-
2
-
-
49049127103
-
Spatially resolved high resolution spectroscopy by four dimensional NMR
-
Maudsley AA, Hilal SK. Spatially resolved high resolution spectroscopy by four dimensional NMR. J Magn Reson 1983;51:147-152.
-
(1983)
J Magn Reson
, vol.51
, pp. 147-152
-
-
Maudsley, A.A.1
Hilal, S.K.2
-
4
-
-
0031300505
-
Theoretical evaluation and comparison of fast chemical shift imaging methods
-
Pohmann R, von Kienlin M, Haase A. Theoretical evaluation and comparison of fast chemical shift imaging methods. J Magn Reson 1997;129:145-160.
-
(1997)
J Magn Reson
, vol.129
, pp. 145-160
-
-
Pohmann, R.1
von Kienlin, M.2
Haase, A.3
-
5
-
-
0021669012
-
Spatial mapping of the chemical shift in NMR
-
Mansfield P. Spatial mapping of the chemical shift in NMR. Magn Reson Med 1984;1:370-386.
-
(1984)
Magn Reson Med
, vol.1
, pp. 370-386
-
-
Mansfield, P.1
-
6
-
-
0028087680
-
Three-dimensional echo-planar MR spectroscopic imaging at short echo times in the human brain
-
Posse S, DeCarli C, Le Bihan D. Three-dimensional echo-planar MR spectroscopic imaging at short echo times in the human brain. Radiology 1994;192:733-738.
-
(1994)
Radiology
, vol.192
, pp. 733-738
-
-
Posse, S.1
DeCarli, C.2
Le Bihan, D.3
-
8
-
-
33845239492
-
Signal-to-noise ratio and spectral linewidth improvements between 1.5 and 7 Tesla in proton echo-planar spectroscopic imaging
-
Otazo R, Mueller B, Ugurbil K, Wald L, Posse S. Signal-to-noise ratio and spectral linewidth improvements between 1.5 and 7 Tesla in proton echo-planar spectroscopic imaging. Magn Reson Med 2006;56:1200-1210.
-
(2006)
Magn Reson Med
, vol.56
, pp. 1200-1210
-
-
Otazo, R.1
Mueller, B.2
Ugurbil, K.3
Wald, L.4
Posse, S.5
-
9
-
-
0034845169
-
A generalized approach to parallel magnetic resonance imaging
-
Sodickson DK, McKenzie CA. A generalized approach to parallel magnetic resonance imaging. Med Phys 2001;28:1629-1643.
-
(2001)
Med Phys
, vol.28
, pp. 1629-1643
-
-
Sodickson, D.K.1
McKenzie, C.A.2
-
10
-
-
33744530417
-
Encoding and reconstruction in parallel MRI
-
Pruessmann KP. Encoding and reconstruction in parallel MRI. NMR Biomed 2006;19:288-299.
-
(2006)
NMR Biomed
, vol.19
, pp. 288-299
-
-
Pruessmann, K.P.1
-
12
-
-
0034799867
-
Sensitivity encoded spectroscopic imaging
-
Dydak U, Weiger M, Pruessmann KP, Meier D, Boesiger P. Sensitivity encoded spectroscopic imaging. Magn Reson Med 2001;46:713-722.
-
(2001)
Magn Reson Med
, vol.46
, pp. 713-722
-
-
Dydak, U.1
Weiger, M.2
Pruessmann, K.P.3
Meier, D.4
Boesiger, P.5
-
13
-
-
0037924535
-
Parallel spectroscopic imaging with spin-echo trains
-
Dydak U, Pruessmann KP, Weiger M, Tsao J, Meier D, Boesiger P. Parallel spectroscopic imaging with spin-echo trains. Magn Reson Med 2003;50:196-200.
-
(2003)
Magn Reson Med
, vol.50
, pp. 196-200
-
-
Dydak, U.1
Pruessmann, K.P.2
Weiger, M.3
Tsao, J.4
Meier, D.5
Boesiger, P.6
-
14
-
-
12144267410
-
Reduction of artifacts by optimization of the sensitivity map in sensitivity-encoded spectroscopic imaging
-
Zhao X, Prost RW, Li Z, Li SJ. Reduction of artifacts by optimization of the sensitivity map in sensitivity-encoded spectroscopic imaging. Magn Reson Med 2005;53:30-34.
