메뉴 건너뛰기




Volumn 26, Issue 1, 2008, Pages 109-116

Single-point imaging with a variable phase encoding interval

Author keywords

Magnetic resonance imaging; Phase encoding; Single point imaging; Variable time

Indexed keywords

ARTICLE; CALCULATION; IMAGE ANALYSIS; IMAGE RECONSTRUCTION; INFORMATION PROCESSING; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; SIGNAL NOISE RATIO; SIMULATION;

EID: 37349105608     PISSN: 0730725X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.mri.2007.05.004     Document Type: Article
Times cited : (17)

References (16)
  • 2
    • 0035034312 scopus 로고    scopus 로고
    • Accurate phosphorus metabolite images of the human heart by 3D acquisition-weighted CSI
    • Pohmann R., and von Kienlin M. Accurate phosphorus metabolite images of the human heart by 3D acquisition-weighted CSI. Magn Reson Med 45 (2001) 817-826
    • (2001) Magn Reson Med , vol.45 , pp. 817-826
    • Pohmann, R.1    von Kienlin, M.2
  • 3
    • 0033257486 scopus 로고    scopus 로고
    • In vivo triple quantum filtered twisted projection sodium MRI of human articular cartilage
    • Borthakur A., Hancu I., Boada F.E., Shen G.X., Shapiro E.M., and Reddy R. In vivo triple quantum filtered twisted projection sodium MRI of human articular cartilage. J Magn Reson 141 (1999) 286-290
    • (1999) J Magn Reson , vol.141 , pp. 286-290
    • Borthakur, A.1    Hancu, I.2    Boada, F.E.3    Shen, G.X.4    Shapiro, E.M.5    Reddy, R.6
  • 4
    • 0037925188 scopus 로고    scopus 로고
    • Density of organic matrix of native mineralized bone measured by water- and fat-suppressed proton projection MRI
    • Wu Y., Ackerman J.L., Chesler D.A., Graham L., Wang Y., and Glimcher M.J. Density of organic matrix of native mineralized bone measured by water- and fat-suppressed proton projection MRI. MRM Med Risk Manag 50 (2003) 59-68
    • (2003) MRM Med Risk Manag , vol.50 , pp. 59-68
    • Wu, Y.1    Ackerman, J.L.2    Chesler, D.A.3    Graham, L.4    Wang, Y.5    Glimcher, M.J.6
  • 6
    • 12844278117 scopus 로고    scopus 로고
    • Ultrashort TE chemical shift imaging (UTE-CSI)
    • Robson M.D., Tyler D.J., and Neubauer S. Ultrashort TE chemical shift imaging (UTE-CSI). MRM Med Risk Manag 53 (2005) 267-274
    • (2005) MRM Med Risk Manag , vol.53 , pp. 267-274
    • Robson, M.D.1    Tyler, D.J.2    Neubauer, S.3
  • 7
    • 0021850318 scopus 로고
    • High resolution NMR imaging in solids
    • Emid S., and Creyghton J.H.N. High resolution NMR imaging in solids. Physica B 128 (1985) 81-83
    • (1985) Physica B , vol.128 , pp. 81-83
    • Emid, S.1    Creyghton, J.H.N.2
  • 8
    • 44949291663 scopus 로고
    • 2 relaxation and its application to boron-11 NMR imaging of a BNCT agent in an intact rat
    • 2 relaxation and its application to boron-11 NMR imaging of a BNCT agent in an intact rat. J Magn Reson 88 (1990) 369-375
    • (1990) J Magn Reson , vol.88 , pp. 369-375
    • Bendel, P.1    Davis, M.2    Berman, E.3    Kabalka, G.W.4
  • 9
    • 0002312260 scopus 로고
    • Sensitivity and resolution of constant time imaging
    • Gravina S., and Cory D.G. Sensitivity and resolution of constant time imaging. J Magn Reson Series B 104 (1993) 53-61
    • (1993) J Magn Reson Series B , vol.104 , pp. 53-61
    • Gravina, S.1    Cory, D.G.2
  • 10
    • 33645843653 scopus 로고    scopus 로고
    • A comparison of three SPRITE techniques for the quantitative 3D imaging of the 23Na spin density on a 4T whole-body machine
    • Romanzetti S., Halse M., Kaffanke J., Zilles K., Balcom B.J., and Shah N.J. A comparison of three SPRITE techniques for the quantitative 3D imaging of the 23Na spin density on a 4T whole-body machine. J Magn Reson 179 (2006) 56-64
    • (2006) J Magn Reson , vol.179 , pp. 56-64
    • Romanzetti, S.1    Halse, M.2    Kaffanke, J.3    Zilles, K.4    Balcom, B.J.5    Shah, N.J.6
  • 11
    • 2942596219 scopus 로고    scopus 로고
    • Centric scan SPRITE magnetic resonance imaging: optimization of SNR, resolution, and relaxation time mapping
    • Halse M., Rioux J., Romanzetti S., Kaffanke J., MacMillan B., Mastikhin I., et al. Centric scan SPRITE magnetic resonance imaging: optimization of SNR, resolution, and relaxation time mapping. J Magn Reson 169 (2004) 102-117
    • (2004) J Magn Reson , vol.169 , pp. 102-117
    • Halse, M.1    Rioux, J.2    Romanzetti, S.3    Kaffanke, J.4    MacMillan, B.5    Mastikhin, I.6
  • 12
    • 0000305271 scopus 로고
    • Comparison of deuterium NMR imaging methods and application to plants
    • Link J., and Seelig J. Comparison of deuterium NMR imaging methods and application to plants. J Magn Reson 89 (1990) 310-330
    • (1990) J Magn Reson , vol.89 , pp. 310-330
    • Link, J.1    Seelig, J.2
  • 13
    • 18444365887 scopus 로고    scopus 로고
    • Optimizing the point spread function in phase-encoded magnetic resonance microscopy
    • Webb A.G. Optimizing the point spread function in phase-encoded magnetic resonance microscopy. Concepts Magn Reson Part A 22A (2004) 25-36
    • (2004) Concepts Magn Reson Part A , vol.22 A , pp. 25-36
    • Webb, A.G.1
  • 14
    • 4544379596 scopus 로고    scopus 로고
    • Single point imaging with suppressed sound pressure levels through gradient-shape adjustment
    • Latta P., Gruwel M.L.H., Edie E., Šrámek M., and Tomanek B. Single point imaging with suppressed sound pressure levels through gradient-shape adjustment. J Magn Reson 170 (2004) 177-183
    • (2004) J Magn Reson , vol.170 , pp. 177-183
    • Latta, P.1    Gruwel, M.L.H.2    Edie, E.3    Šrámek, M.4    Tomanek, B.5
  • 15
    • 7544240906 scopus 로고    scopus 로고
    • MRI of hip prostheses using single-point methods: in vitro studies towards the artifact-free imaging of individuals with metal implants
    • Ramos-Cabrer P., van Duynhoven J.P.M., Van der Toorn A., and Nicolay K. MRI of hip prostheses using single-point methods: in vitro studies towards the artifact-free imaging of individuals with metal implants. Magn Reson Imaging 22 (2004) 1097-1103
    • (2004) Magn Reson Imaging , vol.22 , pp. 1097-1103
    • Ramos-Cabrer, P.1    van Duynhoven, J.P.M.2    Van der Toorn, A.3    Nicolay, K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.