Periacetabular stress distributions after joint replacement with subchondral bone retention. Acta Orthop Scand 54:29-35, 1983.
    • (1983) Acta Orthop Scand , vol.54 , pp. 29-35
    • Carter, D.R.1    Vasu, R.2    Harris, W.H.3
  • 3
    • 0020586670 scopus 로고
    • A stress analysis of acetabular reconstruction in protrusio acetabuli
    • Crowninshield RD, Brand RA, Pedersen DR: A stress analysis of acetabular reconstruction in protrusio acetabuli. J Bone Joint Surg 65A:495-499, 1983.
    • (1983) J Bone Joint Surg , vol.65 A , pp. 495-499
    • Crowninshield, R.D.1    Brand, R.A.2    Pedersen, D.R.3
  • 6
    • 0023547272 scopus 로고
    • Finite element analysis of acetabular reconstruction. Non-cemented threaded cups
    • Huiskes R: Finite element analysis of acetabular reconstruction. Non-cemented threaded cups. Acta Orthop Scand 58:620-625, 1987.
    • (1987) Acta Orthop Scand , vol.58 , pp. 620-625
    • Huiskes, R.1
  • 8
    • 0028153815 scopus 로고
    • Areas of contact and extent of gaps with implantation of oversized acetabular components in total hip arthroplasty
    • MacKenzie JR, Callaghan JJ, Pedersen DR, Brown TD: Areas of contact and extent of gaps with implantation of oversized acetabular components in total hip arthroplasty. Clin Orthop 298:127-136, 1994.
    • (1994) Clin Orthop , vol.298 , pp. 127-136
    • MacKenzie, J.R.1    Callaghan, J.J.2    Pedersen, D.R.3    Brown, T.D.4
  • 9
    • 0024956607 scopus 로고
    • Cementless press-fit cup. Principles, experimental data, and three-year follow-up study
    • Morscher E, Bereiter H, Lampert C: Cementless press-fit cup. Principles, experimental data, and three-year follow-up study. Clin Orthop 249:12-20, 1989.
    • (1989) Clin Orthop , vol.249 , pp. 12-20
    • Morscher, E.1    Bereiter, H.2    Lampert, C.3
  • 10
    • 0020961418 scopus 로고
    • Mechanical analysis of the human pelvis and its application to the artificial hip joining by means of the three-dimensional finite element method
    • Oonishi H, Isha H, Hasegawa T: Mechanical analysis of the human pelvis and its application to the artificial hip joining by means of the three-dimensional finite element method. J Biomech 16:427-444, 1983.
    • (1983) J Biomech , vol.16 , pp. 427-444
    • Oonishi, H.1    Isha, H.2    Hasegawa, T.3
  • 11
    • 0026228546 scopus 로고
    • Alterations in femoral and acetabular bone strains immediately following cementless total hip arthroplasty: An in vitro canine study
    • Page A, Jasty M, Bragdon C, Ito K, Harris WH: Alterations in femoral and acetabular bone strains immediately following cementless total hip arthroplasty: An in vitro canine study. J Orthop Res 9:738-748, 1991.
    • (1991) J Orthop Res , vol.9 , pp. 738-748
    • Page, A.1    Jasty, M.2    Bragdon, C.3    Ito, K.4    Harris, W.H.5
  • 12
    • 0015592803 scopus 로고
    • Mechanical properties of bone as a function of rate of deformation
    • Panjabi MM, White AA: Mechanical properties of bone as a function of rate of deformation. J Bone Joint Surg 55A:322-330, 1973.
    • (1973) J Bone Joint Surg , vol.55 A , pp. 322-330
    • Panjabi, M.M.1    White, A.A.2
  • 13
    • 0020068498 scopus 로고
    • An axisymmetric model of acetabular components in total hip arthroplasty
    • Pedersen DR, Crowninshield RD, Brand RA, Johnston RC: An axisymmetric model of acetabular components in total hip arthroplasty. J Biomech 15:305-315, 1982.
    • (1982) J Biomech , vol.15 , pp. 305-315
    • Pedersen, D.R.1    Crowninshield, R.D.2    Brand, R.A.3    Johnston, R.C.4
  • 14
    • 0022353611 scopus 로고
    • Contact finite element stress analysis of the hip joint
    • Rapperport DJ, Carter DR, Schurman DJ: Contact finite element stress analysis of the hip joint. J Orthop Res 3:435-446, 1985.
    • (1985) J Orthop Res , vol.3 , pp. 435-446
    • Rapperport, D.J.1    Carter, D.R.2    Schurman, D.J.3
  • 16
    • 0024942676 scopus 로고
    • Cortical pelvic strains with varying size hemiarthroplasty in vitro
    • Ries M, Pugh J, Au JC, Gurtowski J, Dee R: Cortical pelvic strains with varying size hemiarthroplasty in vitro. J Biomech 22:775-780, 1989.
    • (1989) J Biomech , vol.22 , pp. 775-780
    • Ries, M.1    Pugh, J.2    Au, J.C.3    Gurtowski, J.4    Dee, R.5
  • 17
    • 0026442786 scopus 로고
    • The Harris-Galante porous-coated acetabular component with screw fixation
    • Schmalzried TP, Harris WH: The Harris-Galante porous-coated acetabular component with screw fixation J Bone Joint Surg 74A:1130-1139, 1992.
    • (1992) J Bone Joint Surg , vol.74 A , pp. 1130-1139
    • Schmalzried, T.P.1    Harris, W.H.2
  • 18
    • 0027264739 scopus 로고
    • Evaluation of initial surface apposition in porous-coated acetabular components
    • Schwartz JT, Engh CA, Forte MR, Kukita Y, Grandia SK: Evaluation of initial surface apposition in porous-coated acetabular components. Clin Orthop 293:174-187, 1993.
    • (1993) Clin Orthop , vol.293 , pp. 174-187
    • Schwartz, J.T.1    Engh, C.A.2    Forte, M.R.3    Kukita, Y.4    Grandia, S.K.5
  • 19
    • 0026821443 scopus 로고
    • Experimental determination of friction characteristics at the trabecular bone/porous-coated metal interface in cementless implants
    • Shirazi-Adl A, Dammak M, Paiement G: Experimental determination of friction characteristics at the trabecular bone/porous-coated metal interface in cementless implants. J Biomed Mater Res 27:167-175, 1993.
    • (1993) J Biomed Mater Res , vol.27 , pp. 167-175
    • Shirazi-Adl, A.1    Dammak, M.2    Paiement, G.3
  • 20
    • 0020055897 scopus 로고
    • Stress distribution in the acetabular region - I. before and after total joint replacement
    • Vasu R, Carter DR, Harris WH: Stress distribution in the acetabular region - I. Before and after total joint replacement. J Biomech 15:155-164, 1982.
    • (1982) J Biomech , vol.15 , pp. 155-164
    • Vasu, R.1    Carter, D.R.2    Harris, W.H.3
  • 21
    • 0029004699 scopus 로고
    • Micromotion of cementless hemispherical acetabular components
    • Won CH, Hearn TC, Tile M: Micromotion of cementless hemispherical acetabular components. J Bone Joint Surg 77B:484-489, 1995.
    • (1995) J Bone Joint Surg , vol.77 B , pp. 484-489
    • Won, C.H.1    Hearn, T.C.2    Tile, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.