메뉴 건너뛰기




Volumn 58, Issue 6, 2007, Pages 1107-1116

Accelerated short-TE 3D proton echo-planar spectroscopic imaging using 2D-SENSE with a 32-channel array coil

Author keywords

Echo planar spectroscopic imaging; Large array coil; Parallel imaging; Regularization; SENSE

Indexed keywords

ENCODING (SYMBOLS); METABOLITES; OPTICAL TRANSFER FUNCTION; SIGNAL ENCODING; SINGULAR VALUE DECOMPOSITION;

EID: 36849082930     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.21426     Document Type: Article
Times cited : (38)

References (40)
  • 2
    • 49049127103 scopus 로고
    • Spatially resolved high resolution spectroscopy by four dimensional NMR
    • Maudsley AA, Hilal SK. Spatially resolved high resolution spectroscopy by four dimensional NMR. J Magn Reson 1983;51:147-152.
    • (1983) J Magn Reson , vol.51 , pp. 147-152
    • Maudsley, A.A.1    Hilal, S.K.2
  • 4
    • 0031300505 scopus 로고    scopus 로고
    • Theoretical evaluation and comparison of fast chemical shift imaging methods
    • Pohmann R, von Kienlin M, Haase A. Theoretical evaluation and comparison of fast chemical shift imaging methods. J Magn Reson 1997;129:145-160.
    • (1997) J Magn Reson , vol.129 , pp. 145-160
    • Pohmann, R.1    von Kienlin, M.2    Haase, A.3
  • 5
    • 0021669012 scopus 로고
    • Spatial mapping of the chemical shift in NMR
    • Mansfield P. Spatial mapping of the chemical shift in NMR. Magn Reson Med 1984;1:370-386.
    • (1984) Magn Reson Med , vol.1 , pp. 370-386
    • Mansfield, P.1
  • 6
    • 0028087680 scopus 로고
    • Three-dimensional echo-planar MR spectroscopic imaging at short echo times in the human brain
    • Posse S, DeCarli C, Le Bihan D. Three-dimensional echo-planar MR spectroscopic imaging at short echo times in the human brain. Radiology 1994;192:733-738.
    • (1994) Radiology , vol.192 , pp. 733-738
    • Posse, S.1    DeCarli, C.2    Le Bihan, D.3
  • 8
    • 33845239492 scopus 로고    scopus 로고
    • Signal-to-noise ratio and spectral linewidth improvements between 1.5 and 7 Tesla in proton echo-planar spectroscopic imaging
    • Otazo R, Mueller B, Ugurbil K, Wald L, Posse S. Signal-to-noise ratio and spectral linewidth improvements between 1.5 and 7 Tesla in proton echo-planar spectroscopic imaging. Magn Reson Med 2006;56:1200-1210.
    • (2006) Magn Reson Med , vol.56 , pp. 1200-1210
    • Otazo, R.1    Mueller, B.2    Ugurbil, K.3    Wald, L.4    Posse, S.5
  • 9
    • 0034845169 scopus 로고    scopus 로고
    • A generalized approach to parallel magnetic resonance imaging
    • Sodickson DK, McKenzie CA. A generalized approach to parallel magnetic resonance imaging. Med Phys 2001;28:1629-1643.
    • (2001) Med Phys , vol.28 , pp. 1629-1643
    • Sodickson, D.K.1    McKenzie, C.A.2
  • 10
    • 33744530417 scopus 로고    scopus 로고
    • Encoding and reconstruction in parallel MRI
    • Pruessmann KP. Encoding and reconstruction in parallel MRI. NMR Biomed 2006;19:288-299.
    • (2006) NMR Biomed , vol.19 , pp. 288-299
    • Pruessmann, K.P.1
  • 14
    • 12144267410 scopus 로고    scopus 로고
    • Reduction of artifacts by optimization of the sensitivity map in sensitivity-encoded spectroscopic imaging
    • Zhao X, Prost RW, Li Z, Li SJ. Reduction of artifacts by optimization of the sensitivity map in sensitivity-encoded spectroscopic imaging. Magn Reson Med 2005;53:30-34.
    • (2005) Magn Reson Med , vol.53 , pp. 30-34
    • Zhao, X.1    Prost, R.W.2    Li, Z.3    Li, S.J.4
  • 19
    • 35949004299 scopus 로고    scopus 로고
    • GRAPPA reconstruction of sensitivity encoded 2D and 3D proton echo planar spectroscopic imaging (PEPSI) with SNR adaptive recalibrating
    • Seattle
    • Rueckert M, Otazo R, Posse S. GRAPPA reconstruction of sensitivity encoded 2D and 3D proton echo planar spectroscopic imaging (PEPSI) with SNR adaptive recalibrating. In: Proc 14th Annual Meeting ISMRM, Seattle, 2006. p 296.
