-
1
-
-
0025882983
-
Continuous blood gas monitoring with an intraarterial optode during one-lung anesthesia
-
Greenblott G.B., Tremper K.K., Barker S.J., Gerschultz S., and Gehrich J.L. Continuous blood gas monitoring with an intraarterial optode during one-lung anesthesia. J Cardiothorac Vasc Anesth 5 (1991) 365-367
-
(1991)
J Cardiothorac Vasc Anesth
, vol.5
, pp. 365-367
-
-
Greenblott, G.B.1
Tremper, K.K.2
Barker, S.J.3
Gerschultz, S.4
Gehrich, J.L.5
-
2
-
-
0027388897
-
Anesthesia for thoracoscopic laser ablation of bullous emphysema
-
Barker S.J., Clarke C., Trivedi N., Hyatt J., Fynes M., and Roessler P. Anesthesia for thoracoscopic laser ablation of bullous emphysema. Anesthesiology 78 (1993) 44-50
-
(1993)
Anesthesiology
, vol.78
, pp. 44-50
-
-
Barker, S.J.1
Clarke, C.2
Trivedi, N.3
Hyatt, J.4
Fynes, M.5
Roessler, P.6
-
3
-
-
0030787315
-
Accuracy and clinical performance of a continuous intra-arterial blood-gas monitoring system during thoracoscopic surgery
-
Zollinger A., Spahn D.R., Singer T., et al. Accuracy and clinical performance of a continuous intra-arterial blood-gas monitoring system during thoracoscopic surgery. Br J Anaesth 79 (1997) 47-52
-
(1997)
Br J Anaesth
, vol.79
, pp. 47-52
-
-
Zollinger, A.1
Spahn, D.R.2
Singer, T.3
-
4
-
-
0030977921
-
Video-assisted thoracoscopic volume reduction surgery in patients with diffuse pulmonary emphysema: gas exchange and anesthesiological management
-
Zollinger A., Zaugg M., Weder W., et al. Video-assisted thoracoscopic volume reduction surgery in patients with diffuse pulmonary emphysema: gas exchange and anesthesiological management. Anesth Analg 84 (1997) 845-851
-
(1997)
Anesth Analg
, vol.84
, pp. 845-851
-
-
Zollinger, A.1
Zaugg, M.2
Weder, W.3
-
6
-
-
11144251672
-
Pulse oximetry
-
Jubran A. Pulse oximetry. Intensive Care Med 30 (2004) 2017-2020
-
(2004)
Intensive Care Med
, vol.30
, pp. 2017-2020
-
-
Jubran, A.1
-
7
-
-
0025058987
-
A clinical evaluation of pulse oximetry during thoracic surgery
-
Desiderio D.P., Wong G., Shah N.K., Liu J., Loughlin C.J., and Bedford R.F. A clinical evaluation of pulse oximetry during thoracic surgery. J Cardiothorac Anesth 4 (1990) 30-34
-
(1990)
J Cardiothorac Anesth
, vol.4
, pp. 30-34
-
-
Desiderio, D.P.1
Wong, G.2
Shah, N.K.3
Liu, J.4
Loughlin, C.J.5
Bedford, R.F.6
-
8
-
-
0031689133
-
Substantial changes in arterial blood gases during thoracoscopic surgery can be missed by conventional intermittent laboratory blood gas analyses
-
Zaugg M., Lucchinetti E., Zalunardo M.P., et al. Substantial changes in arterial blood gases during thoracoscopic surgery can be missed by conventional intermittent laboratory blood gas analyses. Anesth Analg 87 (1998) 647-653
-
(1998)
Anesth Analg
, vol.87
, pp. 647-653
-
-
Zaugg, M.1
Lucchinetti, E.2
Zalunardo, M.P.3
-
10
-
-
0021049394
-
Transcutaneous monitoring in the newborn infant
-
Cassady G. Transcutaneous monitoring in the newborn infant. J Pediatr 103 (1983) 837-848
-
(1983)
J Pediatr
, vol.103
, pp. 837-848
-
-
Cassady, G.1
-
11
-
-
0026189280
-
Developments in transcutaneous blood gas monitoring: a review
-
Rithalia S.V. Developments in transcutaneous blood gas monitoring: a review. J Med Eng Technol 15 (1991) 143-153
-
(1991)
J Med Eng Technol
, vol.15
, pp. 143-153
-
-
Rithalia, S.V.1
-
12
-
-
0041828325
-
Continuous intravascular blood gas monitoring: development, current techniques, and clinical use of a commercial device
-
Ganter M., and Zollinger A. Continuous intravascular blood gas monitoring: development, current techniques, and clinical use of a commercial device. Br J Anaesth 91 (2003) 397-407
-
(2003)
Br J Anaesth
, vol.91
, pp. 397-407
-
-
Ganter, M.1
Zollinger, A.2
-
13
-
-
5644246199
-
Accuracy and performance of a modified continuous intravascular blood gas monitoring device during thoracoscopic surgery
-
Ganter M.T., Hofer C.K., Zollinger A., Spahr T., Pasch T., and Zalunardo M.P. Accuracy and performance of a modified continuous intravascular blood gas monitoring device during thoracoscopic surgery. J Cardiothorac Vasc Anesth 18 (2004) 587-591
-
