메뉴 건너뛰기




Volumn 58, Issue 6, 2007, Pages 1288-1293

SSFP and GRE phase contrast imaging using a three-echo readout

Author keywords

Field mapping; Flow quantitation; Phase contrast; Steady state free precession; Velocity mapping

Indexed keywords

ENCODING (SYMBOLS); FLOW VELOCITY; MAPPING; SIGNAL ENCODING; VELOCITY;

EID: 36849078785     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.21276     Document Type: Article
Times cited : (4)

References (18)
  • 3
    • 0036845660 scopus 로고    scopus 로고
    • Fast phase-contrast velocity measurements in the steady state
    • Overall WR, Nishimura DG, Hu BS. Fast phase-contrast velocity measurements in the steady state. Magn Reson Med 2002;48:890-898.
    • (2002) Magn Reson Med , vol.48 , pp. 890-898
    • Overall, W.R.1    Nishimura, D.G.2    Hu, B.S.3
  • 4
    • 0037407393 scopus 로고    scopus 로고
    • Balanced phase-contrast steady-state free precession (PC-SSFP): A novel technique for velocity encoding by gradient inversion
    • Markl M, Alley MT, Pelc NJ. Balanced phase-contrast steady-state free precession (PC-SSFP): A novel technique for velocity encoding by gradient inversion. Magn Reson Med 2003;49:945-952.
    • (2003) Magn Reson Med , vol.49 , pp. 945-952
    • Markl, M.1    Alley, M.T.2    Pelc, N.J.3
  • 5
    • 21244452331 scopus 로고    scopus 로고
    • In-plane velocity encoding with coherent steady-state imaging
    • Grinstead J, Sinha S. In-plane velocity encoding with coherent steady-state imaging. Magn Reson Med 2005;54:138-145.
    • (2005) Magn Reson Med , vol.54 , pp. 138-145
    • Grinstead, J.1    Sinha, S.2
  • 9
    • 36849026317 scopus 로고    scopus 로고
    • Pulse sequences for phase-contrast SSFP imaging from a single steady-state
    • Seattle
    • Nielsen JF, Nayak KS. Pulse sequences for phase-contrast SSFP imaging from a single steady-state. In: Proceedings of ISMRM, 14th Annual Meeting, Seattle, 2006. p 879.
    • (2006) Proceedings of ISMRM, 14th Annual Meeting , pp. 879
    • Nielsen, J.F.1    Nayak, K.S.2
  • 12
    • 0034956696 scopus 로고    scopus 로고
    • Characterization and reduction of the transient response in steady-state MR imaging
    • Hargreaves BA, Vasanawala SS, Pauly JM, Nishimura DG. Characterization and reduction of the transient response in steady-state MR imaging. Magn Reson Med 2001;46:149-158.
    • (2001) Magn Reson Med , vol.46 , pp. 149-158
    • Hargreaves, B.A.1    Vasanawala, S.S.2    Pauly, J.M.3    Nishimura, D.G.4
  • 13
    • 0027956368 scopus 로고
    • Reconstructions of phase contrast, phased array multicoil data
    • Bernstein MA, Grgic M, Brosnan TJ, Pelc NJ. Reconstructions of phase contrast, phased array multicoil data. Magn Reson Med 1994;32:330-334.
    • (1994) Magn Reson Med , vol.32 , pp. 330-334
    • Bernstein, M.A.1    Grgic, M.2    Brosnan, T.J.3    Pelc, N.J.4
  • 14
    • 0030802130 scopus 로고    scopus 로고
    • Ghost artifact reduction for echo planar imaging using image phase correction
    • Buonocore MH, Gao L. Ghost artifact reduction for echo planar imaging using image phase correction. Magn Reson Med 1997;38:89-100.
    • (1997) Magn Reson Med , vol.38 , pp. 89-100
    • Buonocore, M.H.1    Gao, L.2
  • 15
    • 2942748091 scopus 로고    scopus 로고
    • Removal of EPI nyquist ghost artifacts with two-dimensional phase correction
    • Chen NK, Wyrwicz AM. Removal of EPI nyquist ghost artifacts with two-dimensional phase correction. Magn Reson Med 2004;51:1247-1253.
    • (2004) Magn Reson Med , vol.51 , pp. 1247-1253
    • Chen, N.K.1    Wyrwicz, A.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.