메뉴 건너뛰기




Volumn 57, Issue 5, 2007, Pages 815-820

Spectral phase-corrected GRAPPA reconstruction of three-dimensional echo-planar spectroscopic imaging (3D-EPSI)

Author keywords

Brain metabolites; Echoplanar spectroscopic imaging; Partial parallel imaging; Phase correction; Short echo time

Indexed keywords

BIOMOLECULES; DATA ACQUISITION; FREQUENCY DOMAIN ANALYSIS; FREQUENCY ESTIMATION; METABOLITES;

EID: 34248163567     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.21217     Document Type: Article
Times cited : (30)

References (16)
  • 1
    • 0028087680 scopus 로고
    • Three-dimensional echo-planar MR spectroscopic imaging at short echo times in the human brain
    • Posse S, DeCarli C, Le Bihan D. Three-dimensional echo-planar MR spectroscopic imaging at short echo times in the human brain. Radiology 1994;192:733-738.
    • (1994) Radiology , vol.192 , pp. 733-738
    • Posse, S.1    DeCarli, C.2    Le Bihan, D.3
  • 9
    • 34248199474 scopus 로고    scopus 로고
    • GRAPPA reconstruction of sensitivity encoded 2D and 3D proton echo planar spectroscopic imaging (PEPSI) with SNR adaptive recalibrating
    • Philadelphia, PA, USA, Abstract 296
    • Rueckert M, Otazo R, Posse S. GRAPPA reconstruction of sensitivity encoded 2D and 3D proton echo planar spectroscopic imaging (PEPSI) with SNR adaptive recalibrating. In: Proceedings of the 7th Annual Meeting of ISMRM, Philadelphia, PA, USA, 1999 (Abstract 296).
    • (1999) Proceedings of the 7th Annual Meeting of ISMRM
    • Rueckert, M.1    Otazo, R.2    Posse, S.3
  • 10
    • 24144432284 scopus 로고    scopus 로고
    • Achieving sufficient spectral bandwidth for volumetric 1H echo-planar spectroscopic imaging at 4 Tesla
    • Ebel A, Maudsley AA, Weiner MW, Schuff N. Achieving sufficient spectral bandwidth for volumetric 1H echo-planar spectroscopic imaging at 4 Tesla. Magn Reson Med 2005;54:697-701.
    • (2005) Magn Reson Med , vol.54 , pp. 697-701
    • Ebel, A.1    Maudsley, A.A.2    Weiner, M.W.3    Schuff, N.4
  • 11
    • 12844268211 scopus 로고    scopus 로고
    • Detection and correction of frequency instabilities for volumetric 1H echo-planar spectroscopic imaging
    • Ebel A, Maudsley AA. Detection and correction of frequency instabilities for volumetric 1H echo-planar spectroscopic imaging. Magn Reson Med 2005;53:465-469.
    • (2005) Magn Reson Med , vol.53 , pp. 465-469
    • Ebel, A.1    Maudsley, A.A.2
  • 12
    • 0037310854 scopus 로고    scopus 로고
    • Improved spectral quality for 3D MR spectroscopic imaging using a high spatial resolution acquisition strategy
    • Ebel A, Maudsley AA. Improved spectral quality for 3D MR spectroscopic imaging using a high spatial resolution acquisition strategy. Magn Reson Imaging 2003;21:113-120.
    • (2003) Magn Reson Imaging , vol.21 , pp. 113-120
    • Ebel, A.1    Maudsley, A.A.2
  • 13
    • 34248187687 scopus 로고    scopus 로고
    • Rane SD, Ji JX. A MATLAB toolbox for parallel imaging using multiple phased-array coils. In: Proceedings of the 13th Annual Meeting of ISMRM, Miami Beach, FL, USA, 2005 (Abstract 2457).
    • Rane SD, Ji JX. A MATLAB toolbox for parallel imaging using multiple phased-array coils. In: Proceedings of the 13th Annual Meeting of ISMRM, Miami Beach, FL, USA, 2005 (Abstract 2457).
  • 15
    • 0029975951 scopus 로고    scopus 로고
    • Removal of lipid artifacts in 1H spectroscopic imaging by data extrapolation
    • Haupt CI, Schuff N, Weiner MW, Maudsley AA. Removal of lipid artifacts in 1H spectroscopic imaging by data extrapolation. Magn Reson Med 1996;35:678-687.
    • (1996) Magn Reson Med , vol.35 , pp. 678-687
    • Haupt, C.I.1    Schuff, N.2    Weiner, M.W.3    Maudsley, A.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.