-
(2005)
Magn Reson Med
, vol.53
, pp. 30-34
-
-
Zhao, X.1
Prost, R.W.2
Li, Z.3
Li, S.J.4
-
15
-
-
32544450311
-
Minimum-norm reconstruction for sensitivity-encoded magnetic resonance spectroscopic imaging
-
Sanchez-Gonzalez J, Tsao J, Dydak U, Desco M, Boesiger P, Pruessmann KP. Minimum-norm reconstruction for sensitivity-encoded magnetic resonance spectroscopic imaging. Magn Reson Med 2006;55:287-295.
-
(2006)
Magn Reson Med
, vol.55
, pp. 287-295
-
-
Sanchez-Gonzalez, J.1
Tsao, J.2
Dydak, U.3
Desco, M.4
Boesiger, P.5
Pruessmann, K.P.6
-
17
-
-
33846783246
-
Sensitivity-encoded (SENSE) proton echo-planar spectroscopic imaging (PEPSI) in human brain
-
Lin FH, Tsai SY, Otazo R, Caprihan A, Wald LL, Belliveau JW, Posse S. Sensitivity-encoded (SENSE) proton echo-planar spectroscopic imaging (PEPSI) in human brain. Magn Reson Med 2007;57:249-257.
-
(2007)
Magn Reson Med
, vol.57
, pp. 249-257
-
-
Lin, F.H.1
Tsai, S.Y.2
Otazo, R.3
Caprihan, A.4
Wald, L.L.5
Belliveau, J.W.6
Posse, S.7
-
18
-
-
36849092725
-
Comparison of SENSE and GRAPPA reconstruction for proton-echo-planar-spectroscopic-imaging (PEPSI)
-
Toronto, Canada
-
Tsai SY, Caprihan A, Posse S, Lin FH. Comparison of SENSE and GRAPPA reconstruction for proton-echo-planar-spectroscopic-imaging (PEPSI). In: Proc 11th Int Conference on Functional Mapping of the Human Brain, Toronto, Canada, 2005. p s43.
-
(2005)
Proc 11th Int Conference on Functional Mapping of the Human Brain
-
-
Tsai, S.Y.1
Caprihan, A.2
Posse, S.3
Lin, F.H.4
-
19
-
-
35949004299
-
GRAPPA reconstruction of sensitivity encoded 2D and 3D proton echo planar spectroscopic imaging (PEPSI) with SNR adaptive recalibrating
-
Seattle
-
Rueckert M, Otazo R, Posse S. GRAPPA reconstruction of sensitivity encoded 2D and 3D proton echo planar spectroscopic imaging (PEPSI) with SNR adaptive recalibrating. In: Proc 14th Annual Meeting ISMRM, Seattle, 2006. p 296.
-
(2006)
Proc 14th Annual Meeting ISMRM
, pp. 296
-
-
Rueckert, M.1
Otazo, R.2
Posse, S.3
-
20
-
-
34248163567
-
Spectral phase-corrected GRAPPA reconstruction of three-dimensional echo-planar spectroscopic imaging (3D-EPSI)
-
Zhu X, Ebel A, Ji JX, Schuff N. Spectral phase-corrected GRAPPA reconstruction of three-dimensional echo-planar spectroscopic imaging (3D-EPSI). Magn Reson Med 2007;57:815-820.
-
(2007)
Magn Reson Med
, vol.57
, pp. 815-820
-
-
Zhu, X.1
Ebel, A.2
Ji, J.X.3
Schuff, N.4
-
22
-
-
7544231110
-
Parallel imaging performance as a function of field strength - an experimental investigation using electrodynamic scaling
-
Wiesinger F, Van de Moortele PF, Adriany G, De Zanche N, Ugurbil K, Pruessmann KP. Parallel imaging performance as a function of field strength - an experimental investigation using electrodynamic scaling. Magn Reson Med 2004;52:953-964.
-
(2004)
Magn Reson Med
, vol.52
, pp. 953-964
-
-
Wiesinger, F.1
Van de Moortele, P.F.2
Adriany, G.3
De Zanche, N.4
Ugurbil, K.5
Pruessmann, K.P.6
-
23
-
-
0036260602
-
Design of a SENSE-optimized high-sensitivity MRI receive coil for brain imaging
-
de Zwart JA, Ledden PJ, Kellman P, van Gelderen P, Duyn JH. Design of a SENSE-optimized high-sensitivity MRI receive coil for brain imaging. Magn Reson Med 2002;47:1218-1227.