    • (2006) Proc 14th Annual Meeting ISMRM , pp. 296
    • Rueckert, M.1    Otazo, R.2    Posse, S.3
  • 20
    • 34248163567 scopus 로고    scopus 로고
    • Spectral phase-corrected GRAPPA reconstruction of three-dimensional echo-planar spectroscopic imaging (3D-EPSI)
    • Zhu X, Ebel A, Ji JX, Schuff N. Spectral phase-corrected GRAPPA reconstruction of three-dimensional echo-planar spectroscopic imaging (3D-EPSI). Magn Reson Med 2007;57:815-820.
    • (2007) Magn Reson Med , vol.57 , pp. 815-820
    • Zhu, X.1    Ebel, A.2    Ji, J.X.3    Schuff, N.4
  • 22
    • 7544231110 scopus 로고    scopus 로고
    • Parallel imaging performance as a function of field strength - an experimental investigation using electrodynamic scaling
    • Wiesinger F, Van de Moortele PF, Adriany G, De Zanche N, Ugurbil K, Pruessmann KP. Parallel imaging performance as a function of field strength - an experimental investigation using electrodynamic scaling. Magn Reson Med 2004;52:953-964.
    • (2004) Magn Reson Med , vol.52 , pp. 953-964
    • Wiesinger, F.1    Van de Moortele, P.F.2    Adriany, G.3    De Zanche, N.4    Ugurbil, K.5    Pruessmann, K.P.6
  • 24
    • 1542346911 scopus 로고    scopus 로고
    • Parallel imaging reconstruction using automatic regularization
    • Lin FH, Kwong KK, Belliveau JW, Wald LL. Parallel imaging reconstruction using automatic regularization. Magn Reson Med 2004;51:559-567.
    • (2004) Magn Reson Med , vol.51 , pp. 559-567
    • Lin, F.H.1    Kwong, K.K.2    Belliveau, J.W.3    Wald, L.L.4
  • 27
    • 0031425055 scopus 로고    scopus 로고
    • Theory and applications of array coils in MR spectroscopy
    • Wright SM, Wald LL. Theory and applications of array coils in MR spectroscopy. NMR Biomed 1997;10:394-410.
    • (1997) NMR Biomed , vol.10 , pp. 394-410
    • Wright, S.M.1    Wald, L.L.2
  • 29
  • 32
    • 0028434775 scopus 로고
    • WET a T1-B1-insensitive water suppression method for in vivo localized 1H NMR spectroscopy
    • Ogg RJ, Kingsley PB, Taylor JS. WET a T1-B1-insensitive water suppression method for in vivo localized 1H NMR spectroscopy. J Magn Reson Ser B 1994;104:1-10.
    • (1994) J Magn Reson Ser B , vol.104 , pp. 1-10
    • Ogg, R.J.1    Kingsley, P.B.2    Taylor, J.S.3
  • 33
    • 0025340810 scopus 로고
    • In vivo proton spectroscopy in presence of eddy currents
    • Klose U. In vivo proton spectroscopy in presence of eddy currents. Magn Reson Med 1990;14:26-30.
    • (1990) Magn Reson Med , vol.14 , pp. 26-30
    • Klose, U.1
  • 36
    • 0027375098 scopus 로고
    • Estimation of metabolite concentrations from localized in vivo proton NMR spectra
    • Provencher SW. Estimation of metabolite concentrations from localized in vivo proton NMR spectra. Magn Reson Med 1993;30:672-679.
    • (1993) Magn Reson Med , vol.30 , pp. 672-679
    • Provencher, S.W.1
  • 37
    • 32544440294 scopus 로고    scopus 로고
    • Henry P-G, Marjanska M, Walls JD, Valette J, Gruetter R, Ugurbil K. POCE NMR spectroscopy in strongly coupled systems. Magn Reson Med 2006;55:250-257.
    • Henry P-G, Marjanska M, Walls JD, Valette J, Gruetter R, Ugurbil K. POCE NMR spectroscopy in strongly coupled systems. Magn Reson Med 2006;55:250-257.
  • 40
    • 34547944567 scopus 로고    scopus 로고
    • Automatic outer volume suppression (OVS) slice placement for proton-echo-planar- spectroscopic-imaging (PEPSI)
    • Seattle
    • Li T, Martínez-Ramón M, Heileman G, Posse S. Automatic outer volume suppression (OVS) slice placement for proton-echo-planar- spectroscopic-imaging (PEPSI). In: Proc 14th Annual Meeting ISMRM, Seattle, 2006. p 3086.
    • (2006) Proc 14th Annual Meeting ISMRM , pp. 3086
    • Li, T.1    Martínez-Ramón, M.2    Heileman, G.3    Posse, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.