메뉴 건너뛰기




Volumn 24, Issue 3, 1996, Pages 334-341

Continuous measurement of arterial blood gas status during total hip replacement: A prospective study

Author keywords

Equipment: blood gas sensors; Monitoring: oximetry; Surgery: hip replacement

Indexed keywords

BONE CEMENT;

EID: 0030001419     PISSN: 0310057X     EISSN: None     Source Type: Journal    
DOI: 10.1177/0310057x9602400306     Document Type: Article
Times cited : (7)

References (28)
  • 1
    • 0016707713 scopus 로고
    • Risks of total hip replacement
    • Charnley J. Risks of total hip replacement. Br Med J 1975; 4:101.
    • (1975) Br Med J , vol.4 , pp. 101
    • Charnley, J.1
  • 2
    • 0015106891 scopus 로고
    • Cardiovascular effects of implanted acrylic bone cement
    • Phillips H, Cole PV, Lettin AWF. Cardiovascular effects of implanted acrylic bone cement. Br Med J 1971; 3:460-461.
    • (1971) Br Med J , vol.3 , pp. 460-461
    • Phillips, H.1    Cole, P.V.2    Lettin, A.W.F.3
  • 3
    • 0026665421 scopus 로고
    • Cemented versus non-cemented total hip arthroplasty - Embolism, hemodynamics and intrapulmonary shunting
    • Ereth MH, Weber JG, Abel MD, et al. Cemented versus non-cemented total hip arthroplasty - embolism, hemodynamics and intrapulmonary shunting. Mayo Clin Proc 1992; 67:1066-1074.
    • (1992) Mayo Clin Proc , vol.67 , pp. 1066-1074
    • Ereth, M.H.1    Weber, J.G.2    Abel, M.D.3
  • 4
    • 0028205004 scopus 로고
    • Arterial oxygenation and mean arterial blood pressure in patients undergoing total hip replacement. Cemented versus uncemented components
    • Nolan JP. Arterial oxygenation and mean arterial blood pressure in patients undergoing total hip replacement. Cemented versus uncemented components. Anaesthesia 1994; 49:293-299.
    • (1994) Anaesthesia , vol.49 , pp. 293-299
    • Nolan, J.P.1
  • 5
    • 0016782036 scopus 로고
    • Pulmonary and circulatory reactions during total hip replacement surgery
    • Modig J, Malmberg P. Pulmonary and circulatory reactions during total hip replacement surgery. Acta Anaesth Scand 1975; 19:219-237.
    • (1975) Acta Anaesth Scand , vol.19 , pp. 219-237
    • Modig, J.1    Malmberg, P.2
  • 6
    • 0018871490 scopus 로고
    • Air embolism in hip surgery
    • Michel R. Air embolism in hip surgery. Anaesthesia 1980; 35:858-862.
    • (1980) Anaesthesia , vol.35 , pp. 858-862
    • Michel, R.1
  • 7
    • 84970823896 scopus 로고
    • Cardiac arrest and bone cement
    • Hyland J, Robins RHC. Cardiac arrest and bone cement. Br Med J 1970; 4:176-177.
    • (1970) Br Med J , vol.4 , pp. 176-177
    • Hyland, J.1    Robins, R.H.C.2
  • 8
    • 0015138508 scopus 로고
    • Fat embolism following prosthetic replacement of the femoral head
    • Dandy DJ. Fat embolism following prosthetic replacement of the femoral head. Injury 1971; 3:85.
    • (1971) Injury , vol.3 , pp. 85
    • Dandy, D.J.1
  • 9
    • 0016808808 scopus 로고
    • Arterial hypotension and hypoxaemia during total hip replacement: The importance of thromboplastic products, fat embolism and acrylic monomers
    • Modig J, Busch C, Olerud S, Saldeen T, Waernbaum G. Arterial hypotension and hypoxaemia during total hip replacement: the importance of thromboplastic products, fat embolism and acrylic monomers. Acta Anaesthesiol Scand 1975; 19:28-43.
    • (1975) Acta Anaesthesiol Scand , vol.19 , pp. 28-43
    • Modig, J.1    Busch, C.2    Olerud, S.3    Saldeen, T.4    Waernbaum, G.5
  • 12
    • 0026024572 scopus 로고
    • Potential errors in pulse oximetry. I. Pulse oximetry evaluation
    • Ralston AC, Webb RK, Runciman WB. Potential errors in pulse oximetry. I. Pulse oximetry evaluation. Anaesthesia 1991; 46:202-206.
    • (1991) Anaesthesia , vol.46 , pp. 202-206
    • Ralston, A.C.1    Webb, R.K.2    Runciman, W.B.3
  • 13
    • 0026100834 scopus 로고
    • Potential errors in pulse oximetry. III. Pulse oximetry evaluation
    • Ralston AC, Webb RK, Runciman WB. Potential errors in pulse oximetry. III. Pulse oximetry evaluation. Anaesthesia 1991; 46:291-295.
    • (1991) Anaesthesia , vol.46 , pp. 291-295
    • Ralston, A.C.1    Webb, R.K.2    Runciman, W.B.3
  • 14
    • 0023686717 scopus 로고
    • Clinical trial of the Continucath intra-arterial oxygen monitor. A comparison with intermittent arterial blood gas analysis
    • Pfeifer PM, Pearson DT, Clayton RH. Clinical trial of the Continucath intra-arterial oxygen monitor. A comparison with intermittent arterial blood gas analysis. Anaesthesia 1988; 43:677-682.
    • (1988) Anaesthesia , vol.43 , pp. 677-682
    • Pfeifer, P.M.1    Pearson, D.T.2    Clayton, R.H.3
  • 15
    • 8944245562 scopus 로고
    • Performance characteristics of an intra-arterial oxygen electrode in critically ill adult patients