-
(2002)
Magn Reson Med
, vol.47
, pp. 1218-1227
-
-
de Zwart, J.A.1
Ledden, P.J.2
Kellman, P.3
van Gelderen, P.4
Duyn, J.H.5
-
25
-
-
4744340025
-
Highly parallel volumetric imaging with a 32-element RF coil array
-
Zhu Y, Hardy CJ, Sodickson DK, Giaquinto RO, Dumoulin CL, Kenwood G, Niendorf T, Lejay H, McKenzie CA, Ohliger MA, Rofsky NM. Highly parallel volumetric imaging with a 32-element RF coil array. Magn Reson Med 2004;52:869-877.
-
(2004)
Magn Reson Med
, vol.52
, pp. 869-877
-
-
Zhu, Y.1
Hardy, C.J.2
Sodickson, D.K.3
Giaquinto, R.O.4
Dumoulin, C.L.5
Kenwood, G.6
Niendorf, T.7
Lejay, H.8
McKenzie, C.A.9
Ohliger, M.A.10
Rofsky, N.M.11
-
26
-
-
20944447767
-
Rapid volumetric MRI using parallel imaging with order-of-magnitude accelerations and a 32-element RF coil array: Feasibility and implications
-
Sodickson DK, Hardy CJ, Zhu Y, Giaquinto RO, Gross P, Kenwood G, Niendorf T, Lejay H, McKenzie CA, Ohliger MA, Grant AK, Rofsky NM. Rapid volumetric MRI using parallel imaging with order-of-magnitude accelerations and a 32-element RF coil array: feasibility and implications. Acad Radiol 2005;12:626-635.
-
(2005)
Acad Radiol
, vol.12
, pp. 626-635
-
-
Sodickson, D.K.1
Hardy, C.J.2
Zhu, Y.3
Giaquinto, R.O.4
Gross, P.5
Kenwood, G.6
Niendorf, T.7
Lejay, H.8
McKenzie, C.A.9
Ohliger, M.A.10
Grant, A.K.11
Rofsky, N.M.12
-
27
-
-
0031425055
-
Theory and applications of array coils in MR spectroscopy
-
Wright SM, Wald LL. Theory and applications of array coils in MR spectroscopy. NMR Biomed 1997;10:394-410.
-
(1997)
NMR Biomed
, vol.10
, pp. 394-410
-
-
Wright, S.M.1
Wald, L.L.2
-
28
-
-
4744358214
-
Depth penetration of RF coil arrays for sequential and parallel imaging
-
Toronto, Canada
-
Sodickson DK, Lee RF, Giaquinto RO, Collins CM, McKenzie CA, Ohliger MA, Grant AK, Willig-Onwuachi JD, Yeh EN, Kressel HY. Depth penetration of RF coil arrays for sequential and parallel imaging. In: Proc 11th Annual Meeting ISMRM, Toronto, Canada, 2003. p 469.
-
(2003)
Proc 11th Annual Meeting ISMRM
, pp. 469
-
-
Sodickson, D.K.1
Lee, R.F.2
Giaquinto, R.O.3
Collins, C.M.4
McKenzie, C.A.5
Ohliger, M.A.6
Grant, A.K.7
Willig-Onwuachi, J.D.8
Yeh, E.N.9
Kressel, H.Y.10
-
29
-
-
0028814635
-
Anomalous transverse relaxation in 1H spectroscopy in human brain at 4 Tesla
-
Posse S, Cuenod CA, Risinger R, Le Bihan D, Balaban RS. Anomalous transverse relaxation in 1H spectroscopy in human brain at 4 Tesla. Magn Reson Med 1995;33:246-252
-
(1995)
Magn Reson Med
, vol.33
, pp. 246-252
-
-
Posse, S.1
Cuenod, C.A.2
Risinger, R.3
Le Bihan, D.4
Balaban, R.S.5
-
30
-
-
0027946439
-
Evaluation of cerebral gray and white matter metabolite differences by spectroscopic imaging at 4.1T
-
Hetherington HP, Mason GF, Pan JW, Ponder SL, Vaughan JT, Twieg DB, Pohost GM. Evaluation of cerebral gray and white matter metabolite differences by spectroscopic imaging at 4.1T. Magn Reson Med 1994;32:565-571.