(2004)
J Cardiothorac Vasc Anesth
, vol.18
, pp. 587-591
-
-
Ganter, M.T.1
Hofer, C.K.2
Zollinger, A.3
Spahr, T.4
Pasch, T.5
Zalunardo, M.P.6
-
14
-
-
0029886585
-
Clinical evaluation of a multiparameter intra-arterial blood-gas sensor
-
Abraham E., Gallagher T.J., and Fink S. Clinical evaluation of a multiparameter intra-arterial blood-gas sensor. Intensive Care Med 22 (1996) 507-513
-
(1996)
Intensive Care Med
, vol.22
, pp. 507-513
-
-
Abraham, E.1
Gallagher, T.J.2
Fink, S.3
-
15
-
-
0029905663
-
Continuous intra-arterial blood gas monitoring
-
Venkatesh B., and Hendry S.P. Continuous intra-arterial blood gas monitoring. Intensive Care Med 22 (1996) 818-828
-
(1996)
Intensive Care Med
, vol.22
, pp. 818-828
-
-
Venkatesh, B.1
Hendry, S.P.2
-
16
-
-
0030001419
-
Continuous measurement of arterial blood gas status during total hip replacement: a prospective study
-
Venkatesh B., Pigott D.W., Fernandez A., and Hendry S.P. Continuous measurement of arterial blood gas status during total hip replacement: a prospective study. Anaesth Intensive Care 24 (1996) 334-341
-
(1996)
Anaesth Intensive Care
, vol.24
, pp. 334-341
-
-
Venkatesh, B.1
Pigott, D.W.2
Fernandez, A.3
Hendry, S.P.4
-
17
-
-
23444438705
-
Patterns of changes in arterial PO(2) during one-lung ventilation: a comparison between patients with severe pulmonary emphysema and patients with preserved lung function
-
Aschkenasy S.V., Hofer C.K., Zalunardo M.P., et al. Patterns of changes in arterial PO(2) during one-lung ventilation: a comparison between patients with severe pulmonary emphysema and patients with preserved lung function. J Cardiothorac Vasc Anesth 19 (2005) 479-484
-
(2005)
J Cardiothorac Vasc Anesth
, vol.19
, pp. 479-484
-
-
Aschkenasy, S.V.1
Hofer, C.K.2
Zalunardo, M.P.3
-
18
-
-
0021186312
-
Transcutaneous monitoring of oxygen tension during one-lung anesthesia
-
Tremper K.K., Konchigeri H.N., Cullen B.F., Kapur P.A., Thangathurai D., and Percival C. Transcutaneous monitoring of oxygen tension during one-lung anesthesia. J Thorac Cardiovasc Surg 88 (1984) 22-25
-
(1984)
J Thorac Cardiovasc Surg
, vol.88
, pp. 22-25
-
-
Tremper, K.K.1
Konchigeri, H.N.2
Cullen, B.F.3
Kapur, P.A.4
Thangathurai, D.5
Percival, C.6
-
19
-
-
0020043063
-
Pulmonary oxygen exchange during endobronchial anesthesia: effect of tidal volume and PEEP
-
Katz J.A., Laverne R.G., Fairley H.B., and Thomas A.N. Pulmonary oxygen exchange during endobronchial anesthesia: effect of tidal volume and PEEP. Anesthesiology 56 (1982) 164-171
-
(1982)
Anesthesiology
, vol.56
, pp. 164-171
-
-
Katz, J.A.1
Laverne, R.G.2
Fairley, H.B.3
Thomas, A.N.4
-
20
-
-
0024536965
-
Sampling intervals for clinical monitoring of variables during anesthesia
-
Gravenstein J.S., de Vries A., and Beneken J.E. Sampling intervals for clinical monitoring of variables during anesthesia. J Clin Monit 5 (1989) 17-21
-
(1989)
J Clin Monit
, vol.5
, pp. 17-21
-
-
Gravenstein, J.S.1
de Vries, A.2
Beneken, J.E.3
-
21
-
-
13544264404
-
Permissive hypercapnia: role in protective lung ventilatory strategies
-
Ni C.M., Higgins B., and Laffey J.G. Permissive hypercapnia: role in protective lung ventilatory strategies. Curr Opin Crit Care 11 (2005) 56-62
-
(2005)
Curr Opin Crit Care
, vol.11
, pp. 56-62
-
-
Ni, C.M.1
Higgins, B.2
Laffey, J.G.3
-
22
-
-
0027415093
-
Randomized evaluation of pulse oximetry in 20,802 patients: II. Perioperative events and postoperative complications
-
Moller J.T., Johannessen N.W., Espersen K., et al. Randomized evaluation of pulse oximetry in 20,802 patients: II. Perioperative events and postoperative complications. Anesthesiology 78 (1993) 445-453
-
(1993)
Anesthesiology
, vol.78
, pp. 445-453
-
-
Moller, J.T.1
Johannessen, N.W.2
Espersen, K.3
-
23
-
-
0026653549
-
Cardiovascular effects of periodic occlusions of the upper airways in dogs
-
Scharf S.M., Graver L.M., and Balaban K. Cardiovascular effects of periodic occlusions of the upper airways in dogs. Am Rev Respir Dis 146 (1992) 321-329
-
(1992)
Am Rev Respir Dis
, vol.146
, pp. 321-329
-
-
Scharf, S.M.1
Graver, L.M.2
Balaban, K.3
|