    • Rithalia S, Edwards D, Doran B . Performance characteristics of an intra-arterial oxygen electrode in critically ill adult patients. Br J Intens Care 1992; 29-33.
    • (1992) Br J Intens Care , pp. 29-33
    • Rithalia, S.1    Edwards, D.2    Doran, B.3
  • 17
    • 0025032771 scopus 로고
    • Progress in the development of a fluorescent intravascular blood gas system in man
    • Mahutte CK, Sassoon CSH, Muro JR, et al. Progress in the development of a fluorescent intravascular blood gas system in man. J Clin Monit 1990; 6:147-157.
    • (1990) J Clin Monit , vol.6 , pp. 147-157
    • Mahutte, C.K.1    Sassoon, C.S.H.2    Muro, J.R.3
  • 18
    • 0027413775 scopus 로고
    • Initial evaluation of a new intra-arterial blood gas system in humans
    • Zimmerman J, Dellinger R. Initial evaluation of a new intra-arterial blood gas system in humans. Crit Care Med 1993; 21:495-500.
    • (1993) Crit Care Med , vol.21 , pp. 495-500
    • Zimmerman, J.1    Dellinger, R.2
  • 19
    • 0029024970 scopus 로고
    • Misleading information from pulse oximetry and the usefulness of continuous blood gas monitoring in a post cardiac surgery patient
    • Benson JP, Venkatesh B, Patla V. Misleading information from pulse oximetry and the usefulness of continuous blood gas monitoring in a post cardiac surgery patient. Intens Care Med 1995; 21:437-439.
    • (1995) Intens Care Med , vol.21 , pp. 437-439
    • Benson, J.P.1    Venkatesh, B.2    Patla, V.3
  • 20
    • 0028214567 scopus 로고
    • A multiparameter sensor for continuous intra-arterial blood gas monitoring: A prospective evaluation
    • Venkatesh B, Glutton Brock TH, Hendry SP. A multiparameter sensor for continuous intra-arterial blood gas monitoring: A prospective evaluation. Crit Care Med 1994; 22:188-194.
    • (1994) Crit Care Med , vol.22 , pp. 188-194
    • Venkatesh, B.1    Glutton Brock, T.H.2    Hendry, S.P.3
  • 21
    • 8944249473 scopus 로고
    • Clinical evaluation of a multiparameter intra-arterial blood gas sensor
    • Abraham E, Gallagher TJ, Fink S. Clinical evaluation of a multiparameter intra-arterial blood gas sensor. Crit Care Med (Suppl) 1994; 22:A60.
    • (1994) Crit Care Med (Suppl) , vol.22
    • Abraham, E.1    Gallagher, T.J.2    Fink, S.3
  • 22
    • 0028636516 scopus 로고    scopus 로고
    • The continuous measurement of blood gases using a combined electrochemical and spectrophotometric blood gas monitor in Intensive Care patients
    • Venkatesh B, Clutton Brock TH, Hendry SP. The continuous measurement of blood gases using a combined electrochemical and spectrophotometric blood gas monitor in Intensive Care patients. J Med Eng Technol 18; 5:165-168.
    • J Med Eng Technol 18 , vol.5 , pp. 165-168
    • Venkatesh, B.1    Clutton Brock, T.H.2    Hendry, S.P.3
  • 23
    • 0029151933 scopus 로고
    • Evaluation of the Paratrend 7 monitor during cardiopulmonary bypass. Comparison with an in-line analyser
    • Venkatesh B, Clutton Brock TH, Hendry SP. Evaluation of the Paratrend 7 monitor during cardiopulmonary bypass. Comparison with an in-line analyser. J Cardiothorac Vasc Anaesth 1995; 9:412-419.
    • (1995) J Cardiothorac Vasc Anaesth , vol.9 , pp. 412-419
    • Venkatesh, B.1    Clutton Brock, T.H.2    Hendry, S.P.3
  • 24
    • 0014057289 scopus 로고
    • Determination of the blood gas factor of the oxygen electrode using a new tonometer
    • Adams AP, Morgan-Hughes JO. Determination of the blood gas factor of the oxygen electrode using a new tonometer. Br J Anaesth 1967; 39:107-113.
    • (1967) Br J Anaesth , vol.39 , pp. 107-113
    • Adams, A.P.1    Morgan-Hughes, J.O.2
  • 25
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 307-310.
    • (1986) Lancet , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 26
    • 0022502631 scopus 로고
    • Blood levels and half life of methylmethacrylate after tourniquet release during knee arthroplasty
    • Svartling N, Pfaffli P, Tarkannen L. Blood levels and half life of methylmethacrylate after tourniquet release during knee arthroplasty. Arch Orthop Trauma Surg 1986; 105:36-39.
    • (1986) Arch Orthop Trauma Surg , vol.105 , pp. 36-39
    • Svartling, N.1    Pfaffli, P.2    Tarkannen, L.3
  • 28
    • 0028270188 scopus 로고
    • Echocardiography of transatrial embolism during cemented and non cemented hemiarthroplasty of the hip
    • Christie J, Burnett R, Potts HR, Pell AC. Echocardiography of transatrial embolism during cemented and non cemented hemiarthroplasty of the hip. Br J Bone Joint Surg 1994; 76:409-412.
    • (1994) Br J Bone Joint Surg , vol.76 , pp. 409-412
    • Christie, J.1    Burnett, R.2    Potts, H.R.3    Pell, A.C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.