-
(1994)
Magn Reson Med
, vol.32
, pp. 565-571
-
-
Hetherington, H.P.1
Mason, G.F.2
Pan, J.W.3
Ponder, S.L.4
Vaughan, J.T.5
Twieg, D.B.6
Pohost, G.M.7
-
31
-
-
33745685594
-
32-channel 3 Tesla receive-only phased-array head coil with soccer-ball element geometry
-
Wiggins GC, Triantafyllou C, Potthast A, Reykowski A, Nittka M, Wald LL. 32-channel 3 Tesla receive-only phased-array head coil with soccer-ball element geometry. Magn Reson Med 2006;56:216-223.
-
(2006)
Magn Reson Med
, vol.56
, pp. 216-223
-
-
Wiggins, G.C.1
Triantafyllou, C.2
Potthast, A.3
Reykowski, A.4
Nittka, M.5
Wald, L.L.6
-
32
-
-
0028434775
-
WET a T1-B1-insensitive water suppression method for in vivo localized 1H NMR spectroscopy
-
Ogg RJ, Kingsley PB, Taylor JS. WET a T1-B1-insensitive water suppression method for in vivo localized 1H NMR spectroscopy. J Magn Reson Ser B 1994;104:1-10.
-
(1994)
J Magn Reson Ser B
, vol.104
, pp. 1-10
-
-
Ogg, R.J.1
Kingsley, P.B.2
Taylor, J.S.3
-
33
-
-
0025340810
-
In vivo proton spectroscopy in presence of eddy currents
-
Klose U. In vivo proton spectroscopy in presence of eddy currents. Magn Reson Med 1990;14:26-30.
-
(1990)
Magn Reson Med
, vol.14
, pp. 26-30
-
-
Klose, U.1
-
36
-
-
0027375098
-
Estimation of metabolite concentrations from localized in vivo proton NMR spectra
-
Provencher SW. Estimation of metabolite concentrations from localized in vivo proton NMR spectra. Magn Reson Med 1993;30:672-679.
-
(1993)
Magn Reson Med
, vol.30
, pp. 672-679
-
-
Provencher, S.W.1
-
37
-
-
32544440294
-
-
Henry P-G, Marjanska M, Walls JD, Valette J, Gruetter R, Ugurbil K. POCE NMR spectroscopy in strongly coupled systems. Magn Reson Med 2006;55:250-257.
-
Henry P-G, Marjanska M, Walls JD, Valette J, Gruetter R, Ugurbil K. POCE NMR spectroscopy in strongly coupled systems. Magn Reson Med 2006;55:250-257.
-
-
-
-
39
-
-
0042763165
-
Increase in signal-to-noise ratio of >10,000 times in liquid-state NMR
-
Ardenkjaer-Larsen JH, Fridlund B, Gram A, Hansson G, Hansson L, Lerche MH, Servin R, Thaning M, Golman K. Increase in signal-to-noise ratio of >10,000 times in liquid-state NMR. Proc Natl Acad Sci U S A 2003;100:10158-10163.
-
(2003)
Proc Natl Acad Sci U S A
, vol.100
, pp. 10158-10163
-
-
Ardenkjaer-Larsen, J.H.1
Fridlund, B.2
Gram, A.3
Hansson, G.4
Hansson, L.5
Lerche, M.H.6
Servin, R.7
Thaning, M.8
Golman, K.9
-
40
-
-
34547944567
-
Automatic outer volume suppression (OVS) slice placement for proton-echo-planar- spectroscopic-imaging (PEPSI)
-
Seattle
-
Li T, Martínez-Ramón M, Heileman G, Posse S. Automatic outer volume suppression (OVS) slice placement for proton-echo-planar- spectroscopic-imaging (PEPSI). In: Proc 14th Annual Meeting ISMRM, Seattle, 2006. p 3086.
-
(2006)
Proc 14th Annual Meeting ISMRM
, pp. 3086
-
-
Li, T.1
Martínez-Ramón, M.2
Heileman, G.3
Posse, S.